FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

Similar documents
FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS st Ave, #605, Seattle, WA June 2 nd, 2017

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS Interlake Ave N, Seattle, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS W Crockett St., Seattle, WA September 5 th, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS Wells Ct S, Renton, WA 98055

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS Chestnut Street, Everett, WA 98201

FAIRA TRANSPARENCY REPORTS th Pl W, Lynnwood, WA 98087

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS th Ln NE, Issaquah, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS. 706 N 103rd St, Seattle, WA August 14, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS th Ave N, Seattle, WA 98109

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

FAIRA TRANSPARENCY REPORTS th Pl SE, Covington, WA May 17 th, 2017

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

RW West Consultants. Property Inspection Report

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Kirkland, WA February 16, 2018

FAIRA TRANSPARENCY REPORTS Burke Ave N, Seattle, WA March 14, 2018

FAIRA TRANSPARENCY REPORTS th Ave NE, Seattle, WA August 23 rd, 2017

FAIRA TRANSPARENCY REPORTS. 609 Union Avenue NE, Renton, WA 98059

FAIRA TRANSPARENCY REPORTS S 298th St, Auburn, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Arlington, WA 98223

FAIRA TRANSPARENCY REPORTS th Ave S, Des Moines, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS th Ave NW, Seattle, WA 98107

FAIRA TRANSPARENCY REPORTS SE 225th St, Maple Valley, WA June 2nd, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, SeaTac, WA August 4, 2017

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS rd Ave SW, Vashon, WA May 19 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

FAIRA TRANSPARENCY REPORTS. July 6, 2016

RW West Consultants, Inc. Property Inspection Report Inspector: Clifton Moody (Skip), RW West Consultants, Inc. Cover Page

FAIRA TRANSPARENCY REPORTS st Ave SE, Renton, WA 98058

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS NE 116th Pl, Kirkland, WA April 20 th, 2017

FAIRA TRANSPARENCY REPORTS Silver Springs Dr NW, Gig Harbor, WA February 20, 2018

Troy's Home Inspection Services LLC

FAIRA TRANSPARENCY REPORTS. 808 NW 125th St, Seattle, WA February 12, 2018

Hearth and Homes Inspections, llc

Inspector Gadget Homes

FAIRA TRANSPARENCY REPORTS. 76 Cedar ST, Unit 505, Seattle, WA May 27, 2016

FAIRA TRANSPARENCY REPORTS th Ave S, Seattle, WA November 9, 2017

FAIRA TRANSPARENCY REPORTS. January 6 th, 2017

Jeff Brown Inspections

Patriot Home Inspections

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Axiom Property Inspections

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

FAIRA TRANSPARENCY REPORTS

Transcription:

608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 6700 NE 182nd St, C101, Kenmore, WA 98028 We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/12606 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We re happy you ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

RW West Consultants Inc Property Inspection Report Inspector: David A Young, RW West Consultants Inc Cover Page

6700 NE 182nd St,, C101, Kenmore, WA Inspection prepared for: Faira.com Real Estate Agent: - Date of Inspection: 8/9/2018 Time: 11:00 AM Age of Home: 0 Size: 988 Order ID: 4151 Inspector: David A Young License #2245 13280 linden ave N, Apt #503, seattle, WA 98133 Phone: 2067872662 Email: david@rwwestconsultants.com rwwestinspections.com

INTRODUCTION: Inspection Details We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific non-code, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. This is an inspection of this unit only. Exterior conditions and common areas are generally the responsibility of the condominium association. Recommend review your resale certificate or public offering statement Items denote serious, safety or items that require further investigation Items denote minor or maintenance items Items denote locations and shutoff valves Page 2 of 25

1. Conditions Entryway Ceiling and walls are in good condition overall. Light fixture operates. Entry door operates and locks overall. Linoleum flooring is in good condition. Page 3 of 25

1. Location Location Southeast Living Room 2. Living Room Walls and ceilings appear in good condition overall. Flooring is carpet. Heat register present. Accessible outlets operate. Light fixture operates. 3. Floor Observations: Carpet Wrinkled, recommend restretching. 4. Fireplace Fireplace was wood burning type. Damper is in place. Observations: Creosote buildup in the fireplace, recommend cleaning by licensed chimney sweep before using. Page 4 of 25

