BB3000 Series. Application. Features. Injection Pump Control General Instructions

Similar documents
TAC Erie VL500. Application. Features. Zone Valve Control Center General Instructions

Schneider Electric Erie T155 Series

CP CP

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

B-40/B-41 Modulating Temperature Controller

TC-5231 Series, TC-5232, & TC-5241 Series

- Data Brochure Boiler Control 274

Outdoor Reset IQ Option Card, p/n

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

- Data Brochure D 260. Boiler Control /09

- Data Brochure Universal Reset Module 422

- Data Brochure Steam Control 279

- Data Brochure Boiler Control 264e

Outdoor Reset IQ Option Card, p/n

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

- Essay Control Functions and Benefits

- Data Brochure Mixing Control 360

- Data Brochure Mixing Control 361

Installation & Operation Manual

Erie WA300. Application. Features. Two Zone Hydro-Air Relay General Instructions

- Data Brochure Universal Reset Module 423

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

c0094 form 2. Project Identification Year: 2001 Project nº: 910

MR3CCUHV Temperature/Defrost Control

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

- Data Brochure Boiler Control 268

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

- Data Brochure Boiler Control 264

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Installation Instructions

Heat Link. Technical Guide

Installation & Operation Manual

Installation & Operation Manual

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

AQ252 Universal Injection/Mixing Boiler Reset Control Panels

INSTALLATION/OPERATING INSTRUCTIONS HEAT-TROL Elite Series. HWE-Motorized Valve

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SAFETY INFORMATION AND WARNINGS

prestige Control Application Supplement WARNING

SSV-DC user manual. Phason

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

TEMPERATURE CONTROLLER (STANDARD MODEL)

- Data Brochure Universal Reset Control 364

Instruction Sheet X Pump Block (XPB)

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ProRadiant Basic Heating Control Installation Manual 2013

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

- Data Brochure Addendum

Hydronic Mechanical Panels

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

BGH Series Hot Surface Ignition Control

prestige Control Application Supplement - TriMax

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

qualified heating installer/service technician

Radiant Mixing Block

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

- Data Brochure Addendum

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

WARNING Important Safety Information

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

EW 40 Wireless Fan Control

Analog Room Pressure Monitor RPC Series

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Transcription:

BB3000 Series Injection Pump Control General Instructions Application The TAC Erie BB3000 Injection Pump Control with outdoor reset provides accurate control of the water temperature in the secondary (radiant) loop of a heating system, using an injection pump. The BB3000 also protects against boiler condensation by monitoring and anticipating the boiler return water temperature in the primary loop. The outdoor air and loop temperatures are sequentially displayed, along with the secondary loop setpoint and injection pump speed. Features Microprocessor control Built-in transformer and relays Real application data inputs Large, bright display and indicators Boiler short cycle and low temperature protection Sure start pump control Priority override BB3000 Injection Pump Control Printed in U.S.A. 8-08 Copyright 2008 TAC All Rights Reserved. F-27030-2

SPECIFICATIONS Inputs Outputs Environment Regulatory Agencies Line Voltage External Power Supply (L1-N/L2): Switch selectable 115/230 Vac, 50/60 Hz, 6 VA. Connections: Screw terminals, 12 to16 AWG copper wire only. Power supply wiring must be adequately sized for the sum of all line voltage loads. Earth ground to enclosure ground screw. Main Fuse (F1): 250 V 5 A slow blow 5 x 20 mm (T5AL). Low Voltage Heat Demand Input (T1-T2): Normally open dry contact, Class 2, 24 Vac, 8 ma. Connections: Lever terminals, 14 to 24 AWG copper wire. Priority Zone Input (P1-P2): Normally open dry contact, Class 2, 24 Vdc, 8 ma. Connections: Lever terminals, 14 to 24 AWG copper wire. Temperature Sensors (OA1-OA2, PL1-PL2, SL1-SL2): Three thermistors (included), 10k @ 77 F (25 C), -60 to 221 F (-51 to 105 C), Class 2, 5 Vdc. Connections: Lever terminals, 14 to 24 AWG copper wire. Line Voltage Injection Pump (L1-N/L2): Phase-controlled triac at line voltage, 2.0 A @ 115/230 Vac. Connections: Screw terminals, 12 to 18 AWG copper wire only. Secondary Circulator (C1-C2): Normally open relay contact (dry contact), 1/3 HP @ 115 Vac, 1/2 HP @ 230 Vac. Connections: Screw terminals, 12 to 14 AWG copper wire only. Circulator Fuse (F2): 250 V 10 A slow blow 5 x 20 mm (T10AL). Low Voltage Boiler control signal (X1-X2): Normally open relay contact (dry contact), Class 2, 24 Vac, Pilot duty 75 VA. Connections: Lever terminals, 14 to 24 AWG copper wire. Temperature Limits: Shipping & Storage: -20 to 140 F (-29 to 60 C). Operating: 40 to 104 F (4 to 40 C). Humidity: Up to 95% RH, non-condensing. Location: NEMA Type 1(IP 23), solid wall, away from heat source and direct sun. FCC: Tested To Comply With FCC Part 15, Subpart B. 2 Copyright 2008 TAC All Rights Reserved. F-27030-2

