Centrifugal Blower. Backward/Aerofoil Curved.

Similar documents
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

The Advantages of Choosing Centrifugal Fans

A. Codes and Standards that are Standard at the University:

Selecting the Correct Fan

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Belt Driven Mixed Flow Fans

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA


Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

Industrial Fans & Blowers

Centrifugal Fans, Non-Overloading, Backward Inclined

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

EHH SERIES DRAW THROUGH FAN COILS CFM

Fans: Features and Analysis

Introduction to Fans. The Basics of Fan Principles and Terminology

an ISO 9001 Company Bulletin PR-112

Specially Designed Waste Water & Sewage Pumps

CAP SERIES SEWAGE AND WASTE WATER PUMPS

University of Houston Master Construction Specifications Insert Project Name

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

English CNA-CNB. Centrifugal fans Installation and maintenance

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION STEAM CONDENSATE PUMPS

Direct Fired Heater Model AD Specification

Bulletin FH05 FUME EXHAUST

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

R. K. Engg. Works Private Limited

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Fuji Electronic VFC 084P-5T

POWERPLUS SPP Product Brochure

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SOS Multi-Horsepower Outdoor Condenser Fan Motor

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

SECTION (15833) - HVAC POWER VENTILATORS

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

A. This Section includes air-handling units with coils for indoor installations.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

CR A-F-A-E-HQQE 3x400/ HZ

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Modular Supply Make-Up Air Unit

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Double Skin Air Handling Units

Understanding Fan System Effects

SELECTING A MOTOR MOTORS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

JM Aerofoil Fans Bulletin JMA60-05

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

ENGINEERING LETTER 4

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Ducted Propeller. Airflow Volume

CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS

CR A-F-A-E-HQQE 3x400/ HZ

What is the correct type of fan: Axial, radial, diagonal?

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION AIR HANDLING UNIT

SECTION FAN COIL UNITS

GreenJet Transfer Fans

TUNNEL FANS STANDARD AND HOT SMOKE

5 year fan housing and motor warranty

KCC Centrifugal Fan Air Cooled Condensers

SECTION CONVECTION HEATING AND COOLING UNITS

Evaluation Report 509

Indoor Air Quality. For assured. Double Skin Air Handling Units

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

1.1 This section applies to air handling units for HVAC Systems.

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Parts Washers, Water Pumps, special applications

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

MARLOW PUMPS RECIRCULATION

SECTION AXIAL FANS

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

KIC Air Curtains. Technical Guide

Tunnel Axial Flow Fan

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

Transcription:

Centrifugal Blower Backward/Aerofoil Curved www.humidin.com

Centrifugal Blower Backward/Aerofoil Curved When Quality Speaks For Itself As a leading manufacturer of Centrifugal Blower Backward/Aerofoil Curved`, today Humidin enjoys an enviable position in customer mind-space. Humidin boasts of a modern plant & a talented team of qualified professionals who sets an exacting standards of quality for themselves. In sum, Humidin stands for quality & customer satisfaction that are instrumental in bringing them on par with what the world calls the world class.

Centrifugal Blower Backward/Aerofoil Curved Double/Single Inlet Backward/Aerofoil Curved Centrifugal Blower The Centrifugal Blower (Backward/Aerofoil Curved) consist of Double Inlet Double Width (DIDW) centrifugal fans. These fans have Backward/Aerofoil curved impellers h aving special profile to give you maximum efficiency at low noise levels. These impellers are statically and dynamically balanced. The fans are suitable for various applications, where high volume air displacement is required like Air Cooling, General Ventilation, Pressurization etc., in commercial process and industrial HVAC systems Available Sizes : The series is available in wheel size 500 mm to 1400mm diameter. TYPE HUMIDIN Centrifugal series fans are designed for various duty application and are available in various type of construction, however, here in this catalogue, we shall present only type-a TYPE - A The Centrifugal series is available in type A where strong side frame (M.S.) in welded construction are provided to support the Bearing and for wheel assembly Fan size : 500 to 1400 3 Volume : 4,000 to 1,50,000 m/h Total Pressure : 100 Pa to 2000 Pa www.humidin.com 1

