Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

Similar documents
Air Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001

Real-time Monitoring Technology for Preservation Environment of Archives

Active Dry Air Venting for Water Contamination Control

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

Introduction to Control Technology

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

HEALTHY CLIMATE PureAir Air Purification System

PM2.5. Summary of MEDAIR 4 Models. Air Treatment Unit Indoor Air Quality solution specialist

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

Recent Improvements in Process GC Instrumentation

STABILITY ICH. ICH Stability Tests

Classic i series Intelligent air purifier

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Chemistry Instrumental Analysis Lecture 29. Chem 4631

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

Research Report of the Institute of Hygiene, University of Heidelberg, Germany published during the proceedings of the

Latest developments in TPO stabilization for Automotive applications ANTEC MAY 8-10 TH 2017 ANAHEIM, CA

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Thermo Scientific TVA2020 Introduction

Sensor Suite Sensors. Sensor Suite Sensors: Overview. Ordering Guide. Overview FEATURES

Properly designed economical engineering controls reduce chemical migration outside the spray area reduce re-occupancy time to less than 24 hours

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

DS Series. Ultraaqua Autoclean. Oil/Water Separators

Thermo Scientific Model 1160 Principle of Operation

Welcome to the IQAir revolution.

Complex Solid Waste Air Permitting Issues

UV Weather Resistance Test Chambers

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

There is Still Something in the Air Consumer Reports Article Raises New Concerns About Ionizers. By Jim Rosenthal, CAFS and Stevan Brown, CAFS

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

MEDAIR Guarantee and Warranty MEDAIR consumable parts provide guarantee and 5 years machine warranty

Mobile Transformer Oil Purification Plant

EXTINGUISHING SYSTEM DETECTION AND CONTROL

IOA/PAG AIR TREATMENT TASK FORCE USER SUCCESS REPORT

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

PREDICTING GASEOUS AIR CLEANER PERFORMANCE IN THE FIELD

Monitoring Nutrition for Crops

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

by Owner s Manual For use with model: AA250 For safety and to ensure proper use carefully read the contents of this manual before operating the unit.

Datalogging as standard

NT-40 Ozone Interceptor Owner s Manual

Hybrid Refrigerated/Desiccant Compressed Air Dryers

VOCs in soil remediation

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

Emis. Unit Description:

COMPLIANCE INSPECTION CHECKLIST. Date: 5/14/2011 Time In: 12:30PM Time Out: 1:00PM

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

F-900 Portable Ethylene Analyzer

Evaluating Low Impact Development Practices for Stormwater Management on an Industrial Site in Mississippi

Operate the Mutli-Gas Monitor PID

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Methods for measuring deep drainage

For sales and service in Australia & NZ, contact:

WHAT YOU DON T SEE CAN HURT YOU. KenkoAir Purifier

Innovation in air purification unmatched air quality

COMPLIANCE INSPECTION CHECKLIST. Date: 12/20/12 Time In: 1:00PM Time Out: 1:30PM

Frequently Asked Questions

with plasma ioniser and Remote Control USER MANUAL

intrinsically safe detector for hydrocarbon gases

FITOCLIMA 600 & 1200 STABILITY

Owners Manual Model: XXL

PureAir Air Purification System PCO-12C/20C

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

ECOSENSORS 2015 PRICE LISTr-2 PORTABLE AND FIXED AMBIENT OZONE SENSORS

Experience just how clean your indoor air can be

HEPASilent Air Purification Systems. Clean air is a human right

Blueair Sense+ User Manual

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

Three Rivers Park District Administration Center Rain Garden

FITOCLIMA 600 & 1200 PHARMA

Pure air. Because Daikin cares

Brine Generation Study

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

AO BP2400. Product Sheet By Air Oasis. Air Oasis, LLP 3401 Airway Blvd Amarillo Tx 79118

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Desiccant Breathers: A Front Line Defense in the War on Contamination

CLIMATRON GROWTH CABINETS

AIREX 2S WOOD PYROLYSIS SUCKING FAN

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E

Sludge Dryer Wet Scrubber Used to Produce Renewable Energy

3 3SP_O3_5 C Package

Delivering More Clean Air, At a Faster Rate With Less Noise

The Louis Berger Group, Inc. 15 January 2016

Supplying Clean Air to Industry

HEALTH. Particles. Chemicals

RLDS - Remote LEAK DETECTION SYSTEM

Transcription:

Cover Sheet Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. PURPOSE: Some earlier generation air purifiers, have been shown to release ozone or secondary pollutants into the air as byproducts. An independent team of researchers at the University of Minnesota was provided with a Molekule device to test whether ozone was produced during the complete degradation of VOCs, as opposed to a partial degradation that other technologies are capable of. SET-UP: An environment with artificially high levels of acetone (a VOC) was created and the Molekule device was allowed to run and degrade the acetone. An ozone sensor measured any levels of ozone production from running the device. In a separate test, Ozone was generated to artificially high levels in a chamber containing a Molekule device and the device was allowed to run. RESULT: The acetone was reduced to extremely low levels within a few hours, and no production of ozone by the Molekule technology was detected. When ozone was artificially generated in a separate chamber, it was determined that ozone was in fact degraded by the Molekule nanotechnology, within 12-18 minutes of the device running. Activated carbon filters, which were also tested, initially demonstrated similar results. However after reaching a point of saturation the carbon filter started releasing harmful VOCs back into the environment.

UNIVERSITY OF MINNESOTA Twin Cities Campus Department of Mechanical Engineering Particle Calibration Laboratory College of Science & Engineering 1100 Mechanical Engineering 111 Church Street SE, #3101 Minneapolis, MN 55455-0111 Telephone: (612) 625-7807 Facsimile: (612) 625-6069 Testing of a Photo-electrochemical Oxidation (PECO) Air Purifier for Generation of Secondary Pollutants and Testing of an Activated Carbon Filter for Outgassing Final Report Submitted to: Yogi Goswami, Ph. D. Chief Science & Technology Officer Molekule, LLC 3802 Spectrum Blvd. Suite 143 Tampa, FL 33612 Submitted by: Bernard Olson, Ph. D. Particle Calibration Laboratory Director University of Minnesota 111 Church St. S.E. Minneapolis, MN 55455 May 12, 2016

INTRODUCTION A photo-electrochemical oxidation (PECO) air purifier provided by Molekule was tested at the University of South Florida Clean Energy Research Center to determine if it generated secondary total volatile organic compounds (TVOCs) pollutants. The tests were carried out in a sealed stainless steel test chamber with the PECO air purifier placed inside of it. The chamber was equipped with sensors for measuring TVOCs, ozone, relative humidity and temperature. For the first stage of testing, acetone was introduced into the chamber and the TVOCs and ozone concentrations were monitored over time to determine if the PECO air purifier was generating any secondary pollutants. A second stage of testing was then performed where an ozone generator was placed in the chamber and artificially high ozone concentrations generated at the onset of testing to determine its effect on the performance of the PECO air purifier. In addition to testing the PECO air purifier, an activated carbon air filter was tested in the chamber to determine its adsorbing and off-gassing characteristics by introducing acetone into the chamber and monitoring the TVOC concentrations over time. TEST METHODS The photo-electrochemical oxidation (PECO) air purifier tested consists of an array of 30 3500 A o UV-A LEDs having an average UV intensity of 100W/m 2 at the filter, a pleated fiber filter having a proprietary catalyst coating with a cross-sectional area of 34 cm x 23 cm (13.5 in. x 9 in.) and a blower. Air enters through the bottom of the purifier and flows around the LEDs and through the filter mounted just downstream from them. The assembly is mounted in a sheet metal enclosure with a blower attached on top of it to draw air through the system. The flow rate through the blower was estimated to be 300 lpm (10 cfm). Figures 1, 2 and 3 show the components of the PECO air purifier mounted in the chamber. A stainless steel sealable test chamber with internal volume of approximately 600 liters (see Figure 4) was used to test the PECO air purifier for potential secondary TVOC and ozone pollutants. As shown in Figure 5, the chamber was equipped with two Grey Wolf sensor probes, 1

Figure 1. Photograph of PECO air purifier showing illuminated UV LEDs at the base of the system. Figure 2. Photograph of PECO air purifier showing the pleated filter containing a proprietary catalyst placed directly above the UV LEDs. 2