TYPICAL APPLICATIONS T T Boiler BOILER Dry Contacts X2 X1 Caution: Select Line Voltage Before Wiring MAIN FUSE 250V 5A SLOW BLOW 115V 230V F1 BB3000 Made in USA Outside OAL Air-Low 0-20 -30 10-40 20-50 30-60 40 250V 10A SLOW BLOW CIRC. F2 FUSE L1 N/L2 C1 C2 L1 N/L2 45 40 50 OAH Outside Air-High 55 60 65 70 Heat Demand Test/ Reset T1 T2 60 Cold Start PLL Primary Loop-Low 80 90 100 110 120 70 130 Circ. Boiler WWSD Priority SLH Secondary Loop-High SLL Secondary Loop-Low 130 140150 90 160 85 95 120 170 80 100 110 180 140 100 75 190 105 150 90 200 70 110 P1 P2 Display Temp. Scale t F C Pump Exercise PE On Off OA1 OA2 PL1 PL2 SL1 SL2 115/230V 50/60 Hz Dry Contacts INJECTION CIRCULATOR PUMP Use Copper Conductors Only HEAT DEMAND L1 t o L1 N/L2 N/L2 InjectionPump Thermostat, Power Supply End Switch 1 Caution: Set voltage or Relay switch above fuse N.O. Dry Contact PRIORITY ZONE t o DHW or Relay Contact Outdoor Air SENSORS Primary Loop Return Secondary Loop Supply 1 CAUTION: Ciruclator output is a dry contact. Connect in series with load as shown. See Wiring instructions. Note: The BB3000 enclosure must be earth grounded at the green ground screw. Figure-1 Terminal Description. F-27030-2 Copyright 2008 TAC All Rights Reserved. 3

Legend Line Voltage Wire Low Voltage Wire BB3000 Outside Air Sensor Indirect Water Heater Water Heater Control Priority Circulator Secondary Loop Sensor Priority Circulator Boiler Loop 3 Pop Top TM Zone Valves Secondary Circulator 1 Injection Pump Boiler 2 Primary Loop Sensor 4 Secondary Loop Note: The BB3000 enclosure must be earth grounded at the green ground screw. 1 2 3 4 Must have a heat trap-minimum of 18" in this case. T's should be spaced as close together as possible (no greater than four pipe diameters). Provide a minimum of six pipe diameters upstream of the closely spaced pipe T's in the primary loop. Provide a means to purge the secondary loop. Figure-2 Typical Piping and Wiring Direct Injection Mixing. 4 Copyright 2008 TAC All Rights Reserved. F-27030-2

Legend Line Voltage Wire Low Voltage Wire Indirect Water Heater Water Heater Control BB3000 Outside Air Sensor Priority Circulator Priority Circulator Boiler Loop 1 3 2 Injection Pump Secondary Circulator Pop Top TM Zone Valves Boiler Primary Loop Sensor 5 4 Secondary Loop Note: The BB3000 enclosure must be earth grounded at the green ground screw. 1 2 Must have a heat trap-minimum of 18" in this case. T's should be spaced as close together as possible (no greater than four pipe diameters). 3 4 5 Provide a minimum of six pipe diameters up stream of the closely spaced pipe T's in the primary loop. Provide a means to purge the secondary loop. Use a swing check valve only. Figure-3 Typical Wiring Reverse Injection Mixing. F-27030-2 Copyright 2008 TAC All Rights Reserved. 5

Priority T-stat or Indirect Water Heater Control Line Voltage Wire Low Voltage Wire SR201/301/601 Master R C T1T1 C1 BOILER L1 N/L2 C1 C2 L1 N/L2 C1 C2 L1 N/L2 T2 P2 T1 P1 Injection Pump 2 4 1 3 6 8 5 7 T2 P2 T1 P1 C1 Injection Pump Primary Pump Priority Priority CP X2 ZCL1X1ZR L2 SR201/301/601 Slave R C T1T1 C1 C1 Priority Priority CP X2 ZCL1X1ZR Neutral L2 Hot L1 Terminal Status When Relay Coil Terminals 7 and 8 are Not Energized Relay Terminals Terminals 1 and 5 Terminals 2 and 6 Terminals 3 and 5 Terminals 4 and 6 Normally Closed X X Normally Open X X EXP10 w/skt10 L1 N/L2 EXP10 W/ SKT10 L2 Legend L1 N/L2 Note: The BB3000 enclosure must be earth grounded at the green ground screw. L1 N/L2 BB3000 #1 BB3000 #2 N/L2 Figure-4 Typical Wiring of Two Temperature, Two Secondary Loops with Two BB3000 and Two SR201/301/601 with Priority. (See page 20 for sequence of operation) See page 20 for sequence of operation. 6 Copyright 2008 TAC All Rights Reserved. F-27030-2

