VEX250H with rotary heat exchanger and EXact control system

Similar documents
VEX280H with rotary heat exchanger and EXact control system

CONTENT: VEX300C Ceiling units VEX320C/330C

EXact Control System Basic instructions for the VEX200 series

CONTENT: VEX308 Decentralised ventilation VEX308

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

VEX100 series Air handling units with cross-flow heat exchanger

VEX350 / VEX360 Air handling units with counter flow heat exchangers

HEAT RECOVERY AIR HANDLING UNIT

TopMaster Air Handling unit. Installation instructions

GLEB Kitchen exhaust fan

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Air Handling Units. Danvent DV 190 and

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Topvex SR03, SR04, SR06 Compact Air Handling Unit

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

TopMaster Air Handling unit. Technical data

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Topvex SF02-SF12 Air Handling Unit

CLIMASTER ZCF AIR HANDLING UNITS

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Series VENTS VUT R WH ЕС

Danvent DV 190 and 240

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

English CNA-CNB. Centrifugal fans Installation and maintenance

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

XB-EFA-8L-BK & XB-EFA-8R-BK

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Novenco Air Handling Units

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

VERSO Air Handling Units

VETO CLEANER 500 FLUE GAS CLEANER

DANVENT CATALOGUE 1999

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Instructions for the BASIC BCRW Fan, Sizes General

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

Vacuum cleaner Instruction manual

Centrifugal Fans, Non-Overloading, Backward Inclined

GOLD RX, GOLD RX 12 GOLD RX,

Cooling Coil VEX100 CCW VEX100 CCW-HK VEX200 CCW VEX200 CCW-HK VEX100 VEX200. Product Information

USER S MANUAL. VKP Series INLINE FAN

Climaster ZerAx. Eco-designkrav. Climaster ZerAx type ZCN-M guide GB

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

List of alarms and menus for VEX fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Air Handling Units. Geniox. Quick guide

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

AZN ATEX INSTALLATION AND MAINTENANCE

Operation and maintenance instructions

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

VERSO Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

ACTIVA SERIES ROOF TOP Air Conditioners 017/040

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

WHHR Midi & Midi Lite

Air heater/cooler in combination with ground source heat pump

FUN I / FUN U FUN I MCP / FUN U MCP FUN V / FUN V MCP

HEAT RECOVERY VENTILATOR

TURBO HOODS. Product Brochure

INSTALLATION, OPERATION & MAINTENANCE MANUAL

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

CENTRIFUGAL CEILING EXTRACT FAN

TopVent Design Handbook

AHU INSTALLATION & OPERATION MANUAL

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

lindab we simplify construction Lindab Modular air handling units Service and maintenance manual

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System

G Installation manual Solitude - dmev unit

ACN SMOKE INSTALLATION AND MAINTENANCE

DVU-HP. Integrated Reversible Heat Pump System

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Use and Care Manual. MODELS H VAR 1.5 THRU 5 TON 13 Seer Split System Heat Pump REV. 4/06

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

KOMFORT EC DB Suspended heat recovery air handling units

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Transcription:

3003433-2014-04-11 VEX250_EXact VEX250H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): Compact filter FP Filter bag FB Trim damper and blowout zone,tb250 The following accessories are supplied separately: HCW external heating coil (water) HCE external heating coil (electrical) Closing damper, LS400-24, (LSA exhaust) Closing damper, LS400-24, (LSF outdoor) Closing damper, LSR400-24, with spring-return (LSFR outdoor) pieces, Fire thermostat, BT40 pieces, Fire thermostat, BT50 pieces, Fire thermostat, BT70 pieces, HMI control panel pieces, MIO-PIR motion sensor pieces, MPT-DUCT constant pressure control MIO-RH humidity sensor MIO-CO2-ROOM, CO 2 -sensor MIO-CO2-DUCT, CO 2 -sensor MIO-TS-DUCT temperature sensor MIO-TS-ROOM, temperature sensor MXCU control for external cooling unit Prod.order no.: Sales order no.: Product information...chapter 1 + 6 Mechanical assembly...chapter 2 + 3 Electrical installation...chapter 4 Maintenance...Chapter 5 Original instructions EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk

3003433-2014-04-11 1. Product information 1.1. Model overview...5 Model overview...5 1.2. Terms used in these instructions...7 1.3. Application...8 1.4. Location requirements...8 1.4.1. Spatial requirements...8 1.4.2. Requirements for underlying surface...9 1.4.3. Requirements for duct system...9 1.5. Description...10 1.5.1. The VEX unit design...10 1.6. Principal dimensions...13 VEX250, V1...13 VEX250, V2...14 2. Handling 2.1. Unpacking...15 2.2. Transport...15 2.2.1. Weight...16 2.2.2. Passage through openings...16 2.2.3. Internal transport with reduced weight...17 3. Mechanical assembly 3.1. Installing the unit...19 3.1.1. Installed directly onto the floor...19 3.1.2. Installing on mounting base...19 4. Electrical installation 4.1. Electrical installation...20 5. Maintenance 5.1. Operating readings via the HMI panel...21 5.2. Maintenance chart...21 5.3. Service...22 5.3.1. Filter replacement...22 5.3.2. Servicing and cleaning...22 6. Technical data 6.1. Weight, corrosion class, temperature range, etc...24 6.2. Compact filters...26 6.3. Bag filters...27 6.4. Capacity diagram...28 6.4.1. Unit with compact filter...28 6.4.2. Unit with bag filter...29 6.5. Ordering spare parts...29 6.6. EC Declaration of Conformity...30 2/32

3003433-2014-04-11 Symbols, terms and warnings Prohibition symbol Failure to observe instructions marked with a prohibition symbol may result in serious or fatal injury. Danger symbol Failure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the unit. Scope This instruction manual is for use with EXHAUSTO VEX-type air handling units. Please refer to the product instructions regarding accessories and extra equipment. The instructions must be fully observed to ensure personal safety and to protect the equipment and ensure its correct operation. EXHAUSTO A/S accepts no liability for accidents caused by equipment not used in accordance with the manual s instructions and recommendations. Supply air/extract air Left/Right Front page: Accessories NB These instructions use the following terms as given in DS447-2013: Supply air (air blown in) Extract air (air removed) Outdoor air Exhaust air The term R for Right, indicates the supply air is to the right of the cooling unit, as seen from the operating side. The term L for Left, indicates the supply air is to the left. The front page of the instruction manual contains a checklist, detailing the accessories delivered with the VEX unit. When retrofitting EXHAUSTO accessories, please update the checklist on the front page. Warnings: Opening the unit Do not open the service doors before the supply voltage has been disconnected at the isolation switch and the fans have stopped. The isolation switch is positioned on the left side of the connection box on top of the unit. 3/32

3003433-2014-04-11 Prohibited The VEX unit is not to be used to transport solid particles or in areas where there is a risk of explosive gases. No duct connection If one or more of the spigots is not connected to a duct: Fit a protective net to the spigots with a maximum mesh width of 20 mm (in accordance with EN294). Lock the air handling unit during operation The VEX unit must always be locked during operation: Use the cylinder lock in the handle. Remember to remove the key from the lock. Or use a padlock. Use the handle s built-in padlock fixture Information plate The VEX unit information plate shows: VEX model type (1) Unit production no. (2) NB: Have the production number ready at all times when contacting EXHAUSTO A/S. 4/32

3003433-2014-04-11 Product information 1. Product information 1.1 Model overview Model overview Positioning of fan, motor (M) and frequency converter (FC) Fan placement 1 (V1) M1 FC1 M2 FC2 RD12178-01 Fan placement 2 (V2) M2 FC2 M1 FC1 RD12179-01 Elements Fan Description RD12763-01 RD12767-01 Compact filter Bag filter RD12762-01 1,1,A or B Extract air spigot 1,2,A or B Exhaust air spigot 2,1,A or B Outdoor air spigot 2,2,A or B Supply air spigot 1 1 Air direction, extract air 2 2 Air direction, supply air 5/32

3003433-2014-04-11 Product information Fan placement and airflows Optional spigot positioning in relation to fan placement and filter type Compact filters Bag filters RD12763-01 RD12762-01 Fan placement 1, Right 1 2 RD12178-01 RD12979-01 RD12980-01 Fan placement 1, Left 2 1 RD12981-01 RD12178-01 RD12982-01 Fan placement 2, Right 2 1 RD12179-01 RD12983-01 RD12984-01 Fan placement 2, Left 1 2 RD12985-01 RD12179-01 RD12986-01 6/32

