597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Similar documents
563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

697C (60 HZ) Sizes 018 thru 060

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

R4H4. Product Specifications

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

R4H4. Product Specifications

N4A6. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

WCH5**4. Product Specifications

N4H4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

A 14 SEER Heat Pump with R---410A Refrigerant Series

Product Data. Efficiency. S S Reliability

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

R 410A Ducted Horizontal Air Conditioner

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. Efficiency

Advance Product Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Installation Instructions

TECHNICAL SPECIFICATIONS

Product Data. Efficiency

PAJ3. Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. Fig. 1 - Unit 50VR -A

Advance Product Data

Advance Product Data

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Commercial High-Efficiency Condensing Units

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

Transcription:

ELECTRIC AIR CONDITIONER 597C (60 Hz) Sizes 018 thru 060 The Reliant AeroQuiet System (AQS) consists of 3 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and wire dome top results in quieter and more efficient operation. Energy-Efficient Fan and Fan Motor provide a slower fan motor, reducing noise and improving efficiency. Advanced Sound Hood to muffle noise from operation. Model 597C Energy-Efficient Air Conditioners incorporate innovative scroll compressor technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today including SEER ratings up to 14.0 when combined with specific Bryant equipment. All models are listed with UL, c-ul, ARI, CEC, and CSA-EEV. The 597C meets the Energy Star guidelines for energy efficiency. AVAILABLE OPTIONS DURAGUARD COIL PROTECTION Made of a coated steel wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental hits. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. ELECTRICAL RANGE All units are offered in 208/230-v single phase only. WIDE RANGE OF SIZES Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. WEATHER-PROTECTIVE CABINET Steel is galvanized and coated with a layer of zinc phosphate. A coat of modified polyester powder is then applied and baked on, providing each unit with a durable finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR Provides greater reliability under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. Then, under extreme conditions, the motor was tested and qualified to help ensure the greatest reliability. UNIT DESIGN Copper tube, enhanced aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt, and leaves. APPLICATION VERSATILITY The 597C can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, back seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. COMPRESSOR PROTECTION Each scroll compressor motor is protected with internal temperature and current-sensitive overloads. For improved serviceability, each compressor is equipped with a compressor terminal plug. SOUND HOOD A thick, sound dampening material wrapped around the compressor muffles operational noise. LIMITED WARRANTY Standard 1-year warranty on parts, with an additional 9-year warranty on compressor. Form No. PDS 597C.18.8

DIMENSIONS NOTES: 1. Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. 3. 4. Minimum outdoor operating ambient in cooling mode is 55 F (unless low-ambient control is used) max 125 F. Series designation is the 14th position of the unit model number. Center of gravity. AIR DISCHARGE L AIR IN 3/8-IN. DIA TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN C AIR DISCHARGE 2 1/2" 1 9/16" FIELD POWER SUPPLY CONN 7/8-IN. DIA HOLE WITH 1 1 /8-IN. DIA KNOCKOUT AND 1 3 /8-IN. DIA KNOCKOUT B AIR IN C L E D K FIELD CONTROL SUPPLY CONN 7/8-IN. DIA HOLE H DIA VAPOR LINE CONN 3/8-IN. DIA LIQUID LINE CONN F G A ACCESS PANEL 4 3 /16" 10 1/2" M AIR DISCHARGE 8 AIR IN 3 /16" N 1 1/4" 1 3/4" A97082 DIMENSIONS (IN.) UNIT UNIT DIMENSIONS MINIMUM MOUNTING SIZE SERIES A B C D E F G H K L M N PAD DIMENSIONS 018 F 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 5/8 9-1/4 17-3/8 13-1/2 2-3/8 20 x 27 024 F 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 5/8 16-1/2 20-3/8 11 2-15/16 26 x 32 030 F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32 036 F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32 042 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 048 G,F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 060 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 2

RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter (In.) Vapor Tube Diameter (In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 018, 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline. CHECK-FLO-RATER PISTON PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-F 55 024-F 61 030-F 036-F 76 042-F 82 048-G 90 048-F 93 060-F 101 *Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING ( F) 018-F 10 024-F 12 030-F 15 036-F 12 042-F 12 048-G,F 11 060-F 12 UNITARY AIR CONDITIONING As an ENERGY STAR Partner, Bryant Heating & Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. REGISTERED QUALITY SYSTEM 3

See notes on page 5. SPECIFICATIONS UNIT SIZE-SERIES 018-F 024-F 030-F 036-F 042-F 048-G/F 060-F Operating Weight (Lb) 149 187 197 197 207 261 265 ELECTRICAL Unit Volts Hertz Phase 208/230 60 1 208/230 60 1 208/230 60 1 208/230 60 1 208/230 60 1 208/230 1 60 208/230 1 60 Operating Voltage Range* 187 253 187 253 187 253 187 253 187 253 187 253 187 253 Compressor Rated Load Amps 10.0 11.4 15.0 17.9 20.0 23.7/19.9 28.8 Locked Rotor Amps 41.0 56.0 72.5 88.0 104.0 129.0/137.0 169.0 Condenser Fan Motor Full Load Amps 0.5 0.5 0.5 1.1 1.1 1.1 1.4 Min Unit Ampacity for Wire Sizing 13.0 14.8 19.3 23.4 26.0 30.5/26.0 37.4 Min Wire Size (60 C Copper) AWG 14 14 14 12 10 8/10 8 Min Wire Size (75 C Copper) AWG 14 14 14 12 10 10 8 Max Wire Length (60 C) (Ft) 61 53 39 52 77 77 82 Max Wire Length (75 C) (Ft) 58 50 37 50 73 61 78 Max Branch Circuit Fuse Size (Amps)** 20 20 30 40 40 50/40 60 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Type Scroll Temperature & Current Protection Internal Line Break Refrigerant Type R-22 Amount @ 15 Ft 4.25 5.25 6.25 6.25 7.00 10.50 11.00 CONDENSER COIL & FAN Coil Face Area (Sq Ft) 10.9 12.2 15.2 15.2 18.3 18.3 18.3 Fins Per In. Rows Circuits 25 1 2 25 1 2 25 1 3 25 1 3 25 1 4 20 2 5 20 2 6 Fan Motor PSC Type, HP & RPM 1/15 & 800 1/5 & 825 1/4 & 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 1500 2000 2000 3000 3000 3000 3300 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA Coastal Filter KAACF0101SML KAACF0201MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist PTC Type KAACS0201PTC TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB KAATX0601RPB KAATX0701RPB TXV (Hard Shutoff) KSATX0601HSO KSATX0701HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) P502-8163S (RCD) Evaporator Freeze Thermostat*** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control*** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 Low-Ambient Controller P251-0083 (RCD) MotorMaster Control 32LT660004 (RCD) Ball Bearing Fan Motor Not Available HC38GE231 (RCD) HC40GE232 (RCD) Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermidistat Control Programmable/ Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder s Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10 4

