Linea 2.5. Linear Direct/Indirect LED

Similar documents
Linea 2.5. Linear Indirect LED

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

Linea 3.5. Linear Direct/Indirect LED

Grüv Flare Regressed. Recessed Linear LED

Linea 1.5. Linear Direct/Indirect LED

Grüv Flare Regressed. Recessed Linear LED

Linea 1.5. Linear Direct Wall Wash LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Performance Chart Electrical Data

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Evoke 2.9" HP. 2.9" Square Downlight

Hornet HP. Square Glass Downlight

Hornet HP. Round Glass Downlight

Etch 2' x 2' Recessed LED

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Performance Chart Electrical Data

Evoke 2.9" HP. 2.9" Square Downlight

Murro HP. 3.5" Round Surface Canopy Wall Wash

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Adjustable C3

Evoke Square Downlight

Evoke Square Adjustable C3M

Classix 6" 6" Round Lens Downlight

Evoke Square Downlight

Velato. Recessed Slot Adjustable Multiples

Evoke Square Adjustable HP

Evoke Square Downlight

Hornet HP. Recessed 4-Light Square Multiple

Evoke Square Adjustable HP

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke Round Adjustable C3

Performance Chart Electrical Data

Performance Chart Electrical Data

Evoke Round Downlight

Essenza. Square Downlights

Essenza. Round Downlights

Classix 6" 6" Round Downlight

Classix 6" 6" Round Adjustable C3

Performance Chart Electrical Data

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Cylindrix III Mini. 3.5" Round Surface Canopy

HORNET-HP-R- A14-3 3LT LED

VESICA LINEAR SUSPENDED VES L

LUX PENDANT DIRECT/INDIRECT

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

RECESSED Spec Guide. up to 111 lm/w performance

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

SURFACE Spec Guide. up to 105 lm/w performance

FULL BLEED APPLICATION SHOT RENDERING

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

RECESSED T-Bar & Drywall

LIGHT CHANNEL 45 COMPLETE FIXTURE

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

LIGHT CHANNEL TRIM 1.6

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

RECESSED - WITH StepLens OPTION

M100 LED Direct/Indirect

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

NOVA CEILING WALL GRAZER WITH REMOTE POWER

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

DHL-LP-LED Low Profile LED Linear High/Low Bay

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

Claude Indirect Wall WALL

Recessed LED Wall/Slot SAE 202

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

M60 LED Recessed Wet Location

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Truss Surface SURFACE

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Project Name. Date. Cat. Number. Type

Max 4 Flush Lens RECESSED

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

OLS-R-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL RECESSED LINEAR DIRECT SYSTEM 2" 4"

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

WARRANTY LED ECO PANEL.

3.75 Gyro Shift Multiples Single Head

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Catalog Number. Notes

DIMMING 0-10V Continuous

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

Transcription:

a 2.5 Features a 2.5" drives your design scenario, seamlessly. Streamlined and flexible, these architectural LED pendants provide the freedom to create truly dynamic spaces. synthesis of aesthetics, performance and energy efficiency, the a family delivers on its promises. a 2.5" complements our Gruv 2.5" products. Product Overview Type: Direct/Indirect Lens Down/atwing, Clear lens up Wattage: 5W/ft, 10W/ft (other wattages available see p2) Lumen Output: 8,299 max; 104 Lm/W (10W/10W, 4ft fixture) Color Temp: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) Dimming: 0-10V, 1% dim (standard) Lutron Hi-lume 3 wire, 1% dim Lutron Hi-lume EcoSystem, 1% dim Lutron Hi-lume 2 wire (120V only) Lutron Hi-lume EcoSystem, 1% dim, fade to off Lutron Hi-lume 5 Series DLI dimming, 0.1% dim 5 Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot Delivered Lumens LPW Color Temp 10 4,476 116.4 3000K-83 20 8,299 104 3000K-83 Data is based on 3000K-83 IES files available on website Data is based on 4' fixture with Performance Lens direct & Upper Clear lens indirect Runs Individual Runs: 2' - 8' (whole foot standard) Continuous Runs: vailable (whole foot standard) Custom: Made to measure available (nearest 1/8" of field dimensions). Requires approval drawings. dded cost & lead time. Electrical Data Wattage Per Foot 10 20 System Watts 4' 8' mps System Watts Electronic multi-volt (120V-277V), constant current LED driver mps 120V 44.6 0.36 83.8 0.70 277V 45.8 0.18 83.2 0.32 120V 84.2 0.70 168.4 1.40 277V 83.0 0.30 166.0 0.60 Standard Patterns " " " " Wall to Ceiling Custom* Yes Yes Yes Yes Yes No Yes " " " " " " * Submit drawing, consult factory LIT-2051 11/15/18 Page 1 of 9

