Self powered Thermostatic Radiator Valve, itrv Type MVA 003

Similar documents
Mounting instruction and operating manual

PIR Occupancy & Motion Sensor

Home Control Radiator Thermostat. first steps

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF

User s guide Personal radio trigger Erik 9100

Operating instructions

600 Watt Dimmer Install Guide

User Manual - Energenie MiHome etrv

Alarm System SECURE AS 302

WIRELESS FRIDGE THERMOMETER Instruction Manual

Instruction manual. Remote control electric IR HEATER

Operating manual. Radiator Thermostat ETKF+

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

for relative humidity and temperature with calibration certificates

SMOKE User Manual. NE v2.0

1126 Series Ceiling Mount PIR Motion Detector

Installation and User Guide living connect Electronic Radiator Thermostat

Electronic Thermostat With RF

ZIG-TRV-01 ZigBee Thermostatic Radiator Valve Install Guide V1

Model: RT310RF. Installation Manual

Installation & Operating Instructions

WS INSTRUCTION MANUAL LED WEATHER STATION WITH RADIO CONTROLLED CLOCK AND ALARM

SRT321 User and Installation Instructions

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Movement controller comfort, Flush-mounted (Up) xx, xx

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

SMART THERMOSTAT WITH HOT WATER CONTROL

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

POP_ Smoke Detector

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

ThermoPlus AS2-RF & ASR-RF Installation Instructions

Laser Distance Sensor Type M Analog-Output

Installation and User Guide eco Intelligent Radiator Thermostat

Honeywell Temperature & Humidity Sensor with LCD

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

WatchDog Wireless Crop Monitor Operation Manual

OUR NEW ENOCEAN PRODUCTS

Powerley Thermostat. Installation & Operation Guide

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Product Announcement

OPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

C-Stat 17-ZW User Instructions

Set & $ave. Model Programmable Thermostat. installation and operation manual

X64 Wireless Training

Professional Wireless Rain Guage with 4" LCD

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Beacon 800 Gas Monitor Operator s Manual

ULTRASONIC OIL LEVEL MONITOR & ALARM

U S E R M A N U A L UBH1RF HEAT ALARM

1125 PIR Motion Detector

Ion Gateway Cellular Gateway and Wireless Sensors

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Wireless Weather Station with Solar Transmitter Instruction Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

POP_ Smoke Detector

Instructional & Operating Manual

Operating instructions

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Programmable Thermostat

Thermostatic Actuators

Wireless sensor transmitters should be installed within 200 to 500 feet of the RC2100 Controller.

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL 1. INTRODUCTION 2 2. INSTALLATION 2

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

INTRODUCTION CONTENTS

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

Original operating instructions Safety switch with guard locking AC901S AC902S

GSM RFID VOICE Alarm System

Heating Control Danfoss Link & Connect Thermostats

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Remote alarm unit Art. Nr.:

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

Installation Instructions EFS Hand Washing Station

Digital Thermometer with Ice Alert and Clock

Portable Air Conditioner User Manual

Q3200 Smart Home Alarm. Kit Content and Installation Guide

CS027 User Instructions

UP 258E11 OPTISENS OFFICE

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Operating Instructions Version 1.2

Operating instructions

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

VMB1TSW Temperature sensor module for the Velbus system

User Manual THR872CUK Wireless Programmable Thermostat

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

Q3000 Smart Home Alarm. Kit Content and Installation Guide

Transcription:

User Guide Self powered Thermostatic Radiator Valve, itrv Type MVA 003 Dear customer, Thank you for choosing our product. Before starting up the device, please read the entire instructions carefully. Save the instructions for later reference and keep them together with the device if you pass it on to someone else. For technical support, please contact: EH4 GmbH Phone: +49 7665 932 18 33 E mail: info@micropelt.com www.micropelt.com/itrv.php

Contents 1 USE AND SAFETY RECOMMENDATIONS 3 2 INCLUDED IN THE BOX 4 3 OVERVIEW 5 3.1 System Function 5 3.2 Proper use of the device 5 4 USAGE 6 4.1 Default setting on delivery 6 4.2 Setting up the actuator to connect to the room controller 6 4.3 Setting the mounting position 6 4.4 Attaching / removing the valve actuator to the radiator 7 4.5 Calibration cycle and wireless operation 7 5 ADDITIONAL INFORMATION 8 5.1 Powered by Energy Harvesting 8 5.2 Status indicators and LED flash patterns 8 5.3 Notes on radio operation 9 6 RADIO PROTOCOL 10 6.1 Protocol Data Overview 10 6.2 Description of individual functions 10 6.3 Example of a radio protocol 11 7 TECHNICAL DATA 12 8 HELP AND TROUBLESHOOTING 13 9 CARE AND MAINTENANCE 14 10 DISPOSAL 14 User Guide_MVA-003_V1_0517 Page 2

