HomeWorks QS Palladiom HVAC Solution

Similar documents
P/N f. HomeWorks QS Palladiom Thermostat Configuration Guide

HomeWorks QS Architectural RF GRAFIK T Local Controls

GRAFIK T Controls GRAFIK T

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

Maestro Dimmer - Satin Finish, Incandescent/Halogen, Single-Pole, Clamshell Packaging, 120V/600W In Biscuit

Maestro Occupancy sensing switch

Maestro Occupancy sensing switch

Maestro Dual-Circuit Occupancy Sensing Switch

Lutron C L dimmers. Solve the challenges of light bulb compatibility. Works with:

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

Commercial Energy Solutions Suggested List Pricing. October 1, 2009 Euro

LED Control Solutions. Smooth, flicker-free dimming for every application

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Maestro Occupancy Sensing Switch

Maestro Occupancy Sensing Switch

Lutron C L dimmers. Solve the challenges of light bulb compatibility COMING SOON. Nova T* C L. Works with:

Duct and Rough Service Carbon Monoxide Sensor

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Room thermostats with LCD for wall mounting

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Maestro Occupancy Sensor C L Dimmer

SPECIFICATION SUBMITTAL

TEC210x-2 Series Networked Thermostats

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Analog Room Pressure Monitor RPC Series

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Net/X US32 Universal Setback Communicating Thermostat

LCF Touch Modbus Datasheet Application Security Advice Caution

EL-TSTAT-8820 Safety & Installation Instructions

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

User s Manual

Instruction FH-CWP Thermostat

TEC2100 Series Networked Thermostats

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Schneider Electric Erie T155 Series

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Vive PowPak Fixture Controls

2800 Series Control Units

Table 1. Serie of Digital Room Thermostats.

Instruction Manual August sitrans CU 02

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

Predator Controller Hardware Family

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Flush-mounted room thermostat

Lutron Wireless. Adjust your lights, shades, and temperature from anywhere. Motorized shade. Remote control

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

B-40/B-41 Modulating Temperature Controller

Installation Instructions

Daikin ENVi Thermostat installation overview

Semi flush-mount room thermostat

Installation Instructions

Installation and Maintenance Manual IM

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

PRELIMINARY EDITION

TEC1100 Series Thermostats

A complete drapery track offering to meet all of your application needs

Carbon Monoxide Transmitter

centralised lighting control LCP128TM systems

Across-the-Line SERIES MP300 Combined Manual and Automatic

centralised lighting control LCP128TM systems

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Wall-mounted room thermostat with LCD

SYST0101CW Product Specifications

T-32-TS Touchscreen Thermostat. Installation Manual

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

Oxygen (O2) Single-Point Gas Detection System

Combustible Gas Detection and Control System

Installation Manual. Zoning Kit

LCF Touch (from firmware version 1.7)

HEAT HEAT HEAT COOL COOL

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

LC1350 Level Controller

Thermostats. Thermostats

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Safety & Installation Instructions

Save Energy with Unparalleled Total Home Control

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Hydronic & HVAC Control Systems

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Room thermostat with Auto Timer, Option External Input

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Transcription:

Add a Palladiom HVAC solution to a HomeWorks QS system for convenient and aesthetically pleasing control of temperature and for intuitive heating and cooling adjustments. HomeWorks QS Palladiom Thermostat Features Heat Set On HomeWorks QS Palladiom Thermostat Aesthetically coordinates with Palladiom keypads. Available in plastic, glass and metal finishes. See Colors and Finishes at the end of the document for more information. Backlit screen and buttons that include Dynamic Backlight Management (DBM to automatically adjust backlight intensity based on ambient lighting conditions. Displays temperature in Fahrenheit or Celsius. Uses Lutron QS link for power and communication with other QS devices. Ships with a sealed wallbox for use in new or existing constructions, specifically for hollow walls that may have air movement in the wall cavity. IEC SELV / PELV NECR Class 2 for 24 30 V- IEC ELV / NECR Class 2 for 31 3 V- IEC, culus, and NOM compliant. HomeWorks QS Palladiom HVAC Controller Works with many residential HVAC systems. Uses / 24 V- and common wiring from HVAC equipment or other / 24 V- IEC PELV/NECR Class 2 supply. Supports an optional wired remote temperature sensor to allow for flexibility regarding thermostat installation location. The wired remote temperature sensor is used instead of the internal thermostat sensor. IEC and culus compliant. System System features programmed in HomeWorks QS software. -day programmable schedule. Schedule events based on time of day or astronomic time. Local hold button disables system timeclock events. Select alternate setpoints to save energy while on vacation. Local fail safe feature continues operation if communication with the HomeWorks QS system is interrupted. Monitor and control thermostat settings via Lutron Connect mobile device. Auto HomeWorks QS Palladiom HVAC Controller HVAC Equipment www.lutron.com/support 1

