l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Similar documents
DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

English. Italiano. Português. Françias. Español

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Active Infrared Multi Beam Sensors

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Active Infrared Multi Beam Sensors. R Series

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Movement Detector GJD 300

Installation Instructions

Description. Optex Incorporated

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

HX-80NRAM. High Mount Outdoor Detector

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FADEMC~I ULTRASONIC MOTION DETECTORS

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Passive Infrared Motion Detector 5420/90P. Installation Instructions

DUAL OPTIC. Installation manual

Basic Vehicle Fire Protection Manual

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

LUX Hardwired - Installation Notes

An Ambient-Light-Ignoring Infrared Active Motion Detector

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

ULTRASONIC MOTION DETECTORS 1 r\,:

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

1125 PIR Motion Detector

Installation Instructions

Advanced DIGITAL Wired PIR Motion Detector

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Pyroelectric Infrared Sensor PIR

PIR-100B User Manual

KwêBeams Effective wire free outdoor early warning system

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Commercial Series TriTech Motion Detector. Reference Guide

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Installation Operation Maintenance

FR-A180 FR-A360. Occupancy detector. Use

Detector Application Notes

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Reflective Beam Smoke Detector

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

USER MANUAL 10 YEAR LIFE SMOKE ALARM

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation and Operation Manual

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Addressable Detectors & Bases

PERMACONN PM1030 Includes DI300. Installation Manual

DI601AM Outdoor PIR/AM Detector Installation Sheet

Design Manual Installation Operation Maintenance

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

DS160/DS161 Request To Exit PIR sensors Installation Instructions

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

DS160/161 Request To Exit PIR sensors Installation Instructions

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Intrusion Outdoor Protection Perimeter

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INTRUDER ALARM FOR BUSINESS SECURITY

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

AP Air Ion Counter Instructions

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Table of Contents. 1. Mounting Tips... 2

Commercial Series TriTech+ Motion Detector with Anti-mask

BB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION. Greer Company Crane Systems. Greer Company

Public Safety DAS Annunciator Panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Addendum for STI-6406 with Dual Access Control

180 Degree Ceiling Mounted Occupancy Sensors

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

MODEL B2 INSTALLATION MANUAL

Remote Display Alarm Indicator for Oxygen monitor

Infrared Wall Mount Occupancy Sensor

D2E Duct Smoke Detector

VX-402, VX-402REC CONTENTS FEATURES

Total Connect Box. User manual

D-TECT 2 IP. GJD230 IP Motion Detector

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

Transcription:

GENERAL INFORMATION: The No. 1852 provides 12 zones of coverage with a range of up to 25 feet (at a typical mounting height of 7-0 ). This model has the following important features: l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor. l Low current drain which allows for extended system power source battery life. 6 Pm-set zones for fast and easy installation. l Walk-test LED l Optional wall/corner mounting plate. The No. 1852 must be powered from a filtered 6V. DC or 12V. DC source that can provide at least 4 hrs. of standby power. The No. 495 Power Supply, which can be plugged directly into any 24 hour 120V. AC outlet, can be used as a convenient source of 6V. DC, having up to 12 hours standby. The detector is designed to operate at all times. When motion is detected, the unit s LED will light and its relay contacts will transfer. PRINCIPLES OF OPERATION: The optical system divides the area into a series of protected zones. A speoial sensor measures the level of infrared energy in each zone. When an intruder crosses or enters any zone, the resulting change in infrared energy is detected and an alarm condition will be reported. The sensor does not respond to visible light or slow changes in the background temperature of the area. Because a passive infrared device employs no transmission of any kind, any number of units may be used in the same area. Far infrared energy does not penetrate most building materials (even window glass) so the unit responds primarily to movement within the protected area. COVERAGE CONSIDERATIONS AND TYPICAL LAYOUTS: The pattern of protection provided by the No. 1852 includes six main zones which span an angle of approximately 60, and six downward zones aligned in the same direction horizontally as the main zones. See Diagrams 1 and 2. The optical system has been designed to give a coverage range of 25 based on a typical mounting height of 7 ; however, the unit may be mounted at other heights with modified range coverage as shown in Diagram 3. Selecting a Mounting Location: Because the No. 1852 Passive Infrared Detector responds to changes in energy which occur when an intruder moves into or out of a zone, best coverage will be obtained if the mounting site is selected such that the likely direction of intruder motion is ACROSS the pattern, rather than toward or away from the unit. Avoid direct viewing, by the unit, of heat sources such as radiators, heating ducts, direct sunlight, etc. IkTALLATlON AND WIRING: Passive I.R. units are remarkably resistant to false alarm hazards but the following recommendations should be observed: Avoid locating unit where central heating radiators, live fires or heating outlet ducts could be within the protective zones. Avoid locating the unit in direct sunlight or directly above strong sources of heat. Avoid locating unit on unstable surfaces. Avoid running alarm wiring close to heavy duty electrical cables. Mounting: IMPORTANT: Be careful during installation or adjustment NOT TO TOUCH THE REFLECTOR OR SENSOR SURFACES. The No. 1852 should be mounted to a firm and vertical surface. It may be mounted flat on a wall or in a comer, either directly to the mounting surface or via an optional mounting plate (No. 652MP). Alternatively, for recessed mounting, a flush mounting kit (No. 652MK) is available. A. Mounting Directly to Surface: 1. Remove cover of unit by loosening the retaining screw. 2. Remove electrical assembly by a) spreading tips of plastic holding prongs outward (see Diagram 4), b) grasping metal n shield and c) pulling assembly out of case. First, with finger or screwdriver, pull one prong toward edge of case and pull out ; side of shield at that edge. Repeat with other prong and other side of shield. Then pull out assembly. At this point it should slide easily out of case. 586 577 \

3. Punch out 2 knockout holes at each edge of rear of case as follows: a. If unit is to be mounted on flat surface, punch out inner (round) holes. b. If unit is to be mounted at comer of wall, punch out outer (angled, square) holes. \ 4. Using knocked out holes as guide, drill appropriate mounting holes on wall at the recommended height and fasten, unit to wall. 5. Replace electrical assembly and proceed with Wiring. 8. Mounting with Optional No. 652MP Mounting Plate: 1. Mount the plate to a firm and vertical surface (flat on wall or in comer). as shown in Diagram 4, at the recommended height (see previous section). Orient the plate so that the rectangular cutout in the plate is at the bottom. If wiring is provided from a hole in the mounting surface, locate the mounting p!ate so that the wiring hole is centered horizontally within the rectangular cutout in the plate and the bottom edge of the plate is positioned in-line with the center of the wiring hole. See Diagram 4, Detail A. This will align the wiring hole with the wiring entry in the case when the unit is secured. Wiring holes should be no larger than %S in diameter. 2. Remove the front cover from the detector by loosening the retaining screw. 3. Attach the unit to the plate as follows: Engage all four hooks on the plate into the slots on the rear of the case (See Diagram 4) and secure the unit to the wall plate by pressing downward. Proceed with Wiring. C. Recessed Mounting (Optional): Use the No. 652MK flush Mounting Kit. Full instructions accompany it. Wiring Connections: Using the wire entry plug and the wiring entry access at the lower rear of the case, carefully feed the wires through the entry and along the underside of the terminal block. For surface wiring, a knockout is provided at the wiring entry access. Avoid unnecessary splices and loops within the unit. Check all connections carefully. See Diagram 5 for connections, which should be made in this order: 1. Alarm Relay Terminals: To connect a closed circuit protective loop, see diagram. 2. Input 6VH2M DC (+) and (-) Terminals: Connect these terminals to a 6V DC or 12V. DC source that can provide 35mA continuously. Note: For 12V DC operation, cut the unit s ORANGE jumper. Observe polarity! Continuous auxiliary capacity of applicable Ademco controls is as follows: No. 1021,462l : 4OOmA No. 1025 : 220mA 6V.DC No. 1022 : 150mA No. 4066466OXL : 5CtOmA No. 1023 : 600mA No. 33OR25,34OR25 : 256mA I No. 1024 : 200mA No. 332R50,342R50 : 750mA No. 1021-12,4021-12 : 400mA 12V.DC No. 1022-12 : 300mA No. 1023-12 : 550mA No. 1025-l 2,1025EX12 : 220mA 1 No. 4080-l 2 : 500mA Alternatively, 6V. DC can be conveniently provided directly from any 24 hour 12OV. AC outlet via a No. 495 Power Supply which plugs directly into the outlet. TESTING: IMPORTANT: Wait at least two minutes after connecting power before attempting to walk-test unit. Testing of the detector should be conducted with the protected area cleared of all people. In some business establishments, it will be more convenient to do this after the business is closed. The protective system s control should be OFF during the procedure to prevent reporting unwanted alarms. Walk Test: Double-check all connections. Replace the front cover and secure holding screw. Walk-test unit with cover in place. Test operation by walking through the protective zones and observing walk-test LED. The absolute range of all Passive I.R. units is subject to variation because of diierent types of clothing, backgrounds and ambient temperature changes. For this reason, ensure that the most likely intruder routes are well within the protective zones and that walk-testing is carried out along these routes. 587 578