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 1 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz of refrigerant per ft of tube length in excess of 15 ft. Do not use hard shutoff TXV with LSV. *** See low-ambient controller Installation Instructions for application. Fan motor with ball bearings required. NOTES: 1. All motors/compressors contain internal overload protection. 2. Copper wire must be used from service disconnect to unit. 3. Control circuit is 24v on all units and requires external power source. 5

ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No Low Ambient Controller, MotorMaster Control, or Low-Ambient Pressure Switch Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV * For tubing line sets between 50 and 175 ft, refer to the Residential Split-System Long-Line Application Guideline. Only when low-pressure switch is used. Required for Low-Ambient Controller (full modulation feature) and MotorMaster Control only. No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shutoff expansion valve on indoor coil. Installations where Liquid-Line Solenoid Valve has been added. 4. Compressor Start Assist PTC Type Solid state electrical device which gives a soft boost to compressor motor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations. 6. Cycle Protector Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where Winter Start Control has been added. 8. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow. SUGGESTED USE: All split system air conditioners. 9. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 10. Liquid-Line Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor Start Assist Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain long line-applications. Refer to Residential Split System Long-Line Application Guideline. 6

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 11. Low-Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately 100 F high and 60 F low). The control will maintain working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 12. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control maintains working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 13. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on liquid side of refrigerant circuit. Cycles compressor off if refrigerant charge is lost. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to dirty air. All commercial installations. 14. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 15. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All corporate programmable thermostats. 16. Support Feet Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base minimizing corrosion. SUGGESTED USE: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound rating. 17. Thermostatic Expansion Valve (TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 18. Time-Delay Relay An SPST delay relay which briefly continued operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 19. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added. UNIT SIZE SOUND LEVEL (dba) SOUND POWER (dba) OCTAVE BAND CENTER FREQUENCY (Hz) 125 250 500 1000 2000 4000 8000 018 68 50.0 56.5 61.0 63.5 59.0 54.5 45.5 024 70 55.0 61.5.5 64.5 61.0 55.0 49.0 030 72 55.0 58.0 61.5 63.5.5 56.5 51.5 036 74 56.5 63.5 68.0 70.0 63.0 57.5 52.0 042 74 56.5 60.5 64.5.5 61.5 58.0 53.0 048 74 56.0 61.0.0.5 66.0 63.0 56.5 060 76 63.5 66.0 69.0 69.0 66.5 64.0 56.5 7

UNIT SIZE- SERIES 018-F 024-F See notes on page 13. INDOOR SECTION TOTAL CAP. BTUH COMBINATION RATINGS FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY CK5BA018* 17,400 NONE 12.00 12.00 12.00 11.05 CC5A/CD5AA018 17,400 NONE 12.00 12.00 12.00 11.05 CC5A/CD5AA024 17,800 NONE 12.20 12.20 12.20 11.25 CC5A/CD5AW024 17,800 NONE 12.20 12.20 12.20 11.25 CE3AA024 17,600 NONE 12.20 12.20 12.20 11.25 CK3BA024 17,800 NONE 12.20 12.20 12.20 11.25 CK5A/CK5BA024 17,800 NONE 12.20 12.20 12.20 11.25 CK5A/CK5BW024 17,800 NONE 12.20 12.20 12.20 11.25 F(A,B)4AN(F,C)018 17,000 TDR 12.00 12.00 10.95 F(A,B)4AN(F,C)024 17,600 TDR 12.50 12.50 11.45 FC4BNF024 17,600 TDR & TXV 12.50 11.45 FF1(B,C,D)NA018 17,000 TDR 12.20 12.20 11.30 FF1(B,C,D)NA024 17,600 TDR 12.20 12.20 11.30 FG3AAA024 17,400 NONE 12.00 12.00 12.00 11.05 FK4CNF001 18,000 TDR & TXV 14.00 12.85 FK4CNF002 18,000 TDR & TXV 14.00 12.95 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5AA018 17,000 TDR 13.50 13.50 12.30 CC5A/CD5AA024 17,600 TDR 14.00 14.00 12.65 CK3BA024 17,600 TDR 14.00 14.00 12.65 CK5A/CK5BA018 17,000 TDR 13.50 13.50 12.30 CK5A/CK5BA024 17,600 TDR 14.00 14.00 12.65 COILS + 355MAV042060 VARIABLE SPEED FURNACE CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.45 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.45 COILS + 355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.55 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.55 CC5A/CD5AA024* 23,000 NONE 12.00 12.00 12.00 10.85 CC5A/CD5AA030 23,200 NONE 12.20 12.20 12.20 10.95 CC5A/CD5AW024 23,000 NONE 12.00 12.00 12.00 10.85 CC5A/CD5AW030 23,200 NONE 12.20 12.20 12.20 10.95 CE3AA024 23,000 NONE 12.00 12.00 12.00 10.95 CE3AA030 23,200 NONE 12.20 12.20 12.20 11.10 CF5AA024 23,000 NONE 12.00 12.00 12.00 10.95 CK3BA024 23,000 NONE 12.00 12.00 12.00 10.85 CK3BA030 23,200 NONE 12.20 12.20 12.20 11.05 CK5A/CK5BA024 23,000 NONE 12.00 12.00 12.00 10.85 CK5A/CK5BA030 23,200 NONE 12.20 12.20 12.20 11.05 CK5A/CK5BW024 23,000 NONE 12.00 12.00 12.00 10.85 CK5A/CK5BW030 23,200 NONE 12.20 12.20 12.20 11.05 F(A,B)4ANF024 23,200 TDR 12.00 12.00 10.95 F(A,B)4ANF030 23,600 TDR 12.20 12.20 11.25 FC4BNF024 23,200 TDR & TXV 12.00 10.95 FC4BNF030 23,600 TDR & TXV 12.20 11.25 FF1(B,C,D)NA024 23,000 TDR 12.00 12.00 10.85 FF1(B,C,D)NA030 23,600 TDR 12.20 12.20 11.10 FG3AAA024 22,800 NONE 11.80 11.80 11.80 10.70 FK4BNF001 23,400 TDR & TXV 13.50 12.35 FK4BNF002 23,600 TDR & TXV 13.50 12.50 FK4BNF003 23,600 TDR & TXV 14.00 12.80 FK4BNF004 24,000 TDR & TXV 14.00 12.80 FK4CNF001 23,400 TDR & TXV 13.50 12.35 FK4CNF002 23,600 TDR & TXV 13.50 12.50 FK4CNF003 23,600 TDR & TXV 14.00 12.80 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.25 CE3AA030 23,600 TDR 13.50 13.50 12.35 CK3BA024 23,000 TDR 13.00 13.00 11.90 CK3BA030 23,200 TDR 13.50 13.50 12.15 CK5A/CK5BA024 23,000 TDR 13.00 13.00 11.90 CK5A/CK5BA030 23,200 TDR 13.50 13.50 12.15 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.15 COILS + 355MAV042040 VARIABLE SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90 CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20 CK3BA024 23,000 TDR 13.00 13.00 11.75 CK3BA030 23,200 TDR 13.00 13.00 12.05 CK5A/CK5BW030 23,200 TDR 13.00 13.00 12.05 COILS + 355MAV042060 VARIABLE SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90 CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20 CK3BA024 23,000 TDR 13.00 13.00 11.75 CK3BA030 23,200 TDR 13.00 13.00 12.00 CK5A/CK5BW024 23,000 TDR 13.00 13.00 11.75 CK5A/CK5BW030 23,200 TDR 13.00 13.00 12.00 COILS + 355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90 CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20 LLS EER 8