Model Numbers HQWT-T-HW-XXX*-A HomeWorks QS Palladiom thermostat SMC-RESI HomeWorks QS Palladiom HVAC controller (includes wire harness LR-HVAC-WIRE-0 LR-TEMP-FLSH Wired flush mount sensor (optional remote temperature sensor * XXX in the model number represents color / finish code. See Colors and Finishes section at the end of the document for more information. Compatibility The HomeWorks QS Palladiom HVAC controller works with residential HVAC systems including: Conventional forced air systems using gas, electric, or oil heat, as well as compressor-based cooling-only as split systems or packaged units. Fan coil units Hydronic or electric underfloor / radiant heating (see Underfloor Heating Systems on page 3 Specific VRV / VRF systems (see VRV / VRF Systems on page 3 Typical System Configurations Control wiring is done via conventional isolated relays for stage capacity control. Typical system configurations are: Heat / Cool Stages (Relays 1 heat / 1 cool conventional (W1, Y1, G 1 heat conventional (with or without fan [G] (W1 1 cool conventional (Y1, G Fan Coil Units 2-pipe, On / Off valve, 3-speed fan with changeover sensor (valve, G1,G2,G3 2-pipe, On / Off valve, 0 V controlled fan with changeover sensor (valve, 0 V fan 2-pipe, 0 V valve, 3-speed fan with changeover sensor (0 V valve, G1, G2, G3 2-pipe, 0 V valve, 0 V controlled fan with changeover sensor (0 V valve, 0 V fan 4-pipe, On / Off valve, 3-speed fan (hot valve, cold valve, G1, G2, G3 4-pipe, On / Off valve, 0 V controlled fan (hot valve, cold valve, 0 V fan 4-pipe, 0 V valve, 3-speed fan (0 V hot valve, 0 V cold valve, G1, G2, G3 4-pipe, 0 V valve, 0 V controlled fan (0 V hot valve, 0 V cold valve, 0 V fan www.lutron.com/support 2

VRV/VRF Systems The HomeWorks QS Palladiom thermostat can be used to control the VRV / VRF systems listed below. MitsubishiR VRF Systems Requires one of these hardware options: HomeWorks QS Palladiom thermostat with HomeWorks QS processor and CoolAutomationT interface.* See Application Note #0 (040 at www.lutron.com HomeWorks QS Palladiom thermostat with HomeWorks QS Palladiom HVAC controller and MitsubishiR thermostat controller interface.* See Application Note # (04 at www.lutron.com LGR VRF Systems Requires one of these hardware options: HomeWorks QS Palladiom thermostat with HomeWorks QS processor and CoolAutomationT interface.* See Application Note #0 (040 at www.lutron.com HomeWorks QS Palladiom thermostat with HomeWorks QS Palladiom HVAC controller and LGR thermostat controller interface.* See Application Note #2 (042 at www.lutron.com DaikinR VRV Systems Requires: HomeWorks QS Palladiom thermostat with HomeWorks QS processor and CoolAutomationT interface.* See Application Note #0 (040 at www.lutron.com Underfloor Heating Systems Requires: HomeWorks QS Palladiom thermostat with HomeWorks QS processor and Heatmiser interface.* See Heatmiser HVAC Integration with HomeWorks QS document. * Provided by others. www.lutron.com/support 3

Heat Auto Set On HomeWorks QS Palladiom HVAC Solution System Diagram Wireless router (by others Lutron Connect Bridge HomeWorks QS Palladiom thermostat Palladiom keypad Ethernet connection HomeWorks QS processor HVAC equipment (by others QS link 1 HomeWorks QS Palladiom HVAC controller link 2 Lutron Connect mobile device application HomeWorks QS Palladiom HVAC controller 3, 4 HomeWorks QS Palladiom HVAC controller signals 1 For wiring details, see QS Link section on page. 2 For wiring details, see HomeWorks QS Palladiom HVAC Controller Link section on page 13. 3 For more information when using a HomeWorks QS Palladiom HVAC controller and a 3 rd party interface in VRV / VRF systems, refer to either Application Note # (04 or Application Note #2 (042 at www.lutron.com 4 For more information when using a CoolAutomationT interface in VRV / VRF systems, see Application Note #0 (040 at www.lutron.com www.lutron.com/support 4