Meter Test: (if required, for analyzing problem areas) Remove the front cover. Using a DC voltmeter (or multimeter, 20k ohms per volt, or equivalent) connect positive test lead to the Test Point post located behind terminal 1 on the printed circuit board (See Diagram 5). The meter s negative lead should be connected to the ( - ) input (ground) terminal 5. The meter should be set to the 2.5V DC range. Mask the detector s optics so that motion cannot be detected. The meter should indicate approximately 1.6V. DC (with a permissible normal fluctuation of approximately 0.1 V). Remove mask covering the optics, remain motionless and allow time for the meter to settle. Motion into any of the detector s zones should cause the meter to deflect above or below the 1.6V nominal level. Meter variation of 2 0.5 Volts should trigger the unit, causing the LED to illuminate and the alarm relay to transfer. MAINTAINING PROPER OPERATION AND COVERAGE: In order to maintain the detector in proper working condition, it is important that the following be observed by the user. 1. Power must be provided at all times. The unit s DC source must have standby power available for at least 4 hrs. of operation during emergencies. 2.. Units should never be re-aimed or relocated without the advice of the alarm company. 3. The physical surroundings of the protected area should not be changed. If furniture or stock is moved, or air conditioning or additional heating is installed, the system may have to be readjusted by the alarm service company. 4. Walk-tests should be conducted at least monthly to confirm continued proper coverage by each detector. TROUBLESHOOTING: Trouble 1: UNIT GOES INTO ALARM INTERMITTENTLY FOR NO APPARENT REASON AND WALK-TEST LIGHT GOES ON WHEN ALARM CONDl-RON EXISTS. A. Rapid change in I.R. level in a zone. Check for electric Identify source of I.R. or temperature change. Reposition or gas heaters, open flames, electric arcs, or any object unit so that source of problem is no longer in a zone. partially in a zone which can change temperature rapidly. B. Drafts are creating motion in drapes, display material or Locate source of motion. Eliminate same and walk-test overhead lighting fixtures. unit after motion source is eliminated. Trouble 2: UNlT GOES INTO ALARM INTERMITTENTLY OR CONTINUOUSLY FOR NO APPARENT REASON AND WALK-TEST LIGHT DOES NOT COME ON WHEN ALARM CONDITION EXISTS. DC voltage supply to detector from panel or power Check for proper DC voltage at terminals of detector. If supply inadequate or absent. PROPER POLARITY absent, check for proper voltage at panel or power supply MUST BE OBSERVED. (Note: If ORANGE jumper has terminals with wiring disconnected. If present, wiring to been cut, 12V DC must be supplied). detector is faulted. Check for open and shorted conditions in wiring. If proper DC voltage is absent, consult instructions for panel or power supply. Trouble 3: RELAY OPERATES NORMALLY BUT WALK-TEST LIGHT DOES NOT OPERATE. LED malfunction. Check for broken or shorted leads. Return unitfor service. Trouble 4: AREA OF COVERAGE CHANGES. A. Customer has repositioned furniture or equipment Caution customer that changes in layout can affect COVin premises. erage. Reposition the unit according to installation instruc- B. Mounting surface is unstable. A few degrees vertical tions. Be certain that unit has not been tampered with. Mount on secure surface. shift can change range substantially. Trouble 5: UNIT DOES NOT APPEAR TO BE OPERATING. Unit is not receiving power. Check for presence of 6V DC or (with ORANGE jumper cut) 12V. DC at terminals of unit. 579 588

