W-750-IS Specifications

Similar documents
W-150-IS Specifications

Who Needs BIG DIPPER?

How To Size A Big Dipper Unit

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

Installation & Operation Instructions For Big Dipper Series Automatic Solids Transfer (AST) Units

Innovative, Compact Design

Installation & Operation Instructions For Big Dipper Series Internal Strainer (IS) Units

Automatic Solids Transfer System

THE CLEAR CHOICE FOR CLEANING

CL64T INDUSTRIAL TOTE WASHER

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

1 Exam Prep Plumber s Handbook Tabs and Highlights

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

FT1000 FLIGHT-TYPE DISHWASHER

Used Fluid Handling Portable Used Oil Gravity Drains

Models. Options. Standard Features. LoH 2 O

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

Used Fluid Handling Portable Used-Oil Gravity Drains

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

IMAGE V. Parts and Service Manual

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

FT1000S BASE FLIGHT-TYPE DISHWASHER

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

Lubrication Tools and Equipment Portable Oil Drains

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

VENTLESS DOOR-TYPE DISHWASHER

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Posi-Drain. A non-clogging straight-through flow path design. Removes condensate, (oil and water) from compressed air systems.

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Freeze Dry Systems and Accessories

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Freeze Dry Systems and Accessories

FT900 FLIGHT-TYPE DISHWASHER

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

General Characteristics.3. S.M.A.R.T System Set-up...5. Start-up Procedures.6. Shut-down Procedures 8. General Maintenance..8

Available from. M3 ULTRAf AST. Phone (502) Toll-free (800) Online

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

A B A B4

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

TURBOWASH TM... Pot and Pan Sink

C44A/C44AW DISHWASHER

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

TFC 400. OPERATOR MANUAL Clarke MODEL /09 Rev C Document Number

FT900BD FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

BEFORE OPERATING THE MACHINE: WARNING

Residential Fire Meter

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Standard Features. Performance/Capacities

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Temptek Auxiliary Equipment

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E

6-Gallon Carpet Extractor Series

Partswasher and Workshop Solutions COMMERCIAL

Effectively clean rubber footwear with a BSX Boot Scrubber

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

"ESDDR" Series Electric Humidifier

ELECTRIC SPRAYER OWNER S MANUAL

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

MYTEE PRODUCT GUIDE EXTRACTORS. Revised February FAX ORDERS: CALLS:

Model GW1020 Laboratory Glassware Washer General Specifications

Indirect Fired Water Heater

Raffaello From serial number Group

INTEGRATED CLEANING SYSTEM TOUCHLESS CLEANING SOLUTIONS

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

Commercial Hot Water Maker

TM Series. Induced Draft, Counter Flow Optional Accessories

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Paragon. Induced Draft, Counter Flow Optional Accessories

MODEL 6430T, 6460 & 6460T POTATO PEELER

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

1600 Series Rotating Suction Screen

SYSTEM DESIGN REQUIREMENTS

Canning Shed/Facility Equipment Specifications

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Jabsco Marine Toilets SIMPLY RELIABLE SOLUTIONS FOR EVERY BOAT AND BUDGET

There are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.

Transcription:

Big Dipper IS Central Automatic W-750-IS Specifications MOTOR/TIMER ENCLOSURE 1 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 23.375 EMPTY INTO COOKING OIL RECYCLING CONTAINER DAILY 21.85 GC-7 GREASE COLLECTOR 8 QUART CAPACITY 16.5 16.5 27.1 PIPE / 17.5 END VIEW FEATURES: 42. SIDE VIEW 45. Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with 24- hour timer. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. 23.375 Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. TOP VIEW Easy lift grease collector simplifies grease collection container emptying. Compact footprint. TECHNICAL DATA Materials: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 60 Hz, 520 Watts (4.5 Amps) Maximum Inlet Flow Rate: 75 GPM Number of Skimming Wheels: 1 Skimming Rate: 20 Pounds Per Hour Grease Retention Capacity: 150+ Pounds Internal Solids Strainer Capacity: 3.70 Gallons 1/06 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 1

Big Dipper IS Central Automatic W-750-IS Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions DO... Allow a minimum of 1 clearance from top of tank for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. 6.5 4.5 42. GC-7 GREASE COLLECTOR Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber No Hub connectors. Keep outlet piping as straight as possible. Use only sweep connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DONʼT... Install P trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-750-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 75 gallons per minute peak flow, 150 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 2 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 1/06

MOTOR/TIMER ENCLOSURE 24.5 Big Dipper IS Central Automatic W-1250-IS Specifications 1 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 21.85 21.0 PIPE / DUAL GC-6 GREASE 16.5 COLLECTORS 16.5 6 QUART CAPACITY 26. 17.5 23.5 END VIEW FEATURES: 5.5 52. SIDE VIEW 55. Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with two 24-hour timers. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. 24.5 Integrated Motor/Grease Outlet/Heater/Lids enables fast, do-it-yourself unit operation reversal. TOP VIEW Easy lift grease collectors simplify grease collection container emptying. Compact footprint. TECHNICAL DATA Materials: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 60 Hz, 1040 Watts (9.0 Amps) Maximum Inlet Flow Rate: 125 GPM Number of Skimming Wheels: 2 Skimming Rate: 40 Pounds Per Hour Grease Retention Capacity: 300+ Pounds Internal Solids Strainer Capacity: 3.70 Gallons 1/06 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 3

