Dublin airport - Dublin, Ireland

Similar documents
LED EMERGENCY LIGHTING

Emergency light. Safe solutions

D O M E S T I C LED. Lighting C O M M E R C I A L

Making Perfect Sense Of Safety

Requirements of EN 1838: illuminance of 5 lx for safety equipment

ENERGY EFFICIENT LED SOLUTIONS

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

EMERGENCY LIGHT SERIES

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY

THE POWER BEHIND LIGHTING

FDV BA- Lighting AS BA24-CL76-8WD

Avenue Metro. The evolution of an icon. UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX

Emergency Lighting Design

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Technical Application Guide for UP-SHINE LED Downlight

FR-A180 FR-A360. Occupancy detector. Use

Linergy II. England and Wales Cricket Board, Truro Linergy

StoreFlux powerful LED accent lighting that blends perfectly in the store architecture

Fire-rated downlights

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

LED ROUND MINI PANELS

Micropoint 2 Surface. Emergency

Acacia Batten. Contents. Willow Range 3 YE AR. Single. Twin. Single

New 10YR. The market leading range of fire-rated LED downlights. Introducing FGLED10 WARRANTY

Saving on maintenance and energy

Technical reference Reference & design

Vaya Linear LP, White & Mono

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Emergency Lighting User's Guide

lumenalpha downlight Specification Sheet

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

High-performance LED Elbow spot

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

MANUFACTURED IN THE UK

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

CoreLine Waterproof the clear choice for LED

Emergency Lighting Guide. An authoritative guide to emergency lighting systems and design techniques

ClearAccent - Affordable recessed LED spot

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

i-p65 is a high specification competitively priced emergency LED bulkhead utilising the latest LED and optic

New GuideLed safety luminaires

110 lm w STANDARD SERIES

CHALLENGER 66 INDUSTRIAL

GOODLIGHT LED. Dynamic Lighting. Normal care / Wall lighting unit

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

performance PowerBalance, surface mounted Benefits Features Application Specifications

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Serenga LED Emergency Lighting

PSFL , PSFL , PSFL , PSFL , PSFL

ArtLED Gallery and Museum Spotlights

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

CoreLine Wall-mounted the clear choice for LED

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

Installation Guide. Ceiling PIR Detector (311) Features and Connections

BSSLED INTRODUCTION.

Dimmable LED Retrofit Kit

SmartBalance recessed combining performance with smart design

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

EMERGI-LITE An authoritative guide to emergency lighting & central power systems

Inferno LED - MR16 - GU10 DESIGNER FIXED AND ADJUSTABLE 90 MINUTE FIRE RATED DOWNLIGHTS COMPLIANT WITH BUILDING REGULATIONS:

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

DOWNLIGHTS SPOTLIGHTS DALI TRACK ACCENT & GENERAL LED LIGHTING SOLUTIONS

Technical Application Guide for UP-SHINE LED Ceiling light

Product Specifications MaxLumen MRI LED Diffused Lighting

ONE LED Installed. ONE LED Petrol Station Retro Fit 80W LED E40 Lamps in Canopies. LED Panel llights & PL LED Retro Fit Lamps in shop.

Wallpackette III. Wallpackette III

Technical Application Guide for UP-SHINE LED Frameless Panel Light

EMERGENCY LIGHTING SYSTEM

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

CoreLine Recessed Spot the clear choice for LED

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

CoreLine Recessed Spot the clear choice for LED

Nightfall. led emergency egress lighting

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

Product Catalogue. Specialist in Emergency Lighting and Exit Sign

Product Specifications

TROFFER RETROFIT KIT (TRK)

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SmartBalance Free Floor Standing combining performance with smart design

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

The New Lux-Ray LED Emergency Lighting

SmartForm top-class lighting in a fresh, appealing design

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Catalog # Project. Comments. Prepared by

LED Outdoor Wall Light Series

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

LED Seamless VaporProof Fixture Installation Instruction

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

SOUTH AFRICAN NATIONAL STANDARD

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

Transcription:

Dublin airport - Dublin, Ireland

604 Route LED 607 Route LED II 608 SYL Safe EMERGENCY 601 Emergency

80 Hammersmith Road - London, England

Control Gear: Electronic Integral Sensor: Not applicable Emergency: 3 hours Reflector: None Housing: Acrylic Route LED Downlights 603 EMERGENCY