Ordering Information LIN2.5DI-16 120/277 8 9 1 2 3 4 5 6 7 10 11 12 1 Model LIN2.5DI-16 8 Voltage 120/277 2 3 4 Optics (select 1 from each list) Direct: PL - performance lens (standard) DL - designer lens Indirect: UC - clear cover (standard) T - batwing uplight Mounting SW10 - through ceiling tile or gyp board, white, 10' SW20 - through ceiling tile or gyp board, white, 20' S10 - through ceiling tile or gyp board, black, 10' S20 - through ceiling tile or gyp board, black, 20' SW10T - over ceiling tee, white, 10' SW20T - over ceiling tee, white, 20' S10T - over ceiling tee, black, 10' S20T - over ceiling tee, black, 20' WM - wall mount Circuiting 1 - single circuit 2 - up/down switch separately 9 10 Length x x (Length ) (Length ) (Length C) Length (used for) Length (used for) Length C (used for) - all patterns - all patterns - PU - IND - PR - 2 lengths - PZ - CON of 2 - CUS Configuration IND 1 - individual fixture, 2' to 8' in 1' increments CON - continuous run > than 8', specify to nearest foot CUS - custom made to measure, +/- 1/8" of customer supplied field dimensions Standard Patterns (see page 6 for details): PLL - L left, (2) straights + (1) 90 corner, leg right PLR - L right, (2) straights + (1) 90 corner, leg left PU - U shape, (3) straight lengths + (2) 90 corners PR - Rectangle, (4) straight lengths + (4) 90 corners PZ - Z shape, (3) straight lengths + (2) 90 corners Custom Patterns: PC - please provide drawings and consult factory 5 6 7 Wattage (per foot) 5/5 10/10 5/10 10/5 Consult factory for other wattage options Note: 3' units must use same wattage for D/I components Note: 5' & 6' units not available in 10/10 Color Temp 83 CRI: 27-2700K-83 30-3000K-83 35-3500K-83 40-4000K-83 92 CRI optional, consult factory Finish HW - high reflectance matte white T - black texture ST - silver texture For other RL color, consult factory 11 12 Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Options/ccessories ENLS - Enlighted Sensor (0-10V driver only not available on 2' & 3' lengths, can only be used on one circuit) EMC-PF 2 - emergency circuit requires power feed located in last fixture section (for other locations consult factory) PF 2 - Extra power feed for additional circuiting 1 - Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. 2 - Not available with IND (individual) configuration. The "" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your merlux representative for explanations of changes. LIT-2051 11/15/18 Page 2 of 9