2-WIRE THERMOSTAT 72 R W 1 2 3 3-WIRE THERMOSTAT 12:00 RWC 72 T1 T1 1 2 3 4 T2 T2 1 2 3 4 T3 T3 1 2 3 4 T4 T4 1 2 3 4 PRIORITY ZONE ZONE IN ZONE OUT OFF P P+ 1 2 3 4 6 M VL500 #1 (Master) Loop #1 T1 T2 T3 T4 T5 PL Z1 Z2 Z3 Z4 Z5 SYSTEM STATUS ES/CIRC X X T5 T5 1 2 3 4 C1 N L1 N 24VAC Fuse 3.3A/125V Slo-Blo Fuse 120VAC Fuse COM. 10A/125V Slo-Blo Fuse T1 F1 F2 2-WIRE THERMOSTAT 72 MOTOR END SWITCH DHW Controller JUMPER 3 & 4 WHEN USING 2-WIRE ZONE VALVES 2 WIRE ZONE VALVE JUMPER 3 & 4 TACO 3-WIRE ZONE VALVE R W 4-WIRE ZONE VALVE T1 T1 1 2 3 4 T2 T2 1 2 3 4 T3 T3 1 2 3 4 T4 T4 1 2 3 4 PRIORITY ZONE ZONE IN ZONE OUT OFF P P+ 1 2 3 4 6 M VL500 #2 (Slave) Loop #2 T1 T2 T3 T4 T5 PL Z1 Z2 Z3 Z4 Z5 SYSTEM STATUS ES/CIRC X X T5 T5 1 2 3 4 C1 N L1 N 24VAC Fuse 3.3A/125V Slo-Blo Fuse 10A/125V Slo-Blo Fuse 120VAC Fuse COM. T1 F1 F2 MOTOR 24VAC (Com) JUMPER 3 & 4 WHEN USING 2-WIRE ZONE VALVES 2 WIRE ZONE VALVE JUMPER 3 & 4 24VAC (Hot) Switched MOTOR END SWITCH MOTOR 4-WIRE ZONE VALVE Primary Circulator L N BB3000 #1 BB3000 #2 L1 N/L2 L1 L1 N/L2 N/L2 Loop 1 Circulator Injection Pump Loop 2 Circulator Injection Pump TACO 3-WIRE ZONE VALVE 6 8 5 7 T T EXP10 W/ SKT10 BOILER CONTROL 2 4 1 3 Note: The BB3000 enclosure must be earth grounded at the green ground screw. Terminal Status When Relay Coil Terminals 7 and 8 are Not Energized Legend Line Voltage Wire Low Voltage Wire Relay Terminals Terminals 1 and 5 Terminals 2 and 6 Terminals 3 and 5 Terminals 4 and 6 Normally Closed X X Normally Open X X EXP10 w/skt10 Figure-5 Typical Wiring of Two Temperature, Two Secondary Loops with Two BB3000s and Two VL500s with Priority. (See page 20 for sequence of operation) See page 20 for sequence of operation. F-27030-2 Copyright 2008 TAC All Rights Reserved. 7

INSTALLATION Inspection Requirements Precautions Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. These items are required for a typical installation, but are not provided. Job wiring diagram Tools Wiring tools Screwdrivers for mounting and wire terminals Drill and bits for mounting Hardware and accessories as needed Four mounting screws (and anchors or nuts as appropriate) Wire and conduit Outdoor sensor enclosure Two sensor wells Training: Installer must be a qualified, experienced technician. General W A R N I N G Electrical shock hazard! Disconnect power before installation to prevent electrical shock or equipment damage. Make all connections in accordance with the electrical wiring diagram and in accordance with national and local electrical codes. Follow static electricity precautions when installing this equipment. Use copper conductors suitable for operation at 167 F (75 C). The BB3000 enclosure must be grounded. C A U T I O N Avoid locations where excessive moisture, corrosive fumes, explosive vapors, or vibration are present. Avoid electrical noise interference. Do not install near large conductors, electrical machinery, or welding equipment. Federal Communications Commission (FCC) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and may cause harmful interference if not installed and used in accordance with the instructions. Even when instructions are followed, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio and television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/television technician for help. 8 Copyright 2008 TAC All Rights Reserved. F-27030-2

Canadian Department of Communications (DOC) This class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. European Standard EN 55022 C A U T I O N This is a class B (European Classification) product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. System Design Mounting the BB3000 Good system design is essential for proper performance. Figures 2 through 5 offer portions of typical systems, but a full discussion of system requirements is beyond the scope of this document. Refer to modern hydronic heating textbooks and industry training for further information. Sizing the Variable Speed Injection Pump One consideration for good performance is sizing of the injection pump. In most cases, the pump will encounter virtually no head, so a small circulator or the slowest pump speed should be selected. Sample Pump Sizing Calculations T2 = Maximum system supply temperature (radiant): 150 F. F1 = Maximum system supply flow rate (radiant): 14.2 gpm. T1 = Boiler supply temperature: 180 F. Tr = System return temperature (radiant): 130 F. Delta Ts = System temperature drop (radiant) T2 - Tr: 20 F. Fv = Maximum variable flow rate (to be calculated) gpm. Direct Injection Calculations: Fv = F1 x Delta Ts / (T1 - Tr) = 5.7 gpm. Reverse Injection Calculations: Fv = F1 x Delta Ts / (T1 - T2) = 9.5 gpm. The BB3000 is designed for vertical wall or cabinet mounting. Select a mounting location on a solid (non-vibrating) vertical surface near the injection pump or boiler. Do not mount on boiler surface or any other surface that exceeds 100 F (38 C). Do not mount in direct sunlight. 1. Loosen two screws holding the cover and remove the cover. 2. For wall mounting, fasten a screw through one of the top holes in the back plate. Level the unit and fasten the other top screw then the bottom screws. For panel mounting, the enclosure may be used as a template to mark the top of the four keyholes on the mounting surface. 3. Replace the cover (may be left off until wiring is completed). Loop Sensors Install sensors in wells with heat conductive compound for fastest response, or strap the sensor securely to the metal pipe and cover with aluminum tape. Cover with at least one inch of insulation extending two inches beyond each end of the sensor. Primary Loop Sensor For boiler low temperature return protection, the primary loop sensor must be located on the return line of the boiler loop, downstream from any secondary returns to ensure proper mixing and accurate reading. It may alternatively be used as a minimum supply sensor, which is installed on the supply side of the boiler loop. F-27030-2 Copyright 2008 TAC All Rights Reserved. 9

