Description. Optex Incorporated

Similar documents
Advanced DIGITAL Wired PIR Motion Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

D-TECT Dual Tech. GJD360 Triple Technology External Detector

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

HX-80NRAM. High Mount Outdoor Detector

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

English. Italiano. Português. Françias. Español

LUX Hardwired - Installation Notes

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Movement Detector GJD 300

Extended Range DUAL TEC Motion Sensor

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

SECURITY PRODUCTS CATALOGUE

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

DI601AM Outdoor PIR/AM Detector Installation Sheet

1125 PIR Motion Detector

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

D-TECT 2 IP. GJD230 IP Motion Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Intrusion sensors. We listened to you

English. Series. Installation and Use Manual

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

D-TECT 3 IP. GJD260 IP Motion Detector

Passive Infrared Motion Detector 5420/90P. Installation Instructions

1126 Series Ceiling Mount PIR Motion Detector

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

KwêBeams Effective wire free outdoor early warning system

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Leading by technology

VX-402, VX-402REC CONTENTS FEATURES

Motion sensor technologies. Leading by technology

Intrusion Outdoor Protection Perimeter

Hardwired Alarm Accessories

Motion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.

STANDARD FEATURES SPECIFICATIONS

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

S P A C E D E T E C T I O N

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

DD205RF/TX Detector Installation Sheet

SYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)

General Description. Industrial LuNAR DT AM Grade 3 Features

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

PIR-100B User Manual

Commercial Series TriTech Motion Detector. Reference Guide

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

>WIRELESS> ALARM SYSTEM CR200

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

Quadruple-beam photoelectric detector

DS160/161 Request To Exit PIR sensors Installation Instructions

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

DS160/DS161 Request To Exit PIR sensors Installation Instructions

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Installation Instructions

Sensors. Supplied by: User Interfaces. Networked Controls Product Catalogue

SECURITY PRODUCTS CATALOGUE

Model 3300 Technical Support and Installation Manual

Open-area Smoke Imaging Detection (OSID)

Twin Photobeam Detectors Manual

NetworX NX-548E Receiver Installation Instructions

Installation Manual Premier Elite Orbit QD/DT INS483-2

Viewguard Motion detctors PIR and DUAL detectors

Immunity. P/N: ver.b

Quick Selection Guide Intrusion Detectors

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

LS800S Intruder Alarm System. Engineering Manual

Table of Contents. Intrusion Detectors... I-1. Intrusion Panels... II-1. Type Index... III-1

Wireless D.I.Y. Alarm Kit

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

77167 INTRUDER /3/08 12:57 Page INTRUDER

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Commercial Series TriTech+ Motion Detector with Anti-mask

EXTRA WIDE ANGLE ARRAYS EWA 0.3 GI V1 EWA 0.53 GI V1 EWA 1.35 GI V1 ANIMAL ALLEY ARRAYS AA 0.53 GI V1 AA 0.53 GI M1 AA 0.9 GI M1.

Photoelectric Beam Detector

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

Wireless security products

Installation And commissioning manual. Series S Double Beam 1/16

Transcription:

