POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

Similar documents
TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

SENTRA Series Water Unit

Temptek Auxiliary Equipment

/ Aquatower Fiberglass Cooling Tower /

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

TM Series. Induced Draft, Counter Flow Optional Accessories

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Aquatower STEEL COOLING TOWER. engineering data and specifications

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Call us today! (800)

Energy-Saving Industrial Water Chillers

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CTI Sponsored Educational Program

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

TRIDENT GS SERIES Central Chiller

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Call us today! (800)

Call us today! (800)

LQ AQ SQ. Air-cooled and water-cooled portable chillers

SNOWCOOL SYSTEMS INDIA PVT LTD.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

JCseries EVAPORATIVE CONDENSER. engineering data

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

What is a Closed circuit Cooling Tower (CCT)?

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Paragon. Induced Draft, Counter Flow Optional Accessories

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Polaris PHEs vs. Shell-and-Tube Exchangers

MAC N-407 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller

OACS Outdoor Air-Cooled Central Chillers

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

SECTION ROTARY-SCREW WATER CHILLERS

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

HYBRID ADIABATIC Cooling System

Water-Cooled Dual Compressor Screw Chiller

DIVISION 15 MECHANICAL

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Installation Operation Maintenance

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Plenum Fans. Model HPA. Direct Drive

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

Central Chillers TS Series

MACH N-407 Heat Pump Air-Cooled Chiller

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

GIRTON CABINET WASHER MODEL 794A

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

VOLUME 2 (BOQ & Price Bid)

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

Air-Cooling Evaporators

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

SECTION COOLING TOWERS

NEW CHILLER SCHEDULE

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

PACKAGED AIR COOLED Product Data Catalog

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

GP SERIES Packaged Chillers

40 RM/RMS Packaged Air-Handling Units

High Capacity Instantaneous Steam Fired Water Heater

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

FCC Fan-Coil Units High-Performance, Vertical

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

2002 METAL FORM MFG. Form No: CCIOM/03

Installation Operation Maintenance

Mr. GoodTower Service Center

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

SECTION AIR COOLED WATER CHILLERS

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Forced Draft, Axial Fan Models Available in Capacities from 124 to 1,408 Ammonia Tons!

Technical Specifications & Pricing

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

VERTICAL FAN COIL UNITS

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Series 1500 Cooling Tower Specification

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Evaporative Cooling products

Transcription:

Temperature Control Units Water & Oil 0-500 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons Cooling Tower Cells 5-50 tons Filters Heat Exchangers TM POWER TOWER SERIES Fiberglass Construction 5 to 50 Tons Phone: 7-887-079 WARRANTY 5 Year: Covering fan and motor 0 Year: Covering the fiberglass shell 05 ton Power Tower cooling tower YOUR PROCESS DEMANDS THE MOST DEPENDABLE TOWER CELL AVAILABLE. Advantage Power Tower Series cooling towers won t let you down. Every Advantage tower cell is supported by application expertise, engineering know how, and un-surpassed service support from experienced technicians. Since 977 Advantage has been applying, designing and servicing the best chillers available. 5 ton Power Tower cooling tower APPLICATIS Power Tower Series cooling towers can be used on a variety of process applications that require 75 F to 85 F cooling water. Molds & Dies Nozzles, Barrels & Tools Heat Exchangers Troughs & Tanks Rolls Radiators and Air Coils Jacketed Vessels and Mixers Lasers

