New Insights into Natural Aeration Grain Drying Systems

Similar documents
A Practical Guide for Natural Aeration Grain Drying

Aeration vs NAD vs NAD+heating vs Heated Air Drying

Grain and Soybean Drying on Georgia Farms

Applying Technology for Agriculture

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

Drying and Cooling Stored Grain and Preserving its Quality

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Minimize Shrink from Grain Drying and Aeration

CC196 Guide for Batch-Drying in a Bin

Psychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

Grain Handling, Drying and Storage Management

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

Why is it essential to measure moisture in stored crops, such. Why is it important to measure multi point and in-sitú in the storage silo?

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

Aerating Grain in Storage

CC196 Revised with no date Guide for Batch- Drying in a bin

9 - On Farm Storage and Drying

Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, Bob Marlow, The Andersons, Inc

Postharvest Storage. New Farmer Webinar. October 17, 2013

Grain Dryer Efficiency. Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc th Street Rockford, IL 61104

A/C Cooling Load calculation and measurement

The following table summarizes information from various sources on corn development.

announcements 4/10/08

Cooling Load Analysis and Computation Worksheet Answers Part 1 Psychrometrics

Dehumidification: Energy Efficiency Comparisons

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

Task Force. Rewarming Supercold Grain. Dirk E. Maier, Agricultural Engineering

EVALUATION OF SWINE FACILITIES VENTILATION

Reducing Energy Use in Grain Dryers

Cooling Load Analysis and Computation Worksheet

Grain Dryer Exhaust Air Recycling System

Estimated Corn Field Drying

Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex.

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

AHRI 920 & ASHRAE 90.1

State-Of-The-Art Developments to Save Energy in Coating Drying. Bob Bates, P.Eng Metso Paper

Last exam / sista tent

Pallet Hop Dryer. Introduction

EasyDry. Grain Drying Systems

Condensing Humidified Air Recuperator

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Flexible cropping systems allow for an opportunistic

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

OF BUILDING MATERIALS FACULTY OF ENGINEERING (LTH), LUND UNIVERSITY, SWEDEN

AIR & SCREEN CLEANER MODEL: AS4 PRODUCT MANUAL

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Pressure Enthalpy Charts

*RENTAL* Explosion Proof Portacool Portable Evaporative Cooler - C1D1 - Water Mist Cooler - 30" OD

5. ASSESSMENT RECOMMENDATIONS

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

These are non-living factors that influence the performance of a crop. Ex. Climate, weather, soil type, soil fertility, etc.

Humidity Control & Psychrometrics

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

, A Product Catalog

HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

100% Outdoor Air Dehumidification Methods

Optimize Evaporative Cooler

Aerating Farm -Stored Grain

EC Series Wall Unit Humidifier

2. In areas of the world where outdoor temperatures are low enough to drop the interior building temperature below setpoint.

MIXING RATIO AND ABSOLUTE HUMIDITY

Integrating Emerging Technologies and Codes & Standards

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

YUJING LI, Ph.D. DIV. OF BUILDING MATERIALS FACULTY OF ENGINEERING (LTH), LUND UNIVERSITY, SWEDEN MARCH 25 TH 2014, GÖTEBORG

PLANTING GUIDE TO GRASSES AND LEGUMES

Environmental Chambers

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Evaluation Report 578

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Grain Flow. Grain Flow. Efficient Reliable Accurate. Automatic In-Bin Continuous Flow Grain Drying. David Manufacturing Co.

NON-CYCLING REFRIGERATED AIR DRYERS. GSRN Series

27/11/2015. How does a greenhouse work: humidity. Energiezuinig ontvochtigen. Climate control, humidity

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

THERMAL MASS CYCLING REFRIGERATED AIR DRYERS. GTRC Series

Partial Load Performance Of Refrigeration System

2014 O.G.S. Harvest Conference Back Yard Composting Made Easy. Mark Langner MAYTime Composting Burnsville, NC

Week 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

July News. NORTH FLORIDA BONSAI CLUB July Please note there will be NO MEETING in July. Work is being done to the Mandarin Garden Club

Humidity An excuse for the 80s

Microelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number

May 14, Write Your Own (WYO) Principal Coordinators and the National Flood Insurance Program (NFIP) Direct Servicing Agent

