CURE ZONE 2 (#A )

Similar documents
CURE ZONE (#A )

EQUIPMENT OPERATION MANUAL. Loctite High Intensity Ultraviolet Source

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Loctite Zeta 7600 Ultraviolet Curing Conveyor Part Number EQUIPMENT Operation Manual

Model CWA200 Owner s Manual

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

1020 Industrial Drive, Orlinda, TN fax

SERVICE REQUIREMENTS

MF15 USER MANUAL

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Instruction Manual E4 ChamberIR Heater

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

Heat Management Methodology

Insta-Therm Series Service, Installation and Operation Manual

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

OWNER S MANUAL MODEL BW4B SLICER WARMER

ONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

PCO/UV N-Duct Model. Owner s Guide

THE MUG KING MUG PRESS

PRE INSTALLATION PROCEDURES

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Product Data Sheet. NeverStrip UV Resilient. Matte. A NeverStrip Instant Film Coating. UV Resilient Matte

TABLE TOP TEMPERER. with Digital Temperature Readout INSTRUCTION MANUAL

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

MODEL H HEAT SEALING MACHINES INSTRUCTION SHEET

MACHO POP Instruction Manual Model 2554EX, 2554BCX

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Distributed By: M&M Control Service, INC

Installation and Operation Manual

SimplyClear Pressurized Filter Product Manual

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Operation and Maintenance Manual. MNL /17/02 Rev. A MODEL 414

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Menumaster. Commercial Microwave Oven Use and Care Manual FS-8EVP FS-11EVP FS-16EVP

OPERATOR S MANUAL DEAD AIR WORKSTATION. AC600 Series Dead Air Box & Timed UV Light with UVTect Controller

SERVICING INFORMATION

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Part No Revised Nov Lil Max. Instruction Manual Model #2389, 2389EX

OPERATOR S MODEL CW-216 CW-114 DISPLAY COUNTER WARMER REGISTER WARRANTY ONLINE AT

MODEL 1308-C & 1308-N

Z-Stream Fog Machine User Manual English

Electronic 30 Watt UV-A Lamp Indoor

INSTRUCTIONS FOR OPERATION AND CARE OF

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Part No Revised: January Pop Maxx. Instruction Manual Models: 2552, 2552KC, and 2552LS

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Thermo-Sealer. Manual Heat Sealer. User Manual

FOR USE BY QUALIFIED PERSONNEL ONLY

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Installation Instructions Dual Fuel Ranges

Slide Warmer. Model XH-2001 Model XH Operating Manual

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Instructions for the 4-20mA Unit

BlueWave MX-275 Emitter User Guide Line Pattern Flood-Curing Emitters

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

Ultraviolet Crosslinkers

Part No Revised April Pop Maxx. Instruction Manual Model #2552, #2552C, #2552EX, #2552XJ

SERVICE REQUIREMENTS

OPERATING INSTRUCTIONS MIGHTYLAM 2700 ROLL LAMINATOR

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

Menumaster. Commercial Microwave Oven Use and Care Manual CFSP70 GSAND-7D SAND-7D SAND-700

en Indirect Lighting System LB 1 OPERATOR S MANUAL

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

FORM (October 2010)

C E B D N USER MANUAL H I P J K L /07 PRINTED IN P.R.C.

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

Ozone + UV Sanitation

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Greentrol Automation, Inc.

SPECIFICATION, INSTALLATION AND OPERATION MANUAL. Heat Lamp Assemblies. Models: W.HLA900, W.HLA1200 & W.HLA1500

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

4-GALLON MOBILE PARTS WASHER

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

SERVICE REQUIREMENTS

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Xenon Lamp Replacement Guide

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

SPECIFICATION, INSTALLATION AND OPERATION MANUAL HOT FOOD SLIDES ANGLED & FLAT SHELVES

SLT-Series Installation and maintenance instructions

Document No A3 Revised February Atlantic Ultraviolet Corporation

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

REV: 000. Lumitron/ Luminator

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

SECTION 3. OPERATING INSTRUCTIONS

Document No B1 February Atlantic Ultraviolet Corporation

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Transcription:

OPERATING MANUAL CURE ZONE 2 (#A001-051) UV FLOOD CURING SYSTEM 1229 W. Cortland St. Chicago, IL 60614 (800) 621-1296

CURE ZONE 2 UV FLOOD CURING SYSTEM OPERATING MANUAL INTRODUCTION...2 GENERAL DESCRIPTION...2 UNPACKING AND INSPECTION...3 INSTALLATION AND OPERATION...3 OPERATION...3 UNIT LAYOUT DRAWING FRONT VIEW...5 UNIT LAYOUT DRAWING SIDE VIEW...6 UNIT LAYOUT DRAWING REAR VIEW...7 UNIT LAYOUT DRAWING REFLECTOR HOUSING...8 SPECIFICATIONS...9 MAINTENANCE...9 SPARE PARTS...10 TROUBLESHOOTING...10 RADIOMETERS...11 UV SAFETY...11 CURE ZONE 2 OPERATING MANUAL PAGE 1

