HT4700 Heating Jacket Instruction Manual

Similar documents
Oil and Water Retort Instruction Manual

Model 165AT Atmospheric Consistometer Instruction Manual

SuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044

Portable Roller Oven (115 Volt) (230 Volt) Instruction Manual. Updated 8/11/2015 Ver. 3.0

JENCO ELECTRONICS, LTD.

HotPoly Tote Tank / IBC Heaters (TTH Series)

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

P/N CC-100. Coolant Circulator. Operation manual

MK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Feniex Hammer S Distributed By: Feniex Hammer Instruction Manual / feniex.com

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Portable Roller Oven. Features

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual V.2. This instruction manual serves as a guide for the Storm Pro.

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

OG5000 Ozone Generator Model OG5000B-A. User Manual

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

MK-660 tile saw OWNER'S MANUAL PARTS LIST & OPERATING INSTRUCTIONS

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Owner s Manual PCS PRO

Spy model 673 wet sponge holiday detector ope rati ng instructions

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

TS0 Series Portable Bulb and Capillary

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

Model CAC 500M Media Air Cleaner

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

6502B RF Distribution

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

Cavitator Ultrasonic Cleaners

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

PORT700CF Portable Fume Collector

TECHNICAL BULLETIN ACCESSORY INFORMATION NU-984 FORMALIN/AMMONIA VAPORIZER

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

TL-105 COLUMN HEATER

Reacti-Therm I and III Heating Modules

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

USER S OPERATING AND INSTRUCTION MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT-900. HCT-900 User Guide _C

Eldex Column Heater. Operator s Manual

Cincinnati, OH USA

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

Reacti-Therm I and III Heating/Stirring Modules

Instruction Manual. Double Candy Apple Cooker

BD Viper Lysing Heater Manual (for BD Viper System)

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Installation and Operation Manual

Mud Pump (Emsco Type) Diesel Engine

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

PREISER SCIENTIFIC. Operating Instructions For. Z V/60Hz Air Drying Oven

QB1000 series OWNER S GUIDE. Professional. Master Prep. ninjakitchen.com

Note To The User: This product has updated features not yet mentioned in the product manual.

OWNER S GUIDE

Typhoon Full Function C-4017

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

(HSTAT Series) Instruction Manual

AUC Cell Washer. User Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

Intrinsically Safe Transmitters, Option Code 2n

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

OPERATING INSTRUCTIONS. EchoThermJ ANALOG MULTI-POSITION STIRRERS AND STIRRING HOT PLATES. Document Number HS15-01 Revised May 20, 2011

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Typhoon Full Function C-4017

NJ100 Series OWNER S GUIDE. Express Chop

Type 750HT Flux Rebaking Ovens

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

301-P2000. Humidifier Heater, 115V. Instructions for Use. Pegasus Research Corporation, 1518 E Edinger Ave., Unit A, Santa Ana, CA 92705

Instruction Manual. Portion Cup Cheese Warmer

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

EQUIPMENT Operation Manual

nova extreme retrofit High Output T5 Lighting Kit

DOWNDRAFT TABLE SERIES SCT

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Model PVIV-VAC-CHUCK

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Installation & Maintenance Guide

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Hydraulic Residential Elevator OWNER S MANUAL

3-in-1 Cooking System

Hot Dog Roller Grills

INSTALLER S & OWNER S MANUAL

WHOLE HOUSE FILTER &

Instruction Manual. Bucket Oil Pump

Transcription:

HT4700 Heating Jacket Instruction Manual Manual No. 102196632, Revision C Instrument No. 101631160

HT4700 Heating Jacket Instruction Manual 2013 Fann Instrument Company Houston, Texas, USA All rights reserved. No part of this work covered by the copyright hereon may be reproduced or copied in any form or by any means (graphic, electronic, or mechanical) without first receiving the written permission of Fann Instrument Company, Houston, Texas, USA. Printed in USA. The information contained in this document includes concepts, methods, and apparatus which may be covered by U.S. Patents. Fann Instrument Company reserves the right to make improvements in design, construction, and appearance of our products without prior notice. FANN and the FANN logo are registered trademarks of Fann Instrument Company in the United States and/or other countries. All other trademarks mentioned in the operating instructions are the exclusive property of the respective manufacturers. Contact FANN Phone TELEPHONE: 281-871-4482 TOLL FREE: 800-347-0450 FAX: 281-871-4358 Mail Fann Instrument Company P.O. Box 4350 Houston, Texas, 77210 USA Location Fann Instrument Company 15112 Morales Rd Gate 7 Houston, Texas, 77032, USA Online www.fann.com fannmail@fann.com 102196632 Revision C, January 2013 2

