TrueAlarm Fire Alarm Controls

Similar documents
TrueAlarm Fire Alarm Systems

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

INTELLIGENT FIRE ALARM CONTROL PANEL

LifeAlarm Fire Alarm Control Panels

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Intelligent Security & Fire Ltd

Network Display Unit Installation Instructions

E3 Series Broadband System

Multi-Application Peripherals and Accessories

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ECC-50/100C. Emergency Command Center

E3 Series Broadband System

July 14, 1999 DF C-100.

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TrueAlarm Fire Alarm Controls

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Addressable Fire Alarm Control Panel

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Installation, Operating and Maintenance Manual

user manual Document No , Revision 03 November 2015

The EN54 Part 2 & 4 Fire System

Document No Issue 4 user manual

Specification/ Data Sheet

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

MPC-6000 / MPC-7000 / RND-2

Fire Detection and Alarm

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

The EN54 Part 2, 4 and 13 Fire System

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Vocia VACIE. Reference Guide

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Commercial and Light Industrial Fire Alarm Control Panel

TrueAlarm ES Analog Sensing

VACIE REFERENCE GUIDE REVISION 1.2.6

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

ZXSe Range Data Sheet

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

TrueAlarm Analog Sensing

DS7400Xi Addressable Control/ Communicator

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SP40S-D. Kingfisher Company, inc. Features: Description:

Excel-EN Conventional Fire Control Panel

Fire Command Keypad. XR5 User s Guide

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Control/Communicator

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

June 10, 2002 DF C S2424

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Panel Remote Annunciators Installation Instructions

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

Advanced FireAlarm Panel 1-4Loop

AND ARCHITECT SPECIFICATIONS

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

LifeAlarm Fire Alarm Controls

Multi-Point Peripherals

380 SERIES REMOTE SIREN ETSA380R

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Intelligent Single Loop Fire Alarm Control Panel

Control/Communicator Installation Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

4007ES Fire Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Alarm Tone Generator Model AG17

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

30.45 Electric Release PDRP-2001

Intelligent Security & Fire Ltd

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

P Zone Expandable Hybrid Security System

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

TABLE OF CONTENTS TABLE OF CONTENTS 1

TrueAlert Addressable Notification Appliances

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Transcription:

FIRE ALARM ALARMS S DISABLEMENT DISABLED ZONES SITE SPECIFIC PROGRAMMABLE KEYS/LEDS S /DISABLED SILENCED DISABLE/ENABLE S SILENCE/RESOUND SYSTEM PULL DOOR TO OPEN RESET PANEL SILENCE POWER INDICATION OF ALARM, WARNING, OR DISABLED CONDITION: - GENERAL VISIBLE INDICATOR AND AUDIBLE INDICATOR ON. TO VIEW SUPPRESSED ALARM,, OR DISABLED INDICATIONS: - PRESS "" KEY LOCATED UNDER EACH VISIBLE INDICATOR. - REPEAT UNTIL ALL SUPPRESSED INDICATIONS HAVE BEEN DISPLAYED. TO SILENCE THE LOCAL AUDIBLE INDICATIONS: - PRESS "PANEL SILENCE" KEY. TO SILENCE THE ALARM SIGNALS: - PRESS "" SILENCE/RESOUND" KEY. TO RESTORE SYSTEM TO NORMAL: -PRESS "RESET" KEY. TrueAlarm Fire Alarm Controls EN54 Compliant* 4100 and 4120 Series Fire Alarm Control and Indicating Equipment (c.i.e) Features Conforms to EN54-2 and EN54-4 Standards* Control panel hardware feature summary: 160 Character super-twist LCD readout (4 lines x 40 characters/line) Membrane keypad with insert labels Expandable up to 512 points/32 zones Supports conventional and addressable inputs: MAPNET II Addressable Devices including isolator modules TrueAlarm Addressable Analog Sensors** Nonvolatile flash EPROM memory Temperature compensated battery charger Battery supervision (low/no battery) Software Features: Four operator access levels 300 Event historical alarm and fault logs Zonal and point alarm information Alarm resound feature Programmable: Site specific programmable keys/leds Powerful custom control provides maximum flexibility Optional Voice Evacuation and Fire Brigade phones: Single, dual, and triple channel Custom voice messages and tones 2-Way fire brigade voice communications 25 W and 100 W, 25 VRMS Amplifiers Interface to Remote: MINIPLEX Transponders 4604-9202UK Remote LCD Annunciator for supplementary operations Optional Modules: 4120 Network Interface Sounder outputs Conventional and addressable inputs Control relays with feedback Mimic panel modules Expansion power supplies *** System is Normal *** 09:36:24 MON 05-APR-1999 4100 FIRE ALARM CONTROL EMERGENCY OPERATING INSTRUCTIONS 4100/4120 Series Control and Indicating Equipment (shown as a 6 unit panel with optional voice control) Description Simplex 4100/4120 Series Control and Indicating Equipment provide an extensive and powerful feature list to satisfy a wide variety of applications and local requirements. They are on-site programmable to provide mapping logic for inputs and outputs and for custom labeling additions and revisions. Their flexible site-specific software features can be quickly and securely generated, modified, and archived by trained service personnel using computer based programming tools. With this flexibility, last minute changes can be made on-site, minimizing delays in job completion. Input point expansion is available up to a maximum of 512 points in any combination of input types. NOTE: When these c.i.e. products are factory configured for 4120 Network Control panel operation, substitute 4100 for 4120. Contact your local Simplex representative for additional information about the 4120 Network. * Refer to pages 6 and 7 for additional information on EN54 compatibility and LPC testing status. ** MAPNET II addressable communications is protected under U.S. Patent # 4,796,025. TrueAlarm addressable smoke detection operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460. 1999 Simplex Time Recorder Co. All rights reserved. S4100-0025 (EN54) 5/99