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

LAZY A/C with KEN GEHRING President Emeritus at Therma-Stor LAZY AC

Copy Right By: Thomas T.S. Wan

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

TWO- AND THREE-STAGE CASCADE REFRIGERATION SYSTEM By: Paul B. Reed

Transcription:

New Insights into Natural Aeration Grain Drying Systems IHARF Winter Seminar Melville Communiplex February 1, 2012 11:00 AM Ron Palmer P.Eng P.Eng.. Ph.D. Bin #9 Bin #10

Objective To build a fan controller that: is Efficient saves power, fan on only when necessary (if drying fan on, if not drying fan off) Provides Safe Grain Storage i.e.. No spoilage Cool grain Dry grain Strategy Only run the fan when ambient air conditions will result in drying of the grain; but, that s the question: how do we know what conditions will produce drying and what conditions will produce no drying or even wetting?

Vapour Pressure Air surrounding kernel Grain kernel Water trying to get in = Vapour Pressure Air temperature relative humidity When air vapour pressure is greater than grain vapour pressure, water enters the grain and WETTING occurs. When Vps are equal, EMC Water trying to get out = Vapour Pressure Grain % moisture content temperature type & condition of grain When grain vapour pressure is greater than the air vapour pressure, water evaporates from the grain into the air and we have DRYING

Controller Vapour Pressure? Fan ON only if VP grain > VP air This is not practical because: Although VP air is easy to determine from temperature and relative humidity; it varies across the bin VP grain can not be measured directly, and it too varies across the bin. We need another approach

The Black Box Approach H 2 O IN Black Box = Grain Bin H 2 O OUT If H 2 O OUT > H 2 O IN then FAN ON (drying) If H 2 O IN > H 2 O OUT then FAN OFF (wetting)

lbs Water OUT lbs Water IN = Water Removed Water OUT If the Water Removed is positive, then this is the amount of water that must have come from the grain and therefore we are DRYING If the Water Removed is negative, ie there is more water that went in than came out; then the water must have gone into the grain :: WETTING For example: let s say that in one hour we measured 80 lbs of water going into the bin and 90 lbs of water coming out. The net result is 10 lbs of water being removed from the bin. And it must have come from the grain, so we are drying. But how do we measure the amount of water going in and out? How much water is the air carrying? Water IN (carried in by the air)

14 Maximum Amount of Water that 6000 cu ft of Air Can Hold Psychrometric Chart lbs water in 6000 cf 12 10 8 6 4 2 0 lbs water @100%RH Table Formula 12.84 lbs at 90 F Saturation 9.5 lbs at 80 F 5 lbs at 60 F 2.5 lbs at 40 1 at 20 Temperature Deg F -40-20 0 20 40 60 80 100

Water Holding Capacity 14 12 lbs water/6000 cf 10 8 6 4 100% 75% 50% 25% 2 0-10 -5 0 5 10 15 20 25 30 Temperature Deg C

H 2 O IN/OUT Example We have a 2000 bu bin with an aeration fan with a flow of 3000 cfm.. The air going into the fan and into the bin is 60 F @ 55% RH. The air leaving the bin is 80 F @ 45% RH. Are we drying? How much? From the previous psychrometric chart for 6000 cu ft, 80 @ 45% = 4.27 lbs H 2 0 ->air 6000 cu ft, 60 @ 55% = 2.74 lbs Every 2 min remove 1.53 lbs ::(drying)

14 Amount of Water that 6000 cu ft of Air Can Hold Psychrometric Chart lbs water in 6000 cf 12 10 8 6 4 2 0 lbs water @100%RH 9.5 lbs at 80 F 100% 4.97 at 60 100% 4.27 lbs at 80 F 45% 2.74 lbs at 60 Saturation 4.97 x.55 = 2.74 Temperature Deg F -40-20 0 20 40 60 80 100 Table Formula 9.5 x.45 = 4.27

The Black Box Approach H 2 O IN 2.74 lbs at 60 F 55% Per 6000 cu ft. Black Box = Grain Bin H 2 O OUT 4.27 lbs at 80 F 45% Per 6000 cu ft. If H 2 O OUT > H 2 O IN then FAN ON (drying) 4.27 lbs > 2.74 lbs FAN On (1.53lbs/6000) Fan 3000 cfm or 6000 cu ft/2 min 46 lbs/hr drying

What we did Instrumented Two Bins and measured on an hourly basis: Temp and Humidity air in and out Air Flow Temp of Grain at three levels On a daily basis measured grain moisture at 4 levels Have done this for 4 years with 3 different grains peas, barley, and wheat

Sampling ports for Grain Moisture Temperature Probes

Panel with Instruments

Air Tubes for Recording CFM

RH and Temperature Probe On Inside Top of Bin Recording RH and T o.

