LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

Similar documents
ROBUST Electric fan heaters for demanding environments

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

RAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES

DEHUMIDIFIERS & VENTILATORS

Applications Damage service Building drying Water works Dry storing FEATURES

CDP 40 SWIMMING POOL DEHUMIDIFIER

USER AND MAINTENANCE MANUAL

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

MOBILE DEHUMIDIFIERS. Dehumidifier with adsorption rotor. Mobile dehumidifiers. Quality with systems

Humidity is simply the amount of water vapour that is present in the air. The recommended humidity level for dwellings is per cent.

CAW Ceiling-mounted fan heaters for hot water

Condensation drying for industry and trade

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

VFL, VFLPG, VTL and VRA Rectangular electric duct heaters

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Meaco 10L small home dehumidifier Instructional Manual

PGDX Rectangular duct coolers with DX coil

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

PRODUCT CATALOGUE MOBILE. Heating, drying, cooling, ventilation

HEATERS DEHUMIDIFIERS COOLERS 2016/2017

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

DOMESTIC DEHUMIDIFIERS FLIPPERDRY

USE AND MAINTENANCE MANUAL

Superdryer Dehumidifiers

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

COTES ALL-ROUND THE C30 RANGE

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Registrate by scanning

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

High temperature air-to-water heat pumps

Instructions manual DEHUMID HP50

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

OPERATING INSTRUCTIONS

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

CV Circular electric duct heaters

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Meaco 20L medium home dehumidifier Instruction Manual

PDA20DX Air Purifying Dehumdifier Manual

Fan speed controller Type Saginomiya XGE

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

P8,990. CS Raffles Tech Inc Singalong Street, Paco, Manila , ,

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

51AKB / 51 AKC OWNER S MANUAL

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

MeacoDry ABC Range Dehumidifiers

51AKS I S O OWNER S MANUAL

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Technical Datasheets. Always By Your Side.

Instruction manuel design dehumidify 60 liter

CV Circular electric duct heaters

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

Colt CoolStream Adiabatic Cooling & Ventilation System

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Technical data LA 60TUR+

Pool dehumidification for comfort and wellness

OPERATION MANUAL. 20ltr Black - DS31837 (BCH-20B) 24ltr Black - DS28917 (BCH-24B) 24ltr White - DS31838 (BCH-24W) 32ltr Black - DS28918 (BCH-32B)

Honeywell Portable Air Conditioners. A compact, easy to use portable cooling solution.

PRODUCT OVERVIEW. Dehumidifiers

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Thermal management for your cabinets!

AlorAir Solutions INC Add: Shoemaker Ave,Cerritos,CA90703 Tel:

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Dehumidifiers Catalogue

20L/D DEHUMIDIFIER Model Number: IG9800

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

Technical data LA 9S-TU

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

ODE20: 20 LITRE DEHUIMIDIFIER

installation & operating instructions

Energy Saving Measures for Automotive Air Conditioning (AC) System in the Tropics

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

REMKO ETF 240 Portable Air Dehumidifier

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

Fan heater SWT Ceiling mounted fan heater with water heat

Model DH-10 Dehumidifier

Operation manual. Dehumidifier CFO-20N

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Dehumidifiers SW22FW SW22FM SW38FW SW38FM SW42FW SW42FM SW38FX Silent SW42 FX Silent SW59FX Silent

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Transcription:

LAF Dehumidifiers

LAF D e h u m i d i f i e r s LAF 50 / 100 / 150 Condensing dehumidifiers for professional use VEAB condensing dehumidifiers are designed for professional use in application in which strict demands are made on capacity. The LAF is therefore suitable for building sites and for dealing with water damage in order to achieve a sufficiently low humidity of the building materials, carpets and wall covering materials. In basements and warehouses, the LAF can maintain sufficiently low humidity to avoid corrosion, smells and mould problems. Drying by means of a LAF dehumidifier is very economical and efficient. The energy consumption is minimal compared to warming and then ventilating away the humid air. For every litre of water evaporated, 700 W of heat are recovered. Demand-controlled hot gas defrosting Easy to handle - large wheels ensure good mobility Robust, durable design suitable for building sites - can be lifted by the handle Energy-efficient rotary compressor - saves about 30 % of energy compared to a piston compressor Efficient tubular evaporator that dehumidifies even when the temperature is low and when the humidity is low Service temperature range 3-30 C Humidity operating range 25-100 % RH Automatic stop when the condensate container is full Accessories Wall bracket Operating hour meter Condensate collecting container with built-in pump Hygrostat (humidistat) Design Built-in condensate collecting container with level switch and provision for connecting a drain hose. 2-metre long 230V power supply cable with plug. Electronic demand-controlled hot gas defrosting offers quick and effective defrosting. Approvals The dehumidifiers have been tested and approved by SEMKO in accordance with: LVD Directive: EN 60355-1, EN 60335-2-40 and EN 50366 EMC Directive: EN 61000-6-1 and EN61000-6-3 EMF Directive: EN 50366 Degree of protection IP X4. Page Chap. 15