UNIT SIZE- SERIES 024-F 030-F See notes on page 13. INDOOR SECTION COMBINATION RATINGS Continued TOTAL CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY CK3BA024 23,000 TDR 13.00 13.00 12.00 CK3BA030 23,200 TDR 13.50 13.50 12.25 CK5A/CK5BW024 23,000 TDR 13.00 13.00 12.00 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.25 CC5A/CD5AA030* 29,000 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AA036 29,600 NONE 12.50 12.50 12.50 10.90 CC5A/CD5AW030 29,000 NONE 12.00 12.00 12.00 10.55 CD5AW036 29,600 NONE 12.50 12.50 12.50 10.90 CE3AA030 29,000 NONE 12.00 12.00 12.00 10.65 CE3AA036 29,600 NONE 12.20 12.20 12.20 10.80 CF5AA036 29,600 NONE 12.50 12.50 12.50 10.90 CK3BA030 29,000 NONE 12.00 12.00 12.00 10.60 CK3BA036 29,600 NONE 12.50 12.50 12.50 10.95 CK5A/CK5BA030 29,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA036 29,600 NONE 12.50 12.50 12.50 10.95 CK5A/CK5BN036 27,600 NONE 12.50 12.50 12.50 10.95 CK5A/CK5BW030 29,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BW036 29,600 NONE 12.50 12.50 12.50 10.95 F(A,B)4ANF030 29,200 TDR 12.00 12.00 10.70 F(A,B)4ANF036 29,600 TDR 12.00 12.00 10.65 FC4BNF030 29,200 TDR & TXV 12.00 10.70 FC4BNF036 29,600 TDR & TXV 12.00 10.65 FF1(B,C,D)NA030 29,600 TDR 12.00 12.00 10.70 FG3AAA036 29,400 NONE 12.00 12.00 12.00 10.70 FK4BNF001 29,600 TDR & TXV 13.00 11.45 FK4BNF002 29,600 TDR & TXV 13.40 11.55 FK4BNF003 30,000 TDR & TXV 13.80 12.10 FK4BNF004 30,200 TDR & TXV 14.00 12.00 FK4CNF001 29,600 TDR & TXV 13.00 11.45 FK4CNF002 29,600 TDR & TXV 13.40 11.55 FK4CNF003 30,000 TDR & TXV 13.80 12.10 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5A036 30,000 TDR 13.50 13.50 12.05 CE3AA036 29,800 TDR 13.50 13.50 11.80 CK3BA030 29,000 TDR 13.00 13.00 11.30 CK3BA036 29,600 TDR 13.50 13.50 11.85 CK5A/CK5BA030 29,000 TDR 13.00 13.00 11.30 CK5A/CK5BA036 29,600 TDR 13.50 13.50 11.85 CK5A/CK5BN036 27,600 TDR 13.00 13.00 11.70 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.30 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CC5A/CD5AA036 30,000 TDR 13.50 13.50 12.05 CE3AA036 29,800 TDR 13.50 13.50 11.80 CK3BA030 29,000 TDR 13.00 13.00 11.50 CK3BA036 29,600 TDR 13.50 13.50 12.00 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.50 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.00 COILS + 355MAV042040 VARIABLE SPEED FURNACE CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95 CK3BA030 29,000 TDR 12.50 12.50 11.10 CK3BA036 29,600 TDR 13.00 13.00 11.65 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.10 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.65 COILS + 355MAV042060 VARIABLE SPEED FURNACE CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95 CK3BA030 29,000 TDR 12.50 12.50 11.10 CK3BA036 29,600 TDR 13.00 13.00 11.65 CK5A/CK5BA036 29,600 TDR 13.00 13.00 11.65 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.10 COILS + 355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95 CK3BA030 29,000 TDR 12.50 12.50 11.20 CK3BA036 29,600 TDR 13.00 13.00 11.75 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.75 COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA030 29,000 TDR 12.50 12.50 11.05 CK3BA036 29,600 TDR 13.00 13.00 11.60 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.05 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.60 COILS + 355MAV060100 VARIABLE SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.45 CK3BA036 29,600 TDR 13.50 13.50 12.00 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.00 LLS EER 9