Specifications pplication Open office plan, conference rooms, corridors or any indoor retail space where an exciting combination of direct and indirect ambient lighting is desired. Construction One piece extruded aluminum housing. Die-cast End Plates match fixture body finish. Die-formed, cold-rolled steel internal components are protected against rust and corrosion. Optical Direct: ll Direct lenses are snap-in, extruded acrylic, with a maximum length of 8". merlux's proprietary acrylic lens provides excellent transmission while effectively concealing source image. PL - Performance Lens provides high efficiency with controlled lens surface brightness (standard). DL - Designer Lens provides flat even glow on lens. est when lens is in direct or constant view. Indirect: Extruded acrylic lens with a maximum length of 8. UC - Upper Clear lens cover (standard) T- atwing uplight lens (optional) spreads light directly above fixture. minimum of 18" distance between ceiling plane and top of fixture is suggested. LED merlux's boards and patented connector design with brand name LEDs enables merlux fixtures to have excellent thermal management and offer a 5 year warranty. Our LED binning is within 3 Macdam ellipse. oards are configured for maximum flexibility resulting in even illumination no matter what the fixture layout. LED boards are easily replaced in the field with just a Phillips screw driver. Color Temperature Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typical, 92 optional - consult factory R9: 16 @ CRI 83 R9: >50 @ CRI 92 Life: 50,000+ hr., > 70% of initial lumens (L70) Electrical Wiring: Individual and "eginning of Run" (OR) fixtures are prewired with power cord. ll configurations have quick connect power harnesses for row connections. 1-1 Circuit, direct & indirect same circuit 2-2 Circuits, direct & indirect switch separately (power feed at both ends). Standard Wattage: 5W/ft, 10W/ft. Optional Wattages: 3W/ft, 4W/ft, 6W/ft, 7W/ft, 8W/ft, 9W/ft. (3W & 4W have a minium length of 4'). For other wattages consult factory. Emergency circuit via remote inverter or auxiliary emergency power supply (by others). This product complies with IEEE C62.41 for surge endurance up to 2.5KV. merlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. ENLS - Enlighted Sensor (0-10V driver only, not available in 2' & 3' lengths, and can only be used on one circuit) EMC-PF - Emergency circuit requires power feed to be located in last fixture section for continuous runs. For other locations consult factory. Not available for individual (IND) configuration. PF - Extra power feed for additional circuiting. Not available for individual (IND) configuration. Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). Cap leads for non-dim applications. Optional Drivers: HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Finish ll painted surfaces are premium powder coated baked on for maximum durability and color stability. HW - High reflective matte T - Texture ST - Silver Texture For special paint colors supply RL and/or actual paint chip for factory consultation. Configurations/Lengths IND - Individual fixtures are made of single standard lengths of 2 ft to 8 ft (in 1' increments). These are stand alone fixtures with matching End Caps, supplied with the mounting hardware. Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. CON - Continuous runs, > 8' specified to nearest whole foot length in 1' increments. Runs made from standard lengths have End Caps at the beginning and end of run. Runs > 60' may require second power feed. Each Housing has factory installed alignment pins. Mating fixtures are easily aligned and joined. Wiring is made fast and positive with molded quick connectors. CUS - Custom made to measure runs are made to nearest 1/8"of customer supplied field measurements or drawings. Custom lengths use the same hardware for hairline joining. PXX- Standard Patterns consist of 90º corners with standard lengths (4' to 8' in 1' increments), continuous runs or made to measure lengths. Depending upon complexity of the pattern drawings may be required from the customer. If ordering please give overall lengths. '-'-PLL - L Left - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PLR - L Right - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PR - Rectangle - (4) 90º Corners joining 4 segments. Specify overall segments: & '-'-C'-PU - U shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C '-'-C'-PZ - Z shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C See page 6 for layouts. PC - Custom Patterns may use standard lengths, Made To Measure, 90º or other corners (some limitations). Please provide drawing and consult factory. Mounting The a 2.5 Direct / Indirect is intended to be pendant or wall mounted in continuous rows. For indirect lighting merlux suggests 18" min from top of fixture to ceiling. Standard or custom patterns available. LIN2.5DI-16...SW10 - Direct / Indirect pendant installed in center of ceiling tile or gypsum board ceiling (standard) i.e. SW10. Or if canopy is installed on a grid Tee runner add, T i.e. SW10T. Cable Suspension: Cable is stranded stainless steel wire. ll fittings are protected against rust and corrosion. Canopies are 5" x 1/4" die formed painted steel. djustment mechanism allows for infinite height adjustment. merlux recommends the required feed and non-feed suspensions based upon length and electrical options. Options include: color of canopy and power cord (black or white), length 10' or 20', and mounting condition, in center of ceiling tile and in gypsum board ceiling (standard) i.e. SW10. Or if canopy is installed on a grid Tee runner add, T i.e. SW10T LIN2.5DI-16...WM - Direct Indirect Wall Mounted using steel cleat bracket attached to fixture housing and wall bracket with set screws. Two bracket assemblies are used for each length under 8'. third center bracket may be recommended. J box required at feed locations. Please note: 1 Circuit is standard, the direct & indirect are on the same circuit. 2 Circuits, direct & indirect switched separately with power feeds at both ends. Certifications pproved to UL standards for damp locations as tested by CS Intended for indoor use only Warranty merlux's 5 year limited warranty. Please consult merlux website for details. LIT-2051 11/15/18 Page 3 of 9

