William P. Shuman, MD, FACR, FSCBTMR University of Washington Department of Radiology Seattle, WA

Similar documents
Phantom study of the impact of adaptive statistical iterative reconstruction (ASiR ) on image quality for paediatric computed tomography

GE Healthcare. Dash Variable-Acuity Monitoring

Efficiency at Hand. Digital Radiography GF50 Series CT-GF EN. Tube 300kHU (210kJ) 150kHU (105kJ)

AeroDR X30. Digital Mobile X-ray System

Build a premium DRF room like no other. Philips EasyDiagnost Eleva with DRF room solutions

It only takes an. instant to go DR. DR Retrofit: no limits to retrofitting your X-ray department with DR AED detectors

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Product Specifications

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

CARESTREAM DRX-Mobile Retrofit Kit

Advanced Electron Detector and Acquisition System

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Instrumentation for Beam Profiling in the Terahertz Regime

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

VISION V. affordable high performance

RAMAN SPECTROSCOPY See more, faster than ever before

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

Measuring Couch Motion Accuracy with X-ray Beam Fluence

OMNI TOUCH SCREEN PATIENT MONITOR

INTERNATIONAL STANDARD

Global Standard Quality : Healthcare is our Business

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Left Ventricular Assist Devices

BEDSIDE MONITORING Dash 3000/4000 V5

Standards Revisions Related to Life Safety Code Update

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Ultraview SL2400 With Wireless-LAN-Option

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Professional Design Project

UV measurements for medical applications using SiC photodiodes

Understanding total measurement uncertainty in power meters and detectors

CCTV, HOW DOES IT WORK?

Forward-scattered radiation from the compression paddle should be considered when average (or mean) glandular dose is estimated

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

GOLAY COMPLEMENTARY CODES, DOUBLE PULSE REPETITION FREQUENCY TRANSMISSION I. TROTS, A. NOWICKI, M. LEWANDOWSKI J. LITNIEWSKI, W.

Status Report about the TPC Detector and Module at CEPC

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

DRX Retrofit. Northern Cluster Business Partner Meeting 9th-11th September 2014 Castricum, Amsterdam

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1

OPERATING ROOM EQUIPMENT: GLOBAL MARKETS

Victoreen & 660-8

RaySafe Xi Classic. A complete system for X-ray measurements

Midtown Corridor Alternatives Analysis. Appendix A - Initially Considered Alternatives Screening

PULSE OXIMETER PACKAGE

SPECIFICATION FOR MULTIPARAMETER MONITOR

arxiv: v1 [physics.ins-det] 20 Mar 2017

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

BLACKSTAR ELECTROMAGNETIC MEASUREMENT WHILE DRILLING (MWD) TOOLS

The 2011 Global Congress on Travel Risk Management

The following report is prepared and published by:

Dosimetry issues related to the SSRT project at the ESRF

THE CLINICAL CONNECTION

Partial Load Performance Of Refrigeration System

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

Gear Tooth Profile Error caused by Hob Misalignment

Monitoring of Radiation Exposure Adjacent to a Linear Accelerator Treatment Bunker with a Highlight Window

INTERNATIONAL STANDARD

3kW 6kW, QUBE Fiber Lasers

CNAP MONITOR 500 HD QUICK GUIDE. This Quick Guide DOES NOT REPLACE the user manual!

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

Philips DXR Portfolio. Natalie Morgan DXR 27 th April 2015

Alarm and Measurement Default Settings

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

Intrusion sensors. We listened to you

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

Liver Kidney Wrap. Indications:

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Outdoor Detection. Intelligent perimeter surveillance solution range

Advance Warning Flasher System at High Speed

Montanez, Boutet, Fox, Van Campen, Hays, Woods

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

SPECTRAL INSTRUMENTATION

qube mini Overview

BlendingLine. MINICOLOR V MINICOLOR G GRAVICOLOR Dosing and mixing units. smart solutions

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Nanotechnology-Based Gas Sensors

Quick Reference Guide *

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

SLAG DETECTION SYSTEM CONTINUOUS THERMAL MONITORING

A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d

Omni (K) PATIENT MONITOR

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Chapter 22. Alternatives to the Proposed Project