Technical Specifications HomeWorks QS Palladiom Thermostat Model Number HQWT-T-HW-XXX*-A Regulatory Approvals Operating Voltage IEC, culus, and NOM compliant. Typical Power Consumption ma at 24 V- Maximum Power Consumption 24 30 V- IEC SELV / PELV / NECR Class 2 31 3 V- IEC ELV / NECR Class 2 Power provided by QS link power supply. 0 ma at 24 V- Test conditions: Backlight on full. 3 Power Draw Units (PDUs. For more information, see Power Draw Units on the QS Link (P/N 340. Environment Communications Room Temperature Sensor Power Failure Memory Mounting Wiring Warranty Ambient operating temperature: 32 F to 4 F (0 C to 40 C % to 0% relative humidity (non-condensing. Indoor use only. IP20 Rating Thermostat communicates with the HomeWorks QS system via 4-wire QS link protocol. It also communicates with the HomeWorks QS Palladiom HVAC controller via 3-wire HomeWorks QS Palladiom HVAC controller link. Temperature display range: 32 F to F (0 C to 3 C Temperature setpoint range: 0 F to 0 F ( C to 32 C (programmable Accuracy: At 0 F: < +/ 1 F At 2 C: < +/ 0. C Should power be interrupted, the thermostat will retain all settings when power is restored. Mount on a clean, dry, interior wall approximately 4 ft to ft (1.2 m to 1. m above the floor. See Mounting section for more information. IEC SELV / PELV / NECR Class 2: 24 30 V- IEC ELV / NECR Class 2: 31 3 V- 22 AWG (0. mm 2 and 1 AWG (0. mm 2 solid wiring. www.lutron.com/technicaldocumentlibrary/warranty.pdf www.lutron.com/technicaldocumentlibrary/intl_warranty.pdf Warranty only valid if installed by a properly trained climate control specialist. * XXX in the model number represents color / finish code. See Colors and Finishes section at the end of the document for more information. www.lutron.com/support

Technical Specifications (continued HomeWorks QS Palladiom HVAC Controller Model Number Regulatory Approvals Operating Voltage Maximum Relay Rating Maximum Power Consumption Environment Communications Power Failure Memory Mounting Wiring Warranty SMC-RESI IEC and culus compliant. 0 / 0 Hz +/ % 24 V- +/ % 2 A resistive load at 240 V~ or 30 V- Note: If fan or valves exceed these ratings, interposing relays must be used between the HomeWorks QS Palladiom HVAC controller and the HVAC unit. Note: Do not connect directly to inductive or capacitive loads. For more information, refer to the installation instructions. 4 W / VA Ambient operating temperature: 4 F to 131 F ( 20 C to C % to 0% relative humidity (non-condensing. Indoor use only. IP20 Rating HomeWorks QS Palladiom HVAC controller communicates with the HomeWorks QS Palladiom thermostat using a 3-wire Modbus protocol. Should power be interrupted, the HomeWorks QS Palladiom HVAC controller will retain system configuration settings when power is restored. Intended for DIN rail mounting in an enclosure. See Mounting section for more information. HomeWorks QS Palladiom HVAC Controller: LR-HVAC-WIRE-0 required wire harness (included. For relay outputs, use wires at least 20 AWG (0. mm 2 with a temperature rating of at least 1 F (0 C. Wired Flush Mount Sensor: IEC SELV / PELV / NECR Class 2; 22 AWG (0. mm 2 twisted, shielded pair wiring. Maximum wire length is 0 ft (30. m. www.lutron.com/technicaldocumentlibrary/warranty.pdf www.lutron.com/technicaldocumentlibrary/intl_warranty.pdf Warranty only valid if installed by a properly trained climate control specialist. www.lutron.com/support

Dimensions All dimensions shown as: in (mm HomeWorks QS Palladiom Thermostat Front View 4.0 (2 Side View 1.1 (2 0. (14 3. (4 2. ( 0.4 ( 0. (1 0. (14 Rear View 2. ( 2. ( 2.3 (0 Continued on the next page... www.lutron.com/support