Inside the Panel

Sensor measuring T and RH of the air leaving the bin Amount of Air Out = Amount of Air In Therefore we know the temp & RH of the air leaving the bin, and we can calculate the number of lbs of water leaving the bin per hour Sensor measuring T and RH of the air entering the bin can calculate the number of lbs of water entering the bin per hour

Data stored hourly in Excel Date/Time Low Mid High Air Leaving CFM Air Entering Temp Temp Temp Temp RH Temp RH

Pea Bin 10 2009 200.0 150.0 lbs water removed/hr 100.0 50.0 0.0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113-50.0-100.0 hours

Bin 10 2011 200 150 100 lbs water 50 0 1 16 31 46 61 76 91 106 121 136 151 166 181 196 211 226 241 256 271 286 301 316 331 346 361 376-50 hours

Sept 23 shrt2010 Bin 10 70.0 60.0 Start 2:30 11 to 9:30 AM remove 532 lbs 50.0 lbs water removed/hr 40.0 30.0 20.0 10.0 0.0-10.0 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 101 106 111 116 121 126 131 136 141 146 151 156-20.0-30.0-40.0 Add 152 lbs During next day 19 Hours

#1 3453 lbs 2.86% 2007 wheat 80.0 Start 5PM 25 C Wheat 15.6% First Night 500 lbs removed grain cooled 23 to 16 60.0 40.0 lb s w a te r/h r 20.0 0.0 1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103 109 115 121 127 133 139 145 151 157 163 169 175 181 187 193 199 205-20.0-40.0 9AM 6PM 27 76 lbs Hours 10 lb/hr would remove 4332 lb In 134 hours about 60% time -60.0

#2 2007 Spr Wheat 4076 lb = 3.4% 200.0 150.0 Start 1:30PM to 9AM removed 1370 lbs Wheat chilled from 20 to 4 Outside temp goes to -3 lbs w ater/hr 100.0 50.0 0.0 1 9 17 25 33 41 49 57 65 73 81 89 97 105 113 121 129 137 145 153 161 169 177 185 193 201 209 217 225 233 241 249 257-50.0 Hours

80.0 60.0 40.0 S23 2010 Wheat #10 Run for 736 hours or 31 days Remove 7812 lbs water 6.5% = 14.2 Measured moisture = 13.7% 485 lbs removed 5 C midnight RH 60% lb s w ater rem o ved /h r 20.0 0.0 1 20 39 58 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419 438 457 476 495 514 533 552 571 590 609 628 647-20.0-40.0 Started 2:23 PM 20.7% 532 lbs removed til 9:23 AM, then put 152 lbs -60.0 in the next day If we run fan only > 10 lbs/hr -286 lbs Would remove 9977 in 369 hrs 2:30 PM 26 C 50%RH Hours

#3 2207 Spr Wheat 3293 lbs = 2.7% 80.0 Start 12:30 PM to 10:30AM remove 713 lbs water Wheat goes from 17 to 9 C as outside goes to 7 60.0 40.0 lbs w ater/hr 20.0 0.0 1 11 21 31 41 51 61 71 81 91 101 111 121 131 141 151 161 171 181 191 201 211 221 231 241 251 261 271 281 291 301 311 321 331 341 351 361-20.0-40.0 Hours

Wheat Bin 9 2009 120.0 100.0 80.0 Wheat is almost 20% and hot,( almost 30 C), the first night it only goes to 17 C, the grain cools to 20 so the next day we slip by without wetting the grain. Still remove 900 lbs of water. 60.0 40.0 20.0 0.0 1 9 17 25 33 41 49 57 65 73 81 89 97 105 113 121 129 137 145 153 161 169 177 185 193 201 209 217 225 233 241 249 257 265-20.0-40.0-60.0-80.0