To get an accurate measurement, the primary circulator must be wired to run whenever there is a heat demand. Secondary Loop Sensor The secondary loop sensor should be located downstream of the secondary circulator to ensure proper mixing and an accurate reading. Outdoor Air Sensor Mount the Outdoor Air Sensor in a shaded location (northerly exposure) not affected by the sun or by other heating or cooling sources (air or dryer vents, heat pump, air conditioning equipment, etc.). Mount above the snow line. C A U T I O N To minimize interference, do not position the sensors beyond 75 feet (23 m) from the BB3000. While not normally needed, twisted pair or shielded cable may be used in electrically noisy environments. Sensor Location North Figure-6 Outdoor Air Sensor Placement. Wiring A true earth ground must be wired to the BB3000 enclosure ground screw. Use 18 to 22 AWG for low voltage wiring, and 12 to 14 AWG for line voltage wiring. Use copper wire of a gauge and insulation class sufficient for the current and voltage applied. C A U T I O N Locate wires away from any electric noise generating devices. Do not run sensor wire in close proximity and parallel to line voltage wiring. W A R N I N G All inputs supply Class 2 power to the input device. Do not connect external power source to inputs. W A R N I N G Set the line voltage switch (at the upper left of the circuit board) to the proper voltage before wiring. See Figure-1 or the label inside the enclosure cover for terminal locations on the BB3000 circuit board. See Figures 2 through 5 for sample system wiring. Refer to Specifications to verify that wiring and connected devices meet the required ratings. 10 Copyright 2008 TAC All Rights Reserved. F-27030-2

Sensors (OA1-OA2, PL1-PL2, SL1-SL2) Sensors are non-polarized. Connect the wires from the Outdoor Air Sensor to the OA1-OA2 terminals. Connect the Primary Loop Sensor to PL1-PL2, and the Secondary Loop Sensor to SL1-SL2, running the wires through one of the provided bushings. While not normally needed, twisted pair or shielded cable may be used in electrically noisy environments. Heat Demand Input (T1-T2) Connect an external Class 2 normally open dry contact (that closes with heat demand) to the T1-T2 terminals, running the wires through one of the provided bushings. Priority Demand Input (P1-P2) Connect an external Class 2 normally open dry contact (that closes with domestic hot water demand) to the P1-P2 terminals, running the wires through one of the provided bushings. Boiler Output (X1-X2) Connect the internal Class 2 normally open dry contact from the X1-X2 terminals to the T-T (heat demand) terminals on the boiler, running the wires through one of the provided bushings. Injection Pump (L1-N/L2) This is a phase-controlled triac output that regulates the speed of the pump. Do not connect a pump that exceeds the specified current rating of the BB3000. Connect the injection pump to the injection pump terminals, observing the polarity L1 to L1 and N/L2 to N/L2. Ground the pump per its instructions. Circulator (C1-C2) This output may operate a secondary circulator directly, or it may operate a relay that controls both a primary and a secondary circulator. It is an internal normally open dry contact that may be connected to the line voltage power supply or to a separate line voltage source, and it may be connected in parallel with other dry contacts to operate the circulator. Connect the N/L2 terminal on the circulator (or relay) to the N/L2 source. Connect the L1 terminal on the circulator (or relay) to the C2 terminal on the circuit board. Connect an L1 source to the C1 terminal on the circuit board. Ground the circulator per its instructions. The primary circulator must be wired to run whenever there is a heat demand in order to provide hot water to the secondary loop. Line Voltage Power Supply (L1-N/L2) Set the line voltage switch (at the upper left on the circuit board) to the proper voltage before wiring. Connect the supply to the 115/230 V terminals, observing the polarity L1 to L1 and N/L2 to N/L2. L1 must be a "hot" leg for the proper operation of the control. Ground Connect an earth ground to the green ground screw on the left side of the metal housing. Do not rely on conduit for grounding. C A U T I O N Enclosure must be properly grounded to ensure proper operation of the injection pump, and to prevent shock hazard. INITIAL SETUP Temperature Scale Prior to supplying power to the system, the following board level parameters should be selected or adjusted using the dials and jumpers. Refer to Figure-1 for circuit board layout. Changes to settings must be followed by either cycling power or by pressing the Test/Reset or Display button. The BB3000 control can display operating temperature in Celsius or Fahrenheit. Locate the jumper on the right side of the circuit board. It is factory set on the upper pins for Fahrenheit. To change the display to Celsius, move the jumper to the lower pins. F-27030-2 Copyright 2008 TAC All Rights Reserved. 11