Big Dipper IS Central Automatic W-1250-IS Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions DO... Allow a minimum of 1 clearance from top of tank for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. 52. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber No Hub connectors. Keep outlet piping as straight as possible. Use only sweep connections. Install vent on outlet piping. GC-6 GREASE COLLECTORS Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DONʼT... Install P trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-1250-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 125 gallons per minute peak flow, 300 pounds of grease capacity and including as an integral part of the unit, two rotating gear hydrophobic wheel assemblies for automatic grease/ oil removal, an integral flow control device, two self-regulating enclosed electric immersion heaters, a vessel vent, an integral gas trap, two integral programmable 24-hour multi-event time controls, field reversible motor locations, field reversible grease/oil sump outlets, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and two separate grease and oils collection containers. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Each electric motor shall be equipped with thermal overload protection with automatically resettable switch. 4 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 1/06

MOTOR/TIMER ENCLOSURE 23.375 Big Dipper AST Central Automatic W-750-AST Specifications 1 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL EMPTY INTO COOKING OIL RECYCLING CONTAINER DAILY 30.25 21.85 21.0 PIPE / GC-7 GREASE 16.5 COLLECTOR 16.5 8 QUART CAPACITY 27.1 1/2 FEMALE NPT WATER SUPPLY CONNECTION FEATURES: 17.5 23.5 END VIEW 5.5 42. SIDE VIEW TO WATER SUPPLY 0.5" FEMALE CONNECTOR 45. Fully automatic self cleaning cycle. Removes collected grease, oils and solids from unit without any operator assistance. Comes complete with 24-hour timer. 29.375 Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. 23.375 Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. TOP VIEW Easy lift grease collector simplifies grease collection container emptying. Compact footprint. TECHNICAL DATA Materials: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 60 Hz, 535 Watts (4.6 Amps) Maximum Inlet Flow Rate: 75 GPM Number of Skimming Wheels: 1 Skimming Rate: 20 Pounds Per Hour Grease Retention Capacity: 150+ Pounds Eductor Pump Operation Requirements: 50 PSI min., 12 GPM 1/06 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 5

Big Dipper AST Central Automatic W-750-AST Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions DO... Allow a minimum of 1 clearance from top of tank for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. 6.5 4.5 42. GC-7 GREASE COLLECTOR Provide a min. 50 PSI, 12 GPM Water Supply for solids pump operation Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber No Hub connectors. Keep outlet piping as straight as possible. Use only sweep connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. DONʼT... Install P trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Set Programmable Time Controller for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-750-AST, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 75 gallons per minute peak flow, 150 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, lift-out filter basket access, an eductor transfer pump controlled by repeat cycle timer, and a separate grease and oils collection container. Eductor pump shall be supplied with a 0.5 female connector for attachment to facilitysupplied water supply. Eductor pump shall be supplied with an approved vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 6 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 1/06

MOTOR/TIMER ENCLOSURE 24.5 Big Dipper AST Central Automatic W-1250-AST Specifications 1 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 30.25 21.85 21 PIPE / 16.5 DUAL GC-6 GREASE COLLECTORS 6 QUART CAPACITY EA. 16.5 27.1 1/2 FEMALE NPT WATER SUPPLY CONNECTION FEATURES: 23.5 17.5 END VIEW 5.5 TO WATER SUPPLY 0.5" FEMALE CONNECTOR 52. SIDE VIEW 55. Fully automatic self cleaning cycle. Removes collected grease, oils & solids from tank without any operator assistance. Comes complete with two 24-hour timers. 24.5 30.5 Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. Integrated Motor/Grease Outlet/Heater/Lids enables fast, do-it-yourself unit operation reversal. TOP VIEW Easy lift grease collectors simplify grease collection container emptying. Compact footprint. TECHNICAL DATA Materials: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 60 Hz, 1055 Watts (9.1 Amps) Maximum Inlet Flow Rate: 125 GPM Number of Skimming Wheels: 2 Skimming Rate: 40 Pounds Per Hour Grease Retention Capacity: 300+ Pounds Eductor Pump Operation Water Requirements: 50 PSI min., 12 GPM 1/06 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 7

Big Dipper AST Central Automatic W-1250-AST Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions DO... Allow a minimum of 1 clearance from top of tank for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. 6.5 4.5 52. GC-6 GREASE COLLECTORS Provide a min. 50 PSI, 12 GPM Water Supply for solids pump operation Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber No Hub connectors. Keep outlet piping as straight as possible. Use only sweep connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. DONʼT... Job Specification: Install P trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Set Programmable Time Controller for proper operating times. Note: Installations must comply with all applicable local, state, and national codes for your area. Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-1250-AST, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 125 gallons per minute peak flow, 300 pounds of grease capacity and including as an integral part of the unit, two rotating gear hydrophobic wheel assemblies for automatic grease/ oil removal, an integral flow control device, two self-regulating enclosed electric immersion heaters, a vessel vent, an integral gas trap, two integral programmable 24-hour multi-event time controls, field reversible motor locations, field reversible grease/oil sump outlets, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, lift-out filter basket access, an eductor transfer pump controlled by repeat cycle timer, and two separate grease and oils collection containers. Eductor pump shall be supplied with a 0.5 female connector for attachment to facility-supplied water supply. Eductor pump shall be supplied with an approved vacuum breaker. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Each electric motor shall be equipped with thermal overload protection with automatically resettable switch. 8 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204 1/06