INTRODUCTION The UV (ultra violet) light system described in this manual is technically advanced. The UV light from this equipment is powerful. It is used with light sensitive resinous materials. These are cured or transformed from a liquid to a solid state by polymerization during light exposure. The most common uses are bonding, potting, coating and sealing. The range of materials and applications is extensive, spanning many industries and end products from electronics to automotive. Included are Polymer (plastic) coatings, adhesives and potting compounds. UV light generally should be used with care including eye protection to avoid exposure and injury. GENERAL DESCRIPTION The Cure Zone 2 UV light system is basic for a range of applications. Because of its simplicity of operation, it is well suited for initial use with UV responsive materials in laboratory or production circumstances. Using a medium-intensity flood light source, the Cure Zone 2 illuminates an 8- inch x 8- inch work area (64 square inches). It uses long wave (UVA) ultra violet light, moderate in strength. Major components are a power supply base, reflector housing with UV lamp, a full UV shield, adjustable work surface, connector cable and a power cord. To accommodate various-sized parts, the work surface can be positioned at three levels. It arrives set at the mid point. Two thumb screws at the back can be removed for adjustment. Alternate holes for the other two positions are capped with black plastic plugs which should be saved and reinserted. All adjustments to the work surface should be made with the equipment off and after having cooled to the touch. The support platen is covered by a special silicone rubber mat which resists UV deterioration and chemical attack. With use, it may soften and need replacement. For production or alternate use, the reflector housing can be separated from the base by removing screws at the sides and back of the housing. The reflector housing can be mounted or fixed over a conveyor for example. The 6' connector cable may be needed to accomplish this change. The hinged front cover with a UV filtering plastic door should be down for unit operation. UV light generally should be used with care, including eye protection, CURE ZONE 2 OPERATING MANUAL PAGE 2

to avoid exposure and possible injury. See setup and operating section for more detail. The work surface can be adjusted up or down to accommodate various size parts. Curing time will be minimized when the coating or bonding section of the part to be cured is positioned 1-2" from the lower edge of the reflector housing. Increasing the distance from the reflector housing will result in slower cure speeds. A glass filter substantially reduces any short and medium wave UV output. Operation of the Cure Zone 2 without the glass filter may cure some materials quicker and more tack free, however, extra UV protection may be required. Refer to section on UV SAFETY. UNPACKING AND INSPECTION Unpack the system and inspect it for shipping damage or missing components. Report damages, if any, to freight carrier. Save packaging for safe storage or future shipping. INSTALLATION AND OPERATION The CURE ZONE 2 will arrive completely assembled. All that is required is to plug in the connector cable and power cord, both are at the rear of the unit. The system should be positioned to allow at least a 6" clearance in each direction for adequate ventilation, as two fans at the top and right side discharge cooling air. Adjust work surface height so that material to be cured is 1-2" below lower edge of reflector housing. The work surface can be raised or lowered from the pre set mid-range position. Remove the two thumb screws at the back and relocate the work surface per the instructions in GENERAL DESCRIPTION. OPERATION To energize system, turn power switch on. Be sure UV glasses are being worn for eye protection. Wait 5 minutes for lamp to reach full power. The unit is now ready to use. The unit should be kept under power without frequent cycling. During use sequences, the lamp should be lit a minimum of 15 minutes at a time. After turning system off, allow 5 minutes for system to cool before relighting lamp (switch on again). Lamp life will be greatly enhanced if lamp cycling is kept to a minimum. It is suggested that the lamp is left on through work breaks. CURE ZONE 2 OPERATING MANUAL PAGE 3

UV light exposure to the part and material is controlled by the operator. A timing sequence and spacing must be developed for holding the work piece under the lamp. Once the cycle is established, the timing should be controlled by a timer if groups of similar parts are to be processed. It is best to work with the shield down. The reflector housing may be located remotely from the power supply. Remove the reflector housing by backing out the retaining button head screws. Use these holes and the adjacent set (see sketch), to mount the lamp reflector section over a conveyor or work station securely. A longer connecting cable may be needed. This can be purchased from Con-Trol-Cure. Be sure to allow adequate ventilation and UV shielding. Refer to section on UV SAFETY. No attempt to remove the reflector housing from the base should be made until the unit is switched off and the power cord is unplugged from the power source. CURE ZONE 2 OPERATING MANUAL PAGE 4