RouteLED - Standard Miniature ceiling recessed non maintained 3hr emergency 3W Accent LED downlight with green charge indicator Stand alone unit complete with inverter module and Nickel-Cadmium battery pack Inverter and battery pack pass through the luminaire cut out Quick and easy installation with simple plug and socket connections Custom RAL colours available on request LIGHT SOURCE INCLUDED RouteLED - Standard Code Description Colour 9192132 RouteLED 3W Emg White 9154072 DALI RouteLED White 9150539 Selftest RouteLED White 9150374 Surface RouteLED 3W Emg White 9154085 Surface DALI RouteLED 3W Emg White 9150511 Surface Selftest RouteLED White Input Voltage 4V DC Max Power Rating 700mA Light Source Edison EDEW Series Beam Angle 110º Cut Out Ø 43mm Light Source Colour Cool White Colour Temperature 6000K Luminaire Output 194 Lumens General CRI 70 Tc Max 80ºC LED Backplate Wiring Method Series connection via C201 Series Plug Dimensions Ø 50mm x 50mm Spacing Table Mounting To Wall Between Fittings Height 0.5 1.0 0.5 1.0 2.5 4.1 3.3 9.5 8.1 3.0 4.5 3.5 10.6 8.8 4.0 4.9 3.5 12.1 9.6 5.0 5.0 3.1 13.1 9.8 6.0 4.9 2.3 13.8 9.6 8.0 3.7-13.8 6.3 5mm 27.7mm Ø50mm Bi-Colour LED 300mm Connection Details 1. White - ve Charge LED 2. Black - ve Emitter 3. Green + ve Charge LED 4. Red + ve Emitter 3 4 1 2 Surface Mounted Versions Diameter 185mm x 40mm deep 604 Emergency

RouteLED - Open Area Miniature ceiling recessed non maintained 3hr emergency 3W Accent LED downlight with green charge indicator Stand alone unit complete with inverter module and Nickel-Cadmium battery pack Inverter and battery pack pass through the luminaire cut out Quick and easy installation with simple plug and socket connections Custom RAL colours available on request LIGHT SOURCE INCLUDED RouteLED - Open Area Code Description Colour 9192134 RouteLED 3W Emg Open Area White 9154043 RouteLED 3W Emg DALI Addressable White 9154068 Selftest RouteLED Open Area White 9154080 Surface RouteLED 3W Emg Open Area White 9154181 Surface DALI RouteLED 3W Emg Open Area White 9154070 Surface Selftest RouteLED Open Area White Input Voltage 4V DC Max Power Rating 700mA Light Source Edison EDEW Series Beam Angle 110º Cut Out Ø 43mm Light Source Colour Cool White Colour Temperature 6000K Luminaire Output 207 lumens General CRI 70 Tc Max 80ºC LED Backplate Wiring Method Series connection via C201 Series Plug Dimensions Ø 50mm x 50mm Spacing Table Mounting To Wall Between Fittings Height 0.5 1.0 0.5 1.0 2.5 3.8 3.5 8.1 7.5 3.0 4.4 3.9 9.3 8.6 4.0 5.3 4.5 11.6 10.5 5.0 6.1 3.6 13.7 11.8 6.0 6.2-15.5 8.3 9mm 27.7mm Ø50mm 300mm Connection Details 1. White - ve Charge LED 2. Black - ve Emitter 3. Green + ve Charge LED 4. Red + ve Emitter 3 1 4 2 Surface Mounted Versions Diameter 185mm x 40mm deep Emergency 605

