Grass Sensotronic Planning Guide

Similar documents
NOVA PRO - the complete drawer system with precision and individuality.

NOVA PRO drawer system

MOVEMENT SYSTEMS. MAKE THE SIMPLE ACT OF OPENING A DRAWER OR CUPBOARD A LUXURIOUS EXPERIENCE.

SENSOMATIC OPENING SYSTEM

Assembly instructions

Intelligent. Powerful.

TANDEM plus BLUMOTION

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

Industrial Fire Detection

Functional built-in waste management

NOVA PRO SCALA. INSPIRATION IN THE RIGHT ANGLE. SIMPLE. CLEAR. TIMELESS.

VIONARO drawer SYSTEM

Reliability as a matter of principle: Quadro drawer runners for wooden drawers with drawer side profile thickness up to 19 mm

Bagless upright vacuum

Renova Nr. 1 Comfort. Gain personal freedom.

TECHNICAL INFORMATION Touchtronic Clothes Dryers

A cast iron case for our modular motors: High-voltage motors H-compact PLUS

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

4 Storage cabinets SCALA

GRASS DRAWER SYSTEM NOVA PRO SCALA. Inspiration in the right angle. Simple. Clear. Timeless.

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

INSTALLATION INSTRUCTIONS

Bagless upright. Vax Careline (UK) (ROI) vax.co.uk VS-19EC. Vax model number:

Bagless upright. vax.co.uk. Vax Careline: (UK) (ROI) VS-190 Series. Vax model number: Version 1.1

Scrubber driers compact BR 40/10C

U88-T2-B. User Guide. Bagless Upright. Get Cleaning... vax.co.uk. U88-T2 series. What s your Vax model number? (Located on the flap of the packaging)

Office furniture perfectly organised: New Systema Top 2000 products

Modular storage space terri tory

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

MC-UL Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

HEKO, to give shape to your projects SINCE 1984 HEKO FOLLOWS A PATH SEARCHING FOR THE MOST ADVANCED AND INNOVATIVE TECHNOLOGIES.

Installation Instruction Devidry - for installation with Devidry Pro Kit

2.2. Type 90. Safety cabinets for active storage of drums

Hettich. ArtCube. Top-drawer expertise

urbankitchen European Quality with a Local Price Tag connect.blum.com

Installation instructions Side-by-Side combinations

V-LINE The new formula for the storage of hazardous materials

INSTALLATION INSTRUCTIONS

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Let s get started. vax.co.uk U86-AL-B REGISTER YOUR 6 YEAR GUARANTEE. VISIT VAX.CO.UK/GUARANTEES

EVOlution comes from tradition

TECHNICAL INFORMATION T1500 Series Clothes Dryers

DOUBLE DISHDRAWER TM DISHWASHER

Kitchens industrially made to measure

GRASS PRESSEINFORMATION»Tiomos«März 2011

Security, Efficiency and Comfort with KNX

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

DOUBLE DISHDRAWER TM DISHWASHER

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner

EVOlution comes from tradition

Gaggenau en Planning aid. Vario. Cooling 400 series

Installation instructions Refrigerators and freezers for integrated use, door-on-door

CombiBloc Close-coupled centrifugal pumps

LIMITED METAL WARRANTY

The new SOLOLIFT2 means goodbye to dirty hands

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ)

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

THE ORIGINAL SHOWER TOILET

Grohtherm Wireless! Installation Instructions Pumped

Multi Function Food Processor

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Astro Express 2 - Hot Water Delivery System

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

SERVO-DRIVE flex. For electrical opening of handle-less, integrated refrigerators, freezers & dishwashers.

MODEL 5100 VOTING LOGIC MODULE

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

INSTRUCTION MANUAL Vacuum Cleaner Model No.: VB-100

+44 (0) Security for your POS Metal drawer from ANKER

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

The versatile drawer system for first-class design and convenience in the bathroom: InnoTech

INSTALLATION INSTRUCTIONS

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

457LAVEXDM15 DUAL MOTOR HEPA UPRIGHT VACUUM CLEANER

4 STEPS TO YOUR NEW KITCHEN Planning guide 2018

Single Cyclonic Cylinder Vacuum Cleaner

BR 40/10C. Professional heavy-duty scrubber dryer makes light work of dirty floors. Powerful and fast. Service-friendly. Ergonomic handle.

Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner

BR 40/10C. Professional heavy-duty scrubber dryer makes light work of dirty floors. Powerful and fast. Service-friendly. Ergonomic handle.

NEW

More quality of motion for your furniture.

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer,

Installation Instructions Component Systems Professional Line

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

Isco 3700ZR Sampler. Manual Set

BARBECUE ISLAND ACCESSORIES

TECHNICAL INFORMATION T 15xx Dryers

MODULAR COOKING EVO700

What to expect from your water softener

Installation instructions

Privacy Wall - Solid and Glass Wall Panels Cornice Application

BATHROOM TRENDS - October 2017 INTERNATIONAL COMPARISON. Overview of bathroom trends in Houzz Inc.

