DIAPHRAGM VACUUM PUMPS

Similar documents
DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18

CUSTOMIZED PUMP SOLUTIONS FOR DOD AND CIJ PRINTING SYSTEMS

MEMBRAN-DIAPHRAGM LIQUID PUMPS

Multi-User Vacuum Systems for up to ten Users LABOBASE

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

Diaphragm Vacuum Pumps

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

Recirculating Cooler C 900

Vacuum Pumps for moist Gases. Self-drying Vacuum Pump for moist Gases. Series LABOPORT SD N FT Vacuum Pump. Spare parts.

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Laboport Chemically-resistant Laboratory Pumps and Systems

6-2.1 ANKERSMID Diaphragm pump Application No contamination of the media AMP 510/518/530 due to oil-free operation Low maintenance

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Vacuum Controller with Control Unit VC 900

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

For more information on Tarkett go to

Accuracy counts! Sensors with analog output

Intelligent. Powerful.

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Vacuum pump systems. Operating Instructions Read and observe these Operating Instructions! SC 950 SEM 950 SH 950 SR 950

Beckhoff short profile

IWAKI HI-CERA PUMPS V

maxium smart Vac The innovative system for efficient smoke evacuation

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

SHAKING WATER BATHS ENGLISH

The best in connector value... today, tomorrow and into the future!

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Series. Unique PCB mounting system.

A New Generation of Two-Stage Rotary Vane Pumps!

CRA24-B3 controlled residential ventilation

HazLoc Essential Guides:

MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

Expansion vessel in a solar installation. White paper

KNX The worldwide STANDARD for home and building control. KNX Association International

AERO 20 AERO ENGLISH - Operating Instructions

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Return loss measurement of fiber optic components

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

PCMini52 Digital RH & Temperature Mini Probe User s Manual

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

DESCRIPTION FEATURES WARNINGS APPLICATIONS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

KNX The worldwide STANDARD for home and building control. KNX Association International

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Hydra-D. Ultra-high purity desiccant air dryers. Engineering GREAT Solutions

Cable sealing solutions. for hazardous areas

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Instruction Manual. Mink. Claw Vacuum Pumps MM 1402 AV, MM 1502 AV. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D

Instruction Manual PB 0003 D. Rotary Vane Vacuum Pumps. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

MX Series (MX-70 & MX-100) Instruction Manual

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation.

Premium freezers combining functionality, elegance and energy efficiency

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Vacuum Pump System, the New Generation SC 950 Vacuum Pump System with wireless remote Control, speed regulated

maxium smart Vac The innovative system for efficient smoke evacuation

FieldLink Cable solutions for Automation & Drives

MTL1000 range of signal conditioners. For reliable, high quality process communications

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation.

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

marvac The innovative system for efficient smoke evacuation

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

STANDARD T6 (200 C) SENSOR CABLE RANGE

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

PTG, SWT Series. Heat Recovery Systems

Rain Forest Quick Guide

a clear edge Solutions for Industrial Processes Mid-Range Dry Vacuum Pumps Vacuum science... product solution.

Spray Rinse & Steam Handling

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Transor Compact Filter. Filter of a new generation

HydroSpeed plate washer for 96- and 384-well formats

Series. Robust and attractive.

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

micropac. Personal Gas Detection Instruments

Instruction Manual. Puma. Vacuum Booster WP 4500 B. Ateliers Busch S.A. Zone industrielle, 2906 Chevenez Switzerland

Instructions for use Vacuum regulation valve with water trap

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Rotary Screw Compressors SXC»Compact«Series. With the world-renowned SIGMA PROFILE FAD 0.26 to 0.8 m 3 /min, Pressures bar

Transcription:

DIAPHRAGM VACUUM PUMPS FOR THE STERILIZATION AND DRYING DATA SHEET E180 N 836 APE, basic model N 836.3 AP.40 E, with magnetic valve Concept The one and two-headed Diaphragm Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The pumps are equipped with the patented stress-optimised structured diaphragm, resulting in a high pneumatic performance, a durable product and compact size. Special valves ensure that the product can cope easily with vapour and condensation. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of durability. Various AC motors are available for pump drive. Features Uncontaminated flow No pollution of the media Maintenance-free Patented pump system for autoclaves Various technical options: - The low-cost model - The model with integrated magnetic valve for automatic rinsing - With additional cooling of the pump heads for vapour conden - sation and connection for water cooling, please contact us for more details. Very high vapour and condensation compatibility High level of gas tightness Long product life Negligible current loss Areas of use The diaphragm vacuum pumps, with their high level of performance despite their compact size, combined with patented technology and an excellent price to performance ratio, are used especially in autoclave systems (vacuum sterilisation) and dry cabinets (vacuum drying). The pumps suck out air, gases and vapours and in so doing evacuate for example containers or chambers of autoclave system. PERFORMANCE DATA TypE Delivery atm. Pressure Weight (l/min) (mbar absolute) Press. (bar g) (kg) N 836 APE 31 80 0.5 4.85 N 836 AP.40 E 31 80 0.5 4.95 N 836.3 APE 31 10 0.5 7.1 N 836.3 AP.40 E 31 10 0.5 7.2

N 836 APE N 836 AP.40 E Model with automatic rinsing (l/min) (bar g) () N 836 APE 31 0.5 80 (l/min) (bar g) () N 836 AP.40 E 31 0.5 80 Power P 1 (W) 80 Operating current (A) 0.45 Power P 1 (W) 80 Operating current (A) 0.45 5) Oxidised on the outside and coated on the inside 4) Phillips Petroleum registered trade mark 3) See also MODEL CODES FOR EASY ORDERING Dimensions 6) (mm) 4 mm deep direction of rotation 4 mm deep direction of rotation spade connector 2.5 x 0.8 for aeration valve (24 V dc) 6) All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V () ()