UNIT SIZE- SERIES 030-F 036-F See notes on page 13. INDOOR SECTION COMBINATION RATINGS Continued TOTAL CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING 10 SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY COILS + 355MAV060120 VARIABLE SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.40 CK3BA036 29,600 TDR 13.50 13.50 11.95 CK5A/CK5BW036 29,600 TDR 13.50 13.50 11.95 CC5A/CD5AA036* 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AA042 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW042 35,000 NONE 12.00 12.00 12.00 10.65 CD5AW036 35,000 NONE 12.00 12.00 12.00 10.75 CE3AA036 34,800 NONE 12.00 12.00 12.00 10.60 CE3AA042 35,400 NONE 12.20 12.20 12.20 10.80 CF5AA036 35,200 NONE 12.00 12.00 12.00 10.70 CK3BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK3BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BN036 33,000 NONE 11.50 11.50 11.50 10.50 CK5A/CK5BN042 34,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 35,000 NONE 12.00 12.00 12.00 10.75 F(A,B)4ANF036 35,000 TDR 12.00 12.00 10.65 F(A,B)4AN(F,B)042 35,400 TDR 12.00 12.00 10.70 FC4BNB054 36,000 TDR & TXV 13.00 11.45 FC4BNF036 35,000 TDR & TXV 12.00 10.65 FC4BN(F,B)042 35,400 TDR & TXV 12.00 10.70 FG3AAA036 34,600 NONE 11.80 11.80 11.80 10.50 FK4BNB005 36,000 TDR & TXV 14.00 12.10 FK4BNB006 36,000 TDR & TXV 14.00 12.35 FK4BNF001 35,000 TDR & TXV 12.20 10.95 FK4BNF002 35,000 TDR & TXV 12.50 11.00 FK4BNF003 35,400 TDR & TXV 13.00 11.60 FK4BNF004 35,400 TDR & TXV 13.00 11.40 FK4CNB006 36,000 TDR & TXV 14.00 12.35 FK4CNF001 35,000 TDR & TXV 12.20 10.95 FK4CNF002 35,000 TDR & TXV 12.50 11.00 FK4CNF003 35,400 TDR & TXV 13.00 11.60 FK4CNF005 36,000 TDR & TXV 14.00 12.10 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65 CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.45 CK3BA042 35,000 TDR 13.00 13.00 11.35 CK5A/CK5BA036 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BN036 33,000 TDR 12.50 12.50 11.65 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65 CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.75 CK3BA042 35,000 TDR 13.00 13.00 11.55 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.55 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.75 COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65 CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.75 CK3BA042 35,000 TDR 13.00 13.00 11.80 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.80 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.75 COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65 CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA042 35,000 TDR 13.00 13.00 11.75 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.75 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.65 COILS + 355MAV042040 VARIABLE SPEED FURNACE CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 12.50 12.50 11.35 CK3BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.35 COILS + 355MAV042060 VARIABLE SPEED FURNACE CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 12.50 12.50 11.35 CK3BA042 35,000 TDR 13.00 13.00 11.40 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.35 CK5A/CK5BN042 34,000 TDR 13.00 13.00 11.40 COILS + 355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 12.50 12.50 11.45 CK3BA042 35,000 TDR 13.00 13.00 11.50 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.50 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.45 LLS EER

UNIT SIZE- SERIES 036-F 042-F See notes on page 13. INDOOR SECTION COMBINATION RATINGS Continued TOTAL CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA036 35,000 TDR 12.50 12.50 11.30 CK3BA042 35,000 TDR 13.00 13.00 11.40 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.40 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.30 COILS + 355MAV060100 VARIABLE SPEED FURNACE CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.65 CK3BA042 35,000 TDR 13.00 13.00 11.65 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.65 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.65 COILS + 355MAV060120 VARIABLE SPEED FURNACE CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.65 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.60 CC5A/CD5AA042* 41,000 NONE 12.00 12.00 12.00 10.65 CC5A/CD5AC048 40,500 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW042 41,000 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW048 41,000 NONE 12.20 12.20 12.20 10.65 CD5AA048 41,000 NONE 12.20 12.20 12.20 10.65 CE3AA042 41,000 NONE 12.00 12.00 12.00 10.70 CE3AA048 41,500 NONE 12.20 12.20 12.20 10.75 CF5AA048 41,500 NONE 12.20 12.20 12.20 10.70 CK3BA042 41,000 NONE 12.00 12.00 12.00 10.65 CK3BA048 41,000 NONE 12.20 12.20 12.20 10.70 CK5A/CK5BA042 41,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BA048 41,000 NONE 12.20 12.20 12.20 10.70 CK5A/CK5BN042 40,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BN048 40,000 NONE 12.20 12.20 12.20 10.70 CK5A/CK5BW048 41,000 NONE 12.20 12.20 12.20 10.70 F(A,B)4AN(F,B)042 41,000 TDR 12.00 12.00 10.50 F(A,B)4AN(F,B)048 41,500 TDR 12.20 12.20 10.70 FC4BN(F,B)042 41,000 TDR & TXV 12.00 10.50 FC4BN(F,B)048 41,500 TDR & TXV 12.20 10.70 FC4BNB054 43,000 TDR & TXV 13.00 11.40 FG3AAA048 41,000 NONE 12.20 12.20 12.20 10.65 FK4BNB005 42,000 TDR & TXV 13.50 11.75 FK4BNB006 43,000 TDR & TXV 14.00 12.10 FK4BNF003 41,500 TDR & TXV 13.00 11.30 FK4CNB006 43,000 TDR & TXV 14.00 12.10 FK4CNF003 41,500 TDR & TXV 13.00 11.30 FK4CNF005 42,000 TDR & TXV 13.50 11.75 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CD5AA048 41,000 TDR 13.50 13.50 11.70 CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 12.50 12.50 11.20 CK3BA048 41,000 TDR 13.00 13.00 11.30 CK5A/CK5BA042 41,000 TDR 12.50 12.50 11.20 CK5A/CK5BA048 41,000 TDR 13.00 13.00 11.30 COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE CD5AA048 41,000 TDR 13.50 13.50 11.70 CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 13.00 13.00 11.45 CK3BA048 41,000 TDR 13.00 13.00 11.60 CK5A/CK5BA042 41,000 TDR 13.00 13.00 11.45 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.60 COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE CD5AA048 41,000 TDR 13.50 13.50 11.70 CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 13.00 13.00 11.45 CK3BA048 41,000 TDR 13.00 13.00 11.60 CK5A/CK5BA042 41,000 TDR 13.00 13.00 11.45 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.60 COILS + 355MAV042060 VARIABLE SPEED FURNACE CK3BA042 40,500 TDR 12.50 12.50 11.00 CK3BA048 41,000 TDR 12.50 12.50 11.15 CK5A/CK5BN042 40,000 TDR 12.50 12.50 11.00 CK5A/CK5BN048 40,000 TDR 12.50 12.50 11.05 COILS + 355MAV042080 VARIABLE SPEED FURNACE CC5A/CD5AA042 41,000 TDR 13.00 13.00 11.50 CD5AA048 41,000 TDR 13.50 13.50 11.65 CK3BA042 40,500 TDR 12.50 12.50 11.15 CK3BA048 41,000 TDR 12.50 12.50 11.15 CK5A/CK5BA042 40,500 TDR 12.50 12.50 11.15 CK5A/CK5BA048 41,000 TDR 12.50 12.50 11.15 LLS EER 11

