Multiphase Study on Firefighter Safety and the Deployment of Resources. Kathy Notarianni Jason Averill Lori Moore-Merrell Robert Santos

Similar documents
Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

2013 Compliance Report RCW 52.33

U.S. Department of Commerce Gary Locke, Secretary. National Institute of Standards and Technology Patrick D. Gallagher, Director.

Patrick D. Gallagher, Under Secretary of Commerce for Standards and Technology and Director

Fire FY Performance Plan

CITY OF MOUNTAIN BROOK FIRE DEPARTMENT

WELCOME TO ROSEVILLE UNIVERSITY

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

Assignment Sheet Apply the NIMS-ICS Model to an Emergency Scene

Chapter 2 Study Questions and Research Methods

Canadian Association of Fire Chiefs Steve Thurlow Dillon Consulting Limited. September 21, 2015

FIRE STATION PLACEMENT REVIEW AND RECOMMENDATIONS FOR EXPANSION DES MOINES FIRE DEPARTMENT CITY OF DES MOINES, IOWA

Fire Protection For and With the Fire Service

Enactment Date: Rapid Intervention Team and RIT Officer

NFPA Self Assessment Manual

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

A proposed research project submitted to the Ohio Fire Executive Program

NFPA Who we are and how we can help you

Branch Fire Rescue Services

PEMBROKE PINES FIRE DEPARTMENT ISO Class 1 Department

FIRE AND RESCUE. Intent

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

Road Ecology in Practice: Building Resiliency of Urban Ecosystems through Informed Road Network Planning

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 High Rise On Scene Revised

Carbon Monoxide Poisoning

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Fire Department. Serving the citizens of Waterloo since 1904


Pembroke Pines Fire Department

Rapid Intervention Team

Emergency Responder Program

2017 Annual Report. King County Fire District No. 27 Fall City, WA

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

DEPARTMENT SUMMARY. Personnel Services $ 7,780,971 $ 7,989,600 $ 7,707,680 $ 8,231,680. Operating Expenses 835, , , ,870

CITY OF OWENSBORO OWENSBORO FIRE DEPARTMENT DEPLOYMENT ANALYSIS

This is an incident action status report from the Contra Costa EMS Agency on Fire Station Closures affecting the communities of Lafayette, Martinez,

Services the Agency is Required to Provide Services

FIREFIGHTER STAFFING PER COMPANY: DOES COMPLYING WITH THE NATIONAL GUIDELINE IMPROVE A FIRE DEPARTMENT S PERFORMANCE ENOUGH TO JUSTIFY THE COST?

Brad Goudie May 16, Fire Marshal EMS Emergency Management Fire Department

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

Performance Measurements Compliance Guide for a Substantially Career Fire Department, Fire District and Regional Fire Authority in Washington State

ABNJ Deep Seas Project:

Chapter 3 FF II Fire Department Communications

A Captain Dies and Two Fire Fighters Are Injured in a Motor-Vehicle Crash - Texas

Development and Use of Interdivisional Box Alarm Cards

Telling the Story: Fire Department Response Capability, Performance, and System Resilience

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Citizen Centered Gainesville CITIZENS ACADEMY GAINESVILLE FIRE RESCUE MARCH 21, 2018

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

MINIMUM APPARATUS MANNING LEVELS FOR THE NORTH OLMSTED FIRE DEPARTMENT OHIO FIRE CHIEFS EXECUTIVE FIRE OFFICER PROGRAM

Fire Department Anchorage: Performance. Value. Results.

ANNUAL REPORT 2016 EXCELLENCE THROUGH EACH INDIVIDUAL ACT

AMADOR FIRE PROTECTION DISTRICT

PUBLIC SAFETY Nanaimo Fire Rescue 2019 Business Plan

Service Business Plan

El Mirage Fire Department

Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

CURRICULUM VITAE STEVEN J. MOORE, CFI

Answer: B Objective: NFPA 472, (c), 4.2.3, 5.2.3(1); Level: Awareness, Operations Subject: Introduction; Chapter 1; Page 5

Economic Impact of Building Regulations

This page was intentionally left blank

SUMTER COUNTY, FLORIDA Fire Rescue Strategic Planning. Matrix Consulting Group

CAMDEN COUNTY FIRE COORDINATOR

BERKELEY FIRE DEPARTMENT (141 FTE)

2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

2017 Eastside Fire & Rescue Response Coverage Report

Program of Instruction Course Syllabus

City of Quincy, IL Fire Station Location Study March 2017

A Strategic Plan By Steamboat Springs Fire Rescue September 2018

SMALL TOOL REPLACEMENT PLAN

City of Santa Ana Fire Services Month End Report February 2017

Logistics/Support Services

Volunteer Fire Fighter Killed Rescuing Injured Construction Worker When Struck by Collapsing Cell Phone Tower West Virginia Executive Summary

Pebble Beach Community Services District Fire Department 3101 Forest Lake Road, Pebble Beach, CA

HYDROGEN EMERGENCY RESPONSE TRAINING FOR FIRST RESPONDERS

Report of the 2 nd National Fire Service Research Agenda Symposium May 20-22, 2011 National Fire Academy

Prevention Mini-Summit January 13, 2007 Washington, D.C.