GENERAL SPECIFICATIONS: Physical: Electrical : Width : Height: Depth: Voltage: Current: Standby: 3% ( 8.3 cm) 4% (10.8cm) 2 (51cm) 6V DC or 12V. DC, Filtered 35mA Power source used must be able to provide at least 4 hrs of standby power. The No. 495 Power Supply, which can be plugged directly into any 24 hour 12OV. AC outlet, can power a No. 1852 with 6V DC for over 12 hours in the event of AC failure. TO THE INSTALLER Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user is vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of frequent testing (at least annually) to insure the system s proper operation at all times. (62Ym) t 10' (3.0m) I I 60 No. 1852 Detector 1 * I (62?m) 30 (9.lm) Diagram 1: PROTECTION ZONES (No. 1852) 589 580

No. 1852 5 10 15 20 25 30 (lim) (3.0m) (4.6m) (6.lm) (7.6m) (9.lm) MAIN ZONE - DOWNWARD ZONE Diagram 2: RANGES AT 7 0 (2.1m) MOUNTING HEIGHT (No. 1852) 8 (2.4m) - 7 (2.lm)- 6 (1.8m)- MOUNTING HEIGHT ----------a ------a CAUTION: At mounting heights greater than 7 (2.1 mj, dead ------- -7?y (unprotected) spaces may result (particularly. between DOWNWARD 1 I I i zones and mounting surface). I i I I 1 i I I I 1 I I 1 10 I I 20 I I 30 (3.0m) (6.lm) (9.lm) RANGE (MAIN ZONE) EXAMPLE: MAXIMUM MAIN ZONE RANGE AT 7 0 (2.lm) MOUNTING HEIGHT IS 25 (7.6m) Diagram 3: MAXIMUM MAIN ZONE RANGES AT VARIOUS howwing HEIGHTS (No. 1852) 581 590

MOUNTING SURFACE OPTIONAL NO. 652MP MOUNTING PLATE HOUSING BASE (COVER REMOVED) HOOKS (4) SLOTS (4) / ENGAGE SLOTS ONTO HOOKS AND SLIDE HOUSING BASE DOWN FIRMLY SURFACE: '116" (0.8cm) MAX. DIAMETER. CENTER OF HOLE MUST BE ON LINE WITH BOTTOM EDGE OF PLATE. DETAIL A WIRE ENTRY AREA SEE DETAIL A. INSERT PLUG (PROVIDE IN HOUSING S WIRING ENTRY OPENING. ED) HOLDING PRONGS (2) SPREAD,.IF NECESSARY \ TO REMOVE ELECTRICAL KNOCKOUT FOR ASSEMBLY FROM UNIT SURFACE WIRING Diagram 4: MOUNTING DETAILS, USING OPTIONAL No. 652MP MOUNTING PLATE 591 582

CLOSED CIRCUIT PROTECTIVE LOOP FROM 6VDC OR (WITH ORANGE JUMPER CUT) 12VDC OTHER 30NTACTS. I. 6VDC I RATING: OR LED 1 A (MAX) 12V.DC AT 3OV DC, INPUT 12OV. AC /ORANGE JUMPER CUT FOR lpv.dc OPERATION No. 1852 Diagram 5: CONNECTIONS, TERMINALS AND JUMPERS (No. 1852) 583 592