3003433-2014-04-11 Product information 1.2 Terms used in these instructions The simplified diagram shows a VEX unit with LEFT fan placement. Component Function BT40/BT50 1) Fire thermostat, 40 C/50 C (extract air) BT70 1) Fire thermostat 70 C (supply air) FC1 Frequency converter 1 FC2 Frequency converter 2 HMI 1) Control panel LS 1) Closing damper, outdoor/exhaust air M1 Fan motor, 1 M2 Fan motor, 2 MIO-CO 2 -DUCT 1) CO 2 sensor, duct MIO-CO 2 -ROOM 1) CO 2 sensor, room MIO-PIR 1) PIR sensor MIO-RH-ROOM 1) Humidity sensor MIO-TS-ROOM 1) Temperature sensor, room MIO-TS-DUCT 1) Temperature sensor, extract air (external) MPT1, P1 Airflow control, supply air MPT1, P2 Filter monitor, extract air MPT2, P1 Airflow control, extract air MPT2, P2 Filter monitor, outdoor air MPTDUCT Pressure transmitter, constant pressure regulation RHX2M Control unit for the rotary heat exchanger TE11 Temperature sensor, extract air TE12 Temperature sensor, exhaust air TE21 Temperature sensor, outdoor air TE22 Temperature sensor, supply air 7/32

3003433-2014-04-11 Product information TSA Component Overheating Function 1) Accessory. See checklist on the front page of these instructions. 1.3 Application Comfort ventilation EXHAUSTO VEX is used for comfort ventilation tasks. Operating temperature range for the unit see section "Technical data". Prohibited uses The VEX unit is not to be used to transport solid particles or in areas where there is a risk of explosive gases. 1.4 Location requirements Positioning The air handling unit is designed for indoor fitting. The air handling unit can be ordered for outdoor installation (accessory Outdoor, OD). 1.4.1 Spatial requirements The drawing below indicates how much space is needed for servicing, replacing filters, cleaning, etc. 1715 840 890 RD11538-01 NB: A free height of at least 200 mm is required above the unit s connection box. 8/32

3003433-2014-04-11 Product information 1.4.2 Requirements for underlying surface When fitting the unit directly to an existing surface - i.e. without using the mounting base (accessory) - the surface must be: flat level (+/- 3 mm per metre) hard resistant to vibration 1.4.3 Requirements for duct system Silencers Bends Insulation The duct system must be fitted with silencers specified by the Project Manager, which meet the requirements of the operating area. A duct bend may be fitted immediately after the unit, because the airflow in the spigot has a uniformly moderate speed profile, which results in negligible system pressure loss. The duct system must be insulated against: condensation sound leakage heating/cooling losses Condensation Condensation in the ducts may occur when the exhaust/outdoor air has high humidity. EXHAUSTO recommends a condensation outlet is also fitted at the lowest point in the ducts. No duct connection If one or more of the spigots is not connected to a duct: Fit a protective net to the spigots with a maximum mesh width of 20 mm. 9/32

3003433-2014-04-11 Product information 1.5 Description 1.5.1 The VEX unit design VEX200L - V1 The drawing below illustrates the construction of the unit (without service doors). 13 14 16 17 18 19 20 15 1 2 2,2,A 2,1,A 1,1,A 1,2,A 12 11 10 9 8 7 6 5 4 3 RD11694-01 VEX200L - V2 12 11 10 19 18 6 5 15 4 3 1,1,A 1,2,A 2,2,A 2,1,A 13 14 16 17 7 9 8 20 1 2 RD11695-01 10/32

3003433-2014-04-11 Product information VEX200R - V1 The drawing below illustrates the construction of the unit (without service doors). 3 4 5 6 18 19 10 15 11 12 1,2,A 1,1,A 2,1,A 2,2,A 2 1 20 9 8 7 17 16 14 13 RD11696-01 VEX200R - V2 2 1 20 19 18 17 16 15 14 13 2,1,A 2,2,A 1,2,A 1,1,A 3 4 5 6 7 9 8 10 11 12 RD11697-01 11/32