SECTION L MONITORING EQUIPMENT

Freiburger Materialforschungszentrum SG Material Characterization & Detector Technology. Albert-Ludwigs-Universität Freiburg

Development of a variable output LED-365 irradiance standard

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

CERTIFYING 3D EXPERIENCES IN THE HOME

Review of options for cabin dosimetry & operation. Helen Amatiello & Colin Martin Health Physics Service Glasgow

Model S FT-IR SPECTROMETER

Transcription:

William P. Shuman, MD, FACR, FSCBTMR University of Washington Department of Radiology Seattle, WA

What is Wide-Detector Axial Step and Shoot? Our Institutional CT Experience : Revolution CT, GE Healthcare 16 cm wide-detector CT HD750 CT, GE Healthcare 4 cm detector CT

4 cm Detector Helical

What is Wide-Detector Axial Step and Shoot? Wide Detector: 16 cm slabs (z-axis coverage) without table movement during beam-on Step and Shoot: Contiguous serial 16 cm slabs Typical beam-on time per slab = 0.5 sec Movement time between slabs = 1.5 sec Scan duration for chest + abdomen + pelvis = 8.5 sec

Wide Detector Axial Step-and-Shoot Volume 1 Volume 2 Volume 3

Wide Detector Challenge: Cone Beam Cone beam diverges broadly in X-Y and Z directions Could cause issues in images: shading, cupping and ghosting artifacts, CT number shift

Wide Detector Challenge: Cone Beam Engineering to deal with these issues: Three dimensionally aligned modules in detector Post-patient collimator with 3D aligned holes Specialized reconstruction algorithm Addresses heel effect and spectral artifacts Multi-material artifact reduction Hybrid iterative reconstruction

Wide Detector: 3D Focally aligned modules

Wide Detector

Advantages of Wide Detector Axial Scanning Decreased acquisition time Shorter breath hold, fewer motion artifacts Less iodinated contrast needed No helical artifacts Windmill, streaking, volume averaging Less image noise per given radiation dose Lower dose scanning for given IQ

16 cm Detector - Axial

Common CT Artifacts Noise Beam Hardening and Scatter Metal Out of field Windmill (helical) Cone Beam

Noise CTDI vol 7.89 DLP 523.09 CTDI vol 7.79 DLP 501.21 4 cm Detector - Helical 16 cm Detector - Axial

Beam Hardening and Streak 4 cm Detector - Helical 16 cm Detector - Axial

Metal 4 cm Detector - Helical 16 cm Detector - Axial

Out of Field 4 cm Detector - Helical 16 cm Detector - Axial

Out of Field 4 cm Detector - Helical 16 cm Detector - Axial

Windmill 4 cm Detector - Helical 16 cm Detector - Axial

Aligning tissue planes between slabs Recon Mode Plus Stitch program Aligns tissue planes on coronal and sagittal recons. Limitations: big breath or large amount of body motion

16 cm Detector - Axial

4 cm Detector - Helical 16 cm Detector - Axial

Advantages of Wide Detector Axial Scanning Whole organ scanning without table motion Most impactful in cardiac Liver, pancreas, kidneys, transplants, brain Perfusion

One Beat Cardiac

One Beat Cardiac 4 cm Detector - Helical 16 cm Detector - Axial

One Beat Cardiac CTDI vol 16.33 DLP 343.03 CTDI vol 15.05 DLP 240.77 4 cm Detector - Helical 16 cm Detector - Axial

Brain Perfusion Time To Peak Mean Transit Time

Disadvantages of Wide Detector Axial Scanning Step off during cardiac gated scanning If irregular rhythm Only when scanning whole-chest (2 slabs) Solution: place slab interface away from coronary arteries Variable smart slab thickness

ECG Gating Step Artifact: Irregular rhythm 16 cm Detector Axial

Disadvantages of Wide Detector Axial Scanning Potential for skipped tissue : if patient exhales during table motion between slabs Exhale versus inhale Coaching of patient by techs is important

Patient Exhaled

Wide Detector Step-and-Shoot: The Ultimate Challenge - TAVR 5 slabs (2 in chest, 3 in abdomen/pelvis) Needs precise contrast timing over entire aorta Chest is ECG gated, Abdomen/pelvis is not