Pump Exercise System Temperature Settings If enabled, the BB3000 pump exercise feature runs the circulator and the injection pump for one minute every three days when not in use. This feature inhibits the buildup of sediment in the pumps and reduces the potential for a locked rotor condition. Locate the jumper on the right side of the circuit board. It is factory set on the upper pins for the pump exercise feature to be on. To disable the feature, move the jumper to the lower pins. The BB3000 has five dials for setting all system temperatures independently. Five design parameters must be set: Outside Air Low - OAL (outdoor design temperature), Outdoor Air High - OAH (warm weather shutdown), Primary Loop Low - PLL (minimum return temperature), Secondary Loop High - SLH (maximum radiant loop temperature), and Secondary Loop Low - SLL (minimum radiant loop temperature). The design temperatures are read from the potentiometers when displayed after power-up, and may be changed while displayed or when followed by a reset. The temperatures may be preset approximately prior to power-up, then adjusted precisely during start-up. Temperature Setting Guidelines OAL - Outside Air Low Set the outside design temperature according to the standard design temperature for the geographic area, or the outside temperature at which maximum heat is desired. OAH - Outdoor Air High The Warm Weather Shutdown (WWSD) temperature should be set to the outdoor temperature at which no heat is desired, typically 65 to 70 F. To establish a reset curve OAH must be at least 20 F (11 C) degrees higher than OAL. PLL- Primary Loop Low The minimum boiler return temperature should be set according to boiler specifications. PLL must be set lower than the turn-on point (high limit minus differential) of the boiler. If PLL is set higher than the boiler turn-on point, the boiler may not fire while the BB3000 is waiting for the primary loop temperature to rise above PLL. For cold start boilers, or to disable boiler condensation protection, set PLL to Cold Start. If the primary loop sensor is positioned on the primary supply, set PLL for the minimum supply temperature desired. It must be set lower than the turn-on point of the boiler to prevent a lockout condition. The PLL uses a 10F degree differential. For example: With PLL set to 130 F the boiler output will turn on when the primary loop return drops to 130 F during a heat demand and will remain on until the temperature reaches 140 F (as long as there is a heat demand). SLH - Secondary Loop High Set the maximum radiant loop temperature to the water temperature desired when it is coldest outside (at design temperature). Do not exceed the recommended temperature for the flooring being used. SLL - Secondary Loop Low Set the minimum radiant loop temperature desired when the outdoor temperature is near the WWSD point. A typical setting is 90 F. To establish a reset curve SLL must be at least 20F (11C) degrees lower than SLH. STARTUP Status Indicators Before power-up, note the location and purpose of each of the following indicators Heat Demand LED: Lit when there is a contact closure at the "Heat Demand" input (when any of the heating zones are calling for heat). Circ. LED: Lit when the circulator output is turned on by the BB3000. Boiler LED: Lit when the boiler output is turned on by the BB3000. WWSD/Priority LED: Flashes slowly when there is a contact closure at the Priority input (when there is a call for priority heat). Lit continuously when the BB3000 is in warm weather shutdown mode (unless there is a priority call). Three-Character LED Display: Run Mode (Normal operation), Displays the three sensors (Outdoor Air, Primary Loop, and Secondary Loop), the Secondary Loop Setpoint and the injection pump output sequentially. Test and Setup Modes, Sequentially displays all system settings, inputs and outputs. 12 Copyright 2008 TAC All Rights Reserved. F-27030-2

Test Mode Turn on the power to the system. Left untouched, the display will begin scrolling through all the parameters set previously. The control will then continue in the Run Mode. Hold down the Display button and press the Test/Reset button to enter test mode. The Display button can then be used to advance through the test sequence in Table-1. Verify the display shows the proper values and the inputs and outputs function properly.the display must be advanced manually in this mode to allow for system testing. The test sequence can be repeated at any time by holding down the Display button and pressing the Test/Reset button. Table-1 Test Mode Display Sequence. Feature Displayed Description Display Test 8.8.8. Verify that all segments are lit 24 VAC Supply Voltage Test AC 15.0...30.0 Verify that transformer voltage is 20-30 Vac Heat Demand (thermostat) Input Test The thermostat or end switch may be cycled to verify proper operation tt OFF ON Open contact: Heat Demand LED off Closed contact: Heat Demand LED on Circulator Output Test crc ON Relay, circulator, and Circ. LED on Boiler Output Test blr ON Relay, boiler, and Boiler LED on Priority Input & Priority/WWSD LED test The priority switch/contact may be cycled to verify proper operation. OAC (Outdoor Air Cutoff) OFF ON Open contact: Priority/WWSD LED off Closed contact: Priority/WWSD LED flashes Injection Pump Control IP 100...0 Phase control output ramps from 100 to 0% repeatedly Continue in set up mode t See Power-up/Set-up Display Sequence Setup Mode This mode is entered on power up or any time the Display or Reset button is pressed. On power up or reset the settings are scrolled through automatically. To scroll through them manually press the Display button once and then press it again after each setting has been reviewed. After the test mode, the display will continue as it did at power up except it is advanced manually by pressing the Display button. Verify each of the settings shown in Table-2. The jumper settings can be changed and the temperatures can be fine tuned to the desired settings while they are displayed. Subsequent changes will not be implemented until the power is reset or one of the buttons is pressed to repeat the sequence. The three sensor readings can also be verified. While in the Setup Mode, the display will remain at the current parameter long enough to adjust the setting or view the sensor reading. If the Display button is not pressed for 60 seconds, the display will start advancing automatically. To stop the display again, press the Display button. To Start at the beginning of the Setup Mode, press the Reset button then the Display button to stop it from advancing. F-27030-2 Copyright 2008 TAC All Rights Reserved. 13