Table of Contents 1 Introduction... 4 1.1 Document Conventions... 4 2 Safety... 6 3 Features and Specifications... 7 4 Basic Operation... 9 5 Parts List... 11 6 Warranty and Returns... 12 6.1 Warranty... 12 6.2 Returns... 12 List of Figures Figure 3-1 HT4700 Heating Jacket with Filter Press Assembly... 8 Figure 3-2 HT4700 Back View... 8 Figure 4-1 HT4700 Control Panel... 9 List of Tables Table 3-1 HT4700 Heating Jacket Specifications... 7 Table 5-1 HT4700 Heating Jacket Assembly, P/N 101631160... 11 Table 5-2 HPHT Filter Press Model 4700... 11 102196632 Revision C, January 2013 3

1 Introduction The HT4700 Heating Jacket provides heating in fluid loss tests at temperatures up to 350 o F (177 o C). This heating jacket holds a 175 ml sample cell. A fluid loss test simulates filtration against a permeable formation at high temperatures and pressures. Measuring filtration properties of drilling fluids, cement slurries, and fracturing fluids and observing filtrate and filter cake characteristics is fundamental to the design and treatment of fluids and cement slurries. This heating jacket is designed for safe and efficient testing that meets API specifications. 1.1 Document Conventions The following icons are used as necessary in this manual. NOTE. Notes emphasize additional information that may be useful to the reader. CAUTION. Describes a situation or practice that requires operator awareness or action in order to avoid undesirable consequences. MANDATORY ACTION. Gives directions that, if not observed, could result in loss of data or in damage to equipment. WARNING! Describes an unsafe condition or practice that if not corrected, could result in personal injury or threat to health. 102196632 Revision C, January 2013 4

ELECTRICITY WARNING! Alerts the operator that there is risk of electric shock. HOT SURFACE! Alerts the operator that there is a hot surface and that there is risk of getting burned if the surface is touched. 102196632 Revision C, January 2013 5

2 Safety Safe laboratory practices and procedures should be observed while operating and maintaining the HT4700 Heating Jacket. The heating jacket and sample cell are hot during operation. Be aware of hot areas and avoid contact with them. This heating jacket should always be used on a grounded circuit. Electrical connections to and from this heating jacket should be properly insulated and must not be compromised. 102196632 Revision C, January 2013 6

3 Features and Specifications The HT4700 Heating Jacket is designed for safe and efficient heating. This heating jacket is insulated to maintain the maximum temperature inside with minimum heat loss. During operation, the surface temperature of the heating jacket is less than 150 o F (65.5 o C). The primary features of this heating jacket are as follows: Digital Temperature Controller for the heater Digital Temperature Indicator for the cell Lock & Release Knob to secure the cell in place, increasing heat transfer Data Port for Logging (data logger not included) Cell Thermocouple Heater ON/OFF Switch Table 3-1 HT4700 Heating Jacket Specifications Category Specification Maximum Temperature 350 o F (177 o C) Sample Cell Volume 175 ml Heating Capacity 400 watts Power Requirement 115/230 VAC, 1000 watts Dimensions L x W x D 12 x 12 x 17.8 in. 30.5 x 30.5 x 45 cm Weight 34 lb (15.4 kg) The HT4700 Heating Jacket Assembly includes Type J thermocouple and power cables, 115V and 230V. HT4700 Filter Press Assemblies are available and include the heating jacket, filter press cell, and pressurizing assemblies. See Section 5 Parts List for ordering. 102196632 Revision C, January 2013 7

