Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Similar documents
Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

Series 25B Photoelectric Sensors and Light Scanners PRODUCT INFORMATION

MSI Safety relays. MSI-T functions

PHOTOELECTRIC AMPLIFIER SERIES

Ultrasonic Proximity Sensor

Retroreflective sensor with polarization filter

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

46C SERIES. powerreserve. Photoelectric sensors and light scanners with maximum function reserve.

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Class 1 laser beam sensor safe for your eyes

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

E3FA PHOTOELECTRIC SENSORS

BOS 23K. Photoelectric Sensors BOS 23K

Class 1 laser beam sensor safe for your eyes

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Laser Distance Sensor Type M Analog-Output

5.0. Photoelectric Sensors. Technical Reference. Introduction

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Retro-reflective Sensing range: 0mm to 2000mm

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

CATALOGUE LASER POINTERS

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

General Specifications

Retroreflective sensor with polarization filter

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Class 1 laser beam sensor safe for your eyes

E3FA PHOTOELECTRIC SENSORS

E3FA PHOTOELECTRIC SENSORS

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

HRTL 96B Laser light scanner featuring background suppression for object detection and accurate positioning

Laser Collimated Beam Sensor

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

COMPACT FLAME CONTROLLER CFC 2000

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

COMPACT FLAME CONTROLLER CFC 1000

Plug-in Base, Long Range Sensor E3B2

The Affordable, All-Purpose Sensor That's EZ To Use!

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Ultrasonic Proximity Sensor

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

GENERAL APPLICATION SENSORS NEW! MINI-EYE. General Application Photoelectric Sensors. Small, Rugged and Powerful... yet Low in Price MINI-EYE 2-55

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

2 General Application Photoelectric Sensors

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Technical Data. General specifications. Rated operating distance s n 5 mm

Reliable Detection of Transparent Objects

Compact Catalog Solar

Automatic Self-Adjusting General Purpose Sensor

E3M-V. Mark Sensor. Applications

Safety Light Curtains Area Access Control

MINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. General Purpose Photoelectric Sensor

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

English. Series. Installation and Use Manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

2 General Application Photoelectric Sensors

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

FR Series Photoelectric Sensors

2 General Application Photoelectric Sensors

/ / 2018

E3FA PHOTOELECTRIC SENSORS

2 General Application Photoelectric Sensors

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

S15 SERIES. Ceramics. Beverage & Bottling

2 General Application Photoelectric Sensors

Operating Manual MS220DA

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Reflective Optical Beam Smoke Detector User Guide

MINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. Miniature Sensor

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Infrared Single Light Barrier. Mounting Instructions DO560

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

OG-Cube Photoelectric Sensors Optical sensing technology

General Purpose Photoelectric Sensor

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

INSTRUCTION & SERVICE MANUAL

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

Transcription:

Technical data and description LS 55 Throughbeam photoelectric sensor for the detection of aqueous liquids Dimensioned drawing en 03-2016/11 50127872-02 350 Hz 0 80m 10-30 V DC We reserve the right to make changes DS_LS55H2O_en_50127872_02.fm Throughbeam photoelectric sensor for the detection of aqueous liquids in glass and plastic containers (bottles, syringes, trays, etc.) Radiation through transparent, colored glass and PET containers, even with printed plastic labels Model for monitoring the fill level with glass and plastic containers Power adaptation for container diameter 10 300mm 316L stainless steel housing in WASH-DOWN-Design ECOLAB and CleanProof+ tested IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 Cable with M8 or M12 connector (K-D ) Cable for food and beverages Mounting devices A B Optical axis Indicator diodes Electrical connection Connector, 4-pin Transmitter LSS 55 Receiver LSE 55 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.com www.leuze.com LS 55-03