Required Materials For complete material(s) information, refer to

STANDARD OF COVER DEPOE BAY RFPD

Branch Fire Rescue Services

PRINCE WILLIAM COUNTY FIRE AND RESCUE ASSOCIATION RESOLUTION LOG

MINIMUM MANNING IN THE PORTSMOUTH FIRE, RESCUE, & EMERGENCY SERVICES EXECUTIVE DEVELOPMENT. Brian Spicer, Training Captain. Portsmouth, Virginia

MASTER COURSE OUTLINE

1 Pre-Burn Plan Mandatory. 2 Pre-Burn Inspection Mandatory. 3 Pre-Burn Briefing Mandatory. 4 Instructor In Charge Mandatory

Porterville Fire Department 2011 Annual Report

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

Smart Growth for Dallas

Radio Communications Guideline

Easton Fire & Rescue Department Budget Fiscal Year 2017

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

Working together for a safer Scotland LOCAL FIRE AND RESCUE PLAN FOR SOUTH LANARKSHIRE

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Pembroke Pines Fire Department ISO Class Annual Report

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

City of Los Angeles Office of the Controller

Transcription:

Multiphase Study on Firefighter Safety and the Deployment of Resources Kathy Notarianni Jason Averill Lori Moore-Merrell Robert Santos

Why Operations Research? THE INCIDENT At 0135 hours, firefighters received a call of a reported structure fire. Engines 5, 2, 1, Truck 11 and Rescue 32 responded. Engine 5 arrived at 0141 hours (6 minutes after dispatch) and reported a well-involved house fire. A Captain and 2 firefighters advanced an 1 ¾- inch hand line through the front door and down a hallway. They notice heavy fire off to the right. There was a flashover in the room and as the firefighters attempted to exit, the hallway became heavily involved with fire. Only two made it out. 56 minutes later a firefighter was found inside and pronounced dead at the scene.

Why Operations Research? NIOSH investigation/recommendations: Consider increasing the number of firefighters on engine companies to perform in accordance with NFPA standards Ensure a RIT is established when firefighters enter a structure Study looks at the many operational factors that could have led to a different outcome.

Project Objectives Optimize a fire service leader s capability to deploy resources to prevent or mitigate adverse events that occur in an risk/hazard filled environment.

Study Phases Develop a scientifically-based community risk assessment and resource deployment model; Conduct field experiments to assess resource deployment including crew size and time to task analysis; and Develop performance evaluation tools to be used by departments to assess how well they match their community risk level to resources deployed.

Project GANTT Chart 2006 2007 2008 2009

Last Year We Reported Stakeholder Engagement Evaluation of Community Risk Software (RHAVE) Expert Elicitation Literature Review Model Framework Website Launched Laboratory Experiments

Since then Annotated Bibliography Survey Design and Development Sample design and selection Web survey development Survey testing Field Experiments Burn Prop Construction

Annotated Bibliography Copy on CD www.firereporting.org

Survey Design Objectives: Fire & ALS Models Unit of Analysis Events Capture full range of responses How many to sample? How to gather the data? How Many: Power Analyses (Sample Size) 2-sided test of difference of means, 5% significance and 80% power Reflected clustering effects within departments How to: 2-stage Design Departments Events within departments

Survey Design Cumulative % Distribution of Population Served 100% 90% Percent of Popoulation Served Accounted For 80% 70% 60% 50% 40% 30% 20% 10% 0% 1 212 423 634 845 1056126714781689190021112322253327442955316633773588379940104221443246434854506552765487569859096120 Departments

Survey Design Department Sample 400 Departments Probability proportional to size Departments selected and notified Event Sampling 100 Fire & 100 ALS events per department 6 months data collection

Website

Website: Surveys

Survey Status Cognitive Testing Pilot testing Usability Testing Training Manual Developed Web-X Training Deployment Pending

Field Experiments Fire Two story, 2,000 sf residential response Comply with NFPA 1403 Technical foundation for NFPA 1710 Depth-of-understanding for survey findings Crew Size Response Time Fire Growth Rate

Burn Prop

Site Plan

Site Plan

Field Experiments EMS Basic system and extremity trauma Cardiac arrhythmia and arrest Interactive Harvey mannequin Depth-of-understanding for survey findings Training Response Time Incident Type

We Plan to Phase 3 Pending Funding Model and GUI Version Validation and Verification Exercises Final Report and Model Documentation and Delivery Educational Materials for fire and EMS operations

Final Message The intent of the study is to determine how well the fire service decision makers match resources to risks and what factors are important in making better decisions about these matches in the future recognizing that decisions must be made in light of available funding in the community and the level of service the community expects. The overall goal is to reduce firefighter injury and death by making better decisions about resource deployment in a risk filled environment.

Questions or Comments