CO 2 Pressurizing Assembly Thermocouple Jack HTHP Filter Press Cell Lock & Release Knob Cell Temperature Indicator Backpressure Assembly Heater Temperature Controller Heater ON/OFF Figure 3-1 HT4700 Heating Jacket with Filter Press Assembly 10 amp Circuit Breaker 5 amp Circuit Breaker Main Power Inlet & ON/OFF Switch Voltage Selector Data Port Figure 3-2 HT4700 Back View 102196632 Revision C, January 2013 8

4 Basic Operation The basic operating instructions for the HT4700 are provided in this section. Follow API Recommended Practice for drilling fluids tests. Cell Temperature Thermocouple Heater ON/OFF Heater Present Temperature Heater Setpoint Temperature Figure 4-1 HT4700 Control Panel 1. Set the Voltage Selector to proper voltage, and then connect the HT4700 power cord to power outlet. See the back panel in Figure 3-2. 2. Turn on the Main Power Switch (back panel). 3. Connect the thermocouple probe as shown in Figure 4-1. 4. On the heater temperature controller, use the up or down buttons to set the desired temperature. The current temperature will be displayed in larger digits on the display. The setpoint temperature will be displayed in the lower right corner (smaller digits). 5. Turn the Heater Switch to the ON position. The heater temperature will rise to the setpoint temperature and remain constant. 102196632 Revision C, January 2013 9

6. Place the cell into the heating jacket. Insert the thermocouple into the cell to monitor the cell temperature. You may need to increase the heater setpoint temperature to get the desired cell temperature. 7. When the test ends, turn OFF the Heater Switch to begin cooling the heating jacket. Also, set the temperature to below ambient temperature by using the up/down buttons on the heater temperature controller. 8. To shut off the power, ensure that the Heater Switch is OFF and turn OFF the Main Power Switch. During operation, the heating jacket s top and bottom surfaces near the cell will be hot. There is risk of getting burned if these surfaces or the cell are touched. 102196632 Revision C, January 2013 10

5 Parts List For service and repair, contact Fann Instrument Company. The HT4700 Heating Jacket assembly includes the parts listed in Table 5-1. Table 5-1 HT4700 Heating Jacket Assembly, P/N 101631160 Part No. Description 208452 POWER CABLE, 115V 208865 POWER CABLE, 230V 102067614 TYPE J THERMOCOUPLE Table 5-2 lists the HT4700 Filter Press assemblies, which include the HT4700 Heating Jacket and various filter press assemblies. Table 5-2 HPHT Filter Press Model 4700 Part No. Cell Pressurizing Assembly 102195986 1800 PSI SINGLE ENDED CO 2 PRESSURIZING ASSEMBLY 15 ML BACKPRESSURE ASSEMBLY 102196306 1800 PSI DOUBLE ENDED CO 2 PRESSURIZING ASSEMBLY 15 ML BACKPRESSURE ASSEMBLY 102197003 1800 PSI DOUBLE ENDED DUAL NITROGEN MANIFOLD 15 ML BACKPRESSURE ASSEMBLY 102197111 1800 PSI SINGLE ENDED DUAL NITROGEN MANIFOLD 15 ML BACKPRESSURE ASSEMBLY CO 2 cartridges are not included with the CO 2 pressurizing assemblies. 102196632 Revision C, January 2013 11

6 Warranty and Returns 6.1 Warranty Fann Instrument Company warrants its products to be free from defects in material and workmanship for a period of 12 months from the time of shipment. If repair or adjustment is necessary, and has not been the result of abuse or misuse within the twelve-month period, please return, freight prepaid, and correction of the defect will be made without charge. Out of warranty products will be repaired for a nominal charge. Please refer to the accompanying warranty statement enclosed with the product. 6.2 Returns For your protection, items being returned must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Fann will not be responsible for damage resulting from careless or insufficient packing. Before returning items for any reason, authorization must be obtained from Fann Instrument Company. When applying for authorization, please include information regarding the reason the items are to be returned. Our correspondence address is: Fann Instrument Company P.O. Box 4350 Houston, Texas USA 77210 Telephone: 281-871-4482 Toll Free: 800-347-0450 FAX: 281-871-4446 Email fannmail@fann.com Our shipping address is: Fann Instrument Company 15112 Morales Road Gate 11, Houston, Texas USA 77032 102196632 Revision C, January 2013 12