Operator Interaction The illustration below identifies the LCD readout and the primary operator indicators and switch functions. When the internal access door is lowered, the additional keypad shown is available for extended operator functions. Some of the features include: Bright LED indicators and LCD alphanumeric information for accurate status presentation Nomenclature that is provided by insert, allowing the terminology to be revised to suit local language needs Four site-specific programmable LEDs and switch keys for use as required by the individual location Typical LCD information is displayed in sequence: Line 1: First zone in alarm/menu Line 2: Menu information Line 3: Most recent zone in alarm Line 4: Total event counts Password Access Four levels of password protection are available. Typical access divisions are per the following: Operation View software revision, test indicators Access alarmed zones not shown Display suppressed faults or disablements Silence local sounder Reset latching fault conditions Silence fire alarm sounders Resound fire alarm sounders Initiate reset process Disable/enable points, zones, or outputs Set time and date, View historical logs Level Clear historical logs, Manually control points and lists 3 Disconnect or adjust main or standby power Modify program contents (EXEC) Alter site-specific data (CFIG) 1 2 4 Operator Control Panel Functions STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and change to steady on after one minute RED FIRE ALARM LED flashes when a new alarm event is received and ALARMS KEY steps through alarm events RESET KEY initiates system reset process PANEL SILENCE KEY turns off the local sounder YELLOW SYSTEM LED turns on to indicate a system fault GREEN POWER LED turns on whenever the c.i.e. is powered, either mains or battery 4 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information EXTENDED FUNCTION KEYPAD (accessible with door open) select and scroll through display prompts for locating additional system information, performing maintenance functions *** System is Normal *** ZN 1 FB 4 SIG 2 IO 5 AUX 3 MAP 6 09:36:24 MON 05-APR-1999 P 7 A 8 ZONE 9 FIRE ALARM DISABLEMENT /DISABLED S SILENCED RESET NET - ENTER FUNC 0 DEL CLR ALARMS S DISABLED ZONES DISABLE/ENABLE S SILENCE/RESOUND PANEL SILENCE NEXT PREV SYSTEM POWER MENU SITE SPECIFIC PROGRAMMABLE KEYS/LEDS YELLOW LED flashes when a new fault event is received, S KEY steps through fault events YELLOW DISABLEMENT LED flashes when a new disablement event is received, DISABLED ZONES KEY steps through disabled zones YELLOW S SILENCED LED turns on to indicate that the sounder points have been turned off, SILENCE/RESOUND KEY silences the sounders when on and will resound them when pressed again FOUR PROGRAMMABLE SWITCHES WITH YELLOW LEDs provide custom operations labeling (labels insert into a pocket) YELLOW LED flashes when there is a fault on a sounder circuit and turns on steady when a sounder circuit is disabled, DISABLE/ENABLE S KEY allows all sounders to be disabled simultaneously Simplex Time Recorder Co. 2 S4100-0025 (EN54) 5/99

