This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Similar documents
Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

PRODUCT CONFORMITY CERTIFICATE

HFID Heated Total Hydrocarbon Analyzer Module

Series 9000 Total Hydrocarbon Analyzer

FIXED GAS ANALYZER (FGA)

Specifications for Fluorocarbon Refrigerants

Specifications for Fluorocarbon Refrigerants

Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING

Datalogging as standard

Corpus Christi - Air Monitoring Project

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

intrinsically safe detector for hydrocarbon gases

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Complete Gas Analysis

Analyze IT. Process Gas Chromatograph. PGC2000 Series

A New Standard of Excellence

INDEX 100 GENERAL 101 PURPOSE 102 EXEMPTION, VACUUM CONDITION 103 EXEMPTION, VAPOR PRESSURE

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

Chemtron Science Laboratories Pvt. Ltd.

PRODUCT CONFORMITY CERTIFICATE

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

C-NRPP Quality Assurance Guidance for Radon Test Devices

CERTIFICATE of Product Conformity (QAL1 )

IC Professional Detector

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Thermo Scientific TVA2020 Introduction

CALIDUS tm the Modular micro Gas Chromatograph

Specifications for Refrigerants

FPD - Flame Photometric Detector

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

PRODUCT CONFORMITY CERTIFICATE

RK Multi Point Detector Operator s Manual

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

RK-02 Multi Point Detector Operator s Manual

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

Operation and Maintenance Manual

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Gas Chromatography (GC-342)

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

GC Injectors. GC Injectors

RK Carbon Monoxide Transmitter Operator s Manual

Refrigerant Management Requirements Update

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

CERTIFICATE of Product Conformity (QAL1 )

Aromatics and Oxygenates in Gasoline June2018

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

SEC Signature Process Gas Analyzer

RK/ RK Carbon Monoxide Detector Operator s Manual

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

SEC-MALS Noise Assessment and Cleaning Guide

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

PIP PCTPA001 Testing of Process Analyzer Systems

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

SIMRAD GD10PE IR GAS DETECTOR

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Specifications for Refrigerants

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Declaration of Conformity

RK-05 Carbon Monoxide Detector Operator s Manual

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Process Gas Chromatograph

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Process Gas Chromatograph

RK-05 Combustible Gas Transmitter Operator s Manual

Recent Improvements in Process GC Instrumentation

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Process Gas Chromatograph

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Evaluation of the Red Jacket Fx1, Fx2, Fx1V and Fx2V Line Leak Detectors For Hourly Monitoring on Rigid Pipelines. Final Report

AS/NZS :2008

GAS ANALYSIS / DETECTION Gas Detector

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Certificate: _02 / 9 September 2014

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Certificate of Completion

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

CERTIFICATE of Product Conformity (QAL1 )

Ambient air quality monitoring

Gas Detection - GD -

Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

RK-03 Hydrogen Detector Operator s Manual

PQS performance specification

continuous emissions monitoring Combustion & Environmental Monitoring

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

Transcription:

Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and Non-Methane Hydrocarbons Using Gas Chromatography Reference No: SOP-10 Parent Document: Part B1 B.C. Field Sampling Manual 1. Introduction and Scope This Standard Operating Procedure (SOP) provides operating guidelines and instructions for the continuous ambient monitoring of Methane and Non-Methane Hydrocarbons (NMHC), within the provincial jurisdiction of British Columbia (B.C.). This SOP forms part of the B.C. Field Sampling Manual (BCFSM). Part B - Air and Air Emissions Testing, of the BCFSM provides additional information on Air Quality Monitoring that must be used in conjunction with the information provided in this SOP. Installation and maintenance of a Methane/NMHC analyzer within the provincial jurisdiction of B.C. should be carried out with consideration to Part B of the BCFSM, the analyzer manufacturer s manual, and this document. 2. Document Control This Standard Operating Procedure is a controlled document. Document control provides a measure of assurance that the specifications and guidance it provides are based on current information that has been scrutinized by a qualified reviewer/s. Controlled documents are reviewed within a five year life cycle. Please ensure that the revision date listed in the header of this document does not exceed five years. This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca. 3. Principle of the Measurement Method Gas Chromatography (GC) The principle detection and quantification method deployed for monitoring Methane and Non-Methane Hydrocarbons (NMHC) in ambient air is gas chromatography (GC). Methane/NMHC analyzers use a semicontinuous collection and analysis sequence that draws air samples into a separation column where it is pushed by an inert carrier gas into a flame ionization detector (FID). Due to the differences in molecular weight and volatility the sample s various gas components are separated based on retention time. Retention time is described as the time it takes for a component to travel though and emerge from the column. Methane has a lower molecular weight and higher volatility than other hydrocarbons which results in a lower retention time. For this reason methane is the first compound to emerge from the separation column. The Methane is then directed to a flame ionization detector (FID). The signal produced by the FID is converted to a methane concentration by comparing the response to a known concentration of a methane standard. Non-methane hydrocarbons emerging later from the separation column produce an FID signal which is converted to an NMHC concentration using comparisons with a known concentration of a propane standard. After the NMHC measurement is complete, the analyzer initiates the next sample analysis. Page 1 of 6