3003433-2014-04-11 Product information Pos. no. Part Function 1 Spigot, 2,1,A Outdoor air spigot. The spigot can also be positioned on the top or in the bottom of the unit (2,1,B) though only on units with compact filters 2 Closing damper (LS) Closing damper, outdoor air, LSF (accessory) 3 Closing damper (LS) Closing damper, exhaust air, LSA (accessory) 4 Spigot, 1,2,A Extract air spigot. The spigot can also be positioned on the top of the unit (1,2,B) 5 Fan unit For extract air/exhaust air 6 Exhaust fan frequency converter Variably adjusts fan 7 Rotary heat exchanger Conducts heat from extract air to supply air 8 Step motor Drives the rotary heat exchanger via the drive belt 9 Rotor control Controls and monitors the step motor 10 Extract air filter Filters extract air 11 Trim damper The trim damper (accessory) ensures there is pressure balance across the rotor and seals to prevent extract air from entering the supply air. Used with blowout zone (accessory) 12 Spigot, 1,1,A Extract air spigot The spigot can also be positioned in the bottom of the unit (1,1,B) though only on units with compact filters 13 Heating coil Heats supply air if heat recovery is insufficient (accessory) 14 Spigot, 2,2,A Supply air spigot The spigot can also be positioned in the top of the unit (2,2,B) 15 HMI panel Operation of the control system 16 Fan unit For outdoor air/supply air 17 Supply air fan frequency converter Variably adjusts fan 18 Connection box Connection box for supply voltage, external ventilation components, control panels and PC connection 19 Control system Positioning of control system components 20 Outdoor air filter Filters outdoor air Cabinet Ventilators Rotary heat exchanger Filters The inside and outside of the cabinet is made of Aluzinc and insulated with 50 mm mineral wool. The unit has a centrifugal fan for extract air and a centrifugal fan for supply air The rotary heat exchanger is driven by a step motor with rotor control, which controls the rotor's speed. There are built-in compact filters (as shown on the drawings on the previous pages) or bag filters on both the extract air and supply air side. 12/32

3003433-2014-04-11 Product information 1.6 Principal dimensions VEX250, V1 1600 610 381 62 350 300 62 M N 62 300 350 62 M N 940 1112 62 370 O 400 890 105 O 400 470 275 819,5 O 400 O 400 304,6 849 12 470 62 370 12 RD11539-01 NB The drawing shows all of the spigot positioning options. Spigot positioning marked with * is not available for VEX units with a bag filter. 13/32

3003433-2014-04-11 Product information VEX250, V2 1600 610 381 62 300 350 62 M N 62 350 300 62 M N 940 1112 62 470 890 O 400 105 O 400 370 304,5 849 O 400 O 400 275 819,5 12 370 62 470 12 RD11540-01 NB The drawing shows all of the spigot positioning options. Spigot positioning marked with * is not available for VEX units with a bag filter. 14/32

3003433-2014-04-11 Handling 2. Handling 2.1 Unpacking Supplied components Packaging The following components are supplied: VEX unit Supplied with accessories (as indicated in the checklist on the front page of the instructions) The unit is delivered attached to a disposable pallet and packed in clear plastic. NB The unit should be cleaned before it is used. Once the plastic has been removed, the unit must be protected against dirt and dust: The covers on the spigots must not be removed until the spigots are connected to the ventilation ducts. Whenever possible, keep the unit closed during fitting. Once the VEX unit is fitted, it must be checked and thoroughly cleaned. All dust, debris and metal shavings must be vacuumed up. 2.2 Transport Transport equipment Transport the VEX unit in one of the following ways: Method Manual transport: Lifting brackets for manual lifting can be fitted as shown in the drawing: Drawing RD10541-01 RD10542-01 15/32

3003433-2014-04-11 Handling Method Using lifting truck or fork-lift truck: Lift the VEX unit on the disposable pallet. IMPORTANT: If the disposable pallet cannot be used, the forks on the lifting equipment must be long enough to prevent damage to the bottom of the unit. Crane: Never lift the VEX unit by the lifting brackets with a crane. Use straps and lifting yokes to prevent damage to the unit. Drawing RD12463-01 RD13029-01 2.2.1 Weight The unit weighs 273 kg 2.2.2 Passage through openings Height Width The unit's height is 1,217 mm The list (below) shows how wide an opening has to be for the unit to pass through: If the opening width is* Less than 900 mm Between 900 and 948 mm Greater than 948 mm Response the unit will not pass through remove doors, see relevant section the unit can pass through 16/32

3003433-2014-04-11 Handling * Measurements are based on the exact dimensions of the VEX unit. 2.2.3 Internal transport with reduced weight Weight reduction Removing the service doors The weight can be reduced during transport by removing the service doors and fan units. To remove the service doors: A Detail A RD12580-01 A Open both doors Tap the hinge door pin out using a small pin bolt or similar Lift the doors off 17/32