VX31 vax.com.au vax.co.nz

Kitchen Layouts L Shape Kitchen

FRIDGES AND FREEZERS COMBINED. EFC-2033 NF EX p. 108 EFC-2032 NF EX p. 109 EFC-2032 NF WH p. 109

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Transcription:

Planning Guide The star in your cabinet

Planning Guide. The beauty of ergonomics Ergonomics is the trend, just like elegantly simple handle-free furniture fronts. Grass Senso - tronic supports both of these trends. Drawers, pull-outs and interior pull-outs open and close in response to a gentle tap. They move different loads of up to 70 kg uniformly open and shut at the set speed. This assistance in the kitchen is particularly helpful when you consider that stored items are accessed up to 10,000 times a year. And the drawers think with you: they sense resistance and stop, avoid collisions amongst themselves and protect against nip injuries. Intelligence moves. And yet it s so simple. In installation and operation alike. 2

Sensotronic Performance features: The drawer can be opened by tapping or pulling; a gentle nudge is sufficient The door is closed by tapping Tapping determines the direction of travel, the drawer automatically performs the movement no effort is required (in contrast, electromechanical solutions do not have powerassisted closure) Can be used with or without handle (the drawer reacts in accordance with the application) Blockage recognition over the entire distance in both directions Anti-collision protection (no collision of drawers e.g. in the case of diagonal corners); drawers can communicate with one another Drawer follows a speed profile: Uniform opening and closing speed irrespective of drawer weight Transport-assisted solution (heavy loads are moved by a drive over the entire distance in both directions). Soft stop at end position: When opened, the drawer moves softly into its end position Cushioned closure: Drawer closes softly Optimal side stability Interior pull-out logic: Interior pull-out stops before reaching the extended pull-out and can be closed again by tapping the pull-out Position initialisation: Depth adjustment for perfectly aligned fronts Integration of optional accessories such as lighting is possible 3

System Description Drawer. The cabinet member Each cabinet member is equipped with a drive which determines the speed profile and the opening length. In addition, the drive reacts to blockages, pressure, pulling, etc. Lengths range from NL 270 to 650 mm. From nominal length 400 mm upwards, cabinet members can bear a load of 70kg. The screw positions remain the same as for the standard Nova Pro cabinet member. As the drive is fitted to the rear end of the cabinet member, an additional installation depth of 79 mm is required. Inside cabinet depth: nominal length + 79 mm. The depth of the left and righthand cabinet members can be adjusted on the respective cabinet member in order to achieve properly aligned fronts The drive shaft The drive shaft synchronises the left-hand with the right-hand cabinet member. The rigid connection ensures perfect side stability even in the case of wide pull-outs. If necessary, the drive shaft can be cut to size for special widths. Drive sleeves must be ordered separately. The wiring Vertical cable Every drawer requires a vertical cable to supply power to the cabinet member drive. It connects a power supply unit and / or distributor with the first cabinet member and each cabinet member with the next within a cabinet. Horizontal cable A horizontal cable connects one cabinet with the next. It starts from the power supply unit and runs to the adjacent distributors, then on to the next distributor in each cabinet. Power cord The power cord is available with the respective plug type for the country in which it is to be used and is approx. 2 m in length. 4

System Description Elektronics. The power supply unit The power supply unit is required to supply Sensotronic with power. It contains the busmaster and thus the system intelligence. For up to 22 drawers (without lighting) or 15 drawers (with lighting), you will only need one power supply unit. If you wish to use more drawers, you will need another unit. To prevent a noticeable drop in power, the greatest distance between the power supply unit and any one cabinet member should not exceed 5 metres. An installation height (must be installed in an upright position) of 23 cm is to be envisaged. The power supply unit can be used worldwide. Only the power cord has to be ordered for the specific country. The distributor You will need one distributor in each cabinet where there is no power supply unit. The distributor is used on the one hand to serve all the cabinet members in the cabinet and on the other to connect the horizontal cable to the next cabinet / distributor. The dongle Once the kitchen has been installed, the system has to be configured. Configuration turns the standard kitchen into a convenient and intelligent kitchen. The dongle is required for this operation. It is a kind of electronic key which is provided with every kitchen and which tells the busmaster that the configuration is being performed is plugged into a vacant slot in the horizontal wiring (power supply unit or distributor) during this operation and then removed again afterwards makes configuration possible for anyone (also after moving house) 5