N 836.3 APE N 836.3 AP.40 E Model with automatic rinsing (l/min) (bar g) () N 836.3 APE 31 0.5 10 (l/min) (bar g) () N 836.3 AP.40 E 31 0.5 10 Power P 1 (W) 100 Operating current (A) 0.6 Power P 1 (W) 100 Operating current (A) 0.6 only at motors with 100 V and 115 V M4 (4x) 4 mm deep only at motors with 100 V and 115 V direction of rotation M4 (4x) 4 mm deep () ()

TECHNICAL INFORMATION Pump down time for 10 l receiver N 836 APE MODEL CODE FOR EASY ORDERING The model code is identical to the order number. It is made up as follows: N 836.3 AP.40 E 230 V/50 Hz, IP 00 Base model Head connections Head materials Technical options, e.g.: Pump head with automatic rinsing Version with ac motor Other motor data e.g.: In addition the motor data must be given in the purchase order (voltage, frequency, and protection class). In our extensive program you are sure to find the pump you need for your particular application. Pump down time for 10 l receiver N 836.3 APE TECHNICAL DETAILS Maximum permissible gas and ambient temperature: between +5 C and +40 C. Versions for higher gas temperature and with motors for other voltages, frequencies and protection classes on request. KNF - the competent partner for vacuum and compressor technology. Especially for unusual problems. Call us and talk to our application engineers.

HINTS ON FUNCTION, INSTALLATION AND SERVICE FUNCTION OF KNF DIAPHRAGM VACUUM PUMPS AND COM- PRESSORS An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Diaphragm pump HINTS ON INSTALLATION AND OPERATION Range of use: Transfering air, gases and vapours at temperatures between +5 C and +40 C. Versions for higher temperature on request Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors - please contact us. Permissible ambient temperature: between +5 C and +40 C. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program - please ask us for details. The pumps are not designed to start against pressure or vacuum; when a pump is switched on the pressure in the suction and pressure lines must be atmospheric. Pumps that start against pressure or vacuum are available on request. To prevent the maximum operating pressure being exceeded, restriction or regulation of the air flow should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in sufficient cooling air. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump - that prolongs working-life. HINTS ON SERVICE The diaphragm and valve plates are the only parts of the KNF diaphragm pumps subject to wear. They are easy to change, as no special tools are needed. If you have any questions, please call our application engineers (see below for contact telephone number). KNF Neuberger GmbH Diaphragm Pumps + Systems Alter Weg 3 D-79112 Freiburg Tel. ++49 (0)7664/5909-0 Fax ++49 (0)7664/5909-99 E-mail: info@knf.de www.knf.de KNF reserves the right to make changes O 11/2012 Printed in Germany

YOUR LOCAL PARTNER AROUND THE WORLD KNF SALES ORGANIZATION Australia KNF Regional Office Moreland West VIC 3055 Tel. +61 3 9386 4959 info@knf.com.au www.knf.com.au Benelux Netherlands KNF Verder B.V. 3451 GG Vleuten Tel. +31 30 677 92 40 info@knf-verder.nl www.knf-verder.nl India KNF Pumps + Systems (India) Pvt. Ltd. Hinjewadi Pune 411 057 Tel. +91 20 640 13 923 info@knfpumps.in www.knfpumps.in Italy KNF Italia S.r.l. 20063 Cernusco s. Naviglio (MI) Tel. +39 02 929 04 91 info@knf.it www.knf.it Singapore KNF Regional Office Tel. +65 9722 1994 info@knf.com.sg www.knf.com.sg Sweden, Finland, Denmark, Norway KNF Neuberger AB 117 43 Stockholm Tel. +46 8 744 51 13 info@knf.se www.knf.se Benelux Belgium and Luxemburg KNF Verder N.V. 2630 Aartselaar Tel. +32 3 871 96 24 info@knf.be www.knf.be China KNF Technology (Shanghai) Co., Ltd. Shanghai 201203 Tel. +86 21 5109 9695 info@knf.com.cn www.knf.com.cn France KNF Neuberger SAS 68128 Village-Neuf Tel. +33 389 70 35 00 info@knf.fr www.knf.fr Germany KNF Neuberger GmbH 79112 Freiburg Tel. +49 7664 5909 0 info@knf.de www.knf.de Japan KNF Japan Co. Ltd. Tokyo 104-0033 Tel. +81 3 3551 7931 info@knf.co.jp www.knf.co.jp Korea KNF Neuberger Ltd. 135-502 Seoul Tel. +82 2 959 0255 knf@knfkorea.com www.knfkorea.com Latin America KNF Regional Office Tel. +1 609 649 1010 gb@knf.com www.knf.com/es Morocco, Tunisia, Algeria KNF Neuberger SAS 68128 Village-Neuf Tel. +33 389 70 35 00 info@knf.fr www.knf.fr Switzerland KNF Neuberger AG 8362 Balterswil Tel. +41 71 973 99 30 knf@knf.ch www.knf.ch UK, Ireland KNF Neuberger U.K., Ltd. Witney, Oxfordshire OX28 4FA Tel. +44 1993 77 83 73 info@knf.co.uk www.knf.co.uk USA, Canada KNF Neuberger, Inc. Trenton, NJ 08691-1810 Tel. +1 609 890 8600 knfusa@knf.com www.knfusa.com KNF PRODUCT CENTERS Gas Pumps KNF Neuberger GmbH DE-79112 Freiburg info@knf.de www.knf.de Micro Gas Pumps KNF Micro AG CH-6260 Reiden info@knf-micro.ch www.knf-micro.ch Liquid Pumps KNF Flodos AG CH-6210 Sursee info@knf-flodos.ch www.knf-flodos.ch