5. Heating Electric Convector heater operates. Page 5 of 25

1. Location Location Southwest Dining Room 2. Dining Room Walls and ceilings appear in good condition overall. Flooring is carpet. Heat register present. Accessible outlets operate. Light fixture operates. Observations: Cracking at the ceiling and or walls does not appear unusual. 3. Heating Electric Convector heater operates. 1 Cracking at the ceiling and or walls does not appear unusual. Page 6 of 25

1. Kitchen Room Kitchen Walls and ceilings appear in good condition overall. Flooring is linoleum. Accessible outlets operate. Light fixture operates. Sink and faucets are in operable condition overall. Cabinet doors and drawers are in operable condition overall. Cabinet doors and drawers are in operable condition overall. 2. Counter Condition Formica counter is in good condition overall. 3. Cabinet Cabinet doors and drawers are in operable condition overall. 4. Disposal Disposal operates overall. 5. Dishwasher Dishwasher was in operable condition. 6. Microwave Observations: Built-in microwave ovens are tested using normal operating controls. Unit was tested and appeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scope of this inspection. If concerned, client should seek further review by qualified technician prior to closing. 7. Stove/Oven Stove/oven were in operable condition overall. Page 7 of 25

8. Refrigerator Refrigerator was in operable condition. 9. Sinks Sink was in operable condition overall. 10. Electrical Outlets are GFCI protected at the counters. Observations: Loose outlets present, recommend securing. Outlet and or Switch cover plates missing, recommend correction as a safety precaution. Page 8 of 25

11. Vent Condition Vent fan is part of microwave and is Recirculating Type 12. Heating Dining room electric convector heater serves as heat source for this area. Page 9 of 25

1. Location Materials: 1st Floor 1st Floor Bathroom 2. Room Ceiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. There were no visible indications of plumbing deficiencies overall. Observations: Damage to wall underneath sink, recommend repair. 3. Counters Formica counter tops are in good condition overall. Damage to wall underneath sink, recommend repair. 4. Cabinets Cabinet doors are in operable condition overall. 5. Sinks Sink was in operable condition overall. 6. Exhaust Fans Vent fan operates overall. 7. Floors Linoleum Flooring is in good condition overall. 8. Tub Tub and shower were in good condition overall. 9. Toilet Toilet was in operable condition overall. 10. Heating Heat lamp operates. Page 10 of 25

11. Electrical GFI outlets within 6 feet of water sources. Page 11 of 25

1. Location Kitchen closet Laundry 2. Condition Ceiling and walls are in good condition overall. Accessible outlets operate. There were no visible indications of plumbing deficiencies overall. 3. Electrical Observations: GFCI outlets have been required for Laundry and utility sinks (since 2005)No GFCI protection present,, strongly recommend GFCI outlets are installed as a safety precaution. 4. Exhaust Fans Vent fan operates overall. 5. Dryer Dryer appeared to exhaust to the exterior. Dryer is electric Unit 220 volt electrical service for electric dryer. Dryer vent Page 12 of 25

6. Floor Condition Linoleum Flooring is in good condition overall. 7. Washer Materials: Washer appeared to be in operable condition. Washer faucets were in operable condition, no visible leakage. Page 13 of 25

1. Location Location East Bedroom 1 2. Bedroom Room Walls and ceilings appear in good condition overall. Flooring is carpet. Heat register present. Accessible outlets operate. Light fixture operates. 3. Floor Observations: Carpet staining. 4. Heating Electric baseboard heater operates. Page 14 of 25

Page 15 of 25

1. Location Location Northeast Bedroom 2 2. Bedroom Room Walls and ceilings appear in good condition overall. Flooring is carpet. Heat register present. Accessible outlets operate. Light fixture operates. 3. Floor Observations: Carpet Wrinkled, recommend restretching. 4. Heating Electric baseboard heater operates. Page 16 of 25