3003433-2014-04-11 Handling To remove the fan unit RD11568-01 Step Action 1 Remove the fixing screws on the sliding rails (out towards the operating side) 2 Loosen the bindings on the motor cable and the measuring hose 3 Pull the fan unit out to the end-stop (a screw on each rail acts as a stop) 4 Remove the supply cable and modbus cable in the frequency converter box 5 Remove the measuring hose which is fixed to the intake 6 Remove the two end-stop screws (one on each rail). The fan unit can now be lifted NB: A single fan unit weighs 24 kg 18/32

3003433-2014-04-11 Mechanical assembly 3. Mechanical assembly 3.1 Installing the unit Description The VEX unit is installed so that it is horizontal. 3.1.1 Installed directly onto the floor NB The requirements for the floor surface must be met, see the section entitled "Requirements for underlying surface", chapter 1. After installation, check the VEX unit is completely level. 3.1.2 Installing on mounting base Diagram showing levelling screw positions The EXHAUSTO mounting base enables the air handling unit to be installed correctly. The base is equipped with adjustable levelling screws, so that the air handling unit can be fitted horizontally on a surface that is not level ( +/- 20 mm per metre). See diagram no. 3002646 for installing on the mounting base. 1598 1548 RD12469-01 890,8 840,8 19/32

3003433-2014-04-11 Electrical installation 4. Electrical installation 4.1 Electrical installation See the attached instructions Electrical Installation Guide of VEX240/250 with EXact control system : 20/32

3003433-2014-04-11 Maintenance 5. Maintenance 5.1 Operating readings via the HMI panel HMI panel Refer to the EXact Control System Basic Instructions for the VEX200 series for instructions on accessing Menu 2 Operating readings via the technician menu (access code 1111) to check the unit s operating status. 5.2 Maintenance chart Recommended intervals The following chart details the recommended maintenance intervals, under normal operating conditions. EXHAUSTO recommends maintenance is adjusted to suit the actual operating requirements. Filters* Component Procedure Once a year Replace when the display shows the filter alarm We recommend that both filters are replaced at the same time NB:The control system will give an early warning when a filter is becoming soiled, so that there is time to order a new filter or call a service technician Twice a year Filters should be replaced at least: Filter equipment Check that all the seals are tight X Seals and sealing strips Check that all the seals are tight X Fans and heating coil (accessories) Rotary heat exchanger Safety functions check Check Remove the fan unit. See section "Internal transport with reduced weight" Cleaning. See next section Check Cleaning when required. See next section Fire thermostats Temperature sensors on heating pipe (accessories) Closing damper Function check X Motor valve and circulation pump (accessories) Function check X X X X X *Filters Only use original filters The provided filter data and pressure loss graphs (section 7) are based on the use of original filters EUROVENT certification is only valid if original filters are used Use of non-original filters may cause leakage in the VEX and impair filter function EXHAUSTO recommends that you register the filter replacement date to ensure filters are replaced at the correct intervals 21/32

3003433-2014-04-11 Maintenance 5.3 Service 5.3.1 Filter replacement Use original filters Only use original filters. See section "Maintenance chart". How to replace filters Filter data Disconnect power at the isolation switch before opening the door. Pull the filters out. Remember to check the flow direction - see the arrows on the filter. Redundant filters must be stored immediately in sealed plastic bags and disposed of responsibly. After filter replacement: Update the new filter data in the EXact control system. See "EXact Basic Instructions for the VEX200 series". 5.3.2 Servicing and cleaning Cleaning motor/fan See section "Internal transport with reduced weight" for details on how to remove the fan units. Step Action 1 Switch off the power supply to the unit at the isolation switch before opening the doors 2 Clean the fan impellers with a vacuum cleaner and wipe down with a damp cloth if necessary 3 Clean the impeller blades carefully, so as not to disturb the balance 4 Once re-fitted, check the unit operates without vibrating Inspection of measuring points hoses 5 Remove the hoses at the connection box 6 Blow air through the hoses to remove any impurities Cleaning cold water coil/heating coil Step Action 1 Switch off the power supply to the unit at the isolation switch 2 Vacuum clean the cold water coil/heating coil 3 Cold water coil: clean the condensation tray 4 Check the fins on the exchanger are not deformed The fins are sharp 22/32

3003433-2014-04-11 Maintenance Cleaning rotary exchanger Step Action 1 Switch off the power supply to the unit at the isolation switch before opening the doors 2 Vacuum clean the exchanger with caution, ideally using a soft brush vacuum nozzle Avoid touching the fins in the exchanger with sharp or hard objects the fins are very soft and can easily be deformed, which will diminish the performance of the VEX 3 Check the fins on the exchanger are not deformed The fins are sharp 23/32