Table-2 Power-Up/Setup Display Sequence. Feature Displayed Description Temperature Scale (jumper-selectable) t F C Fahrenheit Celsius Pump Exercise Option PE On Off Pump Exercise Enabled Pump Exercise Disabled Outdoor Air Low (Outdoor Design Temperature) (potentiometer adjustable) OAL -60..41-51..5 F range C range Outdoor Air High (Warm Weather Shutdown) (potentiometer adjustable) OAH 40..70 4..21 F range (must be OAL+20) C range (must be OAL+11) Primary Loop Low (Min. Return Temperature) (potentiometer adjustable) PLL 0, 60..150 0, 15..65 F range (0=Cold Start) C range (0=Cold Start) Secondary Loop High (Max. Radiant Loop Temp.) (potentiometer adjustable) SLH 90..200 32..93 F range C range Secondary Loop Low (Min. Radiant Loop Temp.) (potentiometer adjustable) SLL 70..110 21..43 F range (must be SLH-20) C range (must be SLH-11) Outdoor Air Temperature (Current Outdoor Temp.) (sensor input) OA -60..122-51..50 Err...Opn Err...Sht F range C range Opened sensor error Shorted sensor error Primary Loop Temperature (Current Return Temp.) (sensor input) PL 32..221 0..105 Err...Opn Err...Sht F range C range Opened sensor error Shorted sensor error Secondary Loop Temperature (Current Radiant Temp.) (sensor input) SL 32..221 0..105 Err...Opn Err...Sht F range C range Opened sensor error Shorted sensor error Continue in Run Mode run... (If scrolling manually, press the Display button to continue.) Brief delay between modes Run Mode After the Setup Mode is complete, the display will indicate run. Pressing the Display button once more will advance the control into the run mode. It will continuously loop until the Test/Reset or Display button is pressed. Verify that the five values are displayed repeatedly as shown in Table-3 without indicating a low power condition ( LO...AC ) or sensor fault (flashing display and Err displayed instead of temperature). Once in the Run Mode, changes in settings are ignored until a button is pressed or power is lost and restored. Pressing the Display button does not interrupt normal operation, whereas pressing Test/Reset resets the control to a power-up condition. The Outdoor Air (OA), Primary Loop (PL), Secondary Loop (SL) and Secondary Loop Setpoint (SLS) temperatures are monitored continuously and displayed during normal operation. The SLS is calculated based on the design settings and the current OA temperature. The injection pump control signal is also displayed after the temperatures. With the system operating, it may be further tested by operating the thermostats or heat demand relays. Sensors may be disconnected to accommodate abnormal startup conditions. If the outdoor temperature is above the OAH setting, the system will indicate a Warm Weather Shutdown condition and prevent heating operation. To temporarily override this and allow further system testing, disconnect one lead of the OA sensor. This results in a default temperature at the midpoint between 32 F (0 C) and OAL. 14 Copyright 2008 TAC All Rights Reserved. F-27030-2

If the primary loop return temperature is below the PLL setting the system will indicate a low return temperature (flashing L after PL ) which may prevent further heating of the secondary loop until the primary loop system reaches operating temperature. To temporarily override this and allow further system testing, disconnect one lead of the PL sensor. This results in a default PL temperature of 151 F (66 C). Table-3 Run Mode Sequence. Feature Displayed Description Outdoor Air Temperature (Current Outdoor Temp.) (Sensor Input) OA -60..122-51..50 Err (continuously flashing) F range C range Sensor error Primary Loop Temperature (Current Return Temp.) (Sensor Input) (Flashing L appears after PL indicating low return) PL 32..221 0..105 Err (continuously flashing) F range C range Sensor error Secondary Loop Setpoint (Calculated Radiant Setpoint) SLS 70..200 21..93 F range (SLL SLS SLH) C range (SLL SLS SLH) Secondary Loop Temperature (Current Radiant Temp.) SL 32..221 0..105 Err (continuously flashing) F range C range Sensor error Injection Pump IP 0..100 Injection pump output (%) Low AC condition (24 Vac supply <20.0 Vac) LO...AC...15.0..19.9 (blank if below 15.0 Vac) Injection pump, circulator, and boiler off. F-27030-2 Copyright 2008 TAC All Rights Reserved. 15

THEORY OF OPERATION Injection Pump Control Heat Demand Priority Demand Circulator Operation Boiler Operation Primary Loop Return Protection Three sensors provide feedback for the control system. The colder it is outside the warmer the desired water temperature or SLS. At design temperature (OA = OAL), SLS = SLH. At warm weather shutdown (OA = OAH), SLS = SLL. Between OAL and OAH, SLS is determined by a straight line relation. See Figure-7 and Figure-8. The injection pump is enabled whenever there is a heat demand. To provide the proper temperature in the radiant loop, the injection pump speed is controlled using a proportional-integral-derivative (PID) algorithm. When the injection pump is started, it is given full power for one second to ensure that it starts running, and then its speed is reduced to meet heat demand. When a heating zone is calling for heat, the "Heat Demand" LED indicates a contact closure provided to the "Heat Demand" input. The contact must be maintained closed or open for five seconds before the control changes its state. Zone Controls For On/Off zones, use electronic thermostats with small differentials (1F degree) to provide close control. The frequent cycling of anticipating-type thermostats may prevent the system from stabilizing. If the system has only a few zones which are on for short periods of time, the secondary loop temperature may not stabilize. If stability is not achieved, the Heat Demand inputs can be shorted (using a switch or relay contact) to keep the secondary circulator running and provide consistent secondary loop temperature. When the priority zone is calling for heat, the Priority/WWSD LED flashes on and off once per second (regardless of WWSD status). The injection pump is turned off, and the boiler output is turned on. The circulator contacts are closed and the circulator LED is turned on whenever there is a heat demand, except during warm weather shutdown. Priority demand does not affect circulator operation. The boiler contacts are closed and the boiler LED is turned on when there is a priority demand or when the injection pump output reaches 50%. When the SL temperature is high enough to allow the pump speed to drop to 30% the boiler output is turned off. To prevent short-cycling the boiler output will not turn off until it has been on for at least five minutes and will not restart until it has been off for at least one minute. If the PL sensor indicates a possibility of the return temperature falling below the selected minimum, the injection pump speed is reduced to prevent condensation of flue gases, and the boiler is turned on to raise the primary loop temperature. Once the boiler is turned on due to a low return temperature, it will remain on until the temperature is at least 10 F above the minimum (PLL). If the return temperature actually falls below PLL, the injection pump is turned off while the boiler recovers. This function is active only while there is a heat demand. Setting PLL to "Cold Start" disables the function. To get an accurate PL measurement needed for boiler protection, the primary circulator must be wired to run whenever there is a heat demand. Pump Exercising The pump exercise feature, if enabled, will run the circulator and the injection pump sequentially for one minute each, every three days when not in use. 16 Copyright 2008 TAC All Rights Reserved. F-27030-2

