DSR-12/20 DSRT-20 DEHUMIDIFIER. GB General information - Exploded view - Parts list

Similar documents
Dehumidifier- DSR Instruction manual version 01

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

HIGH WALL AIR CONDITIONER

DSR-12/20 DSRT-20 GENERAL INFORMATION EXPLODED VIEWS - PARTS LISTS ENGLISH

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

Mobile Air Conditioner Instruction Manual Model TC-N9KM

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

Portable Air Conditioner USER MANUAL

Air Conditioner Service Manual

51AKB / 51 AKC OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

DESICCANT DEHUMIDIFIER

30KW ELECTRIC FAN HEATER

DEVIL CERAMIC SPACE HEATERS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

Xpelair Simply Silent TM Contour Fan

Chest Freezer Instruction manual

15KW ELECTRIC FAN HEATER

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

Simply Silent Contour 4 (100mm) Axial Extraction Fan

PORTABLE AIR CONDITIONER MODEL NO: AC7000

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Service Manual & Installation Manual

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Built-in Gas Hob CZ55554 CZ55571

ER MANUAL FOR YOUR BAUMATIC

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

identity installation & maintenance instructions customer/technical services guarantee

CMS1402 SERVICE PARTS

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

VIKING RANGE CORPORATION, P.0. DRAWER 956, GREENWOOD, MS. USA

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Xpelair Simply Silent DX150

Xpelair Simply Silent TM DX100 Fan

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

2. Mobile Air-conditioner (KY-32)

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Service Manual & Installation Manual

SH3020 USER INSTRUCTIONS

CDP 40 SWIMMING POOL DEHUMIDIFIER

Cabinet Refrigerators/Freezers Instruction manual

DEHUMIDIFIERS & VENTILATORS

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Air Conditioner Service Manual

- 1 - Updated on 18 March, 2010

12,000 BTU Evaporative Portable Air Conditioner

PANTHER. Condensate removal pump Installation and operating guide

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

Meaco 10L small home dehumidifier Instructional Manual

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

- 1 - Updated on 18 March, 2010

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

CU1526, CU2026, CU3030 Service Parts

Instructions manual DEHUMID HP50

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PGD930DES USER MANUAL. VER

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

13500 BTU RV Air Conditioner Installation and Operating Instructions

Easy Glide 1800w steam iron

Manual / Handbuch Spare parts list / Ersatzteilliste

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Xpelair Simply Silent DX100

CDC266 Reverse Action

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

MeacoDry ABC Range Dehumidifiers

Trento. Modular Suite. For use with the Skope Electric Outset Range. Instructions for Use and Installation

Operating Instructions Wine storage refrigerator 12/

DUST EXTRACTOR MODEL No: CDE1000

CME650 SERVICE PARTS

Stainless Steel Counter Refrigerators Instruction manual

TABLE OF CONTENTS FOR YOUR SAFETY

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Desiccant Dehumidifier

ELECTROLUX ELECTRONICALLY CONTROLLED A SERIES COMPACT SIDE BY SIDE REFRIGERATOR

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Quest Dry 105, 155, and 205 Dual

SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor.

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Ultraglide 2200w steam iron

For more Parts Information:

Transcription:

DSR-12/20 DSRT-20 DEHUMIDIFIER GB General information - Exploded view - Parts list

SAFETY For safety reasons, read this information carefully before operating. Persons who are not familiar with this type of product must not use it. We strongly recommend keeping this information in a safe place for future reference. This appliance must be earthed. The unit is designated for indoor operation. Refer to the rating plate for voltage and power input. The installation must be in accordance with regulations of the country where the installation is performed. The minimum distance between air inlet(s) and/or air outlet(s) and any object must be 40 cm. * The unit is safe. However, as with other electrical appliance, use it with care. * Keep out of reach of children. * Do not clean the unit by spraying it or immersing it in water. * Do not insert any object into an opening of the unit. * Disconnect from the mains before cleaning the unit or any of its components. * Never connect to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licensed electrician. * Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. * When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform the regulations regarding electrical installations. Do not use your dehumidifier under the following conditions: If the power cable wires are frayed or cut Where the power cable may be damaged If an extension cord is needed to reach an outlet Close to a heat source This product is not made for DIY repair When small children may be left unattended If there is a risk of liquid falling on the unit Where it may be damaged by chemicals Where there is a risk of interference by foreign objects Reminder: Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. 2

ELECTRICAL WIRING The unit can be supplied with a cord and an earthed plug. If it ever becomes necessary to replace this plug, be sure to use an earthed plug suitable for the power supply in your area and conform your national safety standard. The wires of the cable are coloured in accordance with the standard electrical code. BLUE BROWN GREEN/YELLOW NEUTRAL LIVE EARTH The BLUE (NEUTRAL) wire should be connected to the terminal in the plug marked N or coloured black. The BROWN (LIVE) wire should be connected to the terminal in the plug marked L or coloured red. The GREEN/YELLOW (EARTH) wire should be connected to the terminal in the plug marked E or coloured green or marked with this symbol : The unit must be connected to the power supply with the appropriate leads. The cord should pass through holes with rubber grommets. Properly fused disconnect switches must be installed between the unit and the power source. The unit must be wired with an isolation (mains) switch accessible from outside the wet area in which the unit is installed, to comply with IEE regulations. Attention! 3 minutes delay on all units with Alfa-14 controller. When starting or restarting the unit, it will take 3 minutes before the compressor and the fan will start running. 3