RouteLED - Corridor Miniature ceiling recessed non maintained 3hr emergency 3W Accent LED downlight with green charge indicator Stand alone unit complete with inverter module and Nickel-Cadmium battery pack Inverter and battery pack pass through the luminaire cut out Quick and easy installation with simple plug and socket connections Custom RAL colours available on request RouteLED - Corridor LIGHT SOURCE INCLUDED Code Description Colour 9192136 RouteLED 3W Emg Corridor White 9154044 RouteLED 3W Emg Corridor Lens DALI Addressable White 9154069 Selftest RouteLED Corridor White 9153981 Surface RouteLED 3W Emg Corridor White 9154182 Surface DALI RouteLED 3W Emg Corridor White 9153982 Surface Selftest RouteLED Corridor White Input Voltage 4V DC Max Power Rating 700mA Light Source Edison EDEW Series Beam Angle 125 deg x 50 deg Cut Out Ø 43mm Light Source Colour Cool White Colour Temperature 6,000K Luminaire Output 197 lumens General CRI 71 Tc Max 80ºC LED Backplate Wiring Method Series connection via C201 Series Plug Dimensions Ø 50mm x 50mm Spacing Table Along Corridor (Length) Mounting To Wall Between Fittings Height 0.5 1.0 0.5 1.0 2.5 5.0 4.4 11.5 9.9 3.0 5.6 4.9 12.7 11.1 4.0 6.7 5.4 15.2 13.3 5.0 7.5 4.1 17.5 14.1 6.0 7.1 2.9 19.4 14.0 8.0 4.7-20.0 9.2 Spacing Table Along Corridor (Width) Mounting To Wall Between Fittings Height 0.5 1.0 0.5 1.0 2.5 2.2 1.8 6.5 4.3 3.0 2.3 1.9 6.6 4.5 4.0 2.7 1.9 6.2 5.2 5.0 2.8 1.9 6.9 5.4 6.0 2.7 1.4 7.5 5.2 8.0 2.3-7.5 3.6 11mm 27.7mm Ø50mm 300mm Connection Details 1. White - ve Charge LED 2. Black - ve Emitter 3. Green + ve Charge LED 4. Red + ve Emitter 3 4 1 2 Surface Mounted Versions Diameter 185mm x 40mm deep 606 Emergency

RouteLED II Miniature ceiling recessed non maintained 3hr emergency 2W LIGHT SOURCE INCLUDED Accent LED downlight with green charge indicator Stand alone unit complete with inverter module and Nickel-Metal Hydride battery pack Inverter and battery pack pass through a 40mm cutout Quick and easy installation with simple plug and socket connections Outstanding performance - 9m open area and 19m corridor spacing (see table below) RouteLed with corridor lens RouteLED II Code Description Type Lense Colour 2059459 RouteLED II Open Area Standard Open area White 2059460 RouteLED II Corridor Standard Corridor White 2059461 RouteLED II Open Area DALI DALI Open area White 2059463 Route LED Corridor DALI DALI Corridor White 2059462 RouteLED II SM Accessory Surface mount accessory - White Open area - 200lm Corridor lens - 200lm Spacing Table Room Size 15 x 15m Open Area Lens Mounting height Wall to fitting Fitting to fitting Total Lux 2.7m 3m 9m 1.2lx 3m 3m 9m 1.3lx 4m 3m 9m 1.3lx 5m 3m 9m 1.2lx 6m 3m 9m 1.1lx 5.5 8.4 Room Size 15 x 15m Corridor Lens Mounting height Wall to fitting Fitting to fitting Total Lux 2.7m 7.5m 19.9m 1lx 3m 7.5m 19.9m 1.1lx 4m 7.5m 19.9m 1lx 5m 7.5m 19.9m 1lx 6m 5.4m 12m 1.2lx 61.0 Ø45.5mm Dimensions (mm) Emergency 607

