USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Similar documents
Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

USER MANUAL Digital CO Monitor Model CO30

Indoor/Outdoor Temperature Alert

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

User's Guide. Pinless Moisture Meter. Model MO257

USER GUIDE Heat Index Psychrometer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USER MANUAL USB Multi-Function Datalogger Model RHT35

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

User's Guide. Pinless Moisture Meter. Model MO257

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Wet Bulb Thermo-Hygrometer Datalogger

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

User's Guide. CO 2 Monitor. Model CO200

4-in-1 Humidity, Temperature Airflow and Light Meter

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

User Manual. Humidity-Temperature Chart Recorder. Model RH520

TM-802 Formaldehyde Meter User s Manual

E1000 Portable gas detector

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Dual Laser InfraRed (IR) Thermometer

Portable type of Carbon Dioxide Detector Model: GT220

IMR IX176 Portable Gas Detector User Manual

IMR EX610. Portable Gas Detector. Operation Manual

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

High Temperature InfraRed Thermometer with Laser Pointer

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

GasAlertMicroClip X3 Specifications

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Introduction. OM-THA2

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Operator s Manual. 1, 2, 3, and 4-Gas Detector

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Bacharach Bodyguard 4 User's Guide

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

EVac II Programmable Digital Vacuum Gauge

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

ALTAIR 5X Multigas Detector Product Specification

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

QUICK REFERENCE GUIDE

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Specifications Minimum Typical Maximum Unit

Thermohygrometer with Single Type K Input and Superheat Function

DIGITAL KITCHEN SCALE

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Operator s Manual. 1, 2, 3, and 4-Gas Detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EasyLog Data Logger Series

MGC Dock User s Manual

Electronic Crimping Tools Operations Guide. Contents

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

MGC Dock User s Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

Manual Electrical Fire Alarm System

Oxygen Monitor Operating Manual

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Agilent Electronic Crimping and Decapping Tools Operating Guide. Agilent Technologies

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

CO2 Monitor Operating Instructions

Sirius MultiGas Detector

1.1 Definitions of alert icons. For your safety

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

Pocket CO2 Monitor & Data Logger SAN-0001

Notices. 2 Restek Corporation. Safety Notices

R2310. Infrared Thermometer. Instruction Manual

Digital Cooking Thermometer models / 00282

VALTRONICS IAQ Monitor

aura-t TP536/EU ventilation systems

Gas Measurement Instruments Ltd User Handbook

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Digital Thermometer with Ice Alert and Clock

Analog Room Pressure Monitor RPC Series

MODEL MR-720 FUNCTIONS AND CONTROLS SELF-POWERED AM/FM WEATHER BAND CLOCK RADIO

PERSONAL COMBUSTIBLE GAS DETECTOR

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

FUNCTION AND CONTROLS

Weather Station models / / 00524

Transcription:

USER GUIDE Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester Model VFM200

Introduction Thank you for selecting the Extech Instruments Model VFM200. The VFM200 measures HCHO (formaldehyde) and TVOC (Total Volatile Organic Compounds). This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Features Fuel Cell Formaldehyde Sensor Technology High accuracy measurements Backlit LCD display Real time display of HCHO (formaldehyde) concentration in air Real time display of TVOC (Total Volatile Organic Compounds) concentration in air Two unit selections (PPM, mg/m³) Audio visual High and Low Alarms Auto power off Description METER DESCRIPTION 1. HCHO sensor (front) 2. AC Adaptor jack (under flap). Down arrow and Alarm Setup button 4. Battery compartment (rear) 5. ON OFF button (also used in Alarm Setup) 6. Up arrow and UNIT selection button 7. Backlit Display 8. TVOC sensor (rear) 1 2 8 7 4 6 5 2 VFM200 en GB_V1.1 2/16

