INSTALLATION AND USER MANUAL

Similar documents
INSTALLATION AND USER MANUAL

NEPTUNE Steam Room Installation Instructions

User manual Whirlpool

FREWIN STEAM SHOWER ENCLOSURE

900 Quadrant Steam Shower Cabin with 6 Body Jets

ARLEY STEAM SHOWER ENCLOSURE

Murano Shower Cabin Installation Instruction

LEVENS STEAM SHOWER ENCLOSURE

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Leben im Bad Living bathrooms. St.Trop

AQUAPEUTICS MONACO INSTALLATION MANUAL

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head

Installation and Operation Manual

MAJESTIC Steam Cabin Installation Instructions

Operating Instructions

E2 Series Installation

Contents. 1. Instructions for safety and use 20

Features Luxier SP26-GS

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

SYSTEM BASIC WHIRLPOOLS

REFLECTION STEAM CABIN INSTALLATION INSTRUCTIONS

800x1000x2180mm. FIJI Multifunction Shower Cabin K-1607A Reversible FIJI LEFT. Drainer can not in the shadow area! FIJI RIGHT

Instructions Manual SHC520X - SHC700X

Massage Bathtub. Instructions of installation and usage. Instructions of Installation and Use TLP-632. Cleaning&Maintenance

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Duke Manufacturing Co.

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Europa Shower Cabinet

SCHWAN INSTALLATION GUIDE

BATHROOM FURNITURE FITTING GUIDE

Installation & Operating Instructions

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

GETTING STARTED? EASY.

Package Content. Decor Star 1 2. PL-011-GS Rev. A

INSTRUCTION MANUAL USJ-101

Deluge Shower Mixing Valve 10045CP

Features Luxier SP21-SS

4L Instant Water Boiler Instructions for Use

Features Luxier SP21-SS

Telo Shower Mixing Valve TL10016CP

AUTOMATIC GRANULAR ICE FLAKER

ELLA SOAKING WALK IN BATHS OWNERS MANUAL. Representing these model numbers: L / R Elite Soaking L / R Royal Soaking

O W N E R S MANUAL ROUGE

Installation Manual for M-G014 & M-G015

Unity 180 Premium Whirlpool 180/80/62 cm

Decor Star 1. Decor Star PL-037-SS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC MODULAR ICE FLAKER

Instructions for use

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Inta City Shower Mixing Valve CT20010CP

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

GULFSTREAM PLASTICS LTD.

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

INSTALLATION INSTRUCTIONS

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

Warming Drawer LAM9001. User & Installation Guide

ELECTRIC WATER HEATER HT382E55

Tris. Ideal Standard 3

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

Bar Fridge USER MANUAL MB46W

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

1.6kW Window / Wall Air Conditioner

ascent Installation & maintenance instructions Customer/technical services Guarantee Mono basin filler with infrared sensor GUARANTEE REGISTRATION

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

MHE001 electric hob. Manual for Installation, Use and Maintenance

AUTOMATIC ICE-CUBE MAKER

Cordless Water Kettle LD-K3030A User Manual

Built-in Conventional oven

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

Enzo Concealed Shower Mixing Valve

Linear FIN EST SLO RUS UAE Lineare Design & Quality Engineering GROHE Germany

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Kiko Bath Shower Mixing Valve KK90015CP

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Plus Bath Shower Mixing Valve CP and PL30020CP

Eurosmart FIN EST SLO RUS UAE Eurosmart Design & Quality Engineering GROHE Germany

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid.

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

Waimea ShowerSpa MODEL #1034

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Puro Mini Dual Control Shower Mixer PU90010CP

INSTANTANEOUS ELECTRIC SHOWER

MIXED INDUCTION / HI-LIGHT VITROCERAMIC HOB MH-F3BS

HE6051FR Electric Hob Installation, Use and Maintenance

Features Decor Star PL-004-SS

INSTRUCTION MANUAL KETTLE

INSTALLATION INSTRUCTIONS

AXIAL FANS USER S MANUAL

TIMES SQUARE TWO-HANDLE THERMOSTAT

Features Decor Star PL-004-SS

CHH30 Dishwasher. Wiring Diagram. Spare Parts List. Installation / Operation

Heat Pump / Air Conditioner

Transcription:

INSTALLATION AND USER MANUAL HYDROMASSAGE CABIN SILVER DIAMOND LUX www.kerra.pl

INSTALLATION AND USER MANUAL HYDROMASSAGE CABIN SILVER DIAMOND LUX Thank you for purchasing our product. Please read this manual carefully before cabin installation. Diagrams and drawings in this manual are simplified and only contain details necessary for correct installation of the product. NOTE: Failure to comply with instructions in this manual may constitute basis to refuse to accept any complaints. Due to product specificity we recommend installation of the cabin by authorized installation service. Current list of authorized service points is available on our website www.novoterm.pl or at: 801 144 200 NOTE: If you decide to install the cabin yourself, we would like to advise that due to safety reasons plumbing and electrical installation of the device should be performed by a qualified plumber or licensed electrician. Those systems must be executed in compliance with applicable laws and regulations. Incorrect installation may cause cabin damage! BEFORE INSTALLATION MAKE SURE THAT: 1. The place where the cabin is to be installed has been prepared as shown on the drawing (fig. 1). 2. Water connection is ½ and together with the valves does not stick away from the wall further than 40 mm. 3. The drain hole is 50mm in diameter and is adapted to standard rubber reducers available on the market. The set does not include a reducer. 4. Water parameters in the system are within the limits set out as recommended. If water parameters exceed the recommended limits, use filtering/purification device ensuring appropriate parameters. 5. The plumbing system has been flushed and equipped with angle valves with mechanical water filters. 6. Static pressure in the water supply system does not exceed 4.5 bar. For safety reasons we recommend installation of pressure reducer regardless of the measurement results temporary pressure fluctuations are possible even if it is not shown by a measurement. 7. We recommend connecting the cabin to the municipal water mains, a water storage heater or heater with electronic temperature control. Do not connect the cabin to a hydraulic instantaneous water heater. For some functions such heater may not turn on or water may not reach the temperature desired. 8. Electricity connection or electrical socket are placed at the height preventing water access or ensuring that it is resistant to water ingress. The terminal box or socket must be at least IP45 water resistant. Cabins equipped with grounding cable must be permanently connected to the electrical system. Electrical system must be compliant with PN-EN-60335-1 standard. 9. The supply system is equipped with a 30 ma residual current circuit breaker with contact spacing minimum 3 mm. 10. The supply voltage is compliant with the parameters set out on the rating plate and protection is minimum 1A.

11. The room where the cabin is to be installed is equipped with working and efficient ventilation system. 12. The place of cabin installation has level surface at even level with the remaining part of the room, and level vertical walls. The cabin is not intended to be built in or placed in a niche. Compliance with the above requirements is necessary for correct installation and use of the cabin and ensuring subsequent free access. Fig. 1 electrical connection/ telephone connection 75 water connection min. 2250 1300 530 water drain 700 - space for the cabin - space that must remain free after the cabin installation TECHNICAL PARAMETERS Recommended hydraulic pressure: 2-4 bar Recommended hot water temperature: 55-65 C Recommended cold water temperature: 10-20 C Recommended water hardness: <15 n Ambient temperature: 15-30 C Supply voltage ~230 V, 50 Hz Maximum power: 30 W Dimensions of Silver Diamond Lux 90 cabin: 90 x 90 x 221 cm Dimensions of Silver Diamond Lux 100 cabin: 100 x 100 x 221 cm

TOOLS REQUIRED To make sure that cabin installation runs smoothly, please get the following tools ready: f 3 mm To install the cabin you will need hoses supplying cold and hot water from the water system to the cabin (not included in the set). Hose parameters should be as follows: ½ x ½, length of connection hoses should be selected according to individual needs. LIST OF COMPONENTS NOTE: Check if the set is complete immediately after purchase. Any missing or damaged parts should be immediately reported to the seller. A B C D E F G H I J K L M N O P Q R S T U V W X Y

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 symbol name qty symbol name qty A screw 4 x 40 4 M shelf 1 B large head screw 4 x 25 3 N shower hose connection 2 C small head screw 4 x 25 12 O drainage 1 D screw 4 x 20 12 P power supply 1 E screw 4 x 14 24 Q buffer 8 F countersunk head screw 4 x 12 12 R shower panel cover 2 G M12 nut 9 S panel support 1 H M12 flange nut 6 1 left side profile 1 I foot 4 2 U shape cross-section soft seal 2 J cover snap fastener 6 3 side glass 2 K cover cap 3 4 U shape cross-section rigid seal 2 L cover handle 3 5 left front profile 1