UNIT LAYOUT DRAWING FRONT VIEW CURE ZONE 2 OPERATING MANUAL PAGE 5

UNIT LAYOUT DRAWING SIDE VIEW CURE ZONE 2 OPERATING MANUAL PAGE 6

UNIT LAYOUT DRAWING REAR VIEW CURE ZONE 2 OPERATING MANUAL PAGE 7

UNIT LAYOUT DRAWING REFLECTOR HOUSING CURE ZONE 2 OPERATING MANUAL PAGE 8

SPECIFICATIONS Power input: 120 VAC, 60 Hz single phase, 8 amps max. Ultraviolet output: 80 mw/cm 2 of long wave, (UVA), ultraviolet energy illuminating an 8" x 8" (20cm x 20cm) cure area. Note: Intensity measured 2" (5cm) below reflector housing with a radiometer peak response at 365nm. Lamp Type: 400 Watt Metal Halide Power Supply Dimensions: 11.5"x10.0"x5.0"(29.2cmx25.4cmx12.7cm) Reflector Housing Dimensions: 9.5"x 8.25"x7.25"(24.1cmx21.0cmx18.4cm) Total Weight: 36 Pounds (16.4kg) MAINTENANCE The CURE ZONE 2 was designed to operate with minimum maintenance. Follow the schedule below to keep the CURE ZONE 2 in peak operating condition: A. GLASS & REFLECTOR Clean glass filter, if used, every 2 months or as required. Use isopropyl alcohol and a clean cloth. A hardly visible thin film of cured material can coat the glass filter reducing transmittance by as much as 30%. Clean reflector every 4 months or as required. Use isopropyl alcohol or glass cleaner and clean cloth. Remove filter glass by removing cap screws. Save and reuse Teflon washers. B. LAMP & SOCKETS Inspect lamp sockets for corrosion when replacing lamp. Replace lamp sockets if corroded. Heat generated by a poor connection can cause premature Lamp failure. Replace lamp every 1000 hours or as required to maintain adequate intensity for curing process. CAUTION Grip lamp at ends, not in the center when handling. Use a soft cloth, or cotton gloves if practical. If the lamp is touched in the center, remove fingerprints with isopropyl alcohol. C. WORK SURFACE PAD The special red silicone pad bonded to the support platen may deteriorate over time due to heat and resin contact. The pad is easily replaced. CURE ZONE 2 OPERATING MANUAL PAGE 9

SPARE PARTS *5185 Fuse, 8 amp Fast Acting *5157 Lamp Socket *5077 Lamp, Type AF Standard Lamp *±5478 Lamp, Type AH Special Lamp 5050 Power Switch 5159 Igniter 5220 6 Ft. Connector Cord (Extension) 5183 Work Surface Replacement Pad *RECOMMENDED SPARE PART ±Systems with non standard (Special) Lamps carry a sticker on the Reflector I- lousing which designates its type and part number (P.N.). TROUBLESHOOTING LAMP DOES NOT LIGHT, POWER SWITCH DOES NOT ILLUMINATE, FANS DO NOT START: check that power cord is plugged in check fuse in plug receptacle LAMP DOES NOT LIGHT, POWER SWITCH ILLUMINATES, FANS START: check lamp to be sure it is seated properly in lamp sockets lamp at end of life check that connector cord is properly plugged in at both ends inspect lamp sockets for evidence of excessive heat or arcing, lead wires may be burnt off UV OUTPUT LOW (READING FROM RADIOMETER): glass filter dirty lamp aged or defective reflector dirty radiometer defective or out of calibration ADHESIVE OR COATING DOES NOT CURE COMPLETELY: UV output low (see above) adhesive or coating does not cure with long wave UV light adhesive or coating needs higher intensity UV light to cure tack free adhesive or coating defective CURE ZONE 2 OPERATING MANUAL PAGE 10

RADIOMETERS A radiometer is a tool used to measure the output intensity of a light source. The intensity values listed in this manual were measured with a probe style radiometer with a 365nm probe. Intensity readings taken with a different radiometer should not be compared directly with the values in this manual. Radiometers from two different manufacturers can give readings that vary by more than 100%. Radiometers can be used to track lamp life and to determine acceptable intensities to ensure full cure within the curing process time frame. Radiometers are sold by: UV PROCESS SUPPLY 1229 W CORTLAND CHICAGO, IL 60614-4805 Tel: (773) 248-0099 Fax: (773) 880-6647 UV SAFETY The CURE ZONE 2 is a safe UV curing system when used properly. The system incorporates UV shielding and a non-reflective work surface. The guidelines below should be closely followed to ensure protection from the ultraviolet light: UV Protective glasses with side shields should be worn at all times. Potentially exposed skin should be covered. Long sleeve shirts and gloves should be worn when placing arms and hands under the UV light. Never look directly at the output from a UV lamp. WARNING: UV Energy is transmitted from the reflector housing. Protective eyewear equipped with side shields are required which meets ANSI Z80.3 certification. UV safety is the responsibility of the user especially when operating the CURE ZONE 2 in a nonstandard configuration. When in doubt about UV Safety, call UV PROCESS SUPPLY Technical Service before proceeding (773-248-0099) UV safety products and radiometers are sold by UV Process Supply. Contact us for recommendations or visit our website at www.uvprocess.com. CURE ZONE 2 OPERATING MANUAL PAGE 11