Dimensions (continued All dimensions shown as: in (mm Wallboxes and Wallbox Adapters Sealed Wallbox (WBOX-HPT-Q1 and Corresponding Wallbox Adapter (included Both the sealed wallbox and corresponding wallbox adapter are included with the thermostat for use with hollow walls that may have air movement in the wall cavity. Rear View Front View Side View Wallbox Adapter 2. (0 2.0 (1 2. (0 Wiring gaskets 1. (4 EBB-1-SQ (sold separately and Corresponding Wallbox Adapter (included Square, metal wallbox (sold separately for use with solid masonry or poured concrete walls with no airflow. Corresponding wallbox adapter included with the thermostat. Front View Wallbox 2. (0 Front View Adapter 2.3 (0 Side View Minimum 1.3 (3 Wallbox 2.3 (0 3.4 ( www.lutron.com/support Conduit connector Maximum 0. (3

Dimensions (continued All dimensions shown as: in (mm HomeWorks QS Palladiom HVAC Controller Front View Side View 3.4 ( 0.2 ( 2. (0 2.4 (2 www.lutron.com/support

Mounting HomeWorks QS Palladiom Thermostat Mount on a clean, dry, interior wall. Mount approximately 4 ft to ft (1.2 m to 1. m above the floor. Mount on a wall without pipes, chimneys, or ducts. Mount on a wall with good visibility and control access. Do not mount on an exterior wall, close to a window, next to a door, or areas with drafts. Do not mount in direct airflow from supply and return registers / grilles. Do not expose to water (e.g., drips or splashes or mount in a damp area. Do not mount within 4 ft (1.2 m of heating sources (e.g., direct sunlight, light bulbs, etc.. Do not mount in areas with poor circulation (e.g., niches, alcoves, behind curtains, or behind doors. Do not mount within 0. in (1 mm of Palladiom keypads. Note: If it is not possible to follow these guidelines, the use of an indoor remote temperature sensor is recommended. For more information, see Remote Temperature Sensor section on page 24. Inside Wall Outside Wall 4 ft to ft (1.2 m to 1. m Continued on the next page... www.lutron.com/support

Mounting (continued HomeWorks QS Palladiom HVAC Controller The HomeWorks QS Palladiom HVAC controller is intended for DIN rail mounting and requires a 4 DIN wide mounting location. For DIN rail installation, follow the steps below: 1 2 3 Minimum Clearances The HomeWorks QS Palladiom HVAC controller has been designed as an IP20 product and must be installed in an enclosure (by others with the clearances shown below. All dimensions shown as: in (mm 0. (20 0. (20 3.2 (0 1. (40 0. (20 1. (40 0. (20 Note: Multiple HomeWorks QS Palladiom HVAC controllers can be mounted next to each other. www.lutron.com/support 11

Wiring QS Link Use IEC SELV / PELV / NECR Class 2 (24 30 V- or IEC ELV / NECR Class 2 (31 3 V- wiring to connect the thermostat to the QS link for power and communication. Connect two 22 AWG (0. mm 2 shielded, twisted pair wires to terminals 3 and 4. Shielding (drain of the twisted pair wires must be connected together as shown, but do not connect the shielding to earth / ground or the thermostat and do not allow it to contact the grounded wallbox. Connect the appropriate size wires to terminals 1 and 2 for power, according to your link length (see table below. Connect Drain / Shield as shown. Do not connect to Ground (Earth or the thermostat. Connect the bare drain wires and cut off the outside shield. Note: Use appropriate wire connecting devices as specified by local codes. Link Wiring < 00 ft (13 m Rear View IEC ELV / NECR Class 2 or IEC PELV / SELV NECR Class 2 One or two 1 AWG (1.0 mm 2 1: (Black 2: V+ (Red 1 1 2 2 3 3 4 4 Drain / Shield HomeWorks QS Palladiom HVAC controller link Data link One twisted, shielded pair 22 AWG (0. mm 2 Link Wiring 00 ft to 2000 ft (13 m to m 3: MUX (Purple 4: _ (White QS Link Wire Sizes (check compatibility in your area IEC ELV / NECR Class 2 or IEC PELV / SELV NECR Class 2 One 1 AWG (1.0 mm 2 1: (Black 2: V+ (Red One or two AWG (2. mm 2 Drain / shield Data link One twisted, shielded pair 22 AWG (0. mm 2 3: MUX (Purple 4: _ (White QS Link Wiring Length Wire Gauge Lutron Cable Part Number < 00 ft (13 m 00 ft to 2000 ft (13 m to m Power (terminals 1 and 2 1 pair 1 AWG (1.0 mm 2 GRX-CBL-34S (non-plenum GRX-PCBL-34S (plenum Data (terminals 3 and 4 1 twisted, shielded pair 22 AWG (0. mm 2 Power (terminals 1 and 2 1 pair AWG (4.0 mm 2 This will not fit in terminal. Connect as shown above. Data (terminals 3 and 4 1 twisted, shielded pair 22 AWG (0. mm 2 GRX-CBL-4L (non-plenum GRX-PCBL-4L (plenum Continued on the next page... www.lutron.com/support