Master Controller Module The 4100/4120-7014 Master Controller Board provides system control, synchronization, and supervision of all modules, continuously scanning each module for status changes. Features include: Operator s Panel with LCD and operator keys General Fault Output General Alarm Output, form C contact output RS-232 Dual Port Communications Module, one port is dedicated to control the user interface panel, one port is unassigned (can be connected to remote LCD Annunciator 4604-9202UK) Battery Charger for up to 110 Ah Batteries Batteries up to 42 Ah may be mounted in the bottom of the control cabinet Batteries larger than 42 Ah mount external to main control cabinet Intelligent Power Supply: Two isolated outputs of 4 Amps each at 28.5 VDC when mains powered (24 VDC nominal during battery operation) Tap B provides 4 A for general purpose sounder circuits and control power Tap A provides 2 A (typical) for sounder circuits controlling clean loads with controlled inrush current and proper transient suppression (actual available power depends on total system power requirements) Optional Modules Description Conventional Zone Circuits: Eight circuit zone modules provide system expansion as Class B operation Capable of supporting two-wire Simplex smoke detectors and electronic heat detectors plus normally open contact devices (manual stations, mechanical heat detectors, etc.) Sounder and Speaker Circuits: Two, four, or six circuit modules provide Class B system expansion Circuit ratings: 2 A @ 24 VDC; 50 W @ 25 VRMS (for speaker circuits), or for up to 6 telephones Supervised for opens, grounds, and wire-to-wire shorts Dual and Triple channel modules have integral switching relays for selecting the proper audio channel output Outputs can be programmed for temporal code or march time code RS-232 Dual Port Communication Module: Up to four additional RS-232 modules total Each port can be vectored by event category Auxiliary Control Relays: Built-in fuse protection per contact Feedback tracks on/off status of remote devices 4100-3001, four CPU controlled relays, DPDT contacts rated for 2 A @ 24 VDC 4100-3002, four CPU controlled relays, DPDT contacts rated 10 A @ 24 VDC 4100-3003, eight CPU controlled relays, SPDT contacts rated 3 A @ 24 VDC LED Annunciation: Optional interface modules are available for remote and/or local control panel annunciation. The LEDs are programmable for slow rate, fast rate pulse, or steady illumination. 64/64 LED/Switch Controller: Interfaces up to 64 LEDs and 64 switches to the master controller via serial communications Continuously monitors switches for changes in status Supervises and controls LEDs Supervises LED/switch module placement 24 Point I/O Graphic Interface: Each of the 24 points can be individually configured as either a switch input or a lamp driver output 150 ma lamp driver output (+24 VDC common) Outputs can be steady, slow pulse, or fast pulse Switch inputs can monitor two position or three position switches Lamp test input LED/Switch Modules: Modules contain socketed LEDs to allow interchanging with different color LEDs to indicate function Switch modules can be used to perform manual control such as for HVAC, pressurization fans, damper control, speaker circuits, etc. MAPNET II, TrueAlarm Addressable Module: Connections for up to 120 MAPNET II addressable devices or TrueAlarm analog sensors per module MAPNET II Line Isolator Modules are available for protecting Class A addressable circuit loops from short circuits Remote Unit Interface (RUI) Modules: Provides a supervised serial communication channel for control and monitoring of remotely located mimic panels, MINIPLEX transponders, and I/O panels Simplex Time Recorder Co. 3 S4100-0025 (EN54) 5/99