Optex Incorporated Description 1845 W. 205 th St. Torrance, CA 90501-1510 USA TEL (310) 533-1500 and (800) 966-7839 FAX (310) 533-5910 Doc: Model: Desc: Architect/ Engineer Specifications CX-502 PIR Intrusion Detector NOTE: Words/statements within square brackets [ ] may be included when appropriate, or when selection is required. The Intrusion Detector[s] shall operate on the Verified Intrusion principle using Passive Infrared (PIR), and shall be Listed by Underwriter's Laboratories, Inc.. OUTPUT AND ENCLOSURE [Each] [The] detector shall provide the detection, signal processing, alarm relay, and operating power circuitry in the same enclosure; and shall provide an alarm relay actuation upon the detection of an intruder moving into or through its protection pattern. The enclosure shall be ready for surface and/or corner mounting, and shall be capable of mounting to a compatible Wall or Ceiling Mounting Bracket without modification. The total weight shall be 4.2 oz. (120g). [Each] [The] detector shall feature a single piece electronics board whose circuitry is specifically designed for this detector alone. The board shall be mounted to a housing with the cover being secured with a screw. The case shall include easy wiring knockouts. LED OPERATION [Each] [The] detector shall incorporate a single, Red LED to indicate the operating conditions. Red LED illuminated shall indicate an alarm condition. Red LED not illuminated shall indicate a non-alarm condition. The LED Alarm Indicator shall be optional; it shall be capable of being field disabled using an On/Off pin switch, or remotely from the control panel. POWER REQUIREMENT The detector[s] shall be capable of operating from a DC power source rated within the range of 9 to 18 volts DC, and draw a nominal 5mA (normal) and 12mA (maximum) within this range. ALARM OPERATION A condition of alarm shall occur when the PIR alarm conditions are met. The Detectable Speed shall be 1 ~ 5 ft/sec. (0.3 ~ 1.5m/sec.). The Alarm Period shall be approx. 2.0 ±.5 seconds. The Alarm Output shall be capable of handling 28VDC, 0.2A max, N.C.. The Alarm Sensitivity shall be 3 F (1.6 C) at 2ft/sec. (0.6m/sec.). A sensitivity adjustment switch shall include settings of L(Low) or H(High) for times when the detector is installed in a hostile area, and times when greater sensitivity is required. The Alarm output shall be 28VDC, 0.2A max. [Each] [The] detector shall signal the condition of alarm using a Normally Closed Reed Relay with terminal strip connections. The detector[s] shall also contain a tamper switch that shall open when the cover is removed. To accomplish PIR detection, [each] [the] detector shall contain a sealed Pyro- Electric sensor peaked for the detection of near-infrared energy in the 10 micron region. SENSOR STABILITY The PIR detection shall use Quad Zone Logic Signal Processing. Quad Zone Logic provides multi segmented detection zones Doc #: 3440-0330

over the detection area. An alarm signal shall be created by the cumulated total IR energy of each zone. It is designed so that a human size target will normally fill 4 to 8 zones, and this shall cause an alarm to be generated. Any smaller temperature change (i.e. small to medium size pets, rodents or moving curtains) shall only activate one or two zones at the same time, creating a much weaker detection signal. Pet immunity shall apply to animals and/or rodents 0 to 16 inches in height. To guard against false activations caused by RF interference, the detector shall incorporate RFI Protection capability that cancels over 50% of popcorn noise. This noise reduction circuitry shall adjust to background disturbances, in order to help reduce false activations while maintaining catch performance. No alarm shall occur at 30V/m within the range of 144 to 1,200MHz. A Temperature Compensation Circuit shall also increase detection capability under high temperature conditions where the background temperature is similar to that of the human body. The patented multifocus lens creates zones with high vertical density, providing maximum detection sensibility that shall remain stable even in high, low, or changing temperature conditions. [Each] [The] detector shall be rated to operate within the temperature range of [minus 4 Fahrenheit to plus 122 Fahrenheit] [minus 20 Celsius to plus 50 Celsius]. [Each] [The] detector shall also tolerate an environmental humidity rate of 95% max. No false alarm shall occur within these operating conditions. [Each] [The] detector shall also feature Visible Light Protection capability. The patented Double Conductive Shielding of the Pyro Electric Element shall provide a high protection level that exceeds H4 halogen (car headlight) within 8ft (2.4m) or 50,000lx of reflected sunlight within the detection area. Sealed optics shall also eliminate the chance of false alarm due to drafts or small insects. The Pyro shall be sealed with the inside of the molding of the housing cover, to prevent these elements from affecting the pyroelectic sensor. To ensure proper circuit operation, the detector[s] shall incorporate a PIR self-test with defaults. When the device is turned on, the warm-up period shall be approx. 1 minute, during which time the LED shall blink. LENS AND DETECTION PATTERN [Each] [The] detector shall contain a front mounted hard and durable spherical Fresnel lens that shall focus received infrared energy onto the sensor. The spherical design of this lens shall obtain sharp detection, because no bending is required to fit the lens into the curved housing. The sensor and module combined shall construct a Wide Angle detection field 50ft x 50ft (15m x 15m), or 85 wide, with 82 zones of detection. A Long Range detection pattern shall also be available through the CL-80N (Optional Lens for Long Range Curtain Pattern). In long mode, the coverage pattern shall be 80ft x 8ft (24m x 2.4m) long, with 22 detection zones. When selecting the Long Range detection pattern, the pulse count selector shall be set to STD. The mounting height of the detector[s] shall be between 6 ~ 10ft (1.8 ~ 3.0m) High. MODEL The Intrusion Detector shall be model CX-502 (standard), [with] [optional Wall Mount Bracket EA-1], [or] [with optional Multi Angle Wall Bracket FA-1W], [or] [with optional Multi Angle Ceiling Bracket FA-2C], [or] [with optional Long Range Lens [CL- 80N]. Doc #: 3440-0330