Page 17 of 25

1. Plumbing Plumbing/Water Heater1 Water lines were copper Drain and waste lines were plastic. 2. Water Heater Condition Heater Type: Electric water heater. 50 gallons Location: The heater is located in the laundry room. 3. Age Approximately 11 years of age, average life span is 10 to 12 years. Observations: Water heater is near end of useful life span, recommend monitoring. 4. Condition Seismic straps are in place. Expansion tank is in place. Water heater has drip pan in place. Observations: Drip pan does not have outlet drain to exterior, recommend outlet drain be installed or leak alarm sensor 5. TPRV Condition Temperature Pressure Relief Valve (TPR Valve) present. Page 18 of 25

1. Location Materials: Located in the Bedroom 2 Electrical 1 2. Electrical 125 AMP service, 1/0 Aluminum service entrance wires. Observations: Sharp-pointed metal screws hold panel cover in place. These are a potential hazard as they may puncture wire insulation and electrify panel box, becoming a shock or electrocution hazard. These screws should be replaced with approved, flat-tipped screws. Strongly recommend conditions are corrected. Sharp-pointed metal screws hold panel cover in place. These are a potential hazard as they may puncture wire insulation and electrify panel box, becoming a shock or electrocution hazard. These screws should be replaced with approved, flattipped screws. Strongly recommend conditions are corrected. 3. Grounding Electrical service is grounded and bonded. Page 19 of 25

4. Wiring Type Breaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiring is copper. Observations: White neutral wires connected to circuit breakers should be black or red taped to designate they are hot, recommend further investigation and correction by licensed electrical contractor. White neutral wires connected to circuit breakers should be black or red taped to designate they are hot, recommend further investigation and correction by licensed electrical contractor. Page 20 of 25

1. Shutoff Locations Shutoffs Main water shutoff located below 1st floor bathroom sink 2 Water heater water line shutoff is located above the water heater. Page 21 of 25

1. Appliances/Equipment Equipment 2 Washer 2 Dryer 2 Water Heater 2 Refrigerator Page 22 of 25

2 Microwave 2 Oven 2 Dishwasher 2 Disposal Page 23 of 25

Glossary Glossary Term Expansion Tank GFCI TPR Valve Definition An expansion tank or expansion vessel is a small tank used to protect closed (not open to atmospheric pressure) water heating systems and domestic hot water systems from excessive pressure. The tank is partially filled with air, whose compressibility cushions shock caused by water hammer and absorbs excess water pressure caused by thermal expansion. A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. The thermostat in a water heater shuts off the heating source when the set temperature is reached. If the thermostat fails, the water heater could have a continuous rise in temperature and pressure (from expansion of the water). The temperature and pressure could continue to rise until the pressure exceeds the pressure capacity of the tank (300 psi). If this should happen, the super-heated water would boil and expand with explosive force, and the tank would burst. The super-heated water turns to steam and turns the water heater into an unguided missile. To prevent these catastrophic failures, water heaters are required to be protected for both excess temperature and pressure. Usually, the means of protection is a combination temperature- and pressurerelief valve (variously abbreviated as T&P, TPV, TPR, etc.). Most of these devices are set to operate at a water temperature above 200 F and/or a pressure above 150 psi. Do not attempt to test the TPR valve yourself! Most water heating systems should be serviced once a year as a part of an annual preventive maintenance inspection by a professional heating and cooling contractor. From Plumbing: Water Heater TPR Valves Page 24 of 25

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expense to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all pages of the report as the summary alone does not explain all of the issues. All repairs should be done by a licensed & bonded tradesman or qualified professional. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Living Room Page 4 Item: 4 Fireplace Creosote buildup in the fireplace, recommend cleaning by licensed chimney sweep before using. Kitchen Page 8 Item: 10 Electrical Outlet and or Switch cover plates missing, recommend correction as a safety precaution. Laundry Page 12 Item: 3 Electrical GFCI outlets have been required for Laundry and utility sinks (since 2005)No GFCI protection present,, strongly recommend GFCI outlets are installed as a safety precaution. Page 25 of 25