FIRE ALARM ALARMS S DISABLEMENT DISABLED ZONES /DISABLED DISABLE/ENABLE S S SILENCED SILENCE/RESOUND SYSTEM RESET PANEL SILENCE POWER MINIPLEX Distributed Module Operation Up to 31 MINIPLEX transponders can be controlled from the c.i.e. Allows remote location of: amplifiers, MAPNET II and TrueAlarm interface modules, conventional zone circuits, sounder circuits, and auxiliary control circuits Up to four RUI modules can be installed in the c.i.e. 4604-9202UK Remote LCD Annunciator For supplementary applications, the model 4604-9202UK remote LCD annunciator provides an informational display similar to that on the front of the c.i.e. Details are as follows: Surface mounted, cabinet included LED backlighting for easy reading Backlighting is off during battery power except during keypad activity (when activity ceases, the backlighting will time out and again turn off) Connections are serial communications via RS-232 wiring Distance is up to 25 ft (7.6 m) Dimensions: 12 13/16 W x 9 7/8 H x 2 1/8 D (325 mm x 251 mm x 54 mm) *** System is Normal *** 09:36:24 MON 05-APR-1999 SITE SPECIFIC PROGRAMMABLE KEYS/LEDS ZN 1 FB 4 P 7 NET - ENTER NEXT 4604-9202UK LCD Annunciator Audio Control Board Features Message Memory - Custom Message Data Routing Matrix - Input/Output Switching Audio Inputs: Master Microphone Remote Microphone #1 (Optional) Remote Microphone #2 (Optional) Primary Voice/Tone Generator (Optional) Secondary Voice/Tone Generator (Optional) Phone to Audio Interface SIG 2 IO 5 A 8 FUNC 0 MENU AUX 3 MAP 6 ZONE 9 DEL CLR PREV Audio Outputs: Channel 1, Single Channel Channel 2, Dual Channel Channel 3, Triple Channel Local Panel Speaker Audio Tones: Slow Whoop - Slowly ascending tone from 200 to 830 Hz in 2.5 seconds, recommended for fire alarm and no other purpose High/Low - Free-running signal with a high frequency of 750 Hz for 100 msec and a low frequency of 500 Hz for 400 msec Horn - Continuous 500 Hz tone primarily used for coded systems Chime - 600 Hz fundamental tone with a 1.5 sec duration, used as a free-running tone or for coded operation Beep - 500 Hz tone of 0.7 sec on, 0.7 sec off Stutter - 500 Hz tone with equal on and off times of 100 ms Wail - Ascends, then descends between 600 to 940 Hz GSA Tone - Continuous 2000 Hz tone Bell - A fundamental frequency of 350 Hz with prominent harmonics at 700 Hz and 2100 Hz Zone coded signaling is available using tones or spoken numbers. Spoken coded messages can be used in place of conventional pulse tone coding eliminating counting and interpretation of the zone coded location. For example, a fire alarm zone such as 1st Floor East Smoke Detector Room 23 will be Code 1123. Two possible transmission schemes are: 1. Conventional Zone coded Signaling where T = Tone: T...T...TT...TTT...T...T...TT...TTT... 2. Spoken Coded Signaling : code, one..one..two..three... code, one..one. two..three The Digital Audio Controller has the ability to precede spoken codes with phrases and alert tones. As an alternative, the previous example could have been preceded with a chime tone. The word code could be replaced with the phrase Doctor Firestone, please dial.... Preprogrammed custom messages are available on request. Up to five minutes of special phrases and messages are available to meet specific applications. Audio Amplifiers: Models are available with 25 VRMS output and rated at 25 W output without a dedicated power supply and with 100 W output with a dedicated power supply Frequency response of 120 to 12,000 Hz Battery backup capability Integral amplifier monitor for supervised operation Optional redundant operation automatically switches-over from primary to backup amplifier Simplex Time Recorder Co. 4 S4100-0025 (EN54) 5/99

