Eclipse ER Indirect Air Heater

Similar documents
Eclipse ER Indirect Air Heater

STARJET BURNER SJ075 SJ980

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Eclipse AirHeat Burner

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

940ES Tankless Water Heater

940ES Tankless Water Heater

Residential Gas Tankless Water Heater

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

C1210ES Tankless Water Heater

C1050ES Tankless Water Heater

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

RG7D 1-Stage Heat Series

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Clean Heat. Clean Air. PRODUCTGUIDE

Residential/Commercial Gas Condensing Tankless Models

Eclipse RatioMatic Burners

V-Line. Nozzle-mix line burner

GB Condensing Gas Boiler

Eclipse AirHeat Burners

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

G315/6 Cast Iron Boiler

Design Guide No. 330, 10/02 Immersion Burners

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

MD-170 Installation/Operator's Manual

DELTA-TE III. Nozzle-mix line burner

G315/5 Cast Iron Boiler

G515/7 Cast Iron Boiler

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

"HC" AIRFLO. In-duct firing line burner

G615/11 Cast Iron Boiler

PROFIRE -E SERIES BURNERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

APX. Nozzle-mix line burner

Tankless Condensing High Efficiency Water Heaters

Product Data BW9 WATER BOILER SERIES B

SB615/310 Stainless Steel Condensing Boiler

GB Condensing Gas Boiler

Date: Project #: Engineer: Prepared By: Bid Date:

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

G6RC Series TECHNICAL SPECIFICATIONS

GB Condensing Gas Boiler

Presentation Outline. Commercial 1 Track. Unit #4: Commercial Water Heating

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Suggested Specifications Prestige Excellence 110

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Eclipse ImmersoJet Burner

Commercial Gas Water Heaters

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Eclipse 90 UV Scanner Model A Version 1

INDITHERM. Low temperature gas burners

TECHNICAL SPECIFICATIONS

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

MECHANICAL VENTING VERSATILITY

Commercial Gas Water Heaters

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

FG7T (C and L Series)

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

TCD-TCH. Self-contained rooftop unit. VOYAGER I and II range TCD: Downflow discharge and intake TCH: Horizontal discharge and intake

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

CONDENSING HIGH EFFICIENCY BOILERS

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

Advanced Heating and Hot Water Systems

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

CLIMATE CONTROL PRODUCT GUIDE

Eclipse Self-Check UV Scanner

HCLEARFIRE. High-efficiency, modular steam boiler HP

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

MEGASTAR TM BURNER MS-25 MS-150

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

Indiana WX Oil Furnace Inspection Guide

TECHNICAL SPECIFICATIONS

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Residential & Commercial

U n i t H e at e r s

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

10 : 1 Turndown Ratio

LAARS PENNANT. Economical efficiency for greater savings

Ruud Achiever Series Multi position Gas Furnaces

XLT Oven & AVI Hood. Technical/Rough-In Specifications for Gas & Electric Ovens & Hoods

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Transcription:

Data 11 1/8/1 Eclipse ER Indirect Air Heater Version 1 Standard Efficiency (1/" Spacing Heat Exchanger) Parameter Air Delivery Temp., F ( C) 1 scfm referenced to 7 F at 1 atmosphere (1.9 psia), Nm /hr referenced to C at 1 atmosphere (.989 bar). Assuming - VAC / Phase / Hz electrical power. Please contact Eclipse for other electrical power options. unit uses two HP (18. kw) motors. All weights are approximate. ER Heater Size (1 through 8) and Burner Size (Small or Large) 1 7 8 Small Large Small Large Small Large Small Large Small Large Small Large Small Large Small Large (1),877 Air Flow Rate, scfm (Nm /hr) 1 (7) Air Pressure Drop, "w.c. (mbar) Maximum Heat Transfer, MMBTU/hr (kw) Maximum Burner Firing Demand, MMBTU/hr (kw) Gas Pressure Requirement into Valve Train Fuel Options. (.) 1.1 1. (81) Combustion Air Blower Motor Rating, bhp (kw) () 11 (1),79 (7). (11.) 1. (81) 1. () 7 (8),91 (1) 1.9 (.7) 1.8 (8).1 (1) psig ( mbarg) 9,9 (1). (8.). (8). (7) 7 (8), (81). (.). (7).9 (8) 9 9, (119). (8.7).8 (81). (98) 719 (8) 7,98 (118). (.). (97).9 (11) See Design Guide 11, to be used in conjuction with the following curves, to complete design and selection. All information is based on laboratory testing with neutral (." w.c.) exhaust conditions. All inputs based upon gross calorific values and standard conditions: 1 atmosphere, 7 F (1 C). Plumbing of gas will affect accuracy of orifice readings. All information based on general acceptable air and gas piping practices. Custom designs incorporating larger units or multiple units are available for needs greater than above maximums. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. (1) 1, (19).9 (9.7).8 (111). (19) Natural Gas, Propane, Butane (Contact Eclipse for others.) Recirculation Air Fan Motor Rating, bhp (kw) Unit Weight, lbs,1 (kg) (78) 7. 7, 7. 7. 1 11,8 (7) 7. 1 (1) 1,778 () 1 71 (79) 1,1 (198). (.). (119). (1) 1 (1) 1,1 (7) 1,89 (1). (1.7). (1). (178) (1) 77 (8) 1,88 (1899). (.). (1817) 7. (19) (1) (1) 19,1 (889) 7 (),1 (98).8 (1.) 7. (11) 8. 7 (8) 19, ().7 (.7) 8. (91) 1.1 (9) () 9 1,7 (). (1.) 9.8 (87) 11. (1), (119) 7 (8), (11).7 (.7) 11.7 (9) 1.8 () (7) 7, (8). (1.) 1. (9) 1. (7) (),7 (18)