Start 1:30 PM 8:00 AM = 984 lbs removed 9:00 AM 9:00 PM = -247 lbs (added) 9 9 night = 298 removed 9 9 day = -340 (added) 200.0 Start 1:30 PM Pea Bin 10 2009 lbs water removed/hr 150.0 100.0 50.0 0.0-50.0-100.0 Grain temp 27 to 13 C 984 234 298 441 301 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113-247 -340-416 -404 hours Net 851 lbs 15.6 14.8 14.9 14.6 14.2 14.2

Ambient Temp Pea#10 2009 35.0 30.0 The days had highs from 25 to 30 C 25.0 20.0 deg C 15.0 10.0 5.0 First couple of nights had lows of 10 C 0.0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113 hours starting 1:36 PM Aug 29

What s going on here?? First day, warm air hits the warm grain and plenty of drying takes place. First night, cool dry air hits the warm grain. The air is warmed by the grain, lowering its RH so it can hold more water, and so it does by drying the grain. The next day, the warm moist air hits the cool grain, cooling the air. Moisture is released into the grain.

Pea#10 2009 Outside Tx2 200 150 By observation it was noted that the temp difference of the discharge air minus the ambient air temp is a close match to the drying. 100 If the discharge temp (temp of grain) > ambient then FAN ON lbs H20 out F x2 50 0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113 117 lbs water o Dish T - Air -50-100 -150 If the temperature of the grain is hours greater start 1:36 than PM the outside air temp, then we are in a drying condition and the fan should be turned on. If the grain temp is < outside air temp, then turn the fan off. The controller only needs to monitor these temps.

Grain Temp Pea#10 2009 30.0 25.0 The peas were near 30 C when we started, and were cooled the first night to 13 C, but then later heated the peas to > 25 C 20.0 deg C 15.0 10.0 5.0 If the fan was turned off here, the peas would have remained at a safe 13 C, the fan would be on for 20 hr = (.35 x 20hr ~ $7) as compared to (.35 x 120 hr. ~ $42) 0.0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113 hours starting 1:36 PM Aug 29

Recommendations GOOD if you insist on running the fan continuously, when you do turn it off, do so in the early morning (when it is cold). BETTER turn the fan off during the day and on at night. (Yard light rule) BEST a controller: If ambient air temp < grain temp FAN ON If ambient air temp > grain temp FAN OFF

It Works! Chad Skinner has tried this with side by side trials and found the on-night/off night/off-day was as effective as the continuous-fan fan-on. Lentils 18% to 14% in 5 days (3hp 2000 & 3300) Wheat 17% to 13% in 7 days (7.5hp 5000bu) Canola Conclusion: Only need to run the fan half the time and your grain will be cooler and safer

Bin 10 2011 200 Let s try this temperature difference scheme on last year s run 150 100 50 0 1 16 31 46 61 76 91 106 121 136 151 166 181 196 211 226 241 256 271 286 301 316 331 346 361 376-50 hours

Bin 10 2011 200 150 100 50 lbs water 0-50 1 16 31 46 61 76 91 106 121 136 151 166 181 196 211 226 241 256 271 286 301 316 331 346 361 376-100 -150-200 Hour Grain Temp Air Temp 0 27 31-14 14 25-13 36-48 14-9 9 13-8 hours 259-289 289 12-55 12-5 302-312 312 5.6-6 6 5-5 5.49 Fan on for 81 hrs ($28) instead of 383 hrs ($134) and grain at 6 6 C

Observations Cooling the grain also dries it. An enormous amount of water is removed the first day as the grain is cooled. The top remained at the same moisture content, until the dry-front came up. Best drying takes place at night, while significant wetting occurs during hot days. Temp difference Grain Air Drying

Conclusions Best drying conditions are when the air is cold and the grain is hot. Its not a race to dry the grain before it spoils,, it is a race to cool the grain before it spoils. For the best grain storage, keep the grain as cold as possible. < spoilage, < OTA, < mold Only need to run the fan half the time (night), 50% saving in electricity. Best strategy is to run the fan only if we are drying the grain.

Yard Light Rule On at night You are bright On upon day You will pay And that s the lesson of the day! Questions? Comments?