Figure reference: Thermo Scientific, 2012 A typical gas chromatogram from a Thermo Scientific Model 55i Analyzer using 2 ppm each of methane and propane (a NMHC) is shown in the figure above. 4. Interferences Particulate Matter The presence of particulate matter in air samples may interfere with Methane/NMHC analyzer response. Interference by particulate matter can be minimized by using a particle filter at the sample inlet. The filter must have a 2 µm diameter pore size and be made of an inert material such as Teflon. 5. Precision and Accuracy The precision of an analysis is generally considered to be the repeatability of the measurement. This can be confirmed through zero and span checks, and calibrations. The accuracy of the sensor is generally considered to be a measure of the deviation from true. The accuracy of a sensor can be checked by performing calibrations against a certified calibration standard mixture (See Sections 11 and 12). Accuracy can also be confirmed through periodic span checks and multipoint checks/calibrations. 6. Recommended Equipment and Apparatus The following are common commercially available methane/nmhc analyzers suitable for use within the provincial jurisdiction of B.C.: Thermo Scientific Direct Methane, Non-Methane Hydrocarbon Analyzer, Model 55i Synspec GC s Alpha 115 This list does not necessarily exclude other commercially available Methane/NMHC analyzers, and analyzers recognized by the United States (US) Environmental Protection Agency (EPA) Federal Reference and Equivalent Methods. In deed as technology advances, new analyzers will enter the market which may be suitable for use within the provincial jurisdiction of B.C. It is highly recommended however that you consult with the B.C. Ministry of Environment and Climate Change Strategy (ENV) if Page 2 of 6

you intend to deploy Methane/NMHC analyzers that are not listed above. Regardless of the instrument deployed, all analyzers should meet the specifications described within this document. 7. Measurement Range and Sensitivity Typical commercially available Methane/NMHC analyzers operate at user selectable ranges between 0 ppm and 5000 ppm; for B.C. ENV monitoring purposes analyzers should be set to a range of 0 ppm to 20 ppm for Methane/NMHC. The detection limit is determined by instrument type but is generally around 0.05 ppm. 8. Site Requirements Monitoring site specifications should be developed to ensure that the data obtained from the site satisfies the requirements of intended or established monitoring objectives. It is highly recommended that monitoring site requirements be established in consultation with the B.C. ENV to ensure that siting requirements are commensurate with monitoring objectives. As a preliminary guideline site selection should consider and address monitoring objectives, representativeness of the region, interference from the surrounding area, and zone type (residential, commercial, industrial) of the monitoring location. Refer to Section XX of the BCFSM for further information on site selection. 9. Installation Requirements Follow analyzer specific installation requirements discussed in the analyzer manufacturer s manual. The installation should also conform to the following: The monitoring station s sampling inlet and manifold shall meet the requirements of the most recent version of the National Air Pollution Surveillance (NAPS) Program s Monitoring and Quality Assurance/Quality Control Guidelines Section 8.2 and Section 8.3. The ¼ inch diameter connection tubing from the manifold to the analyzer inlet must be made of Teflon or equivalent material for chemical inertness. A Teflon particulate filter capable of removing at least 99% of 1 µm diameter and larger particles must be placed in the sampling line upstream of the analyzer, unless the analyzer is equipped with a similar internal filter. The filter holder should be constructed of an inert material (e.g. Teflon, stainless steel). A data acquisition system ( DAS or data logger ) should be connected to the analyzer to record or download the measurement data from the analyzer. If an analog data logger is used, it must be set to match the voltage range of the analyzer, typically at 1 V or 10 V full scale. It must be ensured that the analog output matches the digital output displayed on the analyzer. The data logger must also record and monitor any alarm conditions of the analyzer. The analyzer must be placed in a weather resistant enclosure that is vented, heated and cooled to maintain a stable temperature preferably in the range of 20 C and 30 C but must be capable of maintaining the operating temperature range specified by the manufacturer. Enclosure temperatures should not deviate by more than 2 C over a one hour period. Page 3 of 6