1 Use and Safety Recommendations The metallic part of the unit s housing serves as a heat sink. Be sure that furniture, curtains, plants, or other objects do not obstruct the air circulation around it. If the device has been stored in a cold environment, make sure that it resumes close to room temperature before use. This is to prevent condensation from forming. The thermostatic radiator valve is designed for indoor use only. Do not allow the thermostatic radiator valve to get wet. Its sensitive electronics can be affected. The unit is best cleaned with a dry or slightly damp cloth. Do not use aggressive cleaning agents or solvents. Refrain from exposing the unit to environmental stress such as high mechanical forces (do not step on it), strong vibrations, direct sunlight or extreme temperatures. The unit must not be disassembled or modified. In case you are unsure how to use the unit, please get in touch with your beta test consultant. Be aware that correct operation can be affected by strong electromagnetic fields. Typical sources of such are mobile phones, 2 way radios, RC transmitters, microwave ovens, electric motors. The housing contains actuated springs that can lead to injuries if released. For servicing, refer to qualified service personnel. The thermostatic radiator valve has been designed and must solely be used for the purpose of controlling a M30 x 1.5 heater valve. Any other use may pose a hazard to the device itself, to the equipment involved, or to the health of the user. When operating the device in a workplace environment, be sure to observe the workplace regulations that may apply. Read these instructions carefully and keep them for later reference. Thank you. User Guide_MVA-003_V1_0517 Page 3

2 Included in the box 1. Self powered thermostatic radiator valve actuator, one unit Type: MVA 003 2. Quick start instructions The connection nut of the actuator can be used universally and fits all valves with a thread size of M30 x 1.5. This covers valves of the most popular manufacturers, without requiring accessories. For other valve types normally metal adapters are available. Supported valves without adapter are: Heimeier, MNG, Junkers, Landis&Gyr (Duodyr), Honeywell Braukmann, Oventrop Typ A, Oventrop AV6, Schlösser, Comap D805, Valf, Sanayii, Mertik Maxitrol, Watts, Wingenroth (Wiroflex) R.B.M, Tiemme, Jaga, Siemens, Idmar, plus several others. Metal adapters are available for Danfoss valves. Please get in touch. User Guide_MVA-003_V1_0517 Page 4

3 Overview 3.1 System Function The MVA 003, a self powered thermostatic radiator valve, is an electronic actuator for convection radiators (standard valve type M30 x 1.5). It is designed for single room temperature control. For this purpose, the actuator is mounted on the radiator valve and linked by radio (EnOcean 868 MHz) to a suitable room controller. A connection process is used to pair the devices and a calibration cycle allows the actuator to automatically adapt its positioning range to the individual radiator valve. With the room controller set up to control the actuator, the user can conveniently configure room temperature profiles using the room controller. By lowering the room temperature during periods of absence, heating cost can be reduced without loss of comfort. The actuator can be operated in 2 modes as described in the EnOcean equipment profile A5 20 01. Either with Set point value (%) or Set target temperature ( C) using its internal temperature controller and ambient temperature sensor. It queries the room controller every 10 minutes and reports its current valve pin Setpoint value. It also receives either a new Setpoint value between 0% (valve closed all the way) and 100% (valve open all the way) or a new Set temperature value between 0 C and +40 C. The actuator s servomotor then moves the valve pin to the new target position. The actuator generates the energy it needs for operation (running the motor and radio communication) with a built in thermoelectric generator (TEG). This generator draws its energy from the difference in temperature between the radiator heat and ambient air and therefore does not need an external power source, such as a battery or a wall socket, for operation. 3.2 Proper use of the device The self powered thermostatic radiator valve is suitable solely for controlling water filled heating radiators. Any other use including control of floor heating systems is not permitted and can result in damage. Do not disassemble or modify any part of the product. It is important to comply with the safety notice included in these operating instructions. User Guide_MVA-003_V1_0517 Page 5