Optex Incorporated Description 1845 W. 205 th St. Torrance, CA 90501-1510 USA TEL (310) 533-1500 and (800) 966-7839 FAX (310) 533-5910 Doc: Model: Desc: Architect/ Engineer Specifications CX-502AM PIR Intrusion Detector NOTE: Words/statements within square brackets [ ] may be included when appropriate, or when selection is required. The Intrusion Detector[s] shall operate on the Verified Intrusion principle using Passive Infrared (PIR), and shall be Listed by Underwriter's Laboratories, Inc.. OUTPUT AND ENCLOSURE [Each] [The] detector shall provide the detection, signal processing, alarm relay, and operating power circuitry in the same enclosure; and shall provide an alarm relay actuation upon the detection of an intruder moving into or through its protection pattern. The enclosure shall be ready for surface and/or corner mounting, and shall be capable of mounting to a compatible Wall or Ceiling Mounting Bracket without modification. The total weight shall be 4.8 oz. (135g). [Each] [The] detector shall feature a single piece electronics board whose circuitry is specifically designed for this detector alone. The board shall be mounted to a housing with the cover being secured with a screw. The case shall include easy wiring knockouts. LED OPERATION [Each] [The] detector shall incorporate dual, Red and Yellow LED to indicate the operating conditions. Red LED illuminated shall indicate an Alarm, Alarm Memory, or initial Alarm Memory condition. Red LED not illuminated shall indicate a non-alarm condition. Yellow LED shall indicate Anti- Masking and Self-Checking. During the warm-up period, both Red and Yellow LED shall blink. The LED Alarm Indicator shall be optional; it shall be capable of being field disabled using an On/Off DIP switch, or remotely from the control panel. POWER REQUIREMENT The detector[s] shall be capable of operating from a DC power source rated within the range of 9 to 18 volts DC, and draw a nominal 7mA (normal) and 19mA (maximum) within this voltage range. ALARM OPERATION A condition of alarm shall occur when the PIR alarm conditions are met. The Detectable Speed shall be 1 ~ 5 ft/sec. (0.3 ~ 1.5m/sec.). The Alarm Period shall be approx. 2.0 ±.5 seconds. The Alarm Output shall be capable of handling 28VDC, 0.2A max, N.C.. [Each] [The] detector shall signal the condition of alarm using a Normally Closed Reed Relay with terminal strip connections. The Alarm Sensitivity shall be 3 F (1.6 C) at 2ft/sec. (0.6m/sec.). A sensitivity adjustment switch shall include settings of L(Low) or H(High) for times when the detector is installed in a hostile area, and times when greater sensitivity is required. The detector[s] shall also contain a tamper switch that shall open when the cover is removed. To accomplish PIR detection, [each] [the] detector shall contain a sealed Pyro- Electric sensor peaked for the detection of near-infrared energy in the 10 micron region.