10. Operational Requirements The following activities should be performed by the operator of a continuous automated Methane/NMHC analyzer. Action Time/Frequency Description Record Keeping Analyzer Range Set Up Multipoint Verification After installation After installation (or relocation) following a 24 h to 72 h warm up period; After analyzer repairs/maintenance that may affect performance of the instrument; When zero check exceeds ± 0.1ppm; When span drift is ± 10% of reference value; For new analyzers, after the first 3 months of operation; Bi-annually if span checks are conducted daily or when any threshold above is reached (whichever happens first); Quarterly if span checks are conducted less than daily or when any threshold above is reached (whichever happens first). Monitoring range should be 0 ppm to 20 ppm. As per Section 12 of this SOP. Record in logbook, see example station installation record (BCFSM, Appendix XX) Record in logbook, see example gas calibration activity record (BCFSM, Appendix XX) Zero and Span Verification Verify Operational Parameters Check Support Gas Pressures Inlet Filter Change Daily preferred, weekly minimum Each monitor station visit Each monitor station visit Inspect monthly, change as required Check gas cylinder pressures and replace if they drop below 500 psi. A filter change can affect flow and pressure so a verification or full calibration is required. Record in logbook, see example routine maintenance record (BCFSM, Appendix XX) Page 4 of 6

Analyzer Maintenance Sample Path Inspection (Probe to Analyzer) As recommended by manufacturer or as required Each monitor station visit Where necessary replace with new lines, tighten loose connections, clean manifold if required. Any alteration to the sample pathway should be accompanied by verification or full calibration. Record in logbook Record in logbook 11. Zero and Span Checks Zero and span checks are required to verify analyzer performance between calibrations. These checks should be performed in accordance with Section XX of the BCFSM. 12. Calibration Calibration should be performed in accordance with Section XX of the BCFSM and following the manufacturer s manual. Methane/NMHC analyzers are typically calibrated using the dilution method 13. References National Air Pollution Surveillance (NAPS) Program. Monitoring and Quality Assurance/Quality Control Guidelines. Alberta Environment (AENV) 2011. Standard Operating Procedure for Measurement of Methane/Non- Methane Hydrocarbons Using FID Detection. AENV Air Monitoring and Audit Centre. CARB 2002. Standard Operating Procedure for the Determination of non-methane Organic Compounds in Ambient Air by Gas Chromatography Using Dual Capillary Columns and Flame Ionization Detection. Northern Laboratory Branch Monitoring and Laboratory Division. Synspec 2010. Synspec GC s Alpha 115 and Alpha 116 Methane/Total Non Methane HydroCarbons Operator manual. Thermo Scientific 2012. Model 55i Instruction Manual Direct Methane, Non-Methane Hydrocarbon Analyzer. United States Environmental Protection Agency (US EPA) 2013. QA handbook for Air Pollution Measurement Systems Volume II Ambient Air Quality Monitoring Program. US EPA Office of Air Quality Planning and Standards Air Quality Assessment Division. Wood Buffalo Environmental Association (WBEA) 2013. Procedures for Operating Continuous Methane/Non-Methane Hydrocarbon Analyzers. Revision History: 0.0 (New document) Approval Page 5 of 6

Page 6 of 6