4 Usage 4.1 Default setting on delivery On leaving the factory, the self powered actuator is in mounting position (valve pin is retracted or can be pushed in all the way without force). Its internal energy storage unit is fully charged, so there is more than enough energy for setting the unit up. When the heating system is running, the actuator is automatically powered by the heat from the heating circuit. 4.2 Setting up the actuator to connect to the room controller The actuator must be controlled by a suitable room controller (supporting EnOcean Equipment Profile EEP A5 20 01). The link between the two is established by a bidirectional connection process: First set the room controller to setup mode, as described in the instructions for the room controller. Then double press the button on the actuator. After approximately 2 seconds, the actuator will send a telegram to the room controller, which in turn confirms the reception. Successful completion of the connection process is confirmed by a single LED flash. If the connection operation fails, the LED flashes multiple times. In this case, repeat the operation. If multiple connection attempts fail, check whether the room controller is ready to receive, then repeat the connection operation. NOTE: Double pressing the button always causes a connection request to be sent. At the same time, it makes the actuator move to the mounting position and stops normal radio communication. For its use with Remote Management and Commissioning please get in touch with Micropelt (EH4 GmbH) 4.3 Setting the mounting position Pressing the button twice will always bring the actuator into the mounting position (valve pin fully retracted or can be pushed in all the way without force). This is also the default position for storage and shipping, with power consumption being minimized since radio communication is disabled in this mode. The primary use of the mounting position however, is attachment and removal of the actuator to/from the radiator valve (see Section 4.4). User Guide_MVA-003_V1_0517 Page 6

4.4 Attaching / removing the valve actuator to the radiator You do not need to interrupt the hot water circuit and water does not have to be drained, when mounting or removing the actuator. Instead, the radiator valve remains attached to the radiator while the actuator is screwed onto the valve, typically in lieu of a traditional thermostatic head. Follow the steps below: 1. If necessary, remove the mounted thermostat by turning its union nut counterclockwise. To loosen the nut, it can be helpful to set the thermostat to maximum. 2. Remove any contamination (dust, paint) that may be present on the part of the valve that is going to attach to the actuator. 3. Be sure the actuator is in mounting position, e.g. the pin is either fully retracted or can be pushed in all the way without force. If not, then press the button twice and wait until the pin has fully moved in and the motor stops running. 4. Now place the actuator on the radiator valve. Screw on the connection nut and tighten it. Note that this step is critical to the energy harvesting performance. 5. The actuator should now rest firmly against the contact surface of the radiator valve, which is the transfer point of the heat flux to the thermoharvester. After mounting the actuator, try to gently rotate it back and forth on the valve. It should not move. 4.5 Calibration cycle and wireless operation After attaching to the radiator valve, the actuator should be in the mounting position with wireless communication stopped. Enter normal operation of the actuator, by pressing its button once. This initiates a calibration cycle, in which the 0% position of the valve is determined. Following this, the actuator requests a position from the room controller, immediately setting the valve opening accordingly. Wireless operation is now active, with the actuator asking the room controller for new instructions every 10 minutes. The MVA 003 operates in 10 seconds communication cycle immediately following is mounting and activation. For this allows for quicker feedback and response for the first 10 minutes. Avoid double pressing the button now, since this may return the actuator to the mounting position, disrupting operation. During normal wireless operation, bidirectional communication with the room controller and correction of the valve opening takes place every 10 minutes. The LED remains off, unless radio communication fails, e.g. because the room controller is down. In this case, the LED flashes multiple times. An immediate response can be extorted at any time through pressing the button only once. NOTE: The pushbutton on the device is needed for setup and mounting / removal only. Frequent pressing of the button results in excessive valve actuation which can discharge the energy storage device and send the unit into a low power sleep mode. User Guide_MVA-003_V1_0517 Page 7

5 Additional Information 5.1 Powered by Energy Harvesting Power to the actuator is supplied by a thermoelectric generator (TEG). This extracts electrical energy from the difference in temperature between the heating water flow and the ambient air. During periods of radiator activity, excess energy is buffered in the internal energy storage device. The energy stored during the colder months of the year is used to supplement or replace the harvester output in summer as well as the spring and autumn transition periods. The storage device is sized to power the unit throughout the year, under conditions of normal heating behavior. In rare situations, the reservoir may run low. The actuator then reports this condition to the room controller and moves the valve into a protected position (50% valve opening or current position, if this is greater). The actuator then enters sleep mode and waits for the storage unit to recharge from the thermoelectric generator. Once sufficient electrical energy has been gathered, the actuator resumes operation. The above mentioned safe position ensures that the radiator valve does not calcify in one of its end positions, that pipes do not freeze, and that the thermoelectric generator is being heated once hot water starts flowing again. While in the safe position, the room temperature may fluctuate slightly. 5.2 Status indicators and LED flash patterns As part of the implemented EnOcean standard protocol, the actuator uses two flags to transmit to the room controller the status of the thermoharvester (1: charging; 0: not charging) and that of the energy storage unit (1: sufficiently charged; 0: charge low). Error codes are not transmitted. LED flash patterns: 1 flash: Connection process (teach in) successful 6 quick flashes: Connection process has failed User Guide_MVA-003_V1_0517 Page 8

