VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Similar documents
VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOCAL 200-S. for contractors

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation and service instructions VITOCAL 300-A. for contractors

VIESMANN. Service instructions. MatriX radiant burner. for contractors

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

for contractors Vitosolic 200 Type SD4 For applicability, see the last page Please keep safe.

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation and service instructions VITODENS 050-W. for contractors

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

for contractors Vitosolic 100 Type SD1 For applicability, see the last page Please keep safe.

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

VIESMANN. Installation and service instructions VITOTRONIC 200. for contractors

VIESMANN. Installation and service instructions VITODENS 200-W. for contractors

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN. Installation and service instructions VITODENS 050-W. for contractors

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

VIESMANN. Installation and service instructions VITOTRONIC 200 VITOTRONIC 300. for contractors

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

Installation Instructions VITOTRONIC 300

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

VIESMANN. Installation and service instructions VITODENS 100. for heating engineers

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Installation Instructions VITOTRONIC 200

VIESMANN. Installation and service instructions VITODENS 343-F. for contractors

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

VIESMANN. Service instructions VITODENS 200-W. for contractors

O CRC100. Comfort Room Controller (2015/01) en

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Installation, operating and servicing instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

VIESMANN. Installation and service instructions VITODENS 200-W. for contractors

Technical information for installation and operation

Roth fixed-value control set with high-efficiency pump

3-way switching valve

AC THOR. Assembly Instructions

1 Declaration of conformity

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

Installer manual ELK 213 Immersion heater

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Service Instructions for use by heating contractor

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Operating instructions

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

RE-PR3-E-27 3-Phase Panel Mount 27kW

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Heating controller Lago

Use. For 2-pipe fan coils

FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service.

for use by heating contractor Vitotronic 300 Type GW2B IMPORTANT Read and save these instructions for future reference.

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

EN Z Subject to change due to technical improvements! Operating instructions

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

Installation and maintenance manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Transcription:

Installation instructions for contractors VIESMANN Mixer extension kit For one heating circuit with mixer Mixer extension kit 5/2017

Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained! Danger This symbol warns against the risk of injury. Please note This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These instructions are exclusively intended for qualified contractors. Work on gas installations may only be carried out by a registered gas fitter. Work on electrical equipment may only be carried out by a qualified electrician. Regulations to be observed National installation regulations Statutory regulations for the prevention of accidents Statutory regulations for environmental protection Codes of practice of the relevant trade associations All current safety regulations as defined by DIN, EN, DVGW, TRGI, TRF, VDE and all locally applicable standards a ÖNORM, EN, ÖVGW G K directives, ÖVGW-TRF and ÖVE c SEV, SUVA, SVGW, SVTI, SWKI, VKF and EKAS guideline 1942: LPG, part 2 2

Safety instructions (cont.) Working on the system Isolate the system from the power supply (e.g. by removing the separate fuse or by means of a mains isolator) and check that it is no longer 'live'. Safeguard the system against reconnection. Where gas is used as the fuel, close the main gas shut-off valve and safeguard it against unintentional reopening. 3

Index Installation sequence Mounting the mixer extension kit... 5 Mixer mounting... 5 Wall mounting... 6 Mounting the temperature sensor... 6 Overview of electrical connections... 8 Connecting the temperature sensor... 9 Connecting the mixer motor... 9 Mixer motor... 9 Mixer motors without plug or on-site mixer motors... 10 Connecting the heating circuit pump... 10 Heating circuit pump 230 V~... 11 Heating circuit pump 400 V~... 13 Pumps in the underfloor heating circuit... 13 Temperature limiter for restricting the maximum temperature (accessories)... 14 Floorstanding boilers... 15 Vitocrossal/Vitodens/Vitopend... 16 Vitodens 300-W, type WB3E/B3HA, Vitodens 333-F, type B3TA... 18 Vitodens with integral solar control module... 20 Vitoladens/Vitoplus 300... 22 Vitocal... 23 Connecting several accessories... 24 Power supply and KM-BUS connection... 24 Separate mains connection... 25 Commissioning... 27 Rotational direction of the mixer motor... 28 Specification... 29 Connection and wiring diagram... 30 Declaration of Conformity... 31 Keyword index... 32 4

Mounting the mixer extension kit Mixer mounting 2. M6/M8 M6 4. 3x 3. M8 M6 M6 M8 M8 M8 M6 1. 3x 5