Our Experience with TAVR 4 cm Detector Protocol Separate acquisitions of the chest (helical ECG gated chest) and of the abdomen/pelvis (helical non-gated) 2 separate contrast injections 16 cm Wide-Detector Protocol One acquisition axial scanning of ECG gated chest and non-gated abdomen-pelvis One contrast injection

Methods Patients Identified 36 consecutive patients scanned for TAVR planning on 16 cm wide-detector CT Carefully matched for gender, age, PA/Lat scout measurements, and BMI to 36 patients previously scanned for TAVR planning on 4 cm detector CT

Methods Subjective Image Evaluation: 2 independent reviewers scored each of the 4 series in the 72 image sets Overall aortic enhancement Overall image quality for non-vascular Image quality of aortic annulus

Methods Objective Measurements: Vascular attenuation at 8 locations - aorta and iliofemorals Psoas HU and image noise in air Calculated SNR, CNR

Results Scan Times Protocol 1 (n=36) Protocol 2 (n=36) p value Chest Scan Time (sec) 2.7 ± 0.05 12.4 ± 2.3 <0.001 Abdomen/Pelvis Scan Time (sec) 7.7 ± 1.5 5.2 ± 1.2 <0.001 EGC Gating Transition Time (sec) 5 30 Mean Total Acquisition Time (sec) 15.4 47.6 Data are means ± SD Wide detector acquisition time ave. 32 seconds less than 4 cm detector

Results Radiation Dose Protocol 1 (n=36) Protocol 2 (n=36) p value Chest Scan Range (mm) 278 ± 26 287 ± 32 0.2 CTDI vol (mgy) 36 ± 13 68 ± 14 <0.001 SSDE (mgy) 44 ± 13 82 ± 19 <0.001 Abdomen/Pelvis Scan Range (mm) 406 ± 36 420 ± 33 0.08 CTDI vol (mgy) 15 ± 5 21 ± 7 <0.001 SSDE (mgy) 18 ± 5 25 ± 10 <0.001 Total Exam DLP (mgy-cm) 1536 ± 570 3244 ± 754 <0.001 Wide detector exam DLP ave. 53 % less than 4 cm detector

Results Subjective Evaluation Vascular Enhancement Scores Protocol 1 (n=36) Protocol 2 (n=36) p value Chest 3.92 3.90 0.61 Abdomen/Pelvis 3.86 3.83 0.68 Overall Image Quality Scores Chest 3.57 3.49 0.36 Abdomen/Pelvis 3.44 3.50 0.71 Aortic Annulus Series 3.26 2.97 0.02

Results Iodine Dose Protocol 1 (n=36) Protocol 2 (n=36) p value Contrast Volume (ml) 91 ± 22 136 ± 21 <0.001 Iodine Dose (g) 32 ± 8 48 ± 7 <0.001 Wide detector iodine dose ave. 33% less iodine than 4 cm detector

Results Quantitative Evaluation Protocol 1 (n=36) Protocol 2 (n=36) p value Image Noise (HU) 7.3 ± 2 6.7 ± 2 0.27 Vascular Attenuation (HU) 358 ± 86 300 ± 51 <0.001 SNR 53 ± 20 49 ± 19 0.41 CNR 45 ± 19 41 ± 16 0.32 Wide detector vasc. attenuation ave. 20% greater than 4 cm detector

Mean HU Attenuation at 8 Vascular Locations

Conclusion: For TAVR Planning CT Compared to 4 cm detector, wide detector axial step-andshoot resulted in: Greater vascular attenuation Similar subjective/objective image quality parameters 53% lower DLP 33% less iodine

Wide Detector Axial Publications: Faster acquisition times Less radiation dose Lower noise Less contrast required Fewer artifacts 1. Kroft LJ, Roelofs JJ, Geleijns J. Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions. Pediatr Radiol. 2010;40:294-300. 2. Podberesky DJ, Angel E, Yoshizumi TT, et al. Comparison of radiation dose estimates and scan performance in pediatric high-resolution thoracic CT for volumetric 320-detector row, helical 64-detector row, and noncontiguous axial scan acquisitions. Acad Radiol. 2013;20:1152-1161. 3. Ryu YJ, Kim WS, Choi YH, et al. Pediatric Chest CT: Wide-Volume and Helical Scan Modes in 320-MDCT. AJR Am J Roentgenol. 2015;205:1315-1321.