AMCOR DEHUMIDIFIERS You can t control humidity and haze outdoors. But in an indoor swimming pool and other humid interior spaces where hot stuffy air, steamy windows and walls are frequent phenomena, you can. That s why you need Amcor. Amcor s dehumidifiers clear the air in damp interior spaces. Condensation is removed from windows, walls and ceilings. Vaporous stuffy air is drawn off, clean air is pumped back in. You simply set the dial and the air humidity remains at the required level. And, the Amcor dehumidifier is an energy saver. Water evaporating from a swimming pool, bathroom, archive, store or from wet objects and surfaces increases the humidity of the air and creates the hazy and stuffy air often found in the hall. At the same time water condenses on the cooler parts in the hall: windows, walls, ceilings, etc. Water condensation is not only an aesthetic defect, it can, in the long run, cause structural damage. There are two methods for drying the air in humid spaces: - by ventilation, - by heat pumps. The Amcor dehumidifier is designed as a heat pump and has, through energy saving, a considerable advantage over a ventilation system. HOW THE AMCOR DEHUMIDIFIER WORKS The fan (1) sucks the humid air through the evaporator (2). There the air is cooled and the moisture in the air condenses into water. This water is collected in the tray (3) and drained away through the sump and piping. The compressor (5) pumps the heat, which has been extracted from the air, into the condenser (6). There, this heat is once again released, and absorbed by the dry air. The ready wired control box monitors and controls the operation. 2 3 4 1 5 6 4

INDOOR SWIMMING POOL DEHUMIDIFIERS The Amcor pool dehumidifier is a ready to install, transportable, appliance. It can be mounted on a wall or ceiling console in the pool room or even over a shower booth. It may be mounted in adjoining rooms and connected by ducts to the pool room. Amcor has not adapted normal room air-conditioners for use in indoor swimming pools, but has developed pool dehumidifiers particularly Model DSR for this purpose. The compressor therefore matches exactly the capacity of the evaporator, thus achieving the optimal balance between efficiency and power consumption. The pool dehumidifier is controlled by a humidistat which operates at a low (=safety) voltage of 24 V. The relative humidity in an indoor swimming pool can be adjusted between 50 80 % when an external hygrostat is used. 5

INSTALLING MODEL DSR/DSRT The minimum distance between inlet(s) and/or outlet(s) and any object must be 40 cm. Installation of the dehumidifier is easy, as the unit is built on a base and slides out of the housing. The individual parts are logically arranged and can be inspected. First, remove the screws of the frame with louvres. Remove the screws on the base. Now the unit can be taken out the housing. Prepare a suitable console and mount it on the wall. Mount the housing on the console and attach it by fastening its base with screws to the legs (which should preferably be lagged with a vibration dampening material). Insert the unit into the housing, fasten the housing to the base and attach the louvred frame in front of the housing. Attach a 3/4 I.D. flexible pipe to the drain nipple located at the back of the dehumidifier. 6

MAINTENANCE The appliance is actually maintenance free, except in cases of soiling. In this case the filter has to be cleaned. To take the filter out, unscrew 2 screws fastening the filter grid, located at the back. Swing the grid towards you and up in order to get access to the filter. Remove the filter. Hold it under a water tap and flush it clean with a stream of water. Let the trapped water drip off the filter fabric and replace the dried filter in reverse order. OPERATING RANGE DSR-12/20 Min. working temperature 5 C, max. working temperature 35 C. Relative humidity 40 100 %. 7

EXPLODED VIEW 6 22 8 14 7 2 13 3 4 1 5 15 36 31 30 39 33 40 29 35 12 32 11 17 18 23 10 19 20 21 24 25 26 27 28 38 16 PART NO. QTY. PART NAME NO. A436844 1 CASING 1 468038 1 GRID 2 A436536 1 AIR-FILTER 3 A436334 1 FRAME 4 A434632 1 EVAPORATOR DSR-12 5 A434642 1 EVAPORATOR DSR-20 A414305 1 TOP COVER 6 A342695 1 WALL RIGHT 7 A528644 1 LOUVRES (IN) 8 508002 2 CLAMP 9 8