3003433-2014-04-11 Technical data 6. Technical data 6.1 Weight, corrosion class, temperature range, etc. Weights Doors Fan section Unit without doors and fan section (for internal transport) The total weight of the unit 2 x 15 kg 2 x 24 kg 195 kg 273 kg Corrosion class Corrosion class Corrosion class C4 in accordance with EN ISO 12944-2 Temperature range Outdoor air temperature Though supply air only Ambient temperature -20ºC to +35 C +10ºC to +35ºC -30ºC to +50ºC HMI panel Ingress protection Ambient temperature IP20 0 C - +50 C Fire thermostats Cut-out temperature, BT70 70 C Cut-out temperature, BT50 50 C Cut-out temperature, BT40 40 C Max. ambient temperature, sensor 250 C Ambient temperature, thermostat housing 0 C - +80 C Sensor length 125 mm Ingress protection IP40 24/32

3003433-2014-04-11 Technical data Motor damper Motor damper type LS400-24 LSR400-24 Term LSA/LSF LSFR Motor type NM24-F AF-24 Rotation time 75 150 s open: 16 s closed: 150 s Ingress protection IP42 IP42 Ambient temperature -20ºC to +50ºC -30ºC to +50ºC Damper depth (LS rail system) 100 mm 100 mm There may be a maximum of two LSR dampers or four LS dampers. 25/32

3003433-2014-04-11 Technical data 6.2 Compact filters Pressure loss graph for M5 and F7 filters 120 100 RD13033GB-02 F7 Pressure loss [Pa] 80 60 40 M5 20 0 0 500 1000 1500 2000 2500 3000 3500 4000 Volum flow [m 3 /h] Filter data FP250M5 FP250F7 Panel filter h x w 520 x 835 mm 520 x 835 mm Panel filter thickness 96 mm 96 mm Filter area 5 m² 15.7 m² Filter class M5 F7 Retention degree according to EN779 96% > 99% Efficiency 45% 85% Volume flow rate 3,200 m³/h 3,200 m³/h Initial pressure drop 43 Pa 79 Pa Recommended final pressure drop at normal volume flow rate 143 Pa 179 Pa Temperature resistant to 70 C 70 C EUROVENT certification is only valid if original filters are used. See under section 5 Maintenance, for more details about original filters. 26/32

3003433-2014-04-11 Technical data 6.3 Bag filters Pressure loss graph for M5 and F7 filters 140 120 RD13034GB-02 F7 100 Pressure loss [Pa] 80 60 40 M5 20 0 0 1000 2000 3000 4000 Volume flow [m 3 /h] Filter data FB250M5 FB250F7 Filter area 4.84 m² 5.96 m² Face area (h x w) 490 x 835 mm 490 x 835 mm Total number of bags x depth 13 x 380 mm 16 x 380 mm Filter class M5 F7 Retention degree according to EN779 96% > 99% Efficiency 45% 85% Volume flow rate 3,200 m³/h 3,200 m³/h Initial pressure drop 59 Pa 104 Pa Recommended final pressure drop at normal volume flow rate 159 Pa 200 Pa Temperature resistant to 70 C 70 C EUROVENT certification is only valid if original filters are used. See under section 5 Maintenance, for more details about original filters. 27/32

3003433-2014-04-11 Technical data 6.4 Capacity diagram 6.4.1 Unit with compact filter Capacity diagram with M5 filters SFP-curve (J/m 3) Operating curves A: Pressure loss addition with F7 filters B: Pressure loss addition via external heating coil 28/32

3003433-2014-04-11 Technical data 6.4.2 Unit with bag filter Capacity diagram with M5 filters SFP-curve (J/m 3) Operating curves A: Pressure loss addition with F7 filters B: Pressure loss addition via external heating coil 6.5 Ordering spare parts Find production number Contact To be able to supply the correct spare part for the specific VEX unit, the production number must be given when ordering the spare part. The production part number is written on the front page of the instructions supplied with the unit. It is also included on the information plate. Contact your local EXHAUSTO office service department to order a spare part. The telephone number is shown on the back cover of these instructions. If required, see chapter 1, section "The VEX unit's design" for an overview of terms and of the positions of parts. 29/32

3003433-2014-04-11 Technical data 6.6 EC Declaration of Conformity See document no. 3003646, Declaration of Conformity. The document is found in the door of the VEX unit. It is also available on the EXHAUSTO website (search using document no.) 30/32

3003433-2014-04-11 31/32