Technical data Optical data Typ. operating range limit 1) 0 80m Operating range 2) 0 64m Application range 0 0.5m Light source 3) LED (modulated light) Wavelength 1450nm (infrared light) Timing Switching frequency 350Hz Response time 1.43ms Readiness delay 300ms Electrical data Operating voltage UB 4) 10 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 20mA (per sensor) Switching output /44 2 PNP transistor switching outputs, antivalent pin 2: dark switching pin 4: light switching Function light/dark switching Signal voltage high/low (U B -2V)/ 2V Output current max. 100mA Sensitivity adjustable on the transmitter via pin 2 and pin 4 Indicators Green LED ready Yellow LED light path free Mechanical data Housing AISI 316L stainless steel, DIN X2CrNiMo17132, W.No1.4404 Housing design WASH-DOWN design Housing roughness 5) Ra 2.5 Connector AISI 316L stainless steel, DIN X2CrNiMo17132, W.No1.4404 Optics cover coated plastic (PMMA), scratch resistant and non-diffusive Operation plastic (TPV-PE), non-diffusive Weight with M8 connector: 40g with 200mm cable and M12 connector: 60g with 5000mm cable: 110g Connection type M8 connector, 3-pin or 4-pin, 0.2m cable with M12 connector, 4-pin, 5m cable, 4 x 0.20mm² Environmental data Ambient temp. (operation/storage) 6) -30 C +65 C/-30 C +70 C Protective circuit 7) 2, 3 VDE safety class 8) III Degree of protection IP 67, IP 69K 9) Environmentally tested acc. to ECOLAB, CleanProof+ Light source exempt group (in acc. with EN 62471) Standards applied IEC 60947-5-2 Certifications UL 508, C22.2 No.14-13 4) 10) Chemical resistance tested in accordance with ECOLAB and CleanProof+ (see Remarks) Additional functions Transmitter sensitivity (see Sensitivity adjustment) Pin 2 active/not active 8V/ 2V Pin 4 active/not active 8V/ 2V Activation delay 1ms Input resistance 30kΩ 1) Typ. operating range limit: max. attainable range without function reserve in transmitting level 4 2) Operating range: recommended operating range with function reserve in transmitting level 4 3) Average life expectancy 100,000h at an ambient temperature of 25 C 4) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC 5) Typical value for the stainless steel housing 6) Operating temperature in transmitting level 4 is limited to -30 C +55 C 7) 2=polarity reversal protection, 3=short circuit protection for all transistor outputs 8) Rating voltage 50V 9) Only in combination with M12 connector 10) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7) Tables 0 64 80 Operating range [m] Typ. operating range limit [m] Diagrams Factor 10 6 10 5 10 4 10 3 10 2 10 1 Typical function reserve 10 0 0.05 0.5 5 Distance [m] A Sensitivity level 1 B Sensitivity level 2 C Sensitivity level 3 D Sensitivity level 4 Remarks A B C D Observe intended use! This product is not a safety sensor and is not intended as personnel protection. The product may only be put into operation by competent persons. Only use the product in accordance with the intended use. Colored liquids and labels increase the damping The function reserve can be adjusted on the transmitter (pin 2 + pin 4) The function reserve can be reduced by misaligning the receiver A light axis consists of a transmitter and a receiver with the following designations: LS = Complete light axis LSS = Transmitter LSE = Receiver UL REQUIREMENTS Enclosure Type Rating: Type 1 For Use in NFPA 79 Applications only. Adapters providing field wiring means are available from the manufacturer. Refer to manufacturers information. CAUTION the use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ATTENTION! Si d'autres dispositifs d'alignement que ceux préconisés ici sont utilisés ou s'il est procédé autrement qu'indiqué, cela peut entraîner une exposition à des rayonnements et un danger pour les personnes. A list of tested chemicals can be found in the first part of the product description. LS 55-03 2016/11