Centrifugal Blower Backward/Aerofoil Curved IMPELLER HUMIDIN Centrifugal Series impellers have Backward/Aerofoilic curved blades manufactured in MS steel sheet. The blades are die formed. The Impellers are statically and dynamically balanced to ISO 1940 and AMCA 204-G2.5 standards CASING The casing for all sizes is manufacuted in GI/MS steel sheet. Up to 1000 dia G.I. & beyond 1000 dia in MS. SIDE SUPPORTING FRAME (MS) The side supporting frames are fabricated out of MS section steel. The surface is finished with enamel/ epoxy coatings. GRINDED SHAFT The shaft used for the fan are made of EN-8/SAE-1040 carbon steel and machined to the prescribed tolerances with standard keyways. The Shaft are grinded for better performance and finish. The Shafts are coated with Varnish/Laquer after assembly. BEARINGS HUMIDIN Backward curved blower have bearings of international standard. The Bearings are either deep groove ball bearings or spherical roller bearings with accentric locking collars/adaptor sleeve sealed at both sides. The Bearings are prelubricated and are maintenance free. INLET CONE The Standard Inlet Cones are made of FRP, however for bigger sizes the fabricated Inlet Cones, made of sheet steel material are provided. The Inlet Cones are designed Aerodynamically for better efficiency. ACCESSORIES Drain Plug in casing - optional. Outlet Flanges - optional. Inspection Doors - optional (one position). Guards at Inlet or outlet are optional www.humidin.com 2

Centrifugal Blower Backward/Aerofoil Curved Fan Rotation and Discharge The rotation and discharge of the fan is in accordance with AMCA standard 99-2406-03. The direction of rotation is determined from the drive end of the fan CW CCW - clockwise rotation - counter-clockwise rotation 90 180 270 360 CW CCW Fan rotation and discharge Motor Selection The power curve shown on each performance curve represents the absorbed power at the shaft of the fan measured in kw. To determine the power of the motor to be installed, a correction factor should be applied to compensate for transmission losses. Motor Position The position of the motor for belt drive centrifugal fan is in accordance with AMCA standard 99-2407-03. Location of motor is determined by facing the drive side of fan and designating the positions by letters W, X, Y & Z. For conversion to horsepower (HP), use multiplying factor 1.34. 100 80 Correction Factor, % motor power outpur 60 40 30 20 15 10 8 6 4 3 2 Pole 4 & 6 Pole W 2 1.5 1 0.2 0.45 0.6 0.75 1.5 2.2 3 4.5 6 7.5 15 22.5 30 Motor power output (KW) 45 60 75 Recommended for compensation 150 225 300 450 Z Y X Motor Position www.humidin.com 3

4

The intention of this brochure is to introduce you to, and acquaint you with the capabilities of the HUMIDIN organization in the offered product areas. It will not answer all your immediate questions, and indeed, it will no doubt raise others. We welcome your interest in our products and shall be very pleased to provide further information. GUARANTEE HUMIDIN guarantees its products to be free of defects in materials and workmanship for a period of one year from the date of delivery from the factory, provided motors are properly installed with overload protector. Humidin agrees to repair or replace defective parts or part to be returned to the factory, all transportation charges prepaid. Humidin does not guarantee against abrasion, corrosion or erosion. Humidin shall not be held responsible for any charges in connection with the removal or replacement of alleged defective equipment nor for incidental consequential damages. In accordance with our policy of continual improvement in design, we reserve the right to depart from the details given in this brochure. A.C. HUMIDIN AIR SYSTEMS PLOT NO: B-6, SECTOR: A-3 UPSIDC, TRONICA CITY, LONI- 201102 U.P. INDIA PH. 0120-2696683, 2696684 FAX 0091-120-2696677 Email: info@humidin.com