D e h u m i d i f i e r s Types/Models LAF 50, LAF 100 and LAF 150 Basic models without electric heating. Capacity of LAF 50 Temp., C LAF 50E, LAF 100E and LAF 150E Models with suffix E have built-in 1500 W heater elements. Switch for selecting dehumidification with or without electric heating. A permanently preset room thermostat controls the electric heating at around 22 C. LAF 50E2 The LAF 50E2 has a built-in 2000 W electric heater element. Switch for selecting dehumidification with or without electric heating. A permanently preset room thermostat controls the electric heating at around 22 C. Capacity of LAF 100 Temp., C Capacity, litres/24 h When selecting a dehumidifier, it is important to compare the capacity at a normal operating point. A normal operating point for dehumidification is 20 C and 60% RH. (The capacity at 30 C and 80% RH is of no interest in normal use.) Capacity, litres/24 h Capacity of LAF 150 Temp., C Capacity, litres/24 h LAF Chap. 15 Page

LAF D e h u m i d i f i e r s Technical data LAF 50 LAF 50E LAF 50E2 Operating humidity range, % RH 25-100% 25-100% 25-100% Operating temp. range, C +3 - +30 +3 - +30 +3 - +30 Max. power consumption, W 550 2050 2550 Power consumption W at 20 C / 60% RH 400 400* 400* Heater element, W - 1500 2000 Dehumidification at 20 C, 60% RH, l/24h 13 13 13 Dehumidification at 30 C, 80% RH, l/24h 22 22 22 Power consumption, kw/litre at 20 C, 60% RH 0,73 0,73* 0,73* Degree of protection IP X4 IP X4 IP X4 Refrigerant R 407C R 407C R 407C Rotary compressor yes yes yes Weight, kg 37 38 38 Dimensions L x W x H mm 400x500x890 400x500x890 400x500x890 Fuse, A 10 10 16 Air flow rate, m 3 /h 500 500 500 * Power consumption excluding heater element. Technical data LAF 100 LAF 100E LAF 150E2 LAF 150E Operating humidity range, % RH 25-100% 25-100% 25-100% 25-100% Operating temp. range, C +3 - +30 +3 - +30 +3 - +30 +3 - +30 Max. power consumption, W 1070 2570 1470 2970 Power consumption W at 20 C / 60% RH 720 720* 1070 1070* Heater element, W - 1500-1500 Dehumidification at 20 C, 60% RH, l/24h 25 25 36 36 Dehumidification at 30 C, 80% RH, l/24h 49 49 71 71 Power consumption, kw/litre at 20 C, 60% RH 0,69 0,69* 0,71 0,71* Degree of protection IP X4 IP X4 IP X4 IP X4 Refrigerant R 407C R 407C R 407C R 407C Rotary compressor yes yes yes ja Weight, kg 52 53 63 64 Dimensions L x W x H mm 390x600x1020 390x600x1020 390x600x1150 390x600x1150 Fuse, A 10 16 10 16 Air flow rate, m 3 /h 850 850 925 925 * Power consumption excluding heater element. Dehumidification tips Locate the dehumidifier to ensure the best possible air circulation in the room Keep the doors and windows closed A higher room temperature accelerates the dehumidification Untreated iron surfaces will not rust at ambient humidities below 50% RH No significant growth of mould occurs at ambient humidities below 65% Page 4 Chap. 15