High Efficiency (/8" Spacing Heat Exchanger) Parameter Air Delivery Temp., F ( C) 1 scfm referenced to 7 F at 1 atmosphere (1.9 psia), Nm /hr referenced to C at 1 atmosphere (.989 bar). Assuming - VAC / Phase / Hz electrical power. Please contact Eclipse for other electrical power options. unit uses two HP (18. kw) motors. All weights are approximate. See Design Guide 11, to be used in conjuction with the following curves, to complete design and selection. All information is based on laboratory testing with neutral (." w.c.) exhaust conditions. All inputs based upon gross calorific values and standard conditions: 1 atmosphere, 7 F (1 C). Plumbing of gas will affect accuracy of orifice readings. All information based on general acceptable air and gas piping practices. Custom designs incorporating larger units or multiple units are available for needs greater than above maximums. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. The performance curves below assume the following: - Fuel is natural gas - Burners are operated at % excess air - System elevation is at sea level - Process air enters ER Heater at 7 F (1 C), dry ER Heater Size (1 through 8) and Burner Size (Small or Large) 1 7 8 Small Large Small Large Small Large Small Large Small Large Small Large Small Large Small Large 89 (),877 Air Flow Rate, scfm (Nm /hr) 1 (7) Air Pressure Drop, "w.c. (mbar) Maximum Heat Transfer, MMBTU/hr (kw) Maximum Burner Firing Demand, MMBTU/hr (kw) Gas Pressure Requirement into Valve Train Fuel Options. (.7) 1. () 1. () Combustion Air Blower Motor Rating, bhp (kw) () 9,79 (7). (11.) 1. (1) 1.7 (98) 778 (1),91 (1). (.). (8). (7) psig ( mbarg) 1 (7),9 (1). (1.).. (7) 777 (1), (81). (.).7 (791).1 (99) 1 (7) 9, (119). (1.7).1 (99). (1) 77 (1) 7,98 (118).9 (7.). (1). (11) 1 () 1, (19).8 (1.). (11).7 (177) Natural Gas, Propane, Butane (Contact Eclipse for others.) Recirculation Air Fan Motor Rating, bhp (kw) Unit Weight, lbs,9 (kg) (8) 7. 7,88 (1) 7. 7. 1 1,7 (7) 7. 1 (1) 1, (1) 1 771 (11) 1,1 (198). (8.). (1).8 (17) 1 (1) 1,9 (78) 8 1,89 (1). (1.).7 (171). (19) (1) 78 (1) 1,88 (1899).1 (7.7).9 () 8. (1) (1),1 (917) 1 (8),1 (98).7 (1.) 7.9 (1) 8.9 (8) 77 (1) 19, (). (8.7) 9. (7) 1.9 (19) () 1 (7) 1,7 (). (1.7) 1.7 (1) 1. (7), (11) 777 (1), (11). (8.) 1.9 (781) 1. (9) (7) 1 (7), (8). (1.) 1.7 (8) 1.7 (89) (),187 (1) Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1