UNIT SIZE- SERIES 042-F 048-G, F See notes on page 13. INDOOR SECTION COMBINATION RATINGS Continued TOTAL CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA042 40,500 TDR 12.50 12.50 11.00 CK3BA048 41,000 TDR 12.50 12.50 11.15 CK5A/CK5BA042 40,500 TDR 12.50 12.50 11.00 CK5A/CK5BA048 41,000 TDR 12.50 12.50 11.15 COILS + 355MAV060100 VARIABLE SPEED FURNACE CC5A/CD5AA042 41,000 TDR 13.00 13.00 11.50 CD5AA048 41,000 TDR 13.50 13.50 11.65 CK3BA042 40,500 TDR 13.00 13.00 11.35 CK3BA048 41,000 TDR 13.00 13.00 11.50 CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.35 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.50 COILS + 355MAV060120 VARIABLE SPEED FURNACE CK3BA042 40,500 TDR 13.00 13.00 11.30 CK3BA048 41,000 TDR 13.00 13.00 11.45 CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.30 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.45 *CC5A/CD5AA060 48,000 NONE 12.00 12.00 12.00 10.60 CC5A/CD5AC048 47,000 NONE 11.80 11.80 11.80 10.45 CC5A/CD5AW048 47,500 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW060 48,500 NONE 12.40 12.40 12.40 10.85 CD5AA048 47,500 NONE 12.00 12.00 12.00 10.55 CE3AA048 47,500 NONE 12.00 12.00 12.00 10.65 CE3AA060 48,000 NONE 12.40 12.40 12.40 10.90 CF5AA048 47,500 NONE 12.00 12.00 12.00 10.65 CK3BA048 47,500 NONE 12.00 12.00 12.00 10.60 CK3BA060 48,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BA048 47,500 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA060 48,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BN048 46,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BN060 48,000 NONE 12.00 12.00 12.00 11.00 CK5A/CK5BT048 47,500 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BT060 48,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BW048 47,500 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BX060 48,500 NONE 12.40 12.40 12.40 11.00 F(A,B)4AN(F,B,C)048 47,500 TDR 12.00 12.00 10.55 F(A,B)4AN(F,B,C)060 48,000 TDR 12.10 12.10 10.60 FC4BN(F,B)048 47,500 TDR & TXV 12.00 10.55 FC4BN(F,B)060 48,000 TDR & TXV 12.10 10.60 FC4BNB054 48,500 TDR & TXV 12.50 11.05 FC4BNB070 48,000 TDR & TXV 12.20 11.00 FG3AAA048 47,500 NONE 12.00 12.00 12.00 10.55 FG3AAA060 48,000 NONE 12.20 12.20 12.20 10.75 FK4CNB006 48,500 TDR 13.50 11.95 FK4CNF005 47,500 TDR 13.20 11.65 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CC5A/CD5AC048 46,000 TDR 12.00 12.00 10.60 CD5AA048 47,000 TDR 12.00 12.00 10.75 CK3BA048 47,000 TDR 12.00 12.00 10.80 CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.80 COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE CC5A/CD5AA060 47,000 TDR 13.00 13.00 11.30 CC5A/CD5AW048 47,000 TDR 12.50 12.50 11.20 CC5A/CD5AW060 48,500 TDR 13.00 13.00 11.65 CK3BA060 47,000 TDR 13.00 13.00 11.60 CK5A/CK5BA060 47,000 TDR 13.00 13.00 11.60 CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.25 CK5A/CK5BX060 48,500 TDR 13.00 13.00 11.85 COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.80 12.80 11.20 CC5A/CD5AW048 47,000 TDR 12.50 12.50 11.10 CC5A/CD5AW060 48,500 TDR 13.00 13.00 11.50 CK3BA048 47,000 TDR 12.80 12.80 11.45 CK5A/CK5BA060 47,000 TDR 12.80 12.80 11.45 CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.15 CK5A/CK5BX060 48,500 TDR 13.00 13.00 11.70 COILS + 355MAV042080 VARIABLE SPEED FURNACE CD5AA048 47,000 TDR 12.00 12.00 10.70 CK3BA048 47,000 TDR 12.00 12.00 10.75 CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.75 COILS + 355MAV060080 VARIABLE SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.00 12.00 10.65 CC5A/CD5AW060 48,000 TDR 12.50 12.50 10.95 CD5AA048 47,000 TDR 12.00 12.00 10.60 CK3BA048 47,000 TDR 12.00 12.00 10.65 CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.65 CK5A/CK5BA060 47,000 TDR 12.00 12.00 10.90 CK5A/CK5BX060 48,000 TDR 12.50 12.50 11.15 LLS EER 12