symbol name qty symbol name qty 6 left rear wall 1 14 door glass 2 7 top horizontal profile 1 15 magnetic seal 2 8 top cover 1 16 bottom horizontal profile 1 9 shower panel 1 17 shower tray 1 10 right rear wall 1 18 shower tray cover 1 11 right front profile 1 19 rod M12 x 14 cm 1 12 right side profile 1 20 shower tray frame 1 13 F shape cross-section seal 2 21 rod M12 x 46 cm 3 CONSUMABLE COMPONENTS symbol name qty symbol name qty T top roller 4 X massager 1 U bottom roller 4 Y dispenser 1 V door handle 2 A1 rain shower head* 1 W shower set 1 B1 halogen light* 1 * - elements pre-mounted in the top cover A1 B1 NOTES BEFORE INSTALLATION Glass elements of the cabin are made of safety glass. It is necessary to be particularly careful during unpacking, handling and installation of glass parts. The glass should not be put directly on the floor or leaned against walls. Do not hit them or lever with hard tools. Damaged glass will break into tiny pieces! Before finishing with silicone clean all surfaces of any dirt. We recommend waiting about 24 hours after the cabin installation for the silicone to bind. Openings for the drainage in the shower tray are standard size. If necessary, you may use different drainage set than the one provided in the set. NOTE: Check all components before installation. Do not install the cabin if you find that any of the components is damaged!

CABIN INSTALLATION 17 x 1 21 x 3 G x 3

20 x 1 A x 4

G x 2 H x 4 I x 2 L x 2 L I G H G x 2 I x 1 I G

19 x 1 G x 2 H x 2 I x 1 L x 1 L H I G 19 18 x 1

D x 12 J x 6 f 3 B x 3 K x 3 18 B 18 L f 3 K

O x 1 seal with Teflon tape Leave a gap of minimum 2 mm between the floor and the edge of the shower tray cover!! Resting the shower tray cover edge directly on the floor may cause it to crack!

1 x 1 7 x 1 12 x 1 16 x 1 C x 8 3 x 2 4 x 2 5 x 1 11 x 1

2 x 2 C x 4 F x 4! Be careful while drilling holes not to drill through the front part of the front profiles! f 3 F Ø 3 C

6 x 1 10 x 1 E x 8

9 x 1 R x 2 S x 1 silicon e silicone E x 8

E x 4 f 3 8 x 1 E x 4 f 3

14 x 2 T x 4 U x 4 V x 2 13 x 2 15 x 2

F x 8 Q x 8

At this stage fit the magnetic seals together if the installation was performed correctly, there should be no gap between them! Use a rubber mullet or a wooden batten to fit the seals. N x 2

W x 1 X x 1 M x 1 Y x 1

P x 1! All cables are marked with labels. Connect to each other only those cables which are marked with the same label.!

! Connecting hoses and drainage reducer are not provided in the set. Before finishing with silicone clean all surfaces!! After the cabin is finished with silicone we recommend waiting 24 hours for the adhesive to bind! After the silicone binds, check if the cabin is waterproof! Any leaks should be removed before it is positioned by the wall! silicone

Connect the cabin to the electrical system only after you have checked if it is waterproof! It must be connected by a licensed electrician.! It must be connected in compliance with currently binding standards. At this stage, the telephone line should be connected if you are going to use the telephone function.! 230 V CABIN USE MANUAL function selection FUNCTION CONTROLLER AND MIXER FUNCTION CONTROLLER Individual functions are selected by turning the knob of the function controller to the left or right. Functions are independent of each other and cannot be used simultaneously. water flow control MIXER Pulling the mixer handle up increases the water flow, pushing it down decreases the water flow. To increase the water temperature turn the handle left, to decrease it turn it right. temperature control The massage function in the cabin is provided by horizontal massage jets. They use narrow directional water jets at high pressure. The application of the massage function affects: - muscle relaxation - reduction of pain

top light indicator CONTROL PANEL telephone indicator fan indicator radio indicator FM MHz 88.4 panel switch light switch decorative light indicator frequency indicator fan switch radio/telephone switch volume control station search CONTROL PANEL USE 1. To turn on the control panel press button. 2. The fan is turned on and off with. button. Fan indicator on the display is lit when the fan is working. 3. To turn on and off the top light and decorative light use the button. The sequence of light control: top light; decorative light; top light and decorative light; light off. Light button on the display is lit when the light is working. 4. Turn the radio on using button. Radio indicator on the display is lit when the fan is working. To search for a radio station press TUN+ or TUN-. Use VOL+ and VOL- to regulate volume. To turn the radio off press button twice. 5. When the phone rings, press button to pick up. Appropriate indicator will lit up on the display, and radio will be automatically turned down. When you press the ended and telephone will be switched off. button again, the call will be NOTES CONCERNING SAFETY, USE AND CHARACTERISTICS OF THE CABIN 1. For safety reasons do not use in the cabin any electrical equipment which is not an integral part of the cabin. Such devices should be out of reach of any person using the cabin. 2. Do not leave any metal objects in the cabin. They may corrode. 3. It is recommended that you consult your doctor before using hydro massage. It is particularly recommended for people taking any medication, suffering from a heart condition, diabetes and pregnant women. 4. Unless your doctor advises otherwise, do not use the hydro massage for more than 15 minutes at