BUILT FOR THE INDUSTRIAL ENVIRMENT Power Tower cooling tower cells provide cooling water to industrial applications such as hydraulics, chiller condensers, temperature control units and other equipment requiring water for cooling. Advantage Engineering is the exclusive manufacturer of the Power Tower. Extensive testing and design has resulted in a compact, space efficient and highly versatile cooling tower. Power Tower cooling tower cells are available from 5-50 tons cooling capacity in single and expanded cell systems. Fan Motor With Stainless Steel Support Framework Air-Foil Shaped Glass Filled Polypropylene Fan Blades Drift Eliminator Stationary Water Distribution Header Inspection Cover Stacked Honey Comb Wet Deck Wet Deck shelf and flow diverter (not visible) Inlet Louvers Flooded Sump Outlet Structural Steel Base COUNTER AIR FLOW DESIGN... the Power Tower maintains full capacity and temperature control stability over a wide range of wind, air temperature and humidity extremes. Nominal rating conditions are cooling gallons per minute per ton of capacity from 95 F to 85 F at 78 F wet bulb. CSTRUCTI... with the exception of the structural steel base, the Power Tower is constructed entirely of non-ferrous materials. All wetted surfaces including the shell, wet deck, fan/motor frame work and header are either fiberglass, stainless steel or PVC. These materials are designed for constant water contact under hot/cold air temperature extremes. Fiberglass shells, up to / thick in structural areas assure mechanical integrity and long service life. WARRANTY AND SERVICE... the Power Tower comes with a 0 year warranty on the fiberglass shell and a 5 year warranty on the mechanical components. The Advantage Service Department is staffed with experienced technicians, and supported by a nationwide network of service personnel. With Advantage, service is only a phone call away. HOW IT WORKS... warm water returning from process is evenly distributed over the wet deck by the water distribution header and spray heads while the direct drive fan draws air from the inlet louvers, through the wet deck and out the top of the tower. The falling water and counter airflow causes a portion of the warm process water to evaporate. When the small portion of the warm process water evaporates the latent heat of evaporation cools the remaining water to the desired temperature. At design conditions about % of the water flow rate evaporates to achieve the cooling affect desired. WATER TEMPERATURE... the minimum water temperature that can be achieved by an evaporative cooling tower is dependent on the wet bulb temperature, which is a reporting of the current ambient temperature and humidity. Generally cooler and dryer air can result in cooler water. Advantage cooling towers can produce water between 5 & 0 F above the current wet bulb temperature which is often cooler then the outside ambient air temperature. Contact Advantage to determine your expected performance. The maximum recommended entering water temperature is 5 F. COMPENTS Phone: 7-887-079 HIGH PERFORMANCE INLET LOUVERS... are positioned to minimize splash out and direct incoming air at the proper angle for even distribution into the wet deck. Louvers prevent large air borne debris (such as leaves) from entering the system. Louvers are removable for cleaning. HIGH VOLUME FAN AND MOTOR ASSEMBLY... the only moving part and it s nearly maintenance free! A glass filled polypropylene is molded into air foil shaped fan blades. Fan blades are set at the factory to achieve optimum air flow. Totally Enclosed Fan Cooled (TEFC) motors are rated for outdoor and moist air extremes found in cooling tower applications. The fan/motor assembly is supported by a stainless steel framework which is attached to the fiberglass shell at reinforced locations with stainless steel fasteners.