Figure 3. Photograph of PECO air purifier assembly mounted inside sheet metal enclosure with a blower connected to the exhaust side of the system on top of the enclosure. one with a photo-ionization (PID) detector for TVOCs, relative humidity sensor and temperature sensor (model TG-502L) and the other probe with an ozone sensor and temperature sensor (model TG-501). The PID detector had a detection limit of 5 parts per billion (ppb) and a sensitivity of 1 ppb, the ozone sensor had a detection limit of 0.02 ppm and a sensitivity of 0.01 ppm, and the relative humidity and temperature sensors have accuracies of +/-2% and +/-0.3 C, respectively, within the operating ranges used for testing. The cables from the probes fed through a small hole in the top of the chamber that was sealed and the cables were connected to a Gray Wolf Advanced Sense environmental test meter (Figure 6) for data logging and subsequent retrieval. An auxiliary fan was placed in the chamber to circulate and provide uniform gas mixing. For the first stage of testing, the PECO air purifier was placed in the chamber, connected to power and turned on to ensure that all the UV LEDs and the blower were working properly. The PECO device was then turned off and the chamber door was shut and sealed. Subsequently, 3

Figure 4. Photograph of stainless steel test chamber having dimensions of 81.3 cm 81.3 cm 91.4 cm (32 in 32 in 36 in) with an internal volume of 600 liters. Figure 5. Photograph of two sensor probes containing PID, ozone, relative humidity and temperature sensors mounted behind PECO air purifier in test chamber. 4

2 ul of acetone was injected into the chamber injection port to provide roughly 1 ppmv of acetone gas at room temperature and the air purifier was turned on. Total VOC and ozone concentrations were then monitored to determine if the PECO air purifier was generating secondary pollutants over time. A second stage of testing was then performed to determine the effect of highly elevated ozone concentrations on the PECO air purifier. A Foreverozone 3500 mg/h solid state ozone generator was placed inside the chamber next to the PECO device as shown in Figure 7. The chamber door was then shut and sealed, and the humidity in the chamber was lowered from room air levels of approximately 45% by placing a tray of saturated salt solution in the chamber following ASTM Standard E.104-02. Once the relative humidity equilibrated at 16% the ozone generator was turned on and ran for approximately 3 to 4 seconds to generate artificially high ozone concentrations of approximately 3.0 ppm, which was well above room air ozone concentrations being around 0.07 to 0.08 ppm. Ozone concentrations with the PECO air purifier off was monitored for approximately 10 minutes and then the PECO device was turned on and the ozone concentrations continued to be monitored for approximately 30 minutes more until the ozone concentrations came to steady-state. A test was then performed to determine the TVOC capture and retention of an activated carbon filter media (Grainger, model number 5W095) with filter dimensions of 34 cm x 23 cm x 0.64 thick (13.5 in. x 9 in. x 0.25 in.) as shown in Figure 8. The filter was mounted in the PECO enclosure replacing the filter with proprietary catalyst and the chamber door was shut and sealed. A syringe containing 2 ul of acetone was then injected into the chamber and the blower was turned on to flow air through the filter at approximately 300 lpm. The TVOC concentration was then monitored and after approximately 100 minutes once the concentration started to stabilize indicating saturation, the chamber door was opened exposing the activated carbon filter to room air for approximately 15 minutes. The door was then shut and sealed and the TVOC concentrations continued to be monitored for another 45 minutes to determine if outgassing was occurring. 5

Figure 6. Photograph of Grey Wolf Advanced Sense Environmental Test Meter and Data Logger with the two cables connected to it from sensor probes inside the test chamber. Figure 7. Foreverozone 3500 mg/h solid state ozone generator mounted inside test chamber. 6

Figure 8. Photograph of 34 cm x 23 cm x 0.64 cm thick activated carbon filter. RESULTS The results of the first series of testing is shown in Figure 9 where 2 ul of acetone was introduced into the test chamber at the beginning of the test. Prior to the test the room air TVOC concentration was 44 ppb, and the initial TVOC concentration after the acetone injection was just over 800 ppb. The concentration then depleted to less than 150 ppb after 6 hours, and was continuing on a downward trend indicating that the PECO air purifier was not generating secondary pollutants. An exponential equation was fit to the data having an R 2 value of 0.9998 as shown in Figure 9. By extrapolation based on the curve fit, the TVOC concentration would have dropped to approximately 44 ppb after 10 hours assuming TVOCs would have continued to decrease at the same rate. In addition, the initial ozone concentration was the same as room air being 0.07 ppm and decreased to 0.05 ppm over the same 6 hour period. Note that the ozone detector sensitivity is 0.01 ppm which is why the ozone concentration decreased in 0.01 ppm increments with time. For the second series of testing a plot of ozone concentration versus time is shown in Figure 10 for the first test trial, where the ozone generator was operated for approximately 3 seconds at the beginning of the test. The initial ozone concentration was 2.33 ppm and after 10 minutes the concentration had degraded to 1.66 pp when the PECO air purifier was turned on. 7

