Minimize Shrink from Grain Drying and Aeration

Similar documents
QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Grain and Soybean Drying on Georgia Farms

Aeration vs NAD vs NAD+heating vs Heated Air Drying

Grain Handling, Drying and Storage Management

Low-Temperature Drying of The 1992 Indiana Corn Crop. Dirk E. Maier, Agricultural Engineering, and Richard L. Stroshine, Agricultural Engineering

Estimated Corn Field Drying

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

OPI-integris Advantages

Task Force. Rewarming Supercold Grain. Dirk E. Maier, Agricultural Engineering

Drying and Cooling Stored Grain and Preserving its Quality

Aerating Grain in Storage

The following table summarizes information from various sources on corn development.

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

CC196 Guide for Batch-Drying in a Bin

CC197 Guide to In-Storage Drying with Supplemental Heat

9 - On Farm Storage and Drying

Post-Harvest Management: The Economics of Grain Drying

Reducing Energy Use in Grain Dryers

Aerating Farm -Stored Grain

Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, Bob Marlow, The Andersons, Inc

Selecting Fans and Determining Airflow for Grain Drying and Storage

Cross-flow drying - Introduction. Cross-flow drying research goals. Cross-flow drying - Introduction. Mathematical Modeling: Possibilities

Why is it essential to measure moisture in stored crops, such. Why is it important to measure multi point and in-sitú in the storage silo?

AE-701 (Revised), November Dr. Kenneth J. Hellevang, PE Extension Agricultural Engineer

INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER

Monitoring Natural Air Corn Drying A Demonstration Project

This circular is issued in cooperation with the Economic Research Service, U.S. Departmenf of Agriculture.

Applying Technology for Agriculture

i ;, ct. 6 COSTS OF DRYING AND STORING SHELLED CORN ON ILLINOIS FARMS I_(t e_

EasyDry. Grain Drying Systems

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

Grain Dryer Efficiency. Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc th Street Rockford, IL 61104

EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE

CC196 Revised with no date Guide for Batch- Drying in a bin

EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE

Setting Your Bullseye to Control Your Fans

Seed Drying. 1. Surface moisture of the seed that initially removed by the drying air.

The authors, William F. Wilcke and R. Vance Morey, are associate professor and extension engineer, and professor and head of the University of

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources

Grain Drying and Storage on Florida Farms 1

OPI-integris Advantages

Enclosure Temperature Control

GRAIN GUARD NEXT GENERATION ROCKET AERATION SPECIFICATIONS TOTAL LOUVERED AREA (SQ. FT) TOTAL SQ. FT

Understanding Water Use by Plants in a Cloche System - Gardening

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

ASHRAE JOURNAL ON REHEAT

Drying principles and general considerations

New Insights into Natural Aeration Grain Drying Systems

Solar Still - Improved Distillation

Desiccant Dehumidification - Effective Strategy for Drying Concrete Slabs

Natural Ventilation for Poultry

A D VA N C E D E L E C T R O N I C G R A I N D RY I N G C O N T R O L S S Q S E R I E S D R Y E R S

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

Natural-Air Corn Drying with Stirring: II. Dryer Performance

SQ SERIES DRYERS GRAIN MANAGEMENT SYSTEMS

STORED GRAIN MANAGEMENT Roger C. Brook and Dennis G. Watson Department of Agricultural Engineering Michigan State University

Design and Optimization of Domestic Solar Dryer

Enclosure Temperature Control

Grain Dryer Exhaust Air Recycling System

Introduction. On farm dryer. Research Gap. Overall goal - Generating data for a simulation model. Objective 5/18/2015

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

Climate effect on strategy sellection and energy consumption for in-bin drying of corn with natural air/low temperature

How about Savings in Time, Money, Energy and Longer Life?

Grain Dryers. Single Fan & Heater Dual Fan Heater Stacked Module. Easy Operation Higher Quality Grain Heavier Test Weights

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

The Basics of Package/Device Cooling

Master Gardener Vegetable Specialist Training. Prepared by: Thomas LeRoy

Calculating crop evapotranspiration using a dual crop coefficient Part 3

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Figure 1: Rice solar drier

Asparagus Response to Water and Nitrogen

Corn Irrigation and Water Use

SYSTEM OF RICE INTENSIFICATION (SRI) - PRINCIPLES AND METHODS

Guidelines for Optimizing Drying and Blow-Off Operations

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

SEED DRYING. Definitions 8/31/2017. Potential mechanisms involved in desiccation tolerance. Phases of Seed Development and Maturation

F-Series Tower Drying

mixed flow dryer one of the most efficient dryers on the market. Now CSA approved for Canada in 16, and 24' models.

Mixed Flow Dryer. One of the most efficient dryers on the market.