Wiring (continued HomeWorks QS Palladiom HVAC controller link The HomeWorks QS Palladiom HVAC controller comes with a 3-wire harness in the LR-HVAC-WIRE-0 package. This is to be used on the HomeWorks QS Palladiom HVAC controller link to the thermostat. The 3-wire harness can be extended using one 1 AWG (1.0 mm 2 or AWG (4.0 mm 2 wire and 1 pair 22 AWG (0. mm 2 twisted, shielded wire. See table below and diagrams to right. Do not connect the drain / shield wire to earth / ground or to the thermostat and do not allow it to contact the grounded wallbox Link Wiring < 00 ft (13 m QS link Rear View Data link One twisted, shielded pair 22 AWG (0. mm 2 : _ (Black +: MUX (White Drain / shield 1 2 3 IEC ELV / NECR Class 2 or IEC PELV / SELV NECR Class 2 One 1 AWG (1.0 mm 2 G: (Gray HomeWorks QS Palladiom HVAC Controller Link Wire Sizes (check compatibility in your area HomeWorks QS Palladiom HVAC Controller Link Wiring Length < 00 ft (13 m Wire Gauge Power (COM [G] One 1 AWG (1.0 mm 2 Data (MUX and _ One twisted, shielded pair 22 AWG (0. mm 2 Lutron Cable Part Number GRX-CBL-34S (non-plenum GRX-PCBL-34S (plenum www.lutron.com/support 13

Wiring (continued HomeWorks QS Palladiom HVAC controller link (continued HomeWorks QS processor 1 2 3 4 V+ MUX _ HomeWorks QS Palladiom thermostat Gray (G Com White (+ MUX Black ( _ QS Link Power and communication # # # # # # #11 # Relay Terminals SPST(NO 2 A 240 V~ maximum relays Terminal Conventional Fan Coil Unit # Heat stage 1 (W 1 Hot valve (H VALVE # # Heating stage 1 (R H Cooling / compressor (R C Heat valve (R H or Valve (R Fan (R FAN # Compressor stage 1 (Y 1 Fan high (G 3 # Compressor stage 2 (Y 2 Fan medium (G 2 # Fan (G Fan low (G 1 #11 Heat stage 2 (W 2 Cold valve (C VALVE HomeWorks QS Palladiom HVAC controller # Heating stage 2 (R H2 Cold valve (R C White (heat Black (common Green (fan Yellow (cool Not used Wire harness for 0 V- valves and fan controls Controller Power (from HVAC system s IEC / SELV / PELV / NECR Class 2 Red (R H Heat Gray /Red (C Black Isolated common (for changeover sensor, remote Black temperature sensor, etc. Blue / Red (changeover sensor Blue (remote temperature sensor Optional signal wires Note: Wire harnesses can be extended using 1 AWG or 22 AWG (1.0 mm 2 or 0. mm 2 wire. Use twisted pair, shielded cables to extend analog I / O and HomeWorks QS Palladiom HVAC controller links. See previous page. Note: All terminal blocks are removable. Continued on the next page... www.lutron.com/support 14