LINE 2.5" DIRECT/INDIRECT 1 1 /8" 1/2" Power Suspension Kit location 3 1 /2" 3 1 /2" 2 11 /16" 3/32" Overall length of run LINE 2.5" DIRECT/INDIRECT WLL MOUNT 6" Mounting O. C. location 1/2" 2 11 /16" 3 3 /16" 3/32" Overall length of run LIT-2051 11/15/18 Page 4 of 9

CLE KIT SUSPENSION OPTIONS: CEILING OR GYPSUM ORD (SW10, SW20, S10, S20) 1/4"-20 x 3/4" L Philips Flat Head Screw FEED J-ox secured to structure above by others Countersunk 1/4"-20 Gem ar Strain Relief ushing N0N-FEED 1/4"-20 rod or wire secured to structure above (by others) Cat# Length Cord/Canopy pplication SW10 10' white/white ceiling tile/gypsum SW20 20' white/white ceiling tile/gypsum S10 10' black/black ceiling tile/gypsum S20 20' black/black ceiling tile/gypsum SW10T 10' white/white ceiling tee SW20T 20' white/white ceiling tee S10T 10' black/black ceiling tee S20T 20' black/black ceiling tee 5" Canopy Power Cord 5" Canopy Two piece Cable Coupler Cable Tie (1 per foot) 1/16" Cable Gripper/Locknut (size will vary) TEE GRID OR SCREW SLOT (SW10T, SW20T, S10T, S20T) FEED Drop Ceiling J-ox (supplied) Drop Ceiling T-ar by others (for Drop Ceiling application) NON-FEED Drop Ceiling T-ar by others IDS Clip with 1/4"-20 Stud by others 5" Canopy LIT-2051 11/15/18 Page 5 of 9

4 FT OR 8 FT OPTIONL ENLIGHTED SENSOR: merlux and Enlighted have partnered to create building environments that are safer, and smarter, than ever before. t the heart of our partnership is Enlighted's Smart Sensor, the most advanced digital sensor available today. Integrated into merlux products, the sensor seamlessly collects and communicates dense data on building security, occupancy, performance, environmental conditions, ambient light levels, temperature, and energy consumption. This intelligence provides building managers with unprecedented guidance on cost savings and site-planning efficiencies. Enlighted Sensor (ENLS) is available with 0-10V driver only. Minimum run length is 4'. Enlighted power pack is provided with ENLS option. RUNS Optional Enlighted Sensor 8 8 LINE 2.5" PTTERNS: Standard Patterns ll corners are standard 90, standard length legs. Use standard lengths: 4' min to 8' in 1 foot increments. Continuous runs must be the same length in pairs for closed configuration. Custom Patterns Please provide drawings of your configuration. Made to Measure: +/- 1/8", consult factory. PC - custom pattern, please provide drawings and consult factory 7 1 /4" 90 7 1 /4" a 2.5 Lens Mitered Lens PLL PLR PLL - L Left, (2) straights + (1) 90 corner, leg right PLR - L Right, (2) straights + (1) 90 corner, leg left Provide overall lengths: ' & ' Nomenclature: --PLL --PLR PR - Closed Rectangle, (4) straight lengths + (4) 90 corners Provide overall lengths: ' & ' Nomenclature: --PR C C PU - Open U, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PU PZ - Open Z, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PZ LIT-2051 11/15/18 Page 6 of 9

FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.63 0.82 1.0 1.17 1.34 1.50 1.64 Factor: 0.93 1.0 1.08 1.15 LINE 2.5 DI PERFORMNCE LENS DIRECT/CLER COVER INDIRECT 5W UP/5W DWN 3000K 4FT Total Watts: 38 Total Lumens: 4,476 Source: 256 LED's 180 LTL# 1238334 LTL# 1238335 165 150 135 180 165 150 LINE 2.5 DI PERFORMNCE LENS DIRECT/CLER COVER INDIRECT 10W UP/10W DWN 3000K 4FT Total Watts: 80 Total Lumens: 8,299 Source: 256 LED's 135 120 120 105 105 225 450 675 900 1125 90 500 1000 1500 2000 90 75 75 60 60 0 15 30 45 0 15 30 45 ZONL LUMEN SUMMRY Zone Lumens %Fixt 0-40 1065 23.8 0-60 1730 38.7 0-90 2093 46.7 90-180 2384 53.3 Efficacy = 116.4 Lumens /Watt ZONL LUMEN SUMMRY Zone Lumens %Fixt 0-40 1970 23.7 0-60 3194 38.5 0-90 3855 46.5 90-180 4444 53.5 Efficacy = 104 Lumens /Watt COEFFICIENTS OF UTILIZTION Effective Floor Cavity Reflectance 20% RC 80 RW 70 50 30 10 RCR (expressed as lumens delivered to the task surface) 0 4761 4761 4761 4761 1 4354 4165 3995 3842 2 3973 3649 3381 3156 3 3631 3217 2897 2642 4 3327 2854 2508 2244 5 3058 2548 2192 1929 6 2820 2289 1934 1678 7 2610 2070 1720 1475 8 2423 1881 1541 1307 9 2257 1719 1389 1167 10 2109 1578 1260 1048 COEFFICIENTS OF UTILIZTION Effective Floor Cavity Reflectance 20% RC 80 RW 70 50 30 10 RCR (expressed as lumens delivered to the task surface) 0 8821 8821 8821 8821 1 8068 7718 7404 7121 2 7363 6764 6268 5851 3 6730 5964 5371 4898 4 6167 5292 4651 4161 5 5668 4724 4065 3578 6 5226 4245 3586 3113 7 4837 3837 3190 2736 8 4491 3488 2857 2424 9 4184 3187 2577 2164 10 3910 2925 2336 1944 LIT-2051 11/15/18 Page 7 of 9

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- 0-10V - DIMMING (Standard) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox Lutron: Wattstopper: Leviton: Diva - DVSTV DF-120277 Renoir II Maestro - MS-Z101 Nova-T - NTSTV-DV Center System Lutron Grafixk Eye with GRX-TV1 Interface 0-10V Dimming Gray Purple Driver 0-10V (-) 0-10V (+) Switched Hot V+ V- Red LUTRON HI-LUME DIMMING Integrates into Lutron EcoSystem building management 120V or 277V* Dims down to less than 5% light output May use 3-Wire or EcoSystem Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox (3-Wire Dimming) Lutron: Diva Maestro Nova-T Vareo Center System Lutron EcoSystem compatible controls HILUME--DH 3-Wire Wiring Diagram Cap unused ECOSYS wires 3-Wire Phase Dimming Purple Stripe Purple Orange E1 E2 Driver Dimmed Hot Switched Hot HILUME--ECO, HILUME-H-ECO, HILUME-5-ECO EcoSystem Digital Wiring Diagram E2 E1 ECOSYS us EcoSystem Dimming Purple Stripe E1 Driver Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot V+ Red V- V+ V- Red * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2051 11/15/18 Page 8 of 9

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- LUTRON HILUME--LTE DIMMING Utilizes Standard incandescent dimmers that are in wide use in installations across the US. est for retrofit applications where TRIC dimmers are installed. 120V only Dims down to less than 1% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers : Wall ox (Incandescent Style, Wattage as required) Lutron: Diva Maestro Nova-T Vareo Skylark Center System Lutron "GP" Panel Lutron Grafik Eye QS Lutron HILUME--LTE Wiring Diagram TRIC Dimming Driver V+ V- Red DLI - DLI DIMMING 120V-277V Digital control protocol allows individual fixture control DLI Wiring Diagram 120V - 277V* Dims down to 0.1% light output in most cases DLI Dimming Purple Purple/WT DLI us Driver V+ Red Compatible Dimmers : Wall ox Leviton CD250 ler V- Center System Dynalite Fifth Light * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2051 11/15/18 Page 9 of 9