Sugarbeets Enjoy Warm Winter

A Practical Guide for Natural Aeration Grain Drying

2016 Iowa FFA Soils Evaluation CDE Exam

Southwest MN IPM STUFF All the pestilence that s fit to print

MODULAR & T-SERIES DRYERS

AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE

Dehumidification: Energy Efficiency Comparisons

Modern Green Roof Technology presented by Jörg Breuning, Green Roof Service LLC. Syracuse, New York November 17, 2011

Irrigating Lawns When Water Supply is Reduced Howard Neibling, Extension Water Management Engineer, University of Idaho

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Rough rice should be dried to a certain moisture

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

When Precision is not good enough

Managing sprinkler irrigation systems

Ventilation. The idea behind our climate systems is efficiency and advanced simplicity.

Understanding how Sclerotinia sclerotiorum initiates stem rot: factors affecting the germination of sclerotia

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

INTERNATIONAL PORTABLE GRAIN DRYINGPAGE

Water is a resource shared by all, and as Florida s population increases, so does the need for all of Florida s residents to conserve.

Solid biofuel solutions

Transcription:

Minimize Shrink from Grain Drying and Aeration Dry grain stored at cooler temperature has the minimal risk of spoilage from mold contamination and can be safely stored for longer periods (6-12 months). Freshly harvest grain is dried to safe storage moisture levels and then aerated (cooled) to nearly 35 F temperature for long term holding. For in bin-drying, warm and dry air with high water holding capacity is preferred since cool air has lower drying potential due to its reduced water holding capacity. At the completion of in-bin grain drying (also throughout the drying) grain is usually warmer than recommended temperature for long term safe storage. Aeration is the process of cooling the warm grain which has already been dried to safe storage/straight grade moisture levels. In aeration grain is assumed to have reached the target moisture levels and the objective is to cool it to nearly 35 F without further reducing its moisture content causing shrink. Shrink Shrink is the grain weight loss that occurs during handling, drying, aeration, and storage (quality loss as dry matter loss). The weight loss during handling, over-drying in mechanical (high temperature) and in-bin drying, and storage are considered significant. However, shrink due to grain moisture loss in aeration process is often neglected by farmers which could result in significant losses. Moisture Shrink Shrink in this article is exclusively referred to as weight loss in the grain due water removal as result of over-drying in high temperature drying, in-bin natural air drying, and aeration. In simple terms, shrink is estimated based on the assumption that all the weight loss during these conditioning processes is the moisture loss only. The shrink loss is calculated by dividing the weight of moisture lost during conditioning divided by the total initial grain weight. The calculated shrink is often represented in percentage by multiplying this ratio by 100. The following examples shows the shrink loss for 10,000 lb corn at 15.5% wet basis (wb) which is over-dried to 14.5% (wb) and 13.5% (wb) in aeration and drying process, respectively. The maximum permitted moisture for the U.S. No. 2 grade corn is 15.5% (wb) (corn is typically priced for U.S. No. 2 grade) so it was assumed target moisture. In 10,000 lb corn at 15.5% moisture, the amount of total water present is: Weight of water (lb) = 10,000 lb 15.5/100 = 1550 lb The weight of dry matter (lb) = 10,000 lb 1550 lb = 8450 lb When the corn is over-dried to 14.5%, the weight of dry matter will remain same but the weight of water will reduce as the grain weight loss is due to moisture removal.

So, the total weight of corn when over-dried to 14.5% is: Total grain weight = Weight of water + Weight of dry matter Total grain weight = w lb + 8450 lb (assuming weight of water is reduced to w lb after drying to 14.5%) Therefore, Final moisture content (%) = (Weight of water/total grain weight) 100 14.5 = (w lb/(w lb +8450 lb)) 100 14.5/100 = w/(w+8450) 0.145 (w+8450) = w 0.145 w + 1225.25 = w w - 0.145w = 1225.25 0.855w = 1225.25 w = 1225.25/0.855 = 1433 lb Hence, the total water loss due to over-drying of corn to 14.5% from 15.5%: = 1550 lb -1433 lb = 117 lb Shrink loss = (Water loss/initial weight) 100 = 117 lb/10,000 lb 100 = 1.17 % Similarly, we can calculate shrink loss for over-drying corn to 13.5% from 15.5% which will be about 2.31%. Though these losses seem to be a small percentage but they would result in significant savings as shown in Table 1 and in example below for corn (Grain with higher $ value such as soybean the savings would be twice). Example, 1,000,000 bu of corn over-dried to 14.5% from 15.5% (1.17% shrink loss) would result in total water loss of: = 1,000,000 X 1.17/100 = 11,700 bu With corn priced at $6/bu, this could result in potential savings of: = 11,700 X 6 = $70,200