Wiring (continued Signal Wiring Guide Terminal W 1 H VALVE Description 1 st stage heat relay Hot valve for 4-pipe fan coil units R H Heating power Connect to secondary side of heating system 1 R Valve R C Cooling / compressor power Connect to secondary side of cooling system 2 R FAN Y 1 Fan 1 st stage compressor relay G (G 3, G, G Fan relay (fan high, fan medium, and fan low for fan coil units 2 1 Cold valve for 4-pipe fan coil units C VALVE Valve C Single valve control for 2-pipe fan coil units Required common wire from secondary side of 1 Heat stage 1 for conventional systems. 2 Compressor and fan. Cable Type Wire Size AWG 24 to 14 22 to 14 mm 2 0.2 to 2. 0.2 to 2. 2 x 24 to 1 2 x 0.2 to 1.0 2 x 24 to 1 2 x 0.2 to 1. 2 x 22 to 1 2 x 0.2 to 1.0 2 x 20 to 1 2 x 0. to 1. 0.2 in ( mm 4.4 to.3 in-lb (0. to 0. N m ø 0.14 in (4 mm www.lutron.com/support 1

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Conventional Systems Diagram 1: 1 heat stage / 1 cool stage system (1 W R H R C Y 1 Y 2 G W 2 R W2 11 Heat 1 Compressor Fan L1 (hot R H C Diagram 2: 1 heat stage / 1 cool stage system (2 s W R H R C Y 1 Y 2 G W 2 R W2 11 Heat 1 Compressor Fan ** (for fan / compressor Cooling L1 (hot L1 (hot R H (for heat Heating C * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the HomeWorks QS Palladiom HVAC controller. ** In a two system it is not necessary to connect the compressor common wires. Continued on the next page... www.lutron.com/support 1

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Conventional Systems (continued Diagram 3: Heat only system with no fan W R H R C Y 1 Y 2 G W 2 R W2 11 Heat 1 L1 (hot R H C Diagram 4: Heat only system with fan W R H R C Y 1 Y 2 G W 2 R W2 11 Heat 1 Fan L1 (hot R H C * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the HomeWorks QS Palladiom HVAC controller. Continued on the next page... www.lutron.com/support 1

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Conventional Systems (continued Diagram : Cool only system W R H R C Y 1 Y 2 G W 2 R W2 11 Compressor Fan L1 (hot R C * If a secondary is available to power the auxiliary heat, connect the auxiliary to pin (R W2. ** If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the HomeWorks QS Palladiom HVAC controller. Continued on the next page... www.lutron.com/support 1

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Fan Coil Units 2-pipe Systems Diagram : 2-pipe system, On / off valve, 3-speed fan, changeover sensor Valve R R FAN G 3 G 2 G 1 11 Valve Fan high Fan medium Fan low L1 (hot (R H Changeover sensor Diagram : 2-pipe system, On / off valve, 0 V controlled fan, changeover sensor Valve R R FAN G 3 G 2 G 1 11 Valve L1 (hot (R H 0 V-** Fan Changeover sensor * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the Palladiom HVAC controller. ** When using 0 V- fan or valve control, a different power supply must be used to power the Palladiom HVAC controller and the 0 V- fan/valve actuators. For more information, see Application Note #1 (041 at www.lutron.com Semitec 3AT or equivalent NTC k at 2 C Continued on the next page... www.lutron.com/support 1

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Fan Coil Units (continued 2-pipe Systems (continued Diagram : 2-pipe system, 0 V valve, 3-speed fan, changeover sensor Valve R R FAN G 3 G 2 G 1 11 Fan high Fan medium Fan low L1 (hot (R H 0 V-** Valve Changeover sensor Diagram : 2-pipe system, 0 V valve, 0 V controlled fan, changeover sensor Valve R R FAN G 3 G 2 G 1 11 No relay output used. L1 (hot (R H 0 V-** Valve Fan Changeover sensor * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the Palladiom HVAC controller. ** When using 0 V- fan or valve control, a different power supply must be used to power the Palladiom HVAC controller and the 0 V- fan/valve actuators. For more information, see Application Note #1 (041 at www.lutron.com Semitec 3AT or equivalent NTC k at 2 C Continued on the next page... www.lutron.com/support 20

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Fan Coil Units (continued 4-pipe Systems Diagram : 4-pipe system, On / off valve, 3-speed fan H VALVE R H R FAN G 3 G 2 G 1 C VALVE R C 11 Hot valve Fan high Fan medium Fan low Cold valve L1 (hot (R H Diagram 11: 4-pipe system, On / off valve, 0 V controlled fan H VALVE R H R FAN G 3 G 2 G 1 C VALVE R C 11 Hot valve Cold valve L1 (hot (R H 0 V-** Fan * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the Palladiom HVAC controller. ** When using 0 V- fan or valve control, a different power supply must be used to power the Palladiom HVAC controller and the 0 V- fan/valve actuators. For more information, see Application Note #1 (041 at www.lutron.com Continued on the next page... www.lutron.com/support 21