Mounting the mixer extension kit (cont.) Wall mounting 1. 2. Mounting the temperature sensor Fit the flow temperature sensor to the heating flow pipe immediately downstream of the heating circuit pump in the flow direction. Only in conjunction with the Vitotronic 300, type KW3: Fit the return temperature sensor to the heating return pipe. When using plastic pipes, fit the sensor to a metal intermediate piece. Clean the flow/return pipe down to bare metal. Heat conducting paste is not required. Do not thermally insulate the temperature sensor. 6

Mounting the temperature sensor (cont.) 2. 1. 100 4. 3. 7

Overview of electrical connections S1 F1 52 20 40A 40 145 2 145 17 52 20 40A 40 F1 MCB/fuse 2 A (slow) S1 Rotary switch Plug 230 V~ sö Heating circuit pump (on site) fö Mains connection föa Mains connection for accessories gs Mixer motor! Please note Electronic assemblies can be damaged by electrostatic discharge. Prior to commencing any work, touch earthed objects such as heating or water pipes to discharge static loads. LV connections? Flow temperature sensor aj Return temperature sensor (only in conjunction with the Vitotronic 300, type KW3) avg KM-BUS 8 Note Apply strain relief to on-site cables. Seal any unnecessary apertures with cable grommets (not cut open).

Connecting the temperature sensor 1. Flow temperature sensor Connect plug? to the PCB (see diagram on page 8). 2. Return temperature sensor Only in conjunction with the Vitotronic 300, type KW3: Connect plug aj to the PCB. Connecting the mixer motor Only in conjunction with extension kit for wall mounting Mixer motor 1 2 3 A Connect the mixer motor in accordance with the diagram in the wall mounting base of the extension kit. Never interchange cores. gs A Plug on mixer motor gs Plug on mixer extension kit Mixer open ~ Mixer close 9

Connecting the mixer motor (cont.) Mixer motors without plug or on-site mixer motors M 1~ A Connect the mixer motor in accordance with the diagram in the wall mounting base of the extension kit. Never interchange cores. gs A Mixer motor gs Plug on mixer extension kit Mixer open ~ Mixer close The mixer motor must meet the following criteria: Rated voltage 230 V~ Rated breaking capacity of the relay output 0.2 (0.1) A Runtime for 90 120 s Rotational direction Can be changed Connecting the heating circuit pump Note In underfloor heating circuits, install a temperature limiter on site to restrict the maximum temperature of the underfloor heating system. 10

Connecting the heating circuit pump (cont.) Heating circuit pump 230 V~ M 1~ A Specification Rated current Recommended connecting cable 2(1) A H05VV-F3G 0.75 mm 2 or H05RN-F3G 0.75 mm 2 B A Heating circuit pump B Plug sö on the mixer extension kit Heating circuit pump with power consumption greater than 2 A or high efficiency circulation pump with high starting currents Pumps with switching input N L L D N L N C B External ON/OFF L N PE A A Heating circuit pump B Plug sö on the mixer extension kit C Contactor D Separate mains connection (observe manufacturer's instructions) 11

Connecting the heating circuit pump (cont.) Pumps without switching input L D N N L L N C L N PE B A A Heating circuit pump B Plug sö on the mixer extension kit C Contactor D Separate mains connection (observe manufacturer's instructions) 12

Connecting the heating circuit pump (cont.) Heating circuit pump 400 V~ N C L L1 L2 L3 N PE Specification for switching the contactor: Rated voltage 230 V~ Rated current 2(1) A Recommended connecting cable H05VV-F3G 0.75 mm 2 or H05RN-F3G 0.75 mm 2 B A 3~ M A Heating circuit pump B Plug sö on the mixer extension kit C Contactor Pumps in the underfloor heating circuit N L 20 sö The common power consumption of both pumps must not exceed 2 A. M 1~ M 1~ A B C sö Plug on mixer extension kit A Primary heating circuit pump B Temperature limiter C Secondary heating circuit pump (in connection with system separation) 13

Connecting the heating circuit pump (cont.) Temperature limiter for restricting the maximum temperature (accessories) C L? N L? N Electromechanical temperature limiter according to the liquid expansion principle. Switches the heating circuit pump off when the set value has been exceeded. The flow temperature decreases only slowly in this situation, i.e. it may be several hours before the system restarts again automatically. Connection: Screw terminals for 1.5 mm 2 B Specification Setting range 30 to 80 C Switching differential Immersion thermostat Max. 11 K Contact thermostat Max. 14 K A M 1~ A Heating circuit pump B Temperature controller/temperature limiter C Plug sö of the temperature controller/temperature limiter to the mixer extension kit 14

