i200/i250/i200p/i250p Submittal Data Date: Project Name: Bid Date: Model: i200 i200p Project #: i250 i250p Location: Engineer: Fuel Type: Natural Gas Propane Contractor: Key Features Stainless (316L) heat exchanger Flexible-Floating Design, stress relieving and thermal shock capable. Multi-Unit- masterless cascading with common venting Gas Pressures- Operates on gas pressures range of 2.5"-14" w.c. Designed and Built in the U.S. Performance Turndown Ratio of 7:1 (i200/i200p) & 8.3:1 (i250/i250p) per unit. Cascade up to 10 units with common venting for a possible total of over 2500MBH and up to 83:1 total turndown ratio Flow (GPM) Temperature Difference (ΔT) ⁰F 40 50 60 70 80 90 100 i200/i200p 9.4 7.5 6.3 5.4 4.7 4.2 3.8 i250/i250p 11.7 9.3 7.8 6.7 5.8 5.2 4.7
Pressure Drop 25 57.8 i200/i250 i200p/i250p PRESSURE DROP (PSI) 20 15 10 5 0-5 0 1 2 3 FLOW RATE (GPM) 4 5 6 7 46.2 34.7 23.1 11.6 0-11.6 PRESSURE DROP (Ft of Head) Clearances Side Back Top Side Required Mounting Clearances Location From From Non- Service Combustibles Combustibles Clearance 1 Top 6" (15.2cm) 20" (50.8cm) 12" (30.4cm) Back 2 5/8" (15.8mm) 5/8" (15.8mm) 5/8" (15.8mm) Sides 1" (25.4mm) 1/2" (12.7mm) 5/8" (15.8mm) Front 2" (5.1cm) 2" (5.1cm) 30" (76.2cm) Bottom 12" (30.4cm) 12" (30.4cm) 12" (30.4cm) 1 Service clearances are suggested to allow for normal service 2 Mounting bracket automatically sets this dimension Front Bottom Electrical Data Electrical power required for the water heater is 120V AC, 60 Hz. The circuit breaker shall be a minimum of 15 amps. Only one water heater should be plugged into an outlet. Please ensure correct polarity of outlet before plugging in heater
Venting Maximum Vent Lengths (ft) Number Of Units 1 2 3 4 5 6 7 8 9 10 Duct Venting 2" 3" 4" 6" 8" Size Type Model i200 i200 i250 i200 i250 i200 i250 i200 i250 1 Pipe-PV 26 200 130 200 130 2 Pipe-DV 21 100 65 100 65 1 Pipe-PV 100 30 200 130 2 Pipe-DV 50 30 100 65 1 Pipe-PV 150 45 2 Pipe-DV 75 45 1 Pipe-PV 100 30 200 130 2 Pipe-DV 50 30 100 65 Note: Reduce the maximum equivalent length above by 5 feet per 90 elbow and by 2 feet per 45 elbow. Do not exceed above limits. Exhaust Intake Air Exhaust Intake Air Single Pipe-Power Vent (PV) 2-Pipe-Direct Vent (DV)
Dimensional Specifications MOUNTING WALL SURFACE 14 7 8 " 14 5 7 13 4 5 8 " 9 1 5 8 " 17 3 8 " 26" POWER CORD CONDENSATE DRAIN BOTTOM MOUNTING BRACKET 6 5 8 " SIDE VIEW FRONT VIEW 14 7 GAS INLET EXHAUST PORT 3" HOT WATER OUT 8 7 8 " 2 3 4 " FRESH AIR INTAKE 3" 4 5 8 " 7 13 POWER CORD 6 1 13 1 2 " TOP VIEW COLD WATER IN 2 7 2 3 8 " BOTTOM VIEW BOT TEM VIEW CONDENSATE DRAIN 1"
Specifications PARAMETERS MODEL i200, i200p i250, i250p Type Fuel Indoor, Wall-Hung, Fully Condensing, Direct Ignition Preset for NG / LP Convertible Minimum / Maximum Input (Btu/h) 30,000 / 199,950 30,000 / 250,000 Thermal Efficiency 94% 92% Energy Factor 0.93 N/A Dimensions H X W X D (inches) Weight Water and Gas Connections Minimum Flow Rate Venting Materials 26 X 17.4 X 14.9 (3.9 cu. ft) P models - 98 lbs / Non P models - 93 lbs 3/4" NPT P models - No min. flow / Non P models - 0.6 GPM Sch. 40 PVC, Sch. 40 CPVC, Polypropylene, Stainless Steel Max 3 Vent Length - Single Pipe / Power Vent 200 ft, deduct 5 ft per 90 elbow 130 ft, deduct 5 ft per 90 elbow Max 3 Vent Length - Two Pipe / Direct Vent 100 ft, deduct 5 ft per 90 elbow 65 ft, deduct 5 ft per 90 elbow Max 2 Vent Length - Single Pipe / Power Vent 26 ft, deduct 5 ft per 90 elbow N/A (2 not allowed at elevations above 4,000 ft) Max 2 Vent Length - Two Pipe / Direct Vent (2 not allowed at elevations above 4,000 ft) 21 ft, deduct 5 ft per 90 elbow N/A Safety Flame Rod, Thermal Fuse, Overheat Prevention Device, Fan Speed Monitor, Flue Temperature Monitor, Blocked Vent Detector, Water Shut-Off Valve, 2X10A Fuse, Dual Flame Sensing Water Pressure Min / Max (PSI) 30 / 150 NG/LP - Minimum Static Gas Pressure 1/2 Black Iron (non-corrugated) 5 6 NG/LP - Minimum Static Gas Pressure 3/4 Black Iron 2.5 (non-corrugated) NG/LP - Minimum Dynamic Pressure at Full Firing Rate NG/LP - Maximum Static Gas Pressure Gas Pressure for Adjustments Electrical Power Consumption 0.5 14 8 for NG, 11 for LP 120V AC, 60 Hz 500W (Max 4.2 Amps), 8W (Standby) FEATURES & PERFORMANCE i200, i200p i250, i250p Recirculation Cascading Heat Exchanger Built-in Pump for P models Masterless, 10 units Stainless 316L Hot Water Capacity (35F Rise) 10.8 13.2 Hot Water Capacity (45F Rise) 8.4 10.3 Hot Water Capacity (77F Rise) 5.0 6.0 Domestic Hot Water Temperature Settings 100 185 F WARRANTY Residential: Heat Exchanger Coil 15 years, Parts 5 years, Labor 1 year Commercial: Heat Exchanger Coil 6 years, Parts 1 year Note: Due to Intellihot s policy of continuous product improvements, design and technical specifications are subject to change without notice. 02/18/16 Intellihot Green Technologies Inc. 2900 W. Main Street, Galesburg, IL 61401 phone: 877.835.1705 email: sales@intellihot.com www.intellihot.com *i200 & i200p