The Planning. Notes for cabinet planning Provide switchable power outlets (e.g. to allow the user to switch the system off when going on holiday or cleaning the drawers). Required inside cabinet depth: NL + 79 mm (see range overview for plannable slide lengths) Use Sensotronic for modern furniture planning and incorporate fronts which are flush with the cabinet sides. Determine the depth of the cabinet sides on the basis of the front thickness used and the largest front gap defined for the cabinet. Front gap with Sensotronic To ensure reliable activation when opening the drawer by tapping, an activation distance of 3 mm is required. This gives a front gap (space between drawer front and front edge of cabinet) of 3 mm. The activation zone encompasses the full width of the front. Depending on the stability of the pull-out and/or the rigidity of the front, it will be possible to tap at different heights with a front gap of this size. Front buffers will enlarge the front gap. The drawer The screw positions of the cabinet member are the same as on the standard Nova Pro cabinet member. Special applications where there is resistance for either the opening or closing operation cannot be used with the standard software (e.g. waste disposal pullouts with lift-up lid, some plinth drawers, backward sloping slides, etc.). For a selection of waste sorting systems currently suitable, please refer to page 11.. Cabinet member Drive shaft Vertical cable Horizontal cable Power cord Power supply unit Distributor Dongle 6

Notes on the electronics The power supply unit The power supply unit should be placed near a power outlet (power cord length approx. 2 m). It can be used worldwide. Only the power cord must be ordered for the specific country. Please note the range of the power supply unit of approx. 5 m and the number of cabinet members which can be connected (see System Description). If separate cabinet blocks are planned (e.g. cooker island), one power supply unit per cabinet block is recommended. For safety reasons, the power supply unit must not be fitted beneath a sink. An installation height (must be fitted upright) of 23 cm is to be provided. Mains connection: Voltage supply: 90 240V Mains frequency: 50 / 60 Hz Max. output: 240 W Other notes Neither the drawer nor the cabinet member is energized. All live parts are fully enclosed and inaccessible. In the event of a power outage, the drawers can be opened and closed conventionally. Needless to say, all the data entered when configuring the system are retained in the case of a power outage. Operating conditions: Temperature: +/- 0 to +50 C Humidity: 15% to 90% 7

Breakdown of Parts List. Example 900 900 900 296 296 146 (1) VC DS PC DR HC PSU (1) VC HC DR 210 210 210 D (1) VC (min) = 350 mm (min) = Front height - 40 mm Ordering example Number in pcs. / pairs Order No. Cabinet members (e.g. NL 500) 9 69718-04 DS Drive shafts 9 70053-04 Drive Shaft Connector 18 68528-39 VC Vertical cable 9 70073-04 PSU Power supply unit 1 68518-04 DR Distributor 2 68519-04 HC Horizontal cable (L: 1200 mm) 2 70062-04 PC Cord for PSU 1 see table for country-specific power cord D Dongle 1 70000-04 8

Overview of Range. Sensotronic cabinet members () Nominal length for side height 90 mm 270 mm (40 kg) 69700-94 300 mm (40 kg) 69703-94 350 mm (40 kg) 69706-94 400 mm (70 kg) 69709-94 450 mm (70 kg) 69712-94 500 mm (70 kg) 69718-94 550 mm (70 kg) 69721-94 600 mm (70 kg) 69724-94 650 mm (70 kg) 69727-94 PU = 1/4 Drive Shafts (DS) Ord. No. 600 mm 70051-04 800 mm 70052-04 900 mm 70053-04 1000 mm 70054-04 1200 mm 70055-04 PU 10 Drive Shaft Connector 68528-39 PU 20 Electronics Power supply unit (PSU) PU 1/10 68518-04 Distributor (DS) PU 10 68519-04 Dongle (D) PU 1/10 70000-04 Wiring vertical (VC) 200 mm 70071-04 250 mm 70072-04 350 mm 70073-04 450 mm 70074-04 650 mm 70076-04 horizontal (HC) COW 900 mm 600 mm 70061-04 1200 mm 900 mm 70062-04 1500 mm 1200 mm 70063-04 3000 mm 70065-04 PU 10 Country-specific power cord (Pc) Countries (examples) K USA 69760-04 A D, ES, F, NL, RUS 69761-04 E DK 69763-04 I Italy 69764-04 L Suisse 69765-04 D UK, UAE, IRL 69766-04 Power cord without plug 69767-04 PU 10 K E L A I D 9

Planning Guide at a Glance. For the cabinet and drawer Provide switchable power outlets Inside cabinet depth: NL + 79 mm Minimum carcass width 550 mm (if the power unit is installed in the carcass) Use flush fronts Choose the required front gap for compatibility with other touch-latch systems Activation distance: 3 mm Adjustment range: up to 6 mm When using Nova Deluxe height 122 mm (P930), take the additional information for this version into account The screw positions for the cabinet member are the same as for the standard Nova Pro cabinet member Special applications (e.g. with opening and/or closing resistance, backward sloping cabinet members) are not possible For the electronics The power supply unit can be used worldwide Power cord length of 2 m from power supply unit must be taken into account Include country-specific power cord when ordering Power supply unit has a range of 5 m up to the last connected cabinet member without loss of performance Up to 22 drawers can be connected to one power supply unit If the stated range is exceeded or if the kitchen layout includes an island, an additional power supply unit must be provided Do not position the power supply unit in the sink cabinet Plan an installation height of 23 cm for the power supply unit (install with cordless screwdriver) The power supply unit must be fitted in an upright position Operating conditions Temperature: 0 to +50 C Humidity: 15% to 90% 10