Table 1: Shrink loss calculation and potential saving estimates for corn 1.17% Shrink (Corn over-dried to 14.5% from 15.5%) 2.31% Shrink (Corn over-dried to 13.5% from 15.5%) Grain in bu Water loss, bu Potential savings ($)* Grain in Bu Water loss, bu Potential savings ($)* 10,000 117 702 10,000 231 1,386 25,000 292.5 1,755 25,000 577.5 3,465 50,000 585 3,510 50,000 1,155 6,930 100,000 1,170 7,020 100,000 2,310 13,860 250,000 2,925 17,550 250,000 5,775 34,650 500,000 5,850 35,100 500,000 11,550 69,300 1,000,0000 11,700 70,200 1,000,000 23,100 138,600 *Corn priced at $6/bu (Based on Manhattan Coop September 1st, 2013 price) Manage Shrink The calculation in previous example and Table 1 show that there is huge potential for significant savings by minimizing the shrink loss in drying and aeration. In-bin Drying In natural air in-bin drying, several factors could lead to shrink loss. Traditional way of running the fan continuously often results in major shrink loss as bottom layer highly over-dries by the time top grain reaches the target moisture. Fan control strategies that only allow the fan to run when good quality air with drying potential is available can significantly reduce the shrink by uniformly drying the grain with minimum moisture spread. Fan controls in IntegrisPro allow the fan to run when plenum air equilibrium moisture content (EMC) is in the desired range. The fan does not operate below lower EMC band which minimizes over-drying and shrink loss. Sometimes in hot and dry ambient conditions, EMC may not be in the target range for significant portion of the day reducing fan run time per day leading to the extended drying time (calendar-wise). Self-adapting variable heat (SAVH) control strategy in IntegrisPro uses a lower EMC band initially to increase the daily fan hours and then rehydrates the bottom layers by moving up the lower EMC band. Insufficient and non-uniform airflow rate is another significant factor that may cause the shrink. If airflow rate is insufficient (< 0.5 cfm/bu), the drying time (total number of fan hours) may increase 2-3 times compared to drying time with recommended 1 cfm/bu airflow rate. The increased fan run time will over-dry the bottom layers causing the shrink loss while top grain moisture may remain unchanged/under-dried. Non-uniform airflow distribution may also cause significant shrink loss. Bins are sometimes peaked

with higher concentration of broken, fines, and foreign materials accumulated around the core causing increased resistance to airflow. Since, air flow takes the path of least resistance; airflow rate may be 2-3 times higher near the bin side walls (with shallower grain depth and less fines, broken and foreign material) compared to the central core. Therefore, drying of grain in around core will take 2-3 times longer to reach the target moisture compared to the grain near bin walls. Due to this increased fan run time, grain close the bin walls will be highly over-dried by the time grain around central column reaches the target moisture causing major shrink loss and excessive energy consumption. To minimize the shrink loss, grain bins should be cored and if possible the grain should be leveled. Heaters installed in the grain bins are often operated with misunderstanding that additional heat will accelerate the drying in cold weather. However, the objective to add small amount of supplemental heat is to reduce the humidity of highly humid air so that plenum EMC is in the desired range. Running the heater when the ambient relative humidity is below 70% will significantly reduce the plenum EMC resulting in over-drying and high shrink loss. Increasing the amount of heat (>12-15 F temperature rise) also does not accelerate drying process and only results in increased shrink. Aeration The objective of aeration is to cool the grain which has been dried to a safe storage target moisture level. Traditional way of aerating the grain by running the fan continuously or in multiple cooling cycles (2-3) could result in excessive fan run time and large shrink. A fan control based on running the fan below a set temperature (e.g., below 60 F in early autumn and below 45 F in late autumn) or when ambient air daily average temperature is 10-15 F below the grain temperature is not an efficient way of aerating the grain. It ignores the effect of fan warming, particularly, in tall bins, where fan warming could be 5-8 F resulting in increased plenum air temperature. Also, this strategy does not consider ambient RH (thus EMC) so the cooling may be achieved but there could be significant shrink loss (Table 1 shows the $ value of 1% of over-drying). Aeration fan control strategy in IntegrisPro considers both air temperature and EMC so that fan only operates when EMC is close to the grain moisture and grain can be cooled to the target temperature (35 F) without over-drying and shrink loss. The IntegrisPro aeration fan control strategy consumes less fan hours compared to aeration in multiple cycles. OPI is proud of the contribution we've made to the agricultural industry in the US and around the world in our 30 year history. Our on-going commitment to advancing grain storage management has yielded numerous innovations to help farmers and agribusiness protect and optimize the value of their stored

grain assets. We are the recognized world leading supplier of grain storage management solutions. In 2014 OPI launched OPI Blue - putting 30 years of grain monitoring expertise in the palm of your hand.