8 Process Air Outlet Temperature vs. Process Air Flow Rate 1/" Exchanger Plate Spacing 7 Process Air Outlet Temperature ( C) 1 Process Air Outlet Temperature F Size Size 1, 1, 1,,,,,,, 1,,,,,, 7, 9 Process Air Outlet Temperature vs. Process Air Flow Rate /8" Exchange Plate Spacing Process Air Outlet Temperature ( C) Process Air Outlet Temperature F 8 7 Size Size 1 1, 1, 1,,,,,,, 1,,,,,, 7, Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1

7 Process Air Pressure Drop vs. Process Air Flow Rate 1/" Exchanger Plate Spacing 1 Process Air Pressure Drop (mbar) 1 9 Process Air Pressure Drop "wc Size Size 1, 1, 1,,,,,,, 7 1,,,,,, 7, Process Air Pressure Drop vs. Process Air Flow Rate /8" Exchanger Plate Spacing Process Air Pressure Drop (mbar) 1 1 9 Process Air Pressure Drop "w.c. Size Size 1 1 1 1,,,,,, 7, Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1

.8 Process Air Outlet Temperature Correction Factor vs. Data Point Number Outlet Temp Correction Factor, F t.7......1 1/" Exchanger /8" Exchanger F: T co actual = T co curve + F t (T ci actual - 7) C: T co actual = T co curve + F t (T ci actual - 1) Where: - T co actual = Process Air Outlet Temp - Actual - T co curve = Process Air Outlet Temp - Curve - T ci actual = Process Air Inlet Temp - Actual - F t = Process Air Inlet Temp Correction Factor - Performance Curve Data Points are numbered left-to-right, 1 thru.. 1 Performance Curve Data Point Number 1.1 Process Air P Correction Factor vs. Inlet Temperature 1. P Correction Factor, F dp 1..9.9.8 P actual = F dp P curve.8 - - 8 1 1 Process Air Inlet Temperature, T ci F - - - -1 1 Process Air Inlet Temperature, T ci ( C) Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1

18 Burner Firing Rate vs. Process Air Flow Rate 1/" Exchanger Plate Spacing 8 1 1 Gross Firing Rate (kw) 18 1 Gross Firing Rate MMBTU/hr 1 1 8 Size Size, 1, 1,,,,,,, 1,,,,,, 7, 8 18 1 Burner Firing Rate vs. Process Air Flow Rate /8" Exchanger Plate Spacing Gross Firing Rate (kw) 18 1 Gross Firing Rate MMBTU/hr 1 1 1 8 Size Size, 1, 1,,,,,,, 1,,,,,, 7, Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1

Table 1 Burner Options ER Heater 7 8 Small Burner Maximum Demand, MMBTU/hr 1...1..8 8. 1.9 1. Maximum Demand, kw 7 99 11 17 19 9 Winnox Burner with Package Blower WX WX WX WX WX WX8 N/A N/A Winnox Burner with External Blower N/A N/A N/A N/A N/A N/A WX8 N/A Minnox Burner with External Blower CCS 7 CCS 1 CCS-T 1 CCS-T 17 CCS-T CCS-T CCS-T CCS-T Large Burner Maximum Demand, MMBTU/hr 1.7...7. 8.9 1. 1.7 Maximum Demand, kw 98 7 1 177 19 8 7 89 Winnox Burner with Package Blower WX WX WX WX WX8 N/A N/A N/A Winnox Burner with External Blower N/A N/A N/A N/A N/A WX8 N/A N/A Minnox Burner with External Blower 7 CCS 1 CCS-T 1 CCS-T 17 CCS-T CCS-T CCS-T CCS-T CCS-T Eclipse ER Indirect Air Heater, V1, Data 11, 1/8/1 7

Dimensions System Using Winnox Burners (Low Emissions) H W L System Using Minnox Burners (Ultra Low Emissions) H W L Size Length L Inches (m) Width W Inches (m) Height H Inches (m) 1 177 (.9) 1 (1.) 98 (.9) 198 (.) (1.1) 1 (.9) 9 (.1) (1.) 11 (.87) (.7) (1.) 11 (.9) 9 (.7) 7 (1.8) 119 (.) (.8) 8 (.1) 19 (.) 7 8 (.81) 1 (.) 19 (.) 8 7 (.98) 1 (.) 19 (.) Data 11, 1/8/1

Offered By: Power Equipment Company 11 Williamsburg Road Richmond, Virginia 1 Phone (8) -8 Fax (8) -88 www.peconet.com