a time. 5. For safety reasons, children should use the cabin supervised by adults. 6. Any repairs should be performed by an authorised service. 7. The cabin is intended for household non-commercial use only. 8. Do not open or close the cabin doors abruptly. Do not lean on the glass or the panel. 9. Do not use the cabin under the influence of alcohol or drugs. 10. Do not allow the cabin to come into contact with water of the temperature over 65 C, open flame or glowing objects. 11. Even slightest contact with nail polish or hair spray is not allowed. 12. If the device is operated by children or any person with limited motor skills, limited sensory skills or with a mental disability, make sure that they are always supervised or had undergone appropriate training by person responsible for safety. Supervise children to make sure that they do not use the device for play! 13. Due to high sensitivity of microphone during use of telephone function, there might be acoustic feedback in the speaker installed in the cabin. Occurrence of feedback depends only on the room acoustics and quality of telephone signal. 14. If the cabin is not used for prolonged periods, disconnect it and close water valves. 15. Do not use the cabin if it is damaged. 16. Allowed load on the shower tray bottom is 100 kg/0.5m 2, however, no more than 150 kg for the whole surface of the bottom of the tray. The cabin may be used only by one person at a time. 17. Maximum evenly spread load of the cabin shelf is 1 kg. 18. Even after the water supply is shut off, water may still drop out of the rain shower head, shower head, jets or massager due to gravity. 19. Even if the cabin is level some water may remain on the bottom, the sides or the seat in the shower tray. This is a normal phenomenon caused by surface tension. 20. Tolerance of the glass dimensions: thickness: +0.3 mm; convexity: +1 mm; height/width: +3 mm. 21. Tolerance of other dimensions: for dimension 1000 mm - ±5 mm; for dimension >1000 mm - ±10 mm. 22. Life of consumables is 12 months. 23. Substitutes of other manufacturers are not recommended. Differences in parameters may have negative effect on the correct operation of the product. MAINTENANCE 1. After each use rinse the cabin thoroughly with clean water and wipe with soft damp cloth - prolonged contact of the cabin surface with personal care products may cause damage to the surface or corrosion of metal elements. Leave the cabin door open until it is completely dry and ensure proper ventilation of the room. The cloth used must not contain any abrasive or scratching fibres. 2. Clean the cabin surface with the use of mild detergents and soft cloth. We recommend using solution of liquid soap. After cleaning, rinse the cabin thoroughly with clean water and dry prolonged contact of the cabin surface with detergents may cause damage to the surface or corrosion of metal elements. Do not use aggressive agents containing caustic, irritant or abrasive substances. They may damage the cabin surface. The cloth used must not contain any abrasive or scratching fibres.

3. To remove residue of calcium or limescale use citric acid dissolved in water 1:5. Rinse the descaled surfaces thoroughly with clean water and dry. Prolonged contact of the cabin surface with descaling agent may cause damage to the surface or corrosion of metal elements. 4. In case of small scratches on the surface of the shower tray, sand wet damaged surface with sand paper (#2000), and then polish it with polishing paste and polishing equipment. 5. Inspect the condition of the consumable parts at least once a month and apply additional silicone grease on the rollers if needed. Replace any used up elements. 6. At least once a month descale the water jets in the shower head, jets on the shower panel, massager and rain shower head. Blockage of those elements may lead to damage or defect of elements of cabin hydraulic system. Replace any used up elements. 7. At least once a month inspect the condition of the water filter and if needed clean it or replace it. Dirty or damaged filter may cause decrease of water flow and in extreme cases also damage of the elements of the cabin hydraulic system. 8. If the product is used a lot, that is at least 30 hours per month, maintenance described in points 5-7 should be performed at least once every two weeks. Rev. 1.3 Date issued: 13/01/2015

Producer: NOVOTERM Sp. z o.o. ul. Zimowa 6, 70-807 Szczecin www.novoterm.pl