2 3 4 5 61 Floorstanding boilers Vitotronic 200, type KO1B and KO2B Vitotronic 300, type KW3 B Make the electrical connections. 96 145 N 1 2 L 1 L 156 N Danger Incorrect core assignment can result in serious injury and damage to the appliance. Take care not to interchange wires "L1" and "N". 1 2 A S1 145 40 78 9 0 N L avg fö A Mixer extension kit fö Power supply avg KM-BUS S1 Rotary switch: See the following table for position B To Vitotronic control unit avg KM-BUS to the Vitotronic control unit or to the KM-BUS distributor (accessories) lh Power supply via Vitotronic 200 abh Power supply via Vitotronic 300 or mains distributor (accessories) Setting the rotary switch: Heating circuit affected by the mixer Heating circuit 2 with mixer M2 Sensors connected Flow temperature sensor Only in conjunction with the Vitotronic 300, type KW3: Flow temperature sensor and return temperature sensor Rotary switch S1 "2" (delivered condition) "3" 15

Floorstanding boilers (cont.) Heating circuit affected by the mixer Heating circuit 3 with mixer M3 Sensors connected Flow temperature sensor "4" Only in conjunction with the "5" Vitotronic 300, type KW3: Flow temperature sensor and return temperature sensor Rotary switch S1 Vitocrossal/Vitodens/Vitopend Vitotronic 200, type HO1, HO1A, HO1B and HO2B in conjunction with Vitodens/Vitopend. Vitotronic 200, type KW6, KW6A and KW6B in conjunction with Vitocrossal 300, type CU3A. Vitodens 242-F and 343-F with integral solar control module: See page 20. Vitodens 300-W, type WB3E and B3HA: See page 18. 16

2 3 4 5 61 Vitocrossal/Vitodens/Vitopend (cont.) X3 100 35 20 96 7654321 N L1 B A 1 2 N L S1 145 40 78 9 0 Make the electrical connections. Danger Incorrect core assignment can result in serious injury and damage to the appliance. Take care not to interchange wires "L1" and "N". Note If the power supply terminal is already assigned, see page 25. avg fö A Mixer extension kit fö Power supply avg KM-BUS S1 Rotary switch: See the following table for position B Vitotronic control unit "X3" KM-BUS at terminals "7" and "6" (disconnect plug avg) or With plug avg to the KM-BUS distributor (accessories) lh Power supply Setting the rotary switch: Heating circuit affected by the mixer Heating circuit 2 with mixer M2 Only in conjunction with Vitotronic 200, type HO1A, HO1B, KW6A and KW6B: Heating circuit 3 with mixer M3 Rotary switch S1 "2" (delivered condition) "4" 17

2 3 4 5 61 Vitodens 300-W, type WB3E/B3HA, Vitodens 333-F, type B3TA Vitotronic 200, type HO1B, HO2B, HO1C and HO2C X14 145 X3 100 35 28 20 96 2 1 5 4 32 1 N?L1 B A 1 2 N L S1 145 40 78 9 0 avg fö A Mixer extension kit fö Power supply avg KM-BUS S1 Rotary switch: See the following table for position B Vitotronic control unit avg KM-BUS at terminals "1" and "2" (disconnect plug avg) or With plug avg to the KM-BUS distributor (accessories) lh Power supply 18

Vitodens 300-W, type WB3E/B3HA, Vitodens 333-F, (cont.) Make the electrical connections. Danger Incorrect core assignment can result in serious injury and damage to the appliance. Take care not to interchange wires "L1" and "N". Note If the power supply terminal is already assigned, see page 25. Setting the rotary switch: Heating circuit affected by the mixer Rotary switch S1 Heating circuit 2 with mixer M2 "2" (delivered condition) Heating circuit 3 with mixer M3 "4" 19

2 3 4 5 61 Vitodens with integral solar control module Vitodens 242-F or 343-F with solar control module, type SM1 X4 145 X3 100 35 28 20 96 2 1 5 4 32 1 N?L1 A X4 X3 100 35 20 96 7654321 N L1 1 2 B C S1 145 40 78 9 0 N L avg f-]a fö N L 40 A 1 2 D N L 145 40 avg fö 20