LCD DISPLAY 1. HCHO reading 2. TVOC reading. Selectable units of measure 4. Alarm Beeper symbol 5. Auto Power OFF reminder 6. Rechargeable Battery status 7. High and Low Alarm symbols Operation POWER THE METER Press the button to turn on the meter. The battery symbol informs the user as to the battery strength. Connect the battery charger to recharge the battery. Long press the button to power off. The LCD will count down:, 2, 1, then OFF before switching off. AUTO POWER OFF The meter will switch off after 0 minutes of inactivity. Press any function button to prevent the meter from powering off; the auto power off timer will be then be reset. The APO display symbol reminds the user that Auto Power OFF is always active. GERNERAL USE All LCD display lines will switch ON when power is applied to the meter. The bottom TVOC display will count down from 10 seconds or from 90 seconds (depending on the environment) to zero. When countdown is complete the meter is ready for use. In normal mode, the top display indicates the HCHO concentration in PPM or mg/m³. The bottom display indicates the TVOC concentration in PPM or mg/m³. Use the UNIT button to switch units between PPM and mg/m³. With the meter on, if the measured HCHO concentration exceeds the high or low userprogrammable Alarm thresholds, the LED display will flash red in color and the audible beeper will sound (unless it has been disabled with the SET/ button). Press SET/ to silence the alarm beeper (when it is sounding) or to disable the beeper entirely. When disabled, the displayed beeper symbol is switched off. ALARM SETUP (HCHO only) Low Alarm Setup 1. Long press the SET/ button to enter the setup mode. 2. The low alarm icon will display and the LCD will show the low alarm threshold.. Use the and buttons to adjust the low alarm threshold. 4. Press the button to go to the high alarm setup screen. High Alarm Setup 1. Use the and buttons to adjust the high alarm threshold. 2. Press the button to return to the normal measurement mode. 1 2 7 mg/m mg/m 6 5 4 VFM200 en GB_V1.1 2/16

CONTROL BUTTONS 1. Short press the SET button to silence the beeper (when it is sounding) or to disable/enable the alarm beeper. This button is also used as a down arrow to change the high and low Alarm threshold values in the Alarm Setup mode. 2. Long press the SET button to enter the Alarm Setup Mode (See Alarm Setup section).. Short press the UNIT button to change the unit of measure (PPM or mg/m³) or to use it as an up arrow to set the alarm threshold values in the Alarm Setup mode. SAFETY Do not store or use the instrument in an environment where corrosive gas is present. Do not obstruct the sensors when in use. Use only the supplied lithium ion battery to power the meter. Use only the supplied AC adapter/battery charger to charge the lithium ion battery. MEASUREMENT REFERENCE TABLE 0.0 ppm Average outdoor level 0.10ppm Recommended upper limit for residences by ASHRAE, ANSI, EPA, NIOSH 0.40ppm Recommended upper limit for manufactured homes 0.50ppm OSHA workplace limit 0.75ppm OSHA TWA limit 0.80ppm Level at which most people first detect odor 2.00ppm OSAL STEL limit BATTERY CHARGE and REPLACEMENT 1. When the battery requires charging, plug the supplied battery charger into the meter (left side, under flap) and to a source of AC power. A full charge requires 2 hours. 2. To replace the battery, open the rear battery compartment and replace the Polymer lithium ion battery (7.4V 100mAh). Re assemble the meter before use Battery Safety Notes: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end oflife devices to a designated collection point for the disposal of electrical and electronic equipment. CLEANING AND STORAGE Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solve nts. Please remove the battery if the meter is stored for a long period of time. 4 VFM200 en GB_V1.1 2/16

Specifications Sensor HCHO Range HCHO Resolution HCHO Basic Accuracy TVOC Range TVOC Resolution TVOC Basic Accuracy Response Time Operating Temperature Storage Temperature Power Supply Battery Charge Time Dimensions Weight Professional Fuel Cell technology 0.00 to 5.00 mg/m³ (or PPM) 0.01 mg/m (or PPM) ±5% FS 0.00 to 9.99 mg/m³ (or PPM) 0.01 mg/m³ (or PPM) ±5% FS 2 seconds 0 C to 40 C (2 to 104 F) 10 C to 60 C (14 to 140 F) Rechargeable Polymer lithium ion battery (7.4V 100mAh) Approx. hours with AC adapter 165 x 60 x 25mm (6.5 x 2.4 x 1.0 in.) 584g (20.6 oz.) Copyright 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 5 VFM200 en GB_V1.1 2/16