TEMPERATURE PROCESS PUMP TOWER PUMP TOWER FAN TOWER FAN TO PROCESS FROM IN TOWER OUT POWER START STOP PROCESS OVERTEMP PROCESS PRESSURE ALARM ACTIVE TANK LEVEL OK MAKE-UP VALVE MADE IN AMERICA WATER INLET " SCHED 0 PVC TEMPERATURE PROCESS PUMP TOWER PUMP TOWER FAN TOWER FAN R TO PROCESS FROM IN TOWER OUT POWER START STOP PROCESS OVERTEMP PROCESS PRESSURE ALARM ACTIVE TANK LEVEL OK MAKE-UP VALVE R MADE IN AMERICA PLAN FOR FUTURE GROWTH Additional pumping capacity and electrical interfaces can be anticipated in the basic pump tank/tower cell design. By adding additional Power Tower cells, the system grows as your process cooling requirements grow. The future additions of tower cells also add flexibility of operation and back up redundancy for maintenance periods. Operating cost is reduced during off-peak low load periods since the tower cell fan motors are staged and consume only the electrical energy required for the present cooling requirement. Original System Expanded System CLOSED LOOP SYSTEMS REDUCE MAINTENANCE WITH CLOSED LOOP TOWER SYSTEMS. Closed circuit systems utilize a heat exchanger to separate process water from tower water. Process water is isolated from the contaminants contained in the tower water loop keeping the process water clean and easily maintained. Closed circuit systems can minimize contamination and maintenance of hydraulic heat exchangers, molds, rolls, chiller condensers and other equipment. HEAT EXCHANGERS... Advantage uses plate and frame heat exchangers for long service life and high efficiency. Phone: 7-887-079 WET DECK... PVC wet deck permits greater capacity in a small physical space. Computer designed stacked honeycomb channels allow for greater water flow and increased air volume. DRIFT ELIMINATORS... placed above the stationary water distribution header to prevent water drift from the top of the cell. Drift eliminators and air inlet louvers combine to save water, prevent winter icing and maintain a dry area around the cell. INSPECTI COVERS... easy to remove and to reinstall. A seamless gasket seals the cover to prevent water leakage. Fasteners attach the cover to the shell. The inspection openings are used for spray head maintenance and are large enough for wet deck replacement. SPRAY HEADS... the computer designed water distribution header assures complete wet deck coverage under a wide range of flow rates. The spray heads have no small orifices to plug. The PVC header is stationary, with no rotating spray trees that create excessive pressure drop and waste system pump capacity.

EXPANDED CELL UNITS Expanded cell units offer exceptional flexibility and larger capacity in a small physical space. Expanded cell units have a single self-supporting structural base and are shipped complete with no field assembly required. Single water inlet and drain connections eliminate the need for on-site manifolding for TC-70F through TC-70F models. TC-5F through TC-50F models have inlets and drains. The fans on the expanded cell units can be staged based on tower water temperature to match cooling capacity to the process cooling load. Model TC-70F TC-0F TC-70F TC-5F TC-05F TC-50F Capacity Stages 0% - 50% - 00% 0% - 50% - 00% 0% - 50% - 00% 0% - % - 00% 0% - % - 00% 0% - 50% - 00% 50 ton Power Tower cooling tower TOWER STANDS Tower stands are used to elevate the tower when a remote above ground tank is used in the system. Competitive fiberglass and galvanized towers require special structures. Power Towers require only four steel posts, one at each corner. Build your own stand using drawings supplied by Advantage or purchase the stand from Advantage as a part of a complete system. Optional tower stand catwalks with railings and ladders are available.

STANDARD FEATURES TOWER DESIGN: Designed, developed and manufactured by ADVANTAGE Single or expanded cell designs Total non-ferrous wetted surfaces Single inlet and drain connections on models up to 70 tons Two inlet and drain connections on models from 5 to 50 tons Counter-flow air movement Structural galvanized steel base on 5 to 5 ton models Structural painted steel base on 70 to 50 ton models SHELL CSTRUCTI: High strength fiberglass molding / of structural thickness in reinforced areas UV stabilized coating Acrylic adhesive bonding between shell halves Polyurethane sealant FAN: Air foil shaped blades for increased air flow Glass filled polypropylene blades Direct drive Factory set for maximum air movement MOTOR: TEFC construction Mounted on a stainless steel frame Supported on reinforced fiberglass shell area Mounted to shell with stainless steel fasteners DISTRIBUTI HEADER: Non-ferrous PVC construction Stationary Computer designed spray pattern Large orifice spray heads ABS spray heads Drift eliminator prevents over spray and water loss INLET LOUVERS: PVC construction Easily removed for cleaning Vertical orientation to eliminate splash out Directs air flow at proper angle for even distribution into wet deck Helps prevent air-borne debris from entering cell WET DECK: Stacked honeycomb pattern maximizes water and air flow for greater cooling efficiency PVC construction INSPECTI COVERS: Easily removed Seamless gasket sealing Allows for inspection of cell interior and replacement of wet deck WARRANTIES: 0 year shell warranty 5 year motor/fan warranty OPTIS FAN STARTER KIT: Motor starter Nema enclosure Fan thermostat SIDE OUTLET: (Required when no remote tank will be used) PVC flange Factory installed BASIN FLOAT VALVE: (Required when no remote tank will be used) Mechanical float and valve / supply connection Factory or field installed TOWER STAND: 0 corner post design with cross bracing Ladder and railing attachments ENGINEERING DESIGN SERVICE Factory Phone: 7-887-079 Advantage staffs a complete CAD based Engineering Department with experienced water system designers. Working from customer supplied facility and process information, Advantage designers analyze the entire system and select the correct component combinations to provide the most efficient output. If one of our standard systems does not fit your application requirements, then Advantage will design a custom system from a long list of available options. With the purchase of an Advantage tower water system, water distribution drawings are provided for contractor bidding and installation work.

