180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged. The units have bottom air openings for separate supply and return ductwork. The units are available with accessory electric heat. The unit is intended for installation on an accessory roof curb (ordered separately). Horizontal supply and return connections are also possible with a factory -preassembled, high static regain, horizontal conversion adapter roof curb accessory (ordered separately). Bottom discharge on concentric applications requires a transition duct (field -supplied) external to the unit. All units meet AHRAE minimum efficiency tandard 90.1. tandard one -year product warranty. Five -year warranty on the compressor (180). One year warranty on the compressor (210, 240, 300). Units are rated in accordance with ARI standard 360. tandard unit is certified and listed by ETL and ETL, Canada. Low outdoor temperature cooling operation to 40_F (4_C) as standard. Dual freezestat protection is provided as standard. Dual scroll compressors with internal linebreak protection (300 has 3 compressors, circuit #1 has 2 compressors in tandem). Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless internally grooved copper tubes. Dual TXVs (thermostatic expansion valves) metering devices. Liquid line filter driers provided in each refrigeration circuit. Optional gear -driven EconoMi$er IV equipped with microprocessor controller that includes CO 2 ventilation control capability. FEATURE Manually adjustable outside air intake for up to 25% outside air. Automatic changeover (when used with an auto -changeover thermostat). ingle point electric connections. Disconnect in accordance with NEC must be field -supplied and installed. All units utilize 2 -stage cooling. Belt drive adjustable evaporator fan. Choice of low -medium or high -static indoor fan drive capability. Cabinet of galvanized steel, bonderized and finished with prepainted baked enamel. Cooling systems have low (loss -of -charge) and high -pressure switches. Two -inch disposable type return air filters are factory installed. Provision for alternate end return in base unit. Horizontal supply available by using accessory curb. EconoMi$er IV may be used with horizontal supply and return. Three direct -drive propeller condenser fans with vertical discharge (180 and 210). Two direct -drive propeller condenser fans with vertical discharge (240). ix direct -drive propeller condenser fans with vertical discharge (300).
UBMITTAL DATA Job Name Architect Engineer Contractor Unit Designation Unit Operating Weight lb Cooling Gross Total Capacity: Btuh at Condenser Air Temperature F Gross ensible Capacity: Btuh Compressor Power Input: kw Indoor Entering Air db F wb F Airflow External tatic Pressure in.wg Indoor Fan Motor ize Hp Exhaust Fan Motor ize Hp PERFORMANCE DATA Curb Weight lb Heating (Accessory Electric Heat) Heating Capacity: tage 1 Btuh tage 2 Btuh Heating Capacity Total Btuh ELECTRICAL DATA Power upply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection 2
FACTORY-INTALLED OPTION j Fully Integrated EconoMi$er IV, gear driven with Belimo Actuator (2-10vDC signal) and controller j EconoMi$er 2, gear driven with Belimo Actuator (4 - -20mA signal) and without controller intended for 3rd party control j Alternate High tatic Drive j Pre-Coated Condenser Coil Option j Low -medium static capability indoor fan drive j E -Coat Condenser Coil Options j Cu/Cu (tube/fin) condenser coils j Cu/Cu (tube/fin) condenser and evaporator coils j 115 -v Convenience Outlet - Factory Wired, Powered j moke Detector Installed in Return Air j Unit-Mounted Non -Fused Disconnect j Hinged Access Panels j tainless teel Condensate Pan j ervice Option Package (hinged access panels, non -fused disconnect, non -powered 115v convenience outlet) EXTENDED PROTECTION PLAN j Additional 5 -Year (6th -10th Year) Extended Protection Plan on the Heat Exchanger j Extended Parts Protection Plan (complete unit -2nd -5th year) j Extended Parts and Labor Protection Plan (complete unit - 2nd -5th year) j Extended Protection Plan on Compressor Parts (2nd -5th year) j Extended Protection Plan on Compressor Labor (2nd -5th year) OPTION AND ACCEORIE FIELD-INTALLED ACCEORIE j Fully Integrated EconoMi$er IV, gear driven with controller and Belimo Actuator (2-10v DC signal) j EconoMi$er 2, gear driven with Belimo Actuator (4-20mA signal) and without controller j Outdoor Air and Return Air Temperature ensors (differential dry bulb control) j Return Air Enthalpy ensor (single enthalpy control) j Outdoor and Return Air Enthalpy ensors (differential enthalpy control) j CO 2 ensor Duct Mount j CO 2 ensor Wall Mount j Winter tart Package j Roof Curb (14 -in.) j Roof Curb (24 -in.) j Roof Curb (Horizontal upply) j Factory Preassembled, Horizontal Conversion Adapter Roof Curb (180, 210 and 240 Only) j Power Exhaust j Barometric Relief j Thermostat and ubbase j Two -Position Damper Package j Motormasterr Control allows operations down to -20_F j Low Ambient Kit Down to 10_F (180, 210, 300) j Low Ambient Kit Down to 25_F (240) j Hail Guard (180, 210, 240) j Hydronic (Glycol) Coil j Electric Heat j Outdoor Air Thermostat j Time Guard II compressor anti-cycle protection 3
CERTIFIED DIMENION PRINT C07099 4
CERTIFIED DIMENION PRINT C07100 5
8 7-1/4 3.78 CERTIFIED DIMENION PRINT C07101 6
ROOF DIMENION PRINT 180-240 PKG NO. REF. CRRFCURB010A00 CRRFCURB011A00 CRRFCURB012A00 CRRFCURB013A00 CURB HEIGHT 1-2 (305) 2-0 (610) 2-0 (610) 2-0 (610) DECRIPTION tandard Curb 14 High tandard Curb for Units Requiring High Installation ide upply and Return Curb for High Installation Horizontal Adapter with High tatic Transition Duct NOTE: 1. Roof curb accessory is shipped disassembled. 2. Insulated panels: 1 thick neoprene coated 1 1 /2 lb density. 3. Dimensions in ( ) are in millimeters. 4. Direction of airflow. 5. Roof curb: 16 ga. (VA03-56) stl. 6. A 90 degree elbow must be installed on the supply ductwork below the unit discharge for units equipped with electric heaters. NOTE: To prevent the hazard of stagnant water build-up in the drain pan of the indoor section, unit can only be pitched as shown. DIMENION* (degrees and inches) in. UNIT ALL B C07097 7
ROOF CURB DIMENION PRINT 300 C07098 8
E2007 Bryant Heating & Cooling ystems 7310 W. Morris t. Indianapolis, IN 46231 Printed in U..A. Edition Date: 7/07 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No: UB---180---2 Replaces:UB.180.1 9