Warm Weather Shutdown Sensor Failure Fine Tuning When the OA temperature reaches the warm weather shutdown level the control will turn off the injection pump, radiant loop circulator and boiler, and turn on the Priority/WWSD LED. In the event of a sensor failure, the control will continue to operate in a safe mode to prevent freeze up. The system will not shut down. The display will flash rapidly to alert the building owner and Err will be displayed instead of the temperature, but operation will continue as detailed. The fault handling techniques allow replacement of the sensors while the control continues to run. OA If the OA sensor fails, the OA temperature will default to the midpoint between 32 F and OAL ("Err" displayed after "OA"). This will keep the SLS at the reset temperature corresponding to 32 F-(32 F-OAL)/2. The sensor fault may result in insufficient heating at lower temperatures but the default condition should help prevent freeze up. This default allows for a warm weather test mode by temporarily disconnecting the OA sensor (no need for a fixed resistor to be installed). It also allows for a normally open switch or time delay relay contact to be placed in parallel with the sensor. This could be used as a temperature boost for seasonal start up or override of the WWSD. PL If the primary loop return sensor fails, the PL temperature will default to 151 F ("Err" displayed after "PL"). This is above any possible setting for the return protection (PLL), so it effectively allows continued operation without the benefit of return protection. If PLL is set to "Cold Start" a sensor fault will cause "Off" to be displayed after "PL" while running. This allows the control to be installed without the sensor if it is not needed for the application. SL If the SL sensor fails, the injection pump will provide a minimum delivery of heat to the secondary loop during a heat demand. The injection pump will run at minimum speed for 10 seconds every minute (and "Err" is displayed after "SL"). The sensor fault may result in insufficient heating but the default condition should help prevent freeze up. Changes to the temperature settings are read only when displayed, either after pressing a button or after power-up. 1. If heating is inadequate at relatively warmer outdoor temperatures (below OAH) increase the minimum loop temperature (SLL) by 5 to 10F degrees. See Figure-7. 2. If heat output is excessive at relatively warm outdoor temperatures (below OAH) decrease the minimum loop temperature (SLL) 5 to 10F degrees. See Figure-7. 3. If heating is inadequate at relatively cold outdoor temperature (above OAL) raise OAL by 5 to 10F degrees. See Figure-8. If the outdoor temperature is below OAL the SL temperature should be at its maximum. W A R N I N G Do not increase SLH above the maximum temperature limitations for the installation method. 4. If the heat output is excessive at moderately cold outdoor temperatures (above OAL), decrease the outdoor design temperature (OAL) by 10 to 20F degrees. See Figure-8. If the outdoor temperature is at or below OAL, SLH may be decreased by 10 to 20F degrees. F-27030-2 Copyright 2008 TAC All Rights Reserved. 17

Radiant Heating Reset Curves Loop Temp. Setpoint (F) SLL Minimum Loop Temp. (70 to 110F) 200 SLH 190 Maximum Loop Temp. 180 (90 to 200F) 170 160 150 140 130 120 110 100 90 80 70 Injection Pump Off -60-50 -40-30 -20-10 0 10 20 30 40 50 60 70 OAL OAH Outdoor Outdoor Temp. (F) Warm Weather Design Temp. (-60 to 41F) Shutdown Temp. (40 to 70F) Figure-7 Adjustment of SLL for Proper Floor Temperature When Warmer Outside. Loop Temp. Setpoint (F) SLL Minimum Loop Temp. (70 to 110F) 200 SLH 190 Maximum Loop Temp. 180 (90 to 200F) 170 160 150 140 130 120 110 100 90 80 70 Injection Pump Off -60-50 -40-30 -20-10 0 10 20 30 40 50 60 70 OAL OAH Outdoor Outdoor Temp. (F) Warm Weather Design Temp. (-60 to 41F) Shutdown Temp. (40 to 70F) Figure-8 Adjustment of OAL for Proper Floor Temperature When Colder Outside. 18 Copyright 2008 TAC All Rights Reserved. F-27030-2