FIRE ALARM ALARMS *** System is Normal *** 09:36:24 MON 05-APR-1999 S DISABLEMENT DISABLED ZONES /DISABLED DISABLE/ENABLE S SITE SPECIFIC PROGRAMMABLE KEYS/LEDS S SILENCED SILENCE/RESOUND SYSTEM PULL DOOR TO OPEN RESET PANEL SILENCE POWER INDICATION OF ALARM, WARNING, OR DISABLED CONDITION: - GENERAL VISIBLE INDICATOR AND AUDIBLE INDICATOR ON. TO VIEW SUPPRESSED ALARM,, OR DISABLED INDICATIONS: - PRESS "" KEY LOCATED UNDER EACH VISIBLE INDICATOR. - REPEAT UNTIL ALL SUPPRESSED INDICATIONS HAVE BEEN DISPLAYED TO SILENCE THE LOCAL AUDIBLE INDICATIONS: - PRESS "PANEL SILENCE" KEY. TO SILENCE THE ALARM SIGNALS: - PRESS "" SILENCE/RESOUND" KEY. TO RESTORE SYSTEM TO NORMAL: -PRESS "RESET" KEY. Audio Component Details EMERGENCY OPERATING INSTRUCTIONS Master Controller One-Way Voice Communications Microphone Two-Way Firefighter Master Phone 4100 FIRE ALARM CONTROL Telephone Circuit Selector Switches Local Panel Speaker Audio Control Switch Module Voice Communication Components One-Way Communications Systems: Single and dual channel audio Triple channel audio with a dedicated microphone channel Multiple supervised remote microphone inputs Multiple built-in selectable tones Spoken voice coding Multiple digitally recorded human voice messages Digitized voice/tone generation Automatic or manual audio control Separate evacuation, drill, and optional all clear voice messages and tones Ready-to-talk indicator for microphone Optional synchronized redundant voice tone generator Local panel speaker for tone/message broadcast verification MINIPLEX voice transponders for distributed audio Fire Brigade Telephone Systems: Telephone to audio interface Multiple remote master phones Ring signal on remote telephone indicates call request Telephone circuits are supervised for open and short circuit conditions General Systems with audio provide one-way voice communication, alarm tones, and/or digitally prerecorded voice messages to alert occupants of fire or other emergency situations. Evacuation signaling may be automatically generated via alarm initiated event programs in the 4100 Master Controller or by firefighting personnel operating the system microphone. The system may also be equipped with a Fire Brigade Master Telephone module to provide the Fire Commander with two-way communications with firefighters or fire wardens located remotely throughout the building. Operation Audio Control Board provides routing and preamplification of digitized alarm tones and voice messages. Actual tones and voice messages are digitally recorded and stored in the audio control board s message memory. When called upon, an integral Voice Tone Generator (VTG) recreates the audio waveforms of the prerecorded voice/tone messages with completely natural sound. The Audio Control board receives instructions from the Master Controller to direct the routing of the audio tones, codes, prerecorded or manual voice messages to the appropriate audio output circuits. Simplex Time Recorder Co. 5 S4100-0025 (EN54) 5/99

Product Selection (LPC approval status designated per model number, see legend below) System Type (select 4100 prefix for stand-alone systems, 4120 prefix for networked systems) 8001 Basic Fire Control Panel 8010 Miniplex Control Panel 8201 Control Panel with Audio 8210 Miniplex Control Panel with Audio 8019 Miniplex Transponder Master Controller Option (1) Choose One See below 4100-7014 EN54 Master Controller Standard (2) 4120-7014 Assembly with Display For 4120 Network System Requirements Choose One 625 ma 675 ma 8 Internal 16 Retainer 10 Internal 16 Retainer 6027 CE Mark Option 6081 Version 8 Software 6051 Non Power-limited Conventional Zone Circuits (2) Required Not applicable 5004 8 Zone Class B (2) As Required 75 ma 195 ma 2 Internal Sounder and Speaker Circuits 4001 Two Circuit Class B 16 ma 33 ma 4205 Dual Circuit, Triple Channel Class B (2) As Required 25 ma 80 ma 4321 Six Circuit Class B Auxiliary Relay Control 25 ma 70 ma 2 Internal 3001 Four Relays, 2A with Feedback 15 ma 75 ma 2 Internal 3002 Four Relays, 10A with Feedback As Required 15 ma 175 ma 4 Internal 3003 Eight Relays, 3A with Feedback (2) Power Supply Options 25 ma 280 ma 2 Internal 0157 8 A Intelligent Power Supply with Charger, 230 VAC 0158 8 A Power Supply, 230 VAC (2) As Required 0164 Interface Options Temperature Compensated Battery Charger, 230 VAC 6 Internal 4 Internal 0110 MAPNET II Addressable Zone Module 470 ma 490 ma 4 Internal 0113 Dual RS232 Module (2) As Required 132 ma 132 ma 0304 Remote Unit Interface (RUI) Audio Controller Board Options 85 ma 85 ma 2 Internal 0210 Single Channel Operation 185 ma 185 ma 0211 Dual Channel Operation (3) Choose One as Required 220 ma 220 ma 0212 Triple Channel Operation 220 ma 220 ma (1) LPC (Loss Prevention Council) Approval pending for 4100 model series (PIDs) only. (2) LPC Approval pending. (3) Tested by LPC to verify that no detrimental effect occurred to mandatory EN54 functions. Module size: Internal = only occupies space behind retainer panel. Retainer = only occupies space at retainer panel level and internal modules can be located behind. 12 Internal Module Size Reference: Each unit of space has 16 (406 mm) of panel width available. (8 = 203 mm, 4 = 102 mm, 2 = 51 mm) Simplex Time Recorder Co. 6 S4100-0025 (EN54) 5/99