UNIT SIZE- SERIES INDOOR SECTION COMBINATION RATINGS Continued TOTAL CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR ACCESSORY TDR TXV ACCESSORY COILS + 355MAV060100 VARIABLE SPEED FURNACE CC5A/CD5AC048 46,000 TDR 12.00 12.00 10.65 CC5A/CD5AW060 48,000 TDR 12.80 12.80 11.25 CD5AA048 47,000 TDR 12.50 12.50 10.90 CK3BA048 47,000 TDR 12.50 12.50 10.95 CK3BA060 47,000 TDR 12.50 12.50 11.20 CK5A/CK5BA048 47,000 TDR 12.50 12.50 10.95 048-G, F CK5A/CK5BX060 48,000 TDR 12.80 12.80 11.45 COILS + 355MAV060120 VARIABLE SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.00 CC5A/CD5AW048 47,000 TDR 12.50 12.50 10.90 CC5A/CD5AW060 48,000 TDR 13.00 13.00 11.30 CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.25 CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.00 CK5A/CK5BX060 48,000 TDR 13.00 13.00 11.50 CC5A/CD5AW060* 57,000 NONE 12.00 12.00 12.00 10.30 CC5A/CD5AA060 55,000 NONE 12.00 12.00 12.00 10.20 CE3AA060 57,000 NONE 12.00 12.00 12.00 10.40 CK3BA060 55,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BA060 55,000 NONE 12.00 12.00 12.00 10.35 CK5A/CK5BN060 55,000 NONE 12.00 12.00 12.00 10.55 CK5A/CK5BX060 57,000 NONE 12.00 12.00 12.00 10.45 F(A,B)4AN(F,B)060 57,000 TDR 11.50 11.50 9.95 FB4ANB070 58,000 TDR 12.00 12.00 10.40 FC4BNB070 58,000 TDR & TXV 12.00 10.40 FC4BN(F,B)060 57,000 TDR & TXV 11.50 9.95 060-F FG3AAA060 FK4BNB006 57,000 58,000 NONE TDR & TXV 12.50 12.00 12.00 12.00 10.30 10.65 FK4CNB006 58,000 TDR & TXV 12.50 10.65 COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE CC5A/CD5AW060 57,000 TDR 12.50 12.50 10.75 CK3BA060 55,500 TDR 12.50 12.50 10.90 CK5A/CK5BA060 55,500 TDR 12.00 12.00 10.60 CK5A/CK5BX060 56,500 TDR 12.50 12.50 10.90 COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE CK3BA060 55,000 TDR 12.50 12.50 10.80 CK5A/CK5BA060 55,500 TDR 12.00 12.00 10.45 CK5A/CK5BX060 56,500 TDR 12.50 12.50 10.80 * Tested combination. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD. Based on computer simulation. Requires hard shutoff TXV. EER Energy Efficiency Ratio LLS Liquid-Line Solenoid Valve SEER Seasonal Energy Efficiency Ratio TDR Time-Delay Relay TXV Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. LLS EER 13

EVAPORATOR AIR CFM EWB See notes on page 21. DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Capacity MBtuh Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens 597CN018-F Outdoor Section With CK5A/CK5B018 Section Total System Kw** 72 19.5 9.60 1.40 18.8 9.33 1.58 18.0 9.05 1.77 17.2 8.75 1.98 16.3 8.44 2.21 525 17.8 16.2 12.1 14.6 1.38 1.37 17.1 15.6 11.9 14.3 1.55 1.54 16.4 14.9 11.6 14.0 1.74 1.72 15.6 14.3 11.2 13.6 1.95 1.93 14.8 13.5 10.9 13.2 2.17 2.16 57 15.6 15.6 1.36 15.1 15.1 1.54 14.5 14.5 1.73 14.0 14.0 1.93 13.4 13.4 2.16 72 19.8 10.0 1.44 19.1 9.74 1.61 18.3 9.45 1.80 17.4 9.16 2.01 16.5 8.84 2.25 600 18.1 16.6 12.8 15.5 1.41 1.40 17.4 15.9 12.6 15.2 1.58 1.57 16.7 15.2 12.3 14.8 1.77 1.76 15.9 14.6 11.9 14.4 1.98 1.97 15.0 13.8 11.6 13.8 2.21 2.20 57 16.1 16.1 1.39 15.6 15.6 1.56 15.0 15.0 1.75 14.5 14.5 1.96 13.8 13.8 2.19 72 20.0 10.4 1.46 19.2 10.1 1.63 18.4 9.81 1.82 17.6 9.51 2.03 16.7 9.19 2.26 5 18.3 16.8 13.5 16.4 1.44 1.43 17.6 16.2 13.2 16.0 1.61 1.60 16.9 15.5 12.9 15.5 1.80 1.79 16.1 14.9 12.6 14.9 2.01 2.00 15.2 14.2 12.3 14.2 2.24 2.23 57 16.6 16.6 1.43 16.0 16.0 1.59 15.5 15.5 1.78 14.8 14.8 1.99 14.2 14.2 2.22 Multipliers for Determining the Performance With Other Sections Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 018 1.00 1.00 FK4CNF 001 1.03 0.91 024 1.02 1.00 002 1.03 0.91 CC5A/CD5AW 024 1.02 1.00 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CE3AA 024 1.01 1.00 CC5A/CD5AA 018 0.98 0.90 CK3BA 024 1.02 1.00 024 1.01 0.90 CK5A/CK5BA 018 1.00 1.00 CK3BA 024 1.01 0.90 024 1.02 1.00 CK5A/CK5BA 018 0.98 0.90 CK5A/CK5BW 024 1.02 1.00 024 1.01 0.90 F(A,B)4AN(F,C) 018 0.98 0.98 COILS + 355MAV042060 VARIABLE SPEED FURNACE 024 1.01 0.99 CC5A/CD5AW 024 1.01 0.93 FC4BNF 024 1.01 0.99 CK5A/CK5BW 024 1.01 0.93 FF1(B,C,D)NA 018 0.98 0.96 COILS + 355MAV042080 VARIABLE SPEED FURNACE 024 1.01 1.00 CC5A/CD5AW 024 1.01 0.92 FG3AAA 024 1.00 1.00 CK5A/CK5BW 024 1.01 0.92 14