D e h u m i d i f i e r s Accessories Hygrostat (humudistat) A hygrostat is available as an accessory for controlling the room humidity. The hygrostat is connected to the dehumidifier by means of a plug directly at the normal cable connection of the dehumidifier. Degree of protection IP 21. (Not for use on building sites). Operating hour meter The operating hour meter measures the compressor operating time. Can be factory-fitted to the humidifier or as an accessory for retrofitting. Condensate collecting container with pump The pump is fitted with a level switch that automatically starts and stops the pump. The collecting container has a socket to which the dehumidifier plug can be connected. Power supply: 230 V. Connection for Ø 6 mm i.d. hose. Max. pump delivery head: 7 metres Wall bracket For permanent installation of the dehumidifier. How the dehumidifier works The built-in fan continuously circulates the room air through the dehumidifier. When the humid air flows through the evaporator (cooling element), it will be cooled to its dew point and condensate will be precipitated out of the air. The water runs down into the condensate collecting container. The built-in level switch will stop the dehumidifier when the condensate container is full. The dry and cold air then flows through the condenser where it is heated by the compressor heat and by the energy recovered in the earlier conversion of water vapour into water. The dry and warm air is discharged back into the premises, where it absorbs more moisture. At certain temperature/humidity conditions, frost will form on the cooling element. Automatic defrosting control is then activated once an hour and delivers the warm gas to the cooling element so that the frost will be thawed and will run down into the condensate collecting container (hot gas defrosting). In order to speed up the drying process, models E and E2 of the LAF have built-in electric heaters that raise the temperature in the premises, thus accelerating the drying process. 5 1 1. Evaporator 2. Condenser 3. Rotary compressor 2 3 4 4. Fan 5. Condensate collecting container LAF Chap. 15 Page 5

LAF D e h u m i d i f i e r s LAF 10 Compact dehumidifier for smaller premises The LAF 10 is a dehumidifier that lowers the air humidity, while also supplying additional heat to the premises. The dehumidifier is suitable for maintaining a low humidity in basements, storage areas and the like. The LAF 10 is also excellent for drying laundry. The laundry will dry more quickly, and humid air will not spread through the house. Low energy consumption Adjustable hygrostat (humidistat) Low sound level Two fan speeds Built-in filter Automatic defrosting Outlet for drain hose Wheels and carrying handle make the unit easy to handle Technical data Air humidity operating range, % RH 30-80 Operating temperature range, C 8-35 Power consumption (at 20 C) W 220 Current (at 20 C) A 1,0 Power supply V 230 V AC Condensate container volume, l 4,0 Refrigerant type R134a Degree of protection IP 21 Weight, kg 13,5 Width, mm 270 Height, mm 550 Depth, mm 364 Capacity of LAF 10 litres/24h At 32 C 80 % RH, 10,0 At 27 C 60 % RH 5,0 At 20 C 60 % RH 4,0 At 8 C 60 % RH 1,8 Design Degree of protection IP 21. Built-in condensate collecting container with level switch and indicating lamp. Connected to the mains power supply by means of an earthed plug. Water hose connection: Ø 6 mm. Approvals The dehumidifier has been tested and approved by TÜF in accordance with: LVD Directive: EN 60355-1, EN 60335-2-40 and EN 50366 EMC Directive: EN 61000-3-2, EN 61000-3-3, EN 55014-1 and EN 55014-2 EMF Directive: EN 50366 Page 6 Chap. 15

D e h u m i d i f i e r s Control panel 1. Fan Pos. - low fan speed Pos. - high fan speed 2. Lamp lights up when the dehumidifier is running 3. Lamp lights up when the condensate 4. Humidistat knob container is full or has been left out. Hygrostat for presetting the required air humidity (30-80% relative humidity) 2 3 4 1 Plug the power supply cable into the wall socket, preset the required air humidity and fan speed, and then start the dehumidifier. The LAF 10 will now run to lower the air humidity to the preset level. When the condensate collecting container is full and needs to be emptied, an indicating lamp will light up and the dehumidifier will stop. Scope is available for connecting a hose to discharge the condensate directly to drain. How the dehumidifier works The LAF 10 operates along the same principle as a heat pump or a refrigerator. The humid room air is cooled as it flows through the cold evaporator. During the cooling process, the water vapour condenses out of the air to form water droplets. The condensate is collected into the built-in condensate collecting container, and so is the water from the automatic defrosting. This process in which the water gives up its heat to the air, together with compressor heat, causes the air discharged back into the room to be dehumidified and to have a temperature that is about 5-7 C higher than the incoming air. The electrical energy consumed by the dehumidifier and the energy liberated when the water condenses are thus returned in the form of warm air. LAF Chap. 15 Page 7

VEAB Heat Tech AB Phone: + 46 451 485 00 Fax: + 46 451 410 80 www.veab.com veab@veab.com