Vitodens with integral solar control module (cont.) A Vitotronic 200, type HO1C avg KM-BUS at terminals "1" and "2" (disconnect plug avg) or With plug avg to the KM-BUS distributor (accessories) lh Power supply B Vitotronic 200, type HO1B "X3" KM-BUS at terminals "7" and "6" (disconnect plug avg) or With plug avg to the KM-BUS distributor (accessories) lh Power supply C Mixer extension kit fö Power supply föa Solar control module power supply avg KM-BUS S1 Rotary switch: See the following table for position D Solar control module fö Power supply avg KM-BUS 1. Make the electrical connections. 2. Connect KM-BUS cable with plug avg to the mixer extension kit and cable to plug "X3" or avg. 3. Disconnect plug fö from the solar control module and connect to the mixer extension kit. 4. At the loose end of the power cable supplied (with plug fö), connect plug föa. 5. Connect plug fö of the power cable in the solar control module and plug föa in the mixer extension kit. Setting the rotary switch: Heating circuit affected by the mixer Rotary switch S1 Heating circuit 2 with mixer M2 "2" (delivered condition) Heating circuit 3 with mixer M3 "4" 21

2 3 4 5 61 Vitoladens/Vitoplus 300 Vitotronic 200, type HO1, HO1A, HO1B, KW6, KW6A and KW6B X3 124 201 abh Make the electrical connections. 7654321 B N L1 Danger Incorrect core assignment can result in serious injury and damage to the appliance. Take care not to interchange wires "L1" and "N". 1 2 A S1 145 40 78 9 0 N L Note If the power supply terminal is already assigned, see page 25. avg fö A Mixer extension kit fö Power supply avg KM-BUS S1 22 Rotary switch: See the following table for position B Vitotronic control unit "X3" KM-BUS at terminals "7" and "6" (disconnect plug avg) or With plug avg to the KM-BUS distributor (accessories) abh Power supply Setting the rotary switch: Heating circuit affected by the mixer Heating circuit 2 with mixer M2 Only in conjunction with Vitotronic 200, type HO1A, HO1B, KW6A and KW6B: Heating circuit 3 with mixer M3 Rotary switch S1 "2" (delivered condition) "4"

2 3 4 5 61 Vitocal Vitotronic 200, type WO1A, WO1B and WO1C Note For Vitocal 200 heating circuit M2 with mixer For Vitocal 300 heating circuit M3 with mixer F avg B F 145 1 2 C N L1 1 2 N L S1 145 40 78 9 0 avg A fö A Mixer extension kit fö Mains connection avg KM-BUS S1 For rotary switch position, see the following table B Vitotronic control unit avg KM-BUS to the controller and sensor PCB or to the KM- BUS distributor (accessories) C Mains connection (see page 25) Make the electrical connections. Danger Incorrect core assignment can lead to serious injury from electrical current and result in appliance damage. Never interchange cores "L" and "N". 23

Vitocal (cont.) Set the rotary switch: Function Sensors connected Rotary switch S1 Heating Flow temperature sensor "2" (delivered condition) Cooling Flow temperature sensor "4" Connecting several accessories Power supply and KM-BUS connection Power supply for all accessories via Vitotronic control unit A B C D 145 40 96 145 145 40 A 40 145 145 40 A 40 145 145 40 A 40 E Some accessories with direct power supply A B C D 145 40 96 145 145 40 A 40 145 145 40 A 40 145 145 40 A 40 E A Vitotronic control unit B Mixer extension kit for heating circuit with mixer M2 C Mixer extension kit for heating circuit with mixer M3 D AM1 extension, EA1 extension and/or solar control module, type SM1 24 E ON/OFF switch fö (A) Power supply lh/abh Power supply for accessories at the Vitotronic control unit avg KM-BUS

Connecting several accessories (cont.) In the following circumstances, use the output for the accessories only to switch an on-site relay: An actuator (e.g. circulation pump) with a higher power demand than the fuse rating required for the accessories is connected at the accessories output. In the following circumstances, connect one or more accessories directly to the mains supply via an ON/OFF switch: The max. permissible total current of the Vitotronic control unit for the heat generator is exceeded. Separate power supply: See the following chapter. Note In this event, the accessories concerned cannot be isolated with the ON/OFF switch on the Vitotronic control unit. Separate mains connection If the power supply for the extension kit is not made at the Vitotronic control unit for the heat generator. Danger Incorrect electrical installations can lead to serious injury from electrical current and result in appliance damage. 25

Separate mains connection (cont.) Implement the mains connection and all safety measures (e.g. RCD circuit) in accordance with the following regulations: IEC 60364-4-41 VDE regulations Technical connection requirements specified by the local power supply utility Danger The absence of system component earthing can lead to serious injury from electric current if an electrical fault occurs. The appliance and pipework must be connected to the equipotential bonding of the building. Isolators for non-earthed conductors The mains isolator (if installed) must simultaneously isolate all nonearthed conductors from the mains with a minimum contact separation of 3 mm. If no mains isolator is installed, all non-earthed conductors must be isolated from the power supply by the upstream circuit breaker with a minimum contact separation of 3 mm. 26