EVAPORATOR AIR CFM EWB See notes on page 21. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Capacity MBtuh Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens 597CN024-F Outdoor Section With CC5A/CD5AA024 Section Total System Kw** 72 25.7 12.6 1.88 24.8 12.3 2.09 23.8 11.9 2.31 22.7 11.5 2.5 21.6 11.1 2.84 700 23.4 15.9 1.89 22.6 15.5 2.09 21.6 15.1 2.31 20.7 14.7 2.5 19.7 14.3 2.82 21.3 19.1 1.89 20.5 18.7 2.09 19.6 18.2 2.30 18.7 17.8 2.5 17.8 17.3 2.82 57 20.3 20.3 1.89 19.6 19.6 2.09 18.9 18.9 2.30 18.2 18.2 2.5 17.5 17.5 2.82 72 26.1 13.2 1.92 25.2 12.8 2.13 24.2 12.5 2.35 23.1 12.1 2.6 22.0 11.7 2.88 800 23.9 21.8 16.8 20.3 1.92 1.93 23.0 20.9 16.5 19.9 2.13 2.13 22.0 20.0 16.1 19.4 2.35 2.34 21.0 19.1 15.7 18.8 2.6 2.5 20.0 18.2 15.3 18.2 2.86 2.86 57 21.1 21.1 1.93 20.4 20.4 2.12 19.7 19.7 2.34 18.9 18.9 2.5 18.1 18.1 2.87 72 26.5 13.7 1.96 25.6 13.3 2.17 24.5 13.0 2.39 23.4 12.6 2.6 22.2 12.2 2.92 900 24.2 22.1 17.7 21.4 1.96 1.97 23.3 21.3 17.4 20.9 2.17 2.17 22.3 20.4 17.0 20.3 2.39 2.38 21.3 19.5 16.6 19.5 2.6 2.6 20.2 18.7 16.2 18.7 2.90 2.91 57 21.8 21.8 1.96 21.1 21.1 2.16 20.3 20.3 2.38 19.5 19.5 2.6 18.7 18.7 2.90 Multipliers for Determining the Performance With Other Sections Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 024 1.00 1.00 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE 030 1.01 1.00 CC5A/CD5AA 030 1.03 0.90 CC5A/CD5AW 024 1.00 1.00 CE3AA 030 1.03 0.90 030 1.01 1.00 CK3BA 024 1.00 0.92 CE3AA 024 1.00 1.00 030 1.01 0.91 030 1.01 1.00 CK5A/CK5BA 024 1.00 0.92 CF5AA 024 1.00 1.00 030 1.01 0.91 CK3BA 024 1.00 1.00 CK5A/CK5BW 030 1.01 0.91 030 1.01 1.00 COILS + 355MAV042040 VARIABLE SPEED FURNACE CK5A/CK5BA 024 1.00 1.00 CC5A/CD5AA 024 1.01 0.93 030 1.01 1.00 030 1.03 0.92 CK5A/CK5BW 024 1.00 1.00 CK3BA 024 1.00 0.94 030 1.01 1.00 030 1.01 0.93 F(A,B)4ANF 024 1.01 1.00 CK5A/CK5BW 030 1.01 0.93 030 1.03 0.99 COILS + 355MAV042060 VARIABLE SPEED FURNACE FC4BNF 024 1.01 1.00 CC5A/CD5AA 024 1.01 0.93 030 1.03 0.99 030 1.03 0.92 FF1(B,C,D)NA 024 1.00 1.01 CK3BA 024 1.00 0.94 030 1.03 1.01 030 1.01 0.94 FG3AAA 024 0.99 1.00 CK5A/CK5BW 024 1.00 0.94 FK4BNF 001 1.02 0.93 030 1.01 0.94 002 1.03 0.93 COILS + 355MAV042080 VARIABLE SPEED FURNACE 003 1.03 0.90 CC5A/CD5AA 024 1.01 0.93 004 1.04 0.91 030 1.03 0.92 FK4CNF 001 1.02 0.93 CK3BA 024 1.00 0.92 002 1.03 0.93 030 1.01 0.92 003 1.03 0.90 CK5A/CK5BW 024 1.00 0.92 030 1.01 0.92 15

EVAPORATOR AIR CFM EWB See notes on page 21. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Capacity MBtuh Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens 597CN030-F Outdoor Section With CC5A/CD5AA030 Section Total System Kw** 72 32.3 15.8 2.37 31.0 15.3 2.68 29.8 14.8 3.04 28.4 14.3 3.4 27.0 13.8 3.86 875 29.6 27.0 19.8 23.8 2.39 2.41 28.5 25.9 19.4 23.3 2.71 2.73 27.3 24.8 18.9 22.8 3.07 3.09 26.0 23.7 18.3 22.2 3.4 3.4 24.6 22.4 17.8 21.5 3.86 3.86 57 25.6 25.6 2.43 24.8 24.8 2.75 23.9 23.9 3.09 22.9 22.9 3.4 22.0 22.0 3.88 72 32.8 16.4 2.40 31.6 15.9 2.72 30.3 15.5 3.08 28.9 15.0 3.4 27.4 14.4 3.92 1000 30.1 27.5 21.0 25.4 2.44 2.46 29.0 26.5 20.5 24.8 2.76 2.78 27.7 25.3 20.0 24.2 3.10 3.14 26.4 24.1 19.5 23.5 3.4 3.5 25.0 22.9 18.9 22.7 3.92 3.91 57 26.5 26.5 2.46 25.7 25.7 2.78 24.8 24.8 3.13 23.8 23.8 3.5 22.8 22.8 3.93 72 33.3 17.0 2.44 32.0 16.6 2.77 30.7 16.1 3.13 29.2 15.6 3.5 27.6 15.0 3.94 1125 30.6 28.0 22.1 26.7 2.48 2.50 29.3 26.9 21.6 26.1 2.79 2.83 28.1 25.7 21.1 25.4 3.15 3.17 26.7 24.5 20.5 24.5 3.5 3.5 25.3 23.4 20.0 23.4 3.97 3.97 57 27.4 27.4 2.50 26.4 26.4 2.81 25.5 25.5 3.17 24.5 24.5 3.5 23.4 23.4 3.98 Multipliers for Determining the Performance With Other Sections Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 030 1.00 1.00 CK3BA 030 1.00 0.93 036 1.02 1.00 036 1.02 0.91 CC5A/CD5AW 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.93 CD5AW 036 1.02 1.00 036 1.02 0.91 CE3AA 030 1.00 1.00 COILS + 355MAV042040 VARIABLE SPEED FURNACE 036 1.02 1.00 CC5A/CD5AA 030 1.02 0.94 CF5AA 036 1.02 1.00 036 1.03 0.93 CK3BA 030 1.00 1.00 CK3BA 030 1.00 0.96 036 1.02 1.00 036 1.02 0.95 CK5A/CK5BA 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.96 036 1.02 1.00 036 1.02 0.95 CK5A/CK5BN 036 0.95 1.00 COILS + 355MAV042060 VARIABLE SPEED FURNACE CK5A/CK5BW 030 1.00 1.00 CC5A/CD5AA 030 1.02 0.94 036 1.02 1.00 036 1.03 0.93 F(A,B)4ANF 030 1.01 0.99 CK3BA 030 1.00 0.96 036 1.02 1.01 036 1.02 0.95 FC4BNF 030 1.01 0.99 CK5A/CK5BA 036 1.02 0.95 036 1.02 1.01 CK5A/CK5BW 030 1.00 0.96 FF1(B,C,D)NA 030 1.02 1.00 COILS + 355MAV042080 VARIABLE SPEED FURNACE FG3AAA 036 1.01 1.00 CC5A/CD5AA 030 1.02 0.94 FK4BNF 001 1.02 0.96 036 1.03 0.93 002 1.02 0.96 CK3BA 030 1.00 0.96 003 1.03 0.92 036 1.02 0.94 004 1.04 0.93 CK5A/CK5BW 030 1.00 0.96 FK4CNF 001 1.02 0.96 036 1.02 0.94 002 1.02 0.96 COILS + 355MAV060080 VARIABLE SPEED FURNACE 003 1.03 0.92 CK3BA 030 1.00 0.97 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE 036 1.02 0.95 CC5A/CD5AA 036 1.03 0.91 CK5A/CK5BW 030 1.00 0.97 CE3AA 036 1.03 0.92 036 1.02 0.95 CK3BA 030 1.00 0.94 COILS + 355MAV060100 VARIABLE SPEED FURNACE 036 1.02 0.93 CK5A/CK5BW 030 1.00 0.94 CK5A/CK5BA 030 1.00 0.94 036 1.02 0.93 036 1.02 0.93 CK3BA 030 1.00 0.94 CK5A/CK5BN 036 0.95 0.94 036 1.02 0.93 CK5A/CK5BW 030 1.00 0.94 COILS + 355MAV060120 VARIABLE SPEED FURNACE COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CK3BA 030 1.00 0.94 CC5A/CD5AA 036 1.03 0.91 036 1.02 0.93 CE3AA 036 1.03 0.92 CK5A/CK5BW 036 1.02 0.93 16