[Each] [The] detector shall contain an alarm memory with a selectable polarity. When the system is armed and the polarity is positive, the detector[s] shall include a memory of an OPEN current or +5 ~ 18V DC. When the system is armed and the polarity is negative (DIP switch selectable), the detector[s] shall include a memory of 0 ~ 1V DC (grounded). When the system is disarmed, these values for positive and negative shall be reversed. SENSOR STABILITY The PIR detection shall use Quad Zone Logic Signal Processing. Quad Zone Logic provides multi segmented detection zones over the detection area. An alarm signal shall be created by the cumulated total IR energy of each zone. It is designed so that a human size target will normally fill 4 to 8 zones, and this shall cause an alarm to be generated. Any smaller temperature change (i.e. small to medium size pets, rodents or moving curtains) shall only activate one or two zones at the same time, creating a much weaker detection signal. Pet immunity shall apply to animals and/or rodents 0 to 16 inches in height. To guard against false activations caused by RF interference, the detector shall incorporate RFI Protection capability that cancels over 50% of popcorn noise. This noise reduction circuitry shall adjust to background disturbances, in order to help reduce false activations while maintaining catch performance. No alarm shall occur at 30V/m within the range of 144 to 1,200MHz. A Temperature Compensation Circuit shall also increase detection capability under high temperature conditions where the background temperature is similar to that of the human body. The patented multifocus lens creates zones with high vertical density, providing maximum detection sensibility that shall remain stable even in high, low, or changing temperature conditions. [Each] [The] detector shall be rated to operate within the temperature range of [minus 4 Fahrenheit to plus 122 Fahrenheit] [minus 20 Celsius to plus 50 Celsius]. [Each] [The] detector shall also tolerate an environmental humidity rate of 95% max. No false alarm shall occur within these operating conditions. [Each] [The] detector shall also incorporate Multi Anti-Masking optical technology to further prevent disturbances with detection. The twin-window shall detect with high sensitivity the variations of optical signals as well as the optical direction differences caused by two photoelectric beams. [Each] [The] detector shall also feature Visible Light Protection capability. The patented Double Conductive Shielding of the Pyro Electric Element shall provide a high protection level that exceeds H4 halogen (car headlight) within 8ft (2.4m) or 50,000lx of reflected sunlight within the detection area. Sealed optics shall also eliminate the chance of false alarm due to drafts or small insects. The Pyro shall be sealed with the inside of the molding of the housing cover, to prevent these elements from affecting the pyroelectic sensor. To ensure proper circuit operation, the detector[s] shall incorporate a PIR self-test with defaults. When the device is turned on, the warm-up period shall be approx. 1 minute, during which time the LED shall blink. A self-checking circuit shall also check the operation of the detector[s] at regular 5-hour intervals to ensure that the unit is always working correctly. LENS AND DETECTION PATTERN [Each] [The] detector shall contain a front mounted hard and durable spherical Fresnel lens that shall focus received infrared energy onto the sensor. The spherical design of this lens shall obtain sharp detection, because no bending is required to fit the lens into the curved housing. The sensor and module combined shall construct a Wide Angle detection field 50ft x 50ft (15m x 15m), or 85 wide, with 82 zones of detection. A Long Range detection pattern shall also be available through the CL-80N (Optional Lens for Long Range

Curtain Pattern). In long mode, the coverage pattern shall be 80ft x 8ft (24m x 2.4m) long, with 22 zones of coverage. When selecting the Long Range detection pattern, the pulse count selector shall be set to STD. The mounting height of the detector[s] shall be between 6 ~ 10ft (1.8 ~ 3.0m) High. MODEL The Intrusion Detector shall be model CX-502AM (Anti-Masking), [with] [optional Wall Mount Bracket EA-1], [or] [with optional Multi Angle Wall Bracket FA-1W], [or] [with optional Multi Angle Ceiling Bracket FA-2C], [or] [with optional Long Range Lens [CL- 80N].