Separate mains connection (cont.) E F Make the mains connection in accordance with the diagram. L1 C N D B D! Danger Incorrect core assignment can result in serious injury and damage to the appliance. Never interchange cores "L" and "N". Please note Incorrect phase sequence can cause damage to the appliance. Ensure phase equality with the Vitotronic control unit power supply. 40 A Colour coding to IEC 60757 BN Brown BU Blue GNYE Green/yellow A Mains connection, mixer extension kit B Vitotronic control unit power supply C Mains connection 1/N/PE, 230 V/50 Hz D Fuse (max. 16 A) E Mains isolator, two-pole, on site F Junction box (on site) Commissioning Heat source installation and service instructions 27

Commissioning (cont.) Rotational direction of the mixer motor Checking the rotational direction of the mixer motor After being switched on, the appliance implements a self-test. During this, the mixer is opened and closed again. Observe the rotational direction of the mixer motor during its self-test. Then manually set the mixer to "OPEN". Note The flow temperature must now rise. If the temperature drops, either the motor is turning in the wrong direction or the mixer insert is incorrectly fitted. Mixer installation instructions Changing the rotational direction of the mixer motor (if required) gs ~ BU 1. Remove the top casing cover of the mixer extension kit. Danger An electric shock can be life threatening. Before opening the boiler, disconnect it from the mains voltage, e.g. at the fuse or mains isolator. 2. At plug gs, swap the cores at terminals " " and " ". 3. Refit the casing cover. 28

Specification Rated voltage 230 V~ Rated frequency 50 Hz Rated current 2 A Power consumption Wall mounting 1.5 W Mixer mounting 5.5 W Protection class I IP rating IP 32D to EN 60529; ensure through design/installation Permissible ambient temperature Operation 0 to +40 C Storage and transport 20 C to +65 C Rated relay output breaking capacity Heating circuit pump sö 2 (1) A 230 V~ Mixer motor 0.2 (0.1) A 230 V~ Flow temperature sensor and return temperature sensor Sensor type NTC 10 kω, at 25 C IP rating IP 53 to EN 60529; ensure through design/ installation Permissible ambient temperature Operation 0 to +120 C Storage and transport 20 C to +70 C Curve 20 Resistance in kω 10 8 6 4 2 1 0.8 0.6 0.4 10 30 50 70 90 110 Temperature in C 29

Connection and wiring diagram A1 Mixer extension kit PCB F1 Fuse S1 Rotary switch 230 V~ plugs sö Heating circuit pump (on site) fö Mains connection 230 V/50 Hz föa Mains connection for accessories gs Mixer motor LV plug? Flow temperature sensor avg KM-BUS cable for connection to the Vitotronic control unit and KM-BUS cable for connection to another accessory 30

Declaration of Conformity Mixer extension kit (wall mounting and mixer mounting) We, Viessmann Werke GmbH & Co. KG, 35107 Allendorf, Germany, declare as sole responsible body that the named product complies with the provisions of the following directives and regulations: 2014/35/EU 2014/30/EU 2011/65/EU Low Voltage Directive EMC Directive RoHS II Directive Applied standards: EN 55014-1:2006+A1:2009+A2:2011 EN 55014-2: 2015 EN 60730-1:2011 EN 60335-1 2012 EN 60335-2-102: 2016 EN 62233:2008 In accordance with the following Directives, these products are designated with. Allendorf, 16 February 2017 Viessmann Werke GmbH & Co. KG Authorised signatory Manfred Sommer 31

Keyword index C Connection and wiring diagram... 30 D Declaration of Conformity... 31 E Electrical connections... 8 Extension kit mounting...5 F Flow temperature sensor Connecting... 9 Mounting...6 H Heating circuit pump connection 230 V~... 11 400 V~... 13 P Pumps Underfloor heating circuit...13 S Specification...29 T Temperature limiter... 14 U Underfloor heating circuit... 13 V Vitodens with Vitotronic 200...16 Vitoladens with Vitotronic 200...22 Vitopend with Vitotronic 200... 16 Vitoplus with Vitotronic 200...22 M Mixer motor connection...9 Viessmann Werke GmbH & Co. KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com 32 Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Subject to technical modifications.