EVAPORATOR AIR CFM EWB See notes on page 21. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Capacity MBtuh Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens Kw** Total Sens 597CN036-F Outdoor Section With CC5A/CD5AA036 Section Total System Kw** 72 39.0 19.3 2.91 37.6 18.7 3.23 35.9 18.1 3.56 34.2 17.5 3.9 32.5 16.9 4.36 1050 35.8 32.7 24.5 29.4 2.89 2.87 34.4 31.4 23.9 28.8 3.21 3.19 32.8 30.0 23.2 28.1 3.53 3.51 31.3 28.6 22.6 27.4 3.9 3.8 29.7 27.1 22.0 26.5 4.32 4.29 57 31.3 31.3 2.87 30.3 30.3 3.18 29.2 29.2 3.51 28.0 28.0 3.8 26.9 26.9 4.29 72 39.7 20.2 2.97 38.2 19.6 3.29 36.5 19.0 3. 34.8 18.4 4.0 32.8 17.7 4.40 1200 36.4 33.4 26.0 31.4 2.95 2.94 35.0 32.0 25.4 30.7 3.27 3.24 33.4 30.6 24.7 29.9 3.60 3.59 31.8 29.1 24.1 28.9 3.9 3.9 30.2 27.8 23.5 27.8 4.39 4.34 57 32.5 32.5 2.93 31.4 31.4 3.25 30.3 30.3 3.58 29.0 29.0 3.9 27.8 27.8 4.35 72 40.3 21.0 3.03 38.5 20.4 3.33 36.9 19.8 3.69 35.1 19.2 4.0 33.2 18.5 4.47 1350 36.9 33.9 27.4 33.1 3.01 3.00 35.3 32.5 26.7 32.2 3.31 3.29 33.8 31.2 26.2 31.2 3.66 3.64 32.2 29.9 25.5 29.9 4.0 4.0 30.3 28.5 24.8 28.5 4.42 4.40 57 33.5 33.5 2.99 32.4 32.4 3.31 31.2 31.2 3.64 29.9 29.9 4.0 28.5 28.5 4.40 Multipliers for Determining the Performance With Other Sections Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.00 1.00 CE3AA 042 1.01 0.93 042 100 1.00 CK3BA 036 1.00 0.92 CC5A/CD5AW 042 1.00 1.00 042 1.00 0.93 CD5AW 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.93 CE3AA 036 0.99 1.00 CK5A/CK5BW 036 1.00 0.92 042 1.01 1.00 COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE CF5AA 036 1.01 1.00 CC5A/CD5AA 042 1.01 0.93 CK3BA 036 1.00 1.00 CE3AA 042 1.01 0.93 042 1.00 1.00 CK3BA 036 1.00 0.92 CK5A/CK5BA 036 1.00 1.00 042 1.00 0.92 042 1.00 1.00 CK5A/CK5BA 042 1.00 0.92 CK5A/CK5BN 036 0.94 1.00 CK5A/CK5BW 036 1.00 0.92 042 0.97 1.00 COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE CK5A/CK5BW 036 1.00 1.00 CC5A/CD5AA 042 1.01 0.93 F(A,B)4ANF 036 1.00 1.00 CE3AA 042 1.01 0.93 F(A,B)4AN(F,B) 042 1.01 1.01 CK3BA 042 1.00 0.92 FC4BNF 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.92 FC4BN(F,B) 042 1.01 1.01 CK5A/CK5BW 036 1.00 0.92 FC4BNB 054 1.03 1.00 COILS + 355MAV042040 VARIABLE SPEED FURNACE FG3AAA 036 0.99 1.00 CC5A/CD5AA 036 1.01 0.92 FK4BNF 001 1.00 0.98 042 1.01 0.92 002 1.00 0.98 CK3BA 036 1.00 0.94 003 1.01 0.93 042 1.00 0.93 004 1.01 0.95 CK5A/CK5BA 042 1.00 0.93 FK4BNB 005 1.03 0.94 CK5A/CK5BW 036 1.00 0.94 006 1.03 0.93 COILS + 355MAV042060 VARIABLE SPEED FURNACE FK4CNB 006 1.03 0.93 CC5A/CD5AA 036 1.01 0.92 FK4CNF 001 1.00 0.98 042 1.01 0.92 002 1.00 0.98 CK3BA 036 1.00 0.94 003 1.01 0.93 042 1.00 0.94 005 1.03 0.94 CK5A/CK5BA 036 1.00 0.94 COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CK5A/CK5BN 042 0.97 0.94 CC5A/CD5AA 042 1.01 0.93 COILS + 355MAV042080 VARIABLE SPEED FURNACE CE3AA 042 1.01 0.93 CC5A/CD5AA 036 1.01 0.92 CK3BA 036 1.00 0.94 042 1.01 0.92 042 1.00 0.94 CK3BA 036 1.00 0.93 CK5A/CK5BA 036 1.00 0.94 042 1.00 0.93 CK5A/CK5BN 036 0.94 0.93 CK5A/CK5BA 042 1.00 0.93 COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CK5A/CK5BW 036 1.00 0.93 CC5A/CD5AA 042 1.01 0.93 17