805QS Pressure Switch-Transmitter

Similar documents
1510 Side Mounted Level Switch

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

DB5 Intrinsically Safe Sounder Type DB-5

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

IECEx Certificate of Conform ity

Rosemount 2051G Pressure Transmitter

OPTIBAR DP 7060 Supplementary Instructions

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Certificate of Compliance

Ultrasonic Point Level Switches

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX / IECEx)

Certificate of Compliance

Ultrasonic Switches. Features & Benefits

Indoor/outdoor resistance thermometer Model TR60

Rosemount 702 Wireless Discrete Transmitter

Quick Start Guide For the

Model 144H. Product Data Sheet , Rev DB February Content

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Model 144H. Product Data Sheet , Rev DB February Content

OPTIWAVE X500 Supplementary Instructions

Annubar Flowmeter Series

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Fisher LCP100 Local Control Panel

! WARNING. Before using product, read and understand instructions.

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Druck DPI 705/DPI 705 IS Series

! WARNING. Before using product, read and understand instructions.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 2090P Pulp and Paper Pressure Transmitter

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

! WARNING. Before using product, read and understand instructions.

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 644 Temperature Transmitter

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

4) Intrinsic Safety Certification

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

INSTRUCTION MANUAL (ATEX / IECEx)

Rosemount 3051HT Hygienic Pressure Transmitter

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

INSTRUCTION & SERVICE MANUAL

Manual Power relay SR853

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Rosemount 752 Remote Indicator

NT DUAL CHANNEL DISPLAY. User Guide

Duct and Rough Service Carbon Monoxide Sensor

VERSAFLOW VORTEX Supplementary instructions

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Rosemount 4500 Hygienic Pressure Transmitter

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Installation and Operating Instructions

MAN0604_Issue 09_ Apex

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Certificate of Compliance

Instructions. Explosion Proof Smoke Detector U Rev: 9/

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Flameproof Manual Call Points

Rosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

OPTISENS TUR 2000 Technical Datasheet

PTE0705 Electric Fence Monitor

IECEx Certificate of Conformity

FlameHawk ATEX / IEC Ex Model

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Vanguard. Toxic & combustible gas detector

Rosemount 2090F Hygienic Pressure Transmitter

Gas cylinder scale Model GCS-1

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Hazardous Area Zirconia Oxygen Systems

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

PPA Michaël GROSSI - FSCE PR electronics

Transcription:

805QS Pressure Switch-Transmitter These instructions provide information for installation, process connection, n, electrical connection, operation and maintenance of the 805QS pressure switch-transmitter. The 805QS consists of a field proven sputtered thin film stainless steel pressure transducer and a reliable switching output. The housing features a stainless steel construction. General Instructions The 805QS is capable of powering long cable lengths. See Formula on page 3 for maximum loop resistance. NOTE: If you suspect that an instrument is defective, contact the factory or the SOR representative in your area for a return authorization number (RMA). This product should only be installed by trained and competent personnel. Design and specifications are subject to change without notice. For latest revision, go to SORInc.com Table of Contents Installation...1 Additional Install Steps for Dual Seal Units...2 Electrical Termination - 805QS-C...3 Electrical Termination - 805QS-V...4 Switch Operation...4 Dimensions...6 Maintenance...7 ATEX Marking Details...7 Declaration of Conformity...8 Installation Ensure that wiring conforms to all applicable local and national electrical codes and install unit(s) according to relevant national and local safety codes. Normally, line mounting provides adequate support for the instrument. 1st Step: Make the Process Connection The process connection is threaded onto a fitting within an adequately supported process piping system. Use two open end wrenches when connecting the pressure port to a process piping system: one wrench to hold the process fitting, the other at the hex flat to tighten the electronic pressure switch-transmitter. Process connection pipe or tubing may be rigid or flexible. NOTE: Do not use the 1/2 NPT(M) connection on pressures higher than 5000 psi. Form 1547 (03.18) SOR Inc. Registered Quality System to ISO 9001 1/8

2nd Step: Make the Electrical Connection The electrical connection may be installed on an adequately supported rigid conduit system. Use suitable locknuts (not provided) when mounting the instrument to an unthreaded (knockout) hole. Securely connect the conduit pipe or fitting by holding the flats on the electrical connection while tightening. Electrical connection may be rigid or flexible conduit. Unit in Hazardous Locations - Prior to removal from service, make sure that the work area is declassified. Failure to do so could result in severe personal injury or substantial property damage. Additional Install Steps for Dual Seal Units Failure to follow these additional installation instructions may diminish the Ingress Protection and NEMA ratings of the Dual Seal instruments. An improper installation will void the warranty. Vertical Installation The figure on the right depicts the vertical installation profile; with the electrical leads on top. The instrument may be installed with the electrical leads on the bottom. The nameplate (tag) should cover the set screw (annunciation path). Position the nameplate slot opposite the set screw; i.e., the nameplate slot should be located 180 from the set screw. EXTERNAL GROUND PROVISION SET SCREW ANNUNCIATION PATH NAMEPLATE AREA 2/8 Form 1547 (03.18) SOR Inc.