SPECIFICATIS POWER TOWER SPECIFICATIS WATER CAPACITY FAN (direct drive) MOTOR TOWER CNECTIS (inches) DIMENSIS (inches) WEIGHTS (lbs) Capacity (tons) Flow rate (gpm) Quantity RPM CFM (total) Quantity Total nameplate HP Amps @ 0//0 Amps @ 0//0 Amps @ 575//0 To Tower From Tower (drain) Height Length Depth Dry Wet Shipping TC-5F 5 5,70,00 9..8.9 8 0 9 75,70,00 TC-85F 85 55,70,700 5 5. 7.. 8 7,90,00,580 TC-05F 05 5,70 5,000 0 8.0.0.0 8 7,90,00,80 TC-5F 5 05 0,500 7.5.0.0 9.0 0 9 85,,00,950 TC-70F 70 50,70,00 0 0. 5.. 0 8 5,0 5,00,0 TC-0F 0 0,70 50,000 0 5.0 8.0.0 0 8 5,50 5,0,50 TC-70F 70 80,000 5.0.0 8.0 0 0 9 9,5 7,800,5 TC-5F 5 95,70 7,88 0 @ @ 0 0 7,000 0,700,000 TC-05F 05,5 9,500.5.0.0 7.0 @ @ 0 0 5 9,50,000 5,50 TC-50F 50,0,000 0 88.0.0.0 @ @ 0 0 8 9 5,800 5,000,800 SHIPPING & RIGGING Power Tower cooling towers are shipped via standard trucking services. 5-5 ton cells are shipped with motor and fan assembly attached. The structural base is attached in the field. This allows the cell to be shipped in standard enclosed tractor-trailers. 70-50 ton cells are shipped completely assembled on low bed trailers. Other than rigging the tower cell into place the only required on-site task is the installation of the precut inlet louvers. OTHER PRODUCTS Pump Tank Stations Chilled & Tower Water, 50-00 Gallons Central Chilling Modules Air & Water-Cooled, 5-00 Tons Portable Chillers Air & Water-Cooled, / - 0 Tons Model Designator for Power Tower Cooling Towers TC - 5F Cooling Tower Construction F: Fiberglass Tons of Capacity Cooling Tower Cells Fiberglass or Metal, 5-50 tons Temperature Controllers Water & Oil Units, 0-500 F Central Chilling Packages Air & Water-Cooled, 0-00 Tons Phone: 7-887-079 ADVANTAGE PRODUCTS: TEMPERATURE CTROLLERS PORTABLE CHILLERS CENTRAL CHILLERS PUMP TANK STATIS TOWER SYSTEMS FILTERS ADVANTAGE ENGINEERING, INC. 55 East Stop 8 Road Greenwood, IN phone: 7-887-079 fax: 7-88-77 web site: www.advantageengineering.com email: sales@advantageengineering.com 00 ADVANTAGE ENGINEERING, INC. Form #ADV-59 5/0 SINCE PRODUCT INNOVATI AND IMPROVEMENT IS OUR CSTANT GOAL, ALL FEATURES AND SPECIFICATIS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR LIABILITY.