Throughbeam photoelectric sensor for the detection of aqueous liquids Order guide Selection table Equipment Order code Switching output 2 x PNP transistor output, antivalent Switching function Pin 4: light switching Pin 2: dark switching Connection M8 connector, metal, 4-pin M8 connector, metal, 3-pin Cable 200mm with M12 connector, metal, 4-pin Cable 5000mm, 4-wire Indicators Green LED: ready Yellow LED: switching output Features Activation input Sensitivity switch-over on the transmitter Receiver for detection of aqueous liquids Receiver for fill-level monitoring Customer-specific version Detection of aqueous liquids LS 55/44.H2O, 200-S12 Part no. 50127771 (Tr) Part no. 50127772 (Re) Customer-specific version LS 55/44.H2O.K, 200-S12 Part no. 50135166 (Tr) Part no. 50135165 (Re) Fill-level monitoring LS 55/441.H2O,200-S12 Part no. 50127771 (Tr) Part no. 50130550 (Re) Detection of aqueous liquids in glass and plastic containers (bottles, syringes, trays, etc.) Recommendation for the sensitivity adjustment on the transmitter Distance transmitter/ Transmitter pin 4 Transmitter pin 2 Sensitivity receiver 1) Not connected or 0V U B Level 1 (min.) 50 100mm Not connected or 0V Not connected or 0V Level 2 (default) 100 500mm U B U B Level 3 100 500mm U B Not connected or 0V Level 4 (max.) 100 500mm 1) Additional reduction of the sensitivity by misaligning the receiver 2) Typical details, strong dependence on container color and water column diameter 3) Other containers and foils depending on material and sensor distance 4) Plastic labels, also with printing Formats 2) 3) Container < 0.5l, without label Container 0.1 2l, without label Container 0.1 5l, without label Container 0.1 5l, with label 4) Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LS 55-03 info@leuze.com www.leuze.com

Notice on correct alignment and sensitivity selection 1.Mount transmitter and receiver. For receiver, provide for possibility of tilting 0 15. The bottles should not be detected directly in front of the receiver. Observe the following installation recommendation: Max. 2/3 x distance transmitter/receiver 2.Exactly align the optical axis. 3.Rough adjustment of the sensitivity on the transmitter according to the sensitivity table. Rough adjustment of the sensitivity Adjustment on the transmitter via pin 2 and pin 4 acc. to table (page 3) 4.Check: empty bottle must not result in interruption. In the event of interruption: increase sensitivity (on transmitter: pin 2, pin 4) or reduce the transmitter/receiver distance. 5.Filled bottle must consistently result in interruption. Otherwise, reduce the sensitivity (on transmitter: pin 2, pin 4) and/or fine tune the sensitivity. Fine tuning the sensitivity + Adjustment via the tilt angle: Tilt angle 0 ±15 : 15 = reduced sensitivity LS 55-03 2016/11

Throughbeam photoelectric sensor for the detection of aqueous liquids Fill-level monitoring with glass and plastic containers The photoelectric sensor can be used to determine fill levels during the filling of containers with beverages (e.g., water, fruit juices, beer, wine, milk) or aqueous solutions (e.g., cleaners, acids, bases, alcohols). Recommendation for the sensitivity adjustment on the transmitter A transmitter adjustment is not normally necessary, i.e., inputs IN1 and IN2 on the transmitter remain disconnected. If the sensor does not generate a switching signal with this setting, the transmitting power must be reduced to level 1 (min.) according to the table on page 3 Recommendation for the sensitivity adjustment on the transmitter. Notice on correct alignment of the photoelectric sensor In principle, transmitter and receiver can be mounted at any distance to the container. If feasible, we recommend a distance of 10-40 mm. Min. 15mm Vertical arrangement of the sensors Approx. 10 40 mm Top View Min. 15mm Horizontal arrangement of the sensors Top View Approx. 10 40 mm 1.The optical axis of transmitter and receiver must be exactly oriented horizontally as well as vertically. Refer to the dimensioned drawing on page 2 for the orientation of the optical axis. 2.At the position where the fill level is to be monitored, the light beam must not be directed through the filling beam. 3.The optical axis must pass through the bottle at a distance of at least 15 mm from the outer wall of the container. 4.The fill-level monitoring is largely independent of the bottle geometry, thickness or color. If the surface of the liquid is smooth and level during the filling process, very good reproducibility of typically 0.2 to 0.5 mm can be achieved. The more wavy or turbulent the surface of the liquid is during the filling process, the lower the reproducibility. No generalizations can be made here; values must be determined through practical trials. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LS 55-03 info@leuze.com www.leuze.com

LS 55-03 2016/11