Horizontal Installation The following figure depicts the proper horizontal installation profile; with the external ground provision and set screw (annunciation path) oriented downward. The nameplate (tag) should not cover the set screw. Align the nameplate slot with the set screw; i.e., the set screw should be visible in the nameplate slot. NAMEPLATE AREA EXTERNAL GROUND PROVISION SET SCREW ANNUNCIATION PATH Electrical Termination - 805QS-C 72 flying leads are provided for connection to a terminal strip within a cabinet or a splice within an outlet box: Red (+) Black ( ) Orange Yellow Blue Green White Brown Bare } } Loop Voltage: 8 to 30 VDC Output: 4 to 20 ma Switch Contacts Normally-Open Solid-State Relay (Used for 805QS-V Models Only) Earth Ground Calibration (Requires SOR Calibration Kit) Not Used (trimmed at factory) Drain Wire - Connected to Earth Ground (trimmed at factory) NOTE: An external ground screw is included for additional earth ground connection. Drawing 0190323 Formula for determining maximum loop resistance R L (MAX) = V Supply - 8V 20mA Form 1547 (03.18) SOR Inc. 3/8

Electrical Termination - 805QS-V 72 flying leads are provided for connection to a terminal strip within a cabinet or a splice within an outlet box: Red (+) Black ( ) Orange Yellow Blue Green White Brown Bare } } 8-30 VDC + Power Connection Power Supply Ground Switch Contacts; Normally-Open Solid-State Relay 1-5 VDC Output Earth Ground Calibration (Requires SOR Calibration Kit) Not Used (trimmed at factory) Drain Wire - Connected to Earth Ground (trimmed at factory) Drawing 0190323 NOTE: An external ground screw is included for additional earth ground connection. Switch Operation The 805QS switch output is a solid state, normally open relay that is rated to 30V, 120mA. This switch can be configured three different ways depending on your application requirements as noted below. Specific switch action can be requested at the time of order or can be selected via the optional SOR Calibration Kit at any time. In all three configurations, the fail-safe state for the 805QS switch output will be open (i.e., if power is removed from the 805QS, the switch contacts will open automatically). Please note that the 805QS has a ± 2% URL accuracy tolerance around each switch setpoint. For best results, SOR recommends the use of some form of switch latching logic in conjunction with the 805QS. NOTE: Make certain you are using SOR Calibration Manager software version 3.0.0.6 or greater. Pressure Window Monitoring This is the default configuration for the 805QS switch output. In this mode the switch output is closed when the process pressure is within a user selectable range and open when the pressure is outside of these boundaries. This is designed for applications where there is a known acceptable operating pressure range. For example, the window could be set for an acceptable operating range of 50PSI to 150PSI. The 805QS switch output will be closed when the pressure being monitored is between 50 and 150 PSI. If the pressure goes below 50PSI or above 150PSI, the 805QS switch output will open. (See ) 4/8 Form 1547 (03.18) SOR Inc.

Window Mode Single Point: Close on Rise/Open on Fall In this configuration, the switch output will be open for pressures less than the selected setpoint. The switch output would then be closed for pressures greater than the setpoint. (See ) Single Point: Open on Rise/Close on Fall In this configuration, the switch output will be closed for pressures less than the selected setpoint. The switch output would then be open for pressures greater than the setpoint. (See ) Once the switch is installed and wired into a control or display loop, it is ready for use. Before applying power, check that the polarity and excitation voltage are correct. Form 1547 (03.18) SOR Inc. 5/8

Dimensions Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. ELECTRICAL CABLE ELECTRICAL CONNECTION 1/2 NPTM 28.6 1-1/8 WRENCH FLATS EXTERNAL GROUND PROVISION NAMEPLATE 154.8 6-3/32 34.1 1-11/32 28.6 1-1/8 HEX PROCESS CONNECTION 1/2 NPTM W/1/4 NPTF Linear = mm/inches Drawing 0091438 6/8 Form 1547 (03.18) SOR Inc.

Maintenance The 805QS contains no user serviceable parts and cannot be repaired on site. It must be returned to the factory. Disassembly of the instrument by unauthorized persons will invalidate the warranty. If there is a risk of debris accumulating in the pressure port, it should be cleaned. Care and caution must be taken when cleaning the pressure port to prevent damage to the diaphragm. ATEX Marking Details For ATEX Certifi ed Models Drawing 720555 Manufacturer s Registered Trademark Thread Form Information Product Model Identification Serial Number (First Two Numbers Indicate Year of Manufacture) ATEX Listing Information Special Condition for Safe Use Flamepath joints are not intended to be repaired Form 1547 (03.18) SOR Inc. 7/8

ATEX Marking Details For ATEX Certifi ed Models EC Declaration of Conformity Product Manufacturer Date of Issue We declare that the above products conform to the following specifications and directives Carries the Marking Reference Documents 805QS Pressure Switch-Transmitter SOR Inc. 14685 West 105 th Street Lenexa, Kansas 66215-2003 United States of America December 18, 2017 ATEX Directive (2014/34/EU) EN 60079-0:2012 + A11:2013, EN 60079-1:2014 EN 60529:1991 + A1:2000 + A2:2002 EMC Directive (2004/108/EC) IEC 61326-1:2006, IEC 61000-4-2:2008 IEC 61000-4-3:2008, IEC 61000-4-4:2006 IEC 61000-4-5:2005, IEC 61000-4-6:2008 IEC 61000-4-8:2009 II 2 G Ex db IIC T5 Gb, Ta + -40 C to +80 C IP66 EC-Type Examination Certificate, FM 09 ATEX 0045 Issued September 29, 2009 EMC Test Report 7914-623 Issued September 24, 2009 ATEX Notified Body Baseefa Ltd. (Notified Body No. 1180) Rockhead Business Park, Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom Baseefa Customer Reference No. 1021 Person Responsible Michael J. Bequette (VP of Engineering) Michael J. Bequette Engineered to Order with Off-the-Shelf Speed 14685 West 105th Street, Lenexa, KS 66215-2003 Form 1548 (12.17) SOR Inc. Printed in USA SORInc.com 14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 USA Fax 913-888-0767 8/8 Registered Quality System to ISO 9001 Form 1547 (03.18) SOR Inc.