APPLICATION EXAMPLES Figures 4 and 5 show wiring of two typical systems. The operation of these systems is discussed in detail below. EXP10/SKT10 Relay: When coil terminals 7 and 8 are not energized; terminals 2-6 and 1-5 are closed; terminals 4-6 and 3-5 are open. BB3000 with SR601 BB3000 with VL500 In this system, two BB3000s, two SR601s and an EXP10 relay are used to control injection pumps, zone pumps, a primary loop pump, and a boiler (see Figure-4). There are two separate secondary radiant floor loops, each controlled by a BB3000. Each secondary loop provides supply water to the associated zone pumps that are controlled by the SR601s. The water temperature for each secondary zone loop is controlled and reset by the BB3000, depending on the outdoor air temperature and the heating demands of the floor loops. On A Call For Heat By Any or All Non-Priority Zones 1. A thermostat connected to zone 1 (for example) of slave SR601 calls for heat by closing its normally open contacts across terminals T1/T1 of the SR601. 2. Zone 1 pump is energized with 120 V across C1/C1 of the slave SR601. 3. Slave SR601 s normally open dry contacts, X1 and X2/ZR, close, which completes a circuit across the heat demand terminals T1/T2 of the BB3000 #2. 4. BB3000 #2 operates the injection pump, primary pump, and the boiler per specifications. To supply hot water to the secondary loop and to ensure a valid primary temperature measurement, the primary loop circulator must be powered whenever there is a heat demand on the secondary loop. Figure-4 shows one method of accomplishing that. On A Call For Heat By The DHW Priority Zone 1. On a call for domestic hot water the normally open dry contacts in the DHW controller close, completing a 24 V circuit which energizes the EXP10 relay coil at terminals 7 and 8. The 24 V power is provided via the R and C terminals on the master SR601. The R and C terminals are wired in parallel to the 24 V transformer on the SR601. 2. The EXP10 coil is energized, closing the normally open contacts and opening the normally closed contacts. a. EXP10 N.O. contacts 3 and 5 close across the master SR601s T1/T1 terminals, generating a DHW Priority heat demand. The DHW pump is energized with 120V on C1/C1 terminals of the master SR601. DHW Priority logic locks out power to all other SR601 master and slave circulators. b. EXP10 N.O. contacts 4 and 6 close, completing the circuit to the DHW Priority input terminals P1/P2 on BB3000 #1 and BB3000 #2. 3. Both BB3000 #1 and BB3000 #2 close their N.O. contacts, X1/X2 and C1/C2, which generates a heat demand to the boiler s T/T controller terminals and turns on the primary pump. 4. The DHW Priority Logic in each BB3000 locks out power to the injection pumps. In this system, two BB3000s, two VL500s and an EXP10 relay are used to control injection pumps, zone valves, primary and secondary loop pumps, and a boiler (see Figure-5). There are two separate secondary radiant floor loops, each controlled by a BB3000. Each secondary loop provides supply water to the associated zone valves that are controlled by the VL500s. The water temperature for each secondary zone loop is controlled and reset by the BB3000, depending on the outdoor air temperature and the heating demands of the floor loops. F-27030-2 Copyright 2008 TAC All Rights Reserved. 19

On A Call For Heat By Any Non-Priority Zone 1. Thermostat contacts close the circuit to T1/T1 on VL500 #2. 2. Terminals 1 and 2 of zone 1 are energized on VL500 #2 which powers the zone valve open. 3. End switch N.O. contacts 3 and 4 are closed on the zone 1 valve on VL500 #2. 4. C1 and N are energized on VL500 #2. 5. Primary circulator is started. 6. Normally open contacts are closed at terminals X/X on VL500 #2. 7. Circuit is completed to terminals T1/T2 on the BB3000 #2. 8. BB3000 #2 operates secondary circulator, injection pump and boiler per specifications. On A Call For Heat From A Priority Zone 1. DHW controller contacts close the circuit to T1/T1 on VL500 #1. 2. Terminals 1 and 2 of zone 1 are energized on VL500 #1, which powers the zone #1 valve open. 3. End switch N.O. contacts 3 and 4 are closed on the zone 1 valve on VL500 #1. 4. C1 and N are energized on VL500 #1. 5. Primary circulator is started. 6. Zone valves 2-5 on VL500 #1 are de-energized. 7. Circuit is opened at Zone Out 3 and 4 on VL500 #1. 8. Zone In 1 and 2 circuit is opened on VL500 #2. 9. All zones on VL500 #2 are de-energized. 10. Zone Out 3 and 4 circuit is opened on VL500 #2. 11. Circuit at terminals 7 and 8 is opened on EXP10 relay. 12. Circuit to P1 and P2 is closed at BB3000 #1 & #2. 13. BB3000 #1 and #2 turn off injection pumps and operate boiler per specifications. MAINTENANCE FIELD REPAIR Fuse Replacement The BB3000 requires no maintenance. Regular maintenance of the total system is recomended to assure sustained, optimum performance. Replace any damaged or failed units with new replacements. Fuses are the only replaceable components. 1. Turn off power to the BB3000. 2. Remove the BB3000 cover. 3. Remove a fuse. 4. Check continuity across the fuse. 5. If the fuse is faulty replace it with one of the same type and rating (see specifications). 6. Re-install the BB3000 cover. 7. Turn on the power to the BB3000. 20 Copyright 2008 TAC All Rights Reserved. F-27030-2

DIMENSIONAL DATA 8-1/4 (210) 3/16 (5) 4-7/8 (124) 6- (1 2 ( TROUBLESHOOTING Symptom Possible Cause Action No display Unit displays "LO AC" or no display. Unit flashes and displays "Err" after "OA", "PL", or "SL". Primary or Secondary Loop temperature too low. No 120 Vac power. Blown internal fuse F1. Voltage selector switch in the 230V position with a 120V supply. Brownout condition. Offending sensor or wiring is either open or shorted. Primary Loop temperature set to "Cold Start" Primary circulator not wired to run with heat demand. Check circuit breaker or fuse. Reset or replace as necessary. If it continues to fault, call a qualified technician. Check fuse F1; replace if necessary. Move voltage selector switch to the proper position. Measure supply voltage to verify. Check offending sensor for damage to wire or sensor. The Setup mode can be used to determine whether the sensor wiring is shorted or open. Set Primary Loop temperature as described under "Initial Setup." Correct wiring. No power to circulator. Blown internal fuse F2. Line voltage (L1) not connected to circulator relay (C1). Check fuse F2 and replace if necessary. Connect L1 to C1 according to the wiring instructions. Injection pump not working properly. Ground wire not attached. Line and neutral reversed. Attach a ground wire to the green terminal screw according to the instructions. Verify the wiring to L1 terminal is the hot lead. F-27030-2 Copyright 2008 TAC All Rights Reserved. 21

22 Copyright 2008 TAC All Rights Reserved. F-27030-2

F-27030-2 Copyright 2008 TAC All Rights Reserved. 23

Copyright 2008, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, IL 61132-2940 www.tac.com F-27030-2