Product Selection (Continued) Audio Amplifiers (supervisory current is with switch to battery selected) 0251 25 VRMS, 25 W, without Power Supply 36 ma 2.2 A 2 Internal 0263 25 VRMS, 100 W, with 230 VAC Power (3) As Required Supply 68 ma 8.75 A 8 Internal Audio Equipment Options 0254 Microphone and Enclosure 3 ma 7 ma (3) 0255 Master Phone 22 ma 142 ma 4 Retainer 0206 Redundant Tone Generator 45 ma 45 ma As Required 0215 Phone Riser Terminal Board Standard Message Set (Custom Not applicable 0220 Messages are Available) Annunciation Equipment 0301 64/64 LED/Switch Controller, Internal (2) 15 ma 260 ma 0302 24 Point I/O Graphic Interface, Internal 34 ma 75 ma 0431 Eight Red LED Module 0432 16 Red/Yellow LED Module 0433 0434 8/8 Momentary Switch/Yellow LED Module 8/16, 3 Position Maintained Switch/Yellow-Yellow LED Module 0435 8/16 Momentary Switch/LED Module Network Equipment (2) As Required Not applicable 2 Internal 2 Retainer Model Description LPC Status Quantity Standby Alarm Module Size 4120-6014 Modular Network Interface Board 35 ma 35 ma 2 Internal 4120-0142 Wired Media Card As Required 40 ma 40 ma 4120-0143 Fiber Optic Media Card Cabinets and Accessories 25 ma 25 ma 2052 Four Unit 2053 Six Unit 2062 Four Unit 2063 Six Unit with Glass Door with Solid Door 2975-9405 Four Unit Beige Cabinet, CE Compliant 2975-9406 Six Unit Beige Cabinet, CE Compliant (2) Choose One Per Cabinet Choose One Per Cabinet 2975-9801 Semi-Flush Trim As Required Remote Mount Options Not applicable 4604-9202UK 7401* Remote LCD Panel 24 Point Graphic Interface Module, Remote 7402* 64/64 LED/Switch Controller, Remote 7403* 32 Point LED Driver Module, Remote 7404* 32 Point Switch Input Module, Remote One maximum if required (see page 4) 60 ma 200 see p. 4 42 ma + switch loads* 67 ma + switch loads* 78 ma + outputs* 285 ma fully loaded* current is included with control module 0440 Remote Microphone Enclosure 3 ma 7 ma 0441 Remote Phone (2) LPC Approval pending. As Required (3) Tested by LPC to verify that no detrimental effect occurred to mandatory EN54 functions. * Refer to Simplex document S4100-0005 for additional information. 6 1/2 x12 1/4 (165 x 311 mm) 3 1/4 x 12 1/4 (83 x 311 mm) 4 Retainer Simplex Time Recorder Co. 7 S4100-0025 (EN54) 5/99

Mounting Information Model Number Size Height Cabinet Width Cabinet Depth Door Width 2975-9405 4-Unit 36 1/4 (921 mm) 2975-9406 6-Unit 52 1/8 (1324 mm) 25 3/4 (654 mm) 6 3/4 (171 mm) 26 3/8 (670 mm) 2 1/4" (57 mm) 7 3/4" (197 mm) See chart IMPORTANT: Distance between close coupled dual cabinets must be no less than 3 inches (76 mm) and no more than 24 inches (610 mm) 3" (76 mm) 3 3/4" (95 mm) Installation Detail Side View General Operating Specifications Input Power Requirements Mains Input, 230 VAC base models Mains Input with 230 VAC expansion power supply Mains Input, 4100-0263, 100 W Amplifier Environmental 1 A maximum 2 A maximum 2 A maximum per amplifier 195 to 253 VAC, 50/60 Hz Ambient Temperature Range 23 F to 113 F (-5 C to 45 C) Relative Humidity Range Solar Radiation 700 W/cm 2 5% to 95%, condensation or ice formation is permissible on the outside of the unit Simplex, the Simplex logo, MAPNET, and TrueAlarm are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. S4100-0025 (EN54) 5/99 Gardner, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice.