Operation Manual Digital Heating Hotplate HP-1D

Similar documents
Operation manual for BOD-80. 3, Hagavish st., Holon,Israel Tel: , Fax: Page 1 of 6 pages

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

Magnetic Stirring Systems with Heat

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating/Stirring Modules

MD-MINI Dry Bath. Instruction Manual

BATHS STIRRERS HOTPLATES HEATING MANTLES HOTPLATES

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Dry Bath Heating Systems

MS200/300/400 Magnetic Stirrer. Instruction Manual

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

CG Series Digital Temperature Controller OPERATIONS MANUAL

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

User Manual. Digital Hotplate. HP RT2 Basic. Operation Manual

Far-infrared method Pre-Heater

TEMPERATURE CONTROLLER (STANDARD MODEL)

Ingenieurbüro M.ZippererGmbH

Digital Heat Block User Manual

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand :

600mm INDUCTION Cooktop

TRUE INDUCTION DOUBLE BURNER TI-2B COUNTER INSET INDUCTION COOKTOP MANUAL

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

TRUE INDUCTION DOUBLE BURNER MINI DUO COOKTOP MANUAL

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

DOUBLE BURNER TI-2BN INDUCTION COOKTOP MANUAL

High Power Range Hood

TRUE INDUCTION DOUBLE BURNER TI-2C PORTABLE INDUCTION COOKTOP MANUAL

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

PS-3401 Heater / Stirrer

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digital 7 Square Plate Magnetic Stirrer

CLOSEDRIER USER GUIDE

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Safe Operation Manual. Honeywell IQ Force Gas Detector

Mixer with Lifting Cart STANDARD OPERATING PROCEDURE

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

USERS MANUAL FOR GAS BOILERS

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

2-IN-1 UPRIGHT HANDHELD VACUUM CLEANER INSTRUCTION MANUAL

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

2 Wire Nuts (or other approved wire connectors) (Field-supplied) Push Button(s) Phillips Head Screwdriver (Field-supplied) Control-R Module

POT-100C / POT-102C POT-200C /POT-202C

Please read this manual before switching the unit on. Important safety information inside. Dry - Well Temperature Calibrator.

DOUBLE BURNER COUNTER INSET. User Guide

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

This policy is applicable to all DMS-owned, -leased and -managed facilities.

LABORATORY SAFETY. Discipline of Metallurgy Engineering and Materials Science Indian Institute of Technology (IIT) Indore DECLARATION

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

TRUE INDUCTION GAS COMBO COOKTOP MANUAL

Reflux Extractor BM106. Impact Test Equipment Ltd & User Guide. User Guide

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

User Manual. Ceramic Cooktop Model : CRSF745

PWASH Gallon Parts Washer Assembly & Operating Instructions

BIX B-One 100 kw INSTALLATION GUIDE

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Kamikaze Hot Plates Hot plates that heat when off or heat too much.

User Manual. Moisture Analyzer HE53

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

User manual. Logano GC 124 II. Gas boiler

QuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc. REV C

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Green Chemistry Safety Training PSE/CH 335. Departments of Forest Biomaterials and Chemistry North Carolina State University

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

Refrigerant Leak Detector

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

StableTemp Hotplates, Stirrers and Stirring Hotplates

Safety In Chemistry. Identified Risks and Hazards

WSU-TFREC Fire Safety Training

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

Hotplate/stirrers. Hotplate stirrers

USER INSTRUCTION MANUAL ACR Alarm Clock Radio Instruction Manual (Read before proceeding)

HERMS (Heat Exchanger Recirculating Mash System) Controller

ITEM # MEG300. Electric Meat Grinder Assembly & Operating Instructions

TEMPERATURE CONTROLLER R/S (ADVANCED MODEL)

Operate the Mutli-Gas Monitor PID

Infrared Moisture Determination Balance FD-610. Operating Manual

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

DOUBLE PLATE INDUCTION COOKER. Model A 2006 (S2-L2)

MODELS 304GC, 304GCX, 314GC, and 314GCX

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

MICRO CONTROLLER S Z SERIES

Transcription:

Operation Manual Digital Heating Hotplate HP-1D Before you operate the hot plate with external temperature probe, make sure that the external probe will be constantly soaked in your sample and not in the air, to avoid serious damage to the plate

IMPORTANT SAFETY INSTRUCTIONS: WARNING 1. Do not heat any substances above temperature which will cause hazards of explosion, implosion or release of toxic or flammable gases from the material being heated 2. Do not use in the presence of flammable or combustible materials, or explosive gases 3. Do not use in the presence of pressurized or sealed containers. Fire or explosion may result causing injury or death 4. Do not operate the hot plate on EXTERNAL mode, while the external sensor is "on air ", always make sure that the sensor is immersed inside the liquid. 5. To avoid electric shock, always use a property grounded electrical outlet of correct voltage, and correct handling capacity equipment 6. The user shall be aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 7. The instrument should be placed so, that handy operation of the ON- OFF Switch is possible. Service only by a qualified Service engineer. 8. Always disconnect from power supply prior to maintenance and servicing. 9. The instrument may be hot to touch, even when the pilot light is off 10. Connect the instrument to a ground mains outlet, after ensuring that the Voltage is the same as given on the name plate 11. The Instrument must be connected to an earthen (grounded) supply. Cleaning: To keep the plate clean you can use aluminum paper you can cover the hot plate only but not the cooling plates under it. No use of caustic soda in cleaning reagent Please read the following carefully before use: Do not use this product in a manner other than as stated in the Operating Conditions section of this manual as the protection provided by the equipment may be impaired. The plate temperature might remain dangerously high even after the heater was turned off. Don t touch the plate and/or place any objects on top of it that are not meant to be heated. This product is designed for use in laboratory environments by persons knowledgeable in safe laboratory practices. Always wear safety glasses and other appropriate protective equipment when operating this product.

The plate might be covered with aluminum foil to protect it, DO NOT cover any other part of the device and make sure that the radiation sheets underneath are untouched. The Aluminum topped plates are not designed to be used with metal containers. For heating of such containers it s advisable to use a ceramic top hot plate. Connect only to grounded power source, make sure the voltage and frequency of your electrical outlet fits the requirements labeled on the device. Do not use in areas with explosive atmosphere, flammable/combustible liquids etc. Do not overweight the plate. Before cleaning the device, make sure to disconnect it from the power source. Do not immerse the product in any liquid. Position the product for use so that the power cord can be easily disconnected without having to move the product. Heating Operation Principles The heating element and a temperature sensor are located just beneath the top surface of the product. The microprocessor is responsible for regulating the heating produced by the heating element right beneath the plate surface. The microprocessor work is based upon the sensor temperature and the value set on the Heating Temperature Display. When the sensor temperature is not within range of the value set on the display, the display will FLASH. When the sensor temperature is within range, the value displayed will remain constantly ON. The Heating Temperature Display does not indicate the actual temperature of materials placed on top of the product or the actual temperature of the top surface.

General view

Components description: Temperature Digital Controller Control the temperature ON/OFF switch turn on the plate with this switch Heating indicator when the heating is activated this LED light on or blinking Main power cord for outlet connection External K sensor While working in an external mode connect the K sensor to this socket (the external sensor is optional) Base for stand/pole (optional) 2132 Digital controller To insert your temperature set point press on the "raise" or the "lower" button Remark: Don t change any other parameters in the 2132 controller except from your temperature set point or AUTO TUNE procedure

Operation instruction: Working with the built-in Internal sensor Verify that the back plug of the K sensor is connected well to the back K socket with the correct polarity Turn on the main switch Insert your temperature set point in the controller with the arrows Wait for temperature stabilization Working with External sensor (optional) Connect the external sensor to the back socket instead of the built-in one (verify the correct polarity) Put glassware with liquid on the plate surface Put the external sensor in the glassware Turn on the main switch Insert your temperature set point in the controller with the arrows Wait for temperature stabilization

Appendix 2132 AUTO TUNE procedure: Explanation: Temperature control using digital PID controllers have automatic auto-tune functions. During the auto-tune period the PID controller controls the power to the process and measures the rate of change, overshoot and response time of the plant. This is often based on the Zeigler-Nichols method of calculating controller term values. Once the auto-tune period is completed the P, I &D values are stored and used by the PID controller. Use AT function to automatically calculate and set the optimize PID value for your system Procedure: If you have an overshooting do as follows: Enter your temperature set point on the 2132 controller Press several times on the "PAGE" button until "Atun" Press on the" Scroll" button one time until "tune" Change "OFF" to "ON" with the "RAISE" arrow & wait 2 second Press several times on the "PAGE" button to exit to the main Manu From this point the "tune" will blinking on the screen Don t touch the controller and wait until the procedure to be finished (This procedure should be taken a certain time please wait)