Ozone degradation then took place at a higher rate and subsequently decayed and came to steady-state around 0.08 ppm after approximately 12 minutes. For the second trial, the ozone generator was turned on for approximately 4 seconds and the initial ozone concentration was 3.02 ppm. After 10 minutes the PECO air purifier was turned on where the ozone concentration had dropped to 2.11 ppm. Again ozone degradation occurred at a higher rate and leveled off after 18 minutes when the ozone concentration was at 0.08 ppm. A plot of ozone concentration versus time for the second trial is shown in Figure 11. Both trials demonstrated that ozone degraded with time and took place at a higher rate when the PECO air purifier was operating and reduced to background room air concentrations over time. Finally, an activated carbon filter test was performed where, after an initial injection of 2 ul of acetone into test chamber, the TVOC concentration was approximately 750 ppb as shown in Figure 12. TVOCs then decreased and started to level off at 145 ppb demonstrating that the gas adsorbed onto the filter and was saturating. After about 100 minutes the door chamber was opened causing room air infiltration into the chamber. The door remained open for about 20 minutes where the concentration decreased to 42 ppb and then it was shut and sealed again. The TVOC concentration subsequently increased to 130 ppm after 30 minutes demonstrating that outgassing was occurring. CONCLUSIONS The results demonstrated that the photo-electrochemical oxidation air purifier did not generate secondary TVOCs when challenged with an initial concentration of approximately 800 ppb of acetone gas, and it was effective at degrading ozone even at artificially high concentration levels of between 2 to 3 ppm. Furthermore, the PECO device was effective in reducing TVOC concentrations significantly, and degrading background room air ozone concentrations to even lower levels and high concentrations of ozone to background levels over the time periods tested. An activated carbon filter was challenged with approximately 750 ppm of acetone gas, and while it adsorbed the gas reducing TVOC concentrations, outgassing occurred after it became saturated. 8

0.08 900 0.07 0.06 Ozone TVOC 800 700 Ozone (ppm) 0.05 0.04 0.03 0.02 y = 819.31e 0.291x R² = 0.9998 600 500 400 300 200 TVOC (ppb) 0.01 100 0 0 1 2 3 4 5 6 7 Time (h) 0 Figure 9. Plot of TVOC and ozone concentrations over time with PECO operating inside test chamber after an initial injection of 2 ul of acetone into the chamber. 9

2.50 Ozone generator activated (3 s) Trial 1 2.00 PECO begins Ozone (ppm) 1.50 1.00 0.50 0.00 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Time (h) Figure 10. Ozone test trial 1 of PECO air purifier showing initial ozone concentration of 2.33 ppm after generator was activated for 3 seconds, PECO started after 10 minutes where the concentration was 1.66 ppm and then decreasing to 0.08 ppm after approximately 12 minutes. 10

3.50 3.00 Ozone generator activated (4 s) Trial 2 2.50 PECO begins Ozone, ppm 2.00 1.50 1.00 0.50 0.00 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 Time, hr Figure 11. Ozone test trial 2 of PECO air purifier showing initial ozone concentration of 3.02 ppm after generator was activated for 4 seconds, PECO turned on after 10 minutes where the ozone concentration was 2.11 ppm and decreasing to 0.08 ppm after approximately 18 minutes. 11

800 700 2ul acetone injection 600 TVOC (ppb) 500 400 300 200 Clean air infiltration 100 Restart carbon filtration 0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Time (h) Figure 12. Testing of activated carbon filter showing TVOC concentration after injection of 2 ul of acetone into test chamber, depletion of TVOC with time and subsequent out-gassing after clean air infiltration by opening chamber door and then shutting and sealing it again. 12