SYL Safe This guide should be read in conjunction with current standards. Legislation Changes & Requirements The British Standard BS5266 has been revised to conform with the European Standard EN1838 (issued in the UK under reference BS EN1838/BS5266 Part 7) which specifies luminous requirements for Emergency systems installed in premises. It also now calls up the luminaire product standard BS EN60598-2-22: 1999. Emergency lighting is provided for use when the supply to the normal lighting fails and is therefore powered from a source independent of that supplying the normal lighting. For the purposes of this standard Emergency lighting is regarded as a generic term of which there are a number of forms. Definitions Emergency EXIT A way out that is intended to be used in an Emergency. ESCAPE ROUTE A route designated for escape in the event of an Emergency. Emergency ESCAPE LIGHTING That part of Emergency lighting that provides illumination for the safety of people leaving a location or attempting to terminate a potentially dangerous process before doing so. ESCAPE ROUTE LIGHTING That part of Emergency escape lighting provided to ensure that the means of escape can be effectively identified and safely used when the location is occupied. Emergency OPEN AREA LIGHTING In some countries this is known as anti-panic lighting. This relates to that part of Emergency escape lighting provided to avoid panic and provide illumination, allowing people to reach a place where an escape route can be identified. HIGH RISK TASK AREA LIGHTING That part of Emergency escape lighting that provides illumination for the safety of people involved in a potentially dangerous process or situation and to enable proper shut down procedures for the safety of the operator and other occupants of the premises. Areas Covered/Levels of Illumination DEFINED ESCAPE ROUTE Based on 2m wide on the horizontal plane, preferably 1 lux but not less than 1 lux on the centre line. The lighting provided should operate within 5 seconds of the failure of the normal supply. OPEN AREA (Sometimes referred to as anti-panic lighting) Not less than 0.5 lux at floor level of the open space. The ratio of max to min illuminance should be no greater than 40:1. These extracts are provided for guidance purposes. In order to fully comply with the many elements of the various applicable standards, a full and thorough assessment must be made. 608 Emergency

SYL Safe Slimline white steel housing Wall or flush ceiling mounted White painted metal housings Silk screened legend panels Supplied arrow down as standard LIGHT SOURCE NOT INCLUDED (SELECTED MODELS) Syl-Safe LED Code Description Type 9154003 LED Exit Suspended Arrow Down / Left / Right 9153908 Recessed / Flush LED Exit Arrow Down 9150509 LED Exit Sign Arrow Down Syl-Safe Code Type Type Description Wall mounted 9136524 T5 8W Wall Mounted Exit Permanent 9137011 T5 8W Wall Mounted Exit Self Test Non-Maintained 9137012 T5 8W Wall Mounted Exit Self Test Permanent Standard exit sign Flush mounted 9137006 T5 8W Flush Mounted Exit Non-Maintained 9137007 T5 8W Flush Mounted Exit Permanent 9137008 T5 8W Flush Mounted Exit Self Test Non-Maintained 9137010 T5 8W Flush Mounted Exit Self Test Maintained Above luminaires are supplied with standard exit sign with arrow down legend. Left and right arrow versions available to order, see below. Left and right legends LED Exit Suspended Code Description Exit Type Wall mounted 9137834 Legend only arrow left Wall Mounted Exit Sign Legend 9137835 Legend only arrow right Wall Mounted Exit Sign Legend Flush mounted 9137832 Legend only arrow left Flush Mounted Exit Sign Legend 9137833 Legend only arrow right Flush Mounted Exit Sign Legend Recessed / Flush LED Exit Operation Non-Maintained Maintained Mains only Light source 1 x 8 Watt T5 Construction Steel enclosure and gear tray with screen printed polycarbonate legend panel Light output (mains) - 100lm 400lm Light output (emerg) 400lm 100lm - Battery 2.4V 4AH NiCd Charge 250mA normal Recharge period 24hours (14hrs for 1hr duration) Input voltage 230Volt +/-10% ~ 50Hz Power 9VA (max.) 21VA (max.) 13VA Dimensions (mm) Emergency 609

SYL Safe IP65 Polycarbonate body Clear Fresnel lens Ceiling or Wall mounted White flame retardant body and lens impact resistant Hinged gear tray for ease of installation and maintenance LIGHT SOURCE NOT INCLUDED (SELECTED MODELS) Syl-Safe LED Code Description Type 9144944 LED M3 Exit Box Surface Mount Syl-Safe IP65 Code Description Type 9136512 T5 8W Non-maintained 9136514 T5 8W Maintained LED M3 Exit Box Syl-Safe IP65 Self Test Code Description Type 9136513 T5 8W Non-maintained 9136515 T5 8W Maintained Recessing Kit Code Description 9136516 Recessing Kit Suspended Sign Kit Code Description Type Arrow down 9137000 Arrow down Single 9137003 Arrow down Double Arrow left 9137001 Arrow left Single 9137004 Arrow left Double Arrow right 9137002 Arrow right Single 9127005 Arrow right Double Dimensions (mm) 610 Emergency

Dublin airport - Dublin, Ireland