PART NO. QTY. PART NAME NO. 68038 1 LOUVRES (OUT) 10 A436324 1 FRONT 11 A434664 1 COVER CONTROL BOARD 12 A492474 1 CONTROL BOARD 13 A342705 1 WALL LEFT 14 A434276 1 CAPILLARY DSR-12 15 A434576 1 CAPILLARY DSR-20 A326504 1 CHASSIS 16 292026 1 STRAINER DISTRIBUTOR 17 A342725 1 LEFT BULKHEAD 18 X1002110542 1 EVAPORATOR DSR-12 19 X1003140542 1 EVAPORATOR DSR-20 X1003190562 1 CONDENSER DSR-12 20 X1004190562 1 CONDENSER DSR-20 274312 1 COMPRESSOR DSR-12 21 274314 1 COMPRESSOR DSR-20-1 PH 271317 1 COMPRESSOR DSR-20 3 PH 271283 1 FAN MOTOR+HOUSING DSR-12 22 271284 1 FAN MOTOR+HOUSING DSR-20 A328675 1 DRAIN PAN 23 DEPEND OF COMP. RUBBER GROMMET 24 DEPEND OF COMP. SLEEVE 25 O81071 WASHER 26 O81075 SPRING WASHER 27 OO4025 NUT 28 295060 1 LEVER SWITCH 29 294012 6 GROMMET 30 294010 4 GROMMET 31 DEPEND OF COMP. CAPACITOR - COMPRESSOR 32 275031-34 TERMINAL 33 429171 CONTACTOR DSR-3PH 34 482301 1 TRANSFORMER 35 386117 1 DEFROST CONTROL 36 346518 SEAL FOAM STRIP 37 508027 2 LINE CORD CLIP 38 326101 1 FUSE 1A 39 275016 1 TERMINAL FUSE 40 9

MOISTURE REMOVAL DSR-12 Moisture removal (L/24h) at different room temperatures and different relative humidity levels RH % 85 80 75 70 65 60 55 50 Temp C 15 41 37 34 31 28 25 23 17 20 57 52 48 43 38 34 30 27 24 73 66 60 55 49 43 39 34 25 77 70 6 58 81 46 41 36 26 80 73 67 60 54 48 43 38 27 84 77 70 63 56 50 45 40 28 88 80 73 66 59 52 47 42 29 92 84 76 69 62 55 49 43 30 96 87 79 72 64 57 51 45 32 100 91 82 75 67 59 53 47 35 104 94 86 78 69 62 55 49 DSR-20/DSRT-20 Moisture removal (L/24h) at different room temperatures and different relative humidity levels RH % 85 80 75 70 65 60 55 50 Temp C 15 69 62 57 52 46 41 23 17 20 96 87 79 72 64 57 51 45 24 121 110 100 91 81 72 64 57 25 128 116 106 96 85 76 68 60 26 134 122 111 101 90 80 71 63 27 141 128 116 106 94 84 74 66 28 147 134 121 110 98 87 78 69 29 153 139 127 115 103 91 81 72 30 160 145 132 120 107 95 85 75 32 166 151 137 125 111 99 8 78 35 173 157 146 130 116 103 92 82 10

WIRING DIAGRAMS DSR-12 11

DSR-20 12

DSRT-20 TECHNICAL DATA Model 12 DSR 20 DSR 20 DSRT ELECTRICAL SUPPLY V 230 230 380 (3 phase) FREQUENCY Hz 50 50 50 MOISTURE REMOVAL AT 30 C AND 65 75 % R.H. L/h 2.7 3.6 4.5 5.6 4.5 5.6 POWER CONSUMPTION W 1300 2600 2600 CURRENT A 6.0 12.0 3 x 4 REFRIGERANT R407C R407C R407C REFRIGERANT CHARGE g 1300 1650 1650 AIR DELIVERY MAX. m 3 /h 1300 1500 1500 FAN SPEED 2 2 2 SWIMMING POOL SURFACE m 2 35 50 50 NET WEIGHT kg 68 78 78 LENGTH WIDTH HEIGHT mm 680 665 452 680 665 453 680 665 453 13

Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Jersey 07072, United States of America Tel: +1 201 460 8100 Fax: +1 201 460 9481 Email: amcorusa@amcorgroup.com The Netherlands Amcor B.V. Anton Philipsweg 9-11, 1422 AL Uithoorn, The Netherlands Tel: +31 297 560 079 Fax: +31 297 523 062 Email: amcorex@amcorgroup.com Israel Amcor International Ltd 1 Sapir St., P.O. Box 12001, Hertzelia Pituach, Israel Tel: +972 9 951 5351 Fax: +972 9 958 5650 Email: amcoril@amcorgroup.com Singapore Amcor Investments (Singapore) Pte Ltd 545 Orchard Road, #13-02, Far East Shopping Centre, Singapore 238882 Tel: +65 6297 9881 Fax: +65 6297 8891 Email: amcorsg@amcorgroup.com China Shan Xia Industrial Development Zone, Heng Li Town, Dongguan City, Guangdong Province, China Plant One - Amcor (China) Ltd Tel: +86 769 8372 1090 Fax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant Two - Amcor Appliances Ltd Tel: +86 769 8372 1970 Fax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com