HomeWorks QS Palladiom HVAC Controller Wiring Diagrams (continued Fan Coil Units (continued 4-pipe Systems (continued Diagram : 4-pipe system, 0 V valve, 3-speed fan H VALVE R H R FAN G 3 Fan high G 2 Fan medium G 1 Fan low C VALVE 11 R C L1 (hot (R H 0 V-** Hot valve Cold valve Diagram 13: 4-pipe system, 0 V valve, 0 V controlled fan H VALVE R H R FAN G 3 G 2 G 1 C VALVE R C 11 No relay output used. L1 (hot (R H 0 V-** Hot valve Fan Cold valve * If the signal source from the HVAC system is not / 24 V-, use a separate supply to power the Palladiom HVAC controller. ** When using 0 V- fan or valve control, a different power supply must be used to power the Palladiom HVAC controller and the 0 V- fan/valve actuators. For more information, see Application Note #1 (041 at www.lutron.com www.lutron.com/support 22

User Interface Heating on 3, 4 Display backlighting 1 System off 2 F / C indicator Schedule on / off (hold Auxiliary heat on Cooling on 3, 4 Fan mode Auto High Only Aux AUTO Heat On OFF Cool On On Auto Set Set Off On Heat setpoint Room temperature Cool setpoint Local hold button Medium Low Raise room setpoint Select system heat, cool, only aux, auto, or off Change fan mode Lower room setpoint Dynamic Backlight Management (DBM sensor location 1 Turns on when any button is pressed. Turns off after seconds of inactivity (programmable. Dynamic Backlight Management (DBM automatically adjusts backlight intensity based on ambient lighting conditions. 2 Room temperature and OFF are shown when system is off. 3 Icons are animated when system is actively heating / cooling. 4 Icons flash if system is temporarily delayed for HVAC equipment protection. Indicates HVAC system timeclock event status. Aux indicates that auxiliary heat is running with the other heat stages. Only Aux indicates that auxiliary heat is running without the other heat stages (emergency heat. Display shows the heat or cool setpoint. The first raise/lower button press activates the LCD backlight. Additional raise/lower button presses adjust the setpoint. Applicable modes are configurable via the HomeWorks QS software. Enables / disables HVAC system timeclock events. www.lutron.com/support 23

Remote Temperature Sensor If it is not possible to follow the recommended mounting guidelines on page, use an indoor remote temperature sensor for proper temperature control. The internal thermostat sensor must be disabled through advanced programming via the thermostat. See the thermostat programming guide. Wired Flush Mount Sensor (LR-TEMP-FLSH Flush mount on wall in the area to be controlled. Field paintable to match decor. Front View Wiring Use 22 AWG (0. mm 2 twisted, shielded pair wiring. Maximum wire length: 0 ft (30. m 0. (1 Side View 0. (1 4 (2 HomeWorks QS Palladiom HVAC controller Isolated common Remote temperature sensor Wired flush mount sensor Mounting Use appropriate mounting instructions from the Mounting section on page. Wall Self threading wall insert Sensor 0. in (13 mm pilot hole Outside Wall Inside Wall Wired flush mount sensor 4 ft to ft (1.2 m to 1. m HomeWorks QS Palladiom thermostat HomeWorks QS Palladiom HVAC controller www.lutron.com/support 24

Colors and Finishes Architectural Matte Finishes Almond AL Beige BE Black BL Brown BR Gray GR Ivory IV Architectural Metal Finishes Bright Brass BB Bright Chrome BC Bright Nickel BN Satin Brass SB Satin Chrome SC Satin Nickel SN Light Almond LA Sienna SI Taupe TP White WH Glass Finish Clear Black Glass CBL Clear White Glass CWH Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors. Color chip keychains are available for more precise color matching: - Architectural Matte Finishes: AM-CK-1 - Architectural Metal Finishes: AMTL-CK-1 Lutron, Lutron, HomeWorks, and Palladiom are trademarks of Lutron Electronics Co. Inc., registered in the U.S. and other countries. Mitsubishi is a registered trademark of Mitsubishi Electric Corporation. CoolAutomation is a trademark of CoolAutomation Ltd. LG is a registered trademark of LG Corp. Daikin is a registered trademark of Daikin Industries, Ltd. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. www.lutron.com/support 2