5.3 Notes on radio operation 5.3.1 Transmission range The radio transmission range is limited by both the distance between transmitter and receiver, and by interference. Indoors, building materials play an important role. Major reflections and signal losses are due to metallic parts, such as reinforcements in walls and metallized foils, which are used on thermal insulation products. Penetration of radio signals: Material Penetration Wood, gypsum, uncoated glass 90..100 % Brick, chipboard 65.. 95 % Reinforced concrete 10.. 90 % Metal, aluminum facings 0.. 10 % For an evaluation of the environment, please see guide values listed below: Conditions Range / penetration Line of sight Typ 30 m range in passages, up to 100 m in halls Plasterboard and wood walls Typ 30 m range through max. 5 walls Brick and foamed concrete walls Typ 20 m range through max. 3 walls Reinforced concrete walls & ceilings Typ 10 m range through max. 1 ceiling Supply blocks and lift shafts should be treated as shields. In addition, the angle at which the signal enters the wall has to be considered. A shallow angle increases the effective wall strength as well as the attenuation of the signal. Whenever possible, signals should enter walls perpendicularly. Alcoves should be circumvented. NOTE: For additional information, refer to the EnOcean White Paper EnOcean Wireless Systems Range Planning Guide. 5.3.2 Other interference sources Common sources of interference are devices that generate high frequency signals. These are typically computers, audio /video systems, electronic transformers and ballasts. The distance of the actuator to such devices should be more than 0.5 m. 5.3.3 Loss of communication with the room controller If the actuator cannot establish a dependable radio communication with the room controller, i.e. more than 3 times in sequence the room controller does not receive a radio signal, then the actuator switches to a reduced radio pattern. The typical 10 minute radio period is extended to one transmission every hour, reducing the energy consumption while radio contact is interrupted. In addition, the actuator enters the safe position as described in Section 5.1. Once the radio contact to the room controller recovers, the actuator reverts to requesting instructions from the controller every 10 minutes. User Guide_MVA-003_V1_0517 Page 9

6 Radio Protocol Bidirectional radio communication occurs periodically according to the EnOcean Equipment Profile EEP A5 20 01 (Battery Powered Actuator). Communication is triggered by the actuator. 6.1 Protocol Data Overview Transmit mode from MVA 003 to controller/ gateway/ server Receive mode from controller / gateway / server to MVA 003 DB_3 Current valve position 0..100%, linear n=0..100 DB_3 New valve position 0..100% linear or Target temperature (0 40 C) Selection with DB_1.Bit_2 0) DB_2.Bit_7 Not used DB_2 Room temperature from room sensor DB_2.Bit_6 Active energy DB_1.Bit_7 4 Not used harvesting (valve is hot) DB_2.Bit_5 Energy storage sufficiently filled DB_1.Bit_3 Summer mode, transmit / receive time interval 8 hours DB_2.Bit_4 0 Not used DB_1.Bit_2 0 Setpoint Selection 0: Valve position (0 100%) 1: Target Temp. (0 40 C) DB_1 Internal temperature DB_0.Bit_7 4 Not used of MVA DB_0.Bit_7 4 Not used DB_0.Bit_3 LRN Bit, defined for data telegram DB_0.Bit_3 LRN Bit, defined for DB_0.Bit_2 0 Not used data telegram DB_0.Bit_2 0 Not used 6.2 Description of individual functions 6.2.1 Setpoint Selection Selection whether A5 20 01 and the actuator is used with Valve Position (Controller running in the room or building control system) or with its internal temperature control loop. 6.2.2 Valve position / Set temperature in actuator mode (DB_3) Based on 6.2.1 User Guide_MVA-003_V1_0517 Page 10

Target temperature ( C): The room control unit transmits a target temperature between 0 C and +40 C which will be used as by the internal control loop to calculate valve positions. Valve positon (%): From the external radio master a control value of 0..100% is transmitted and the valve actuator executes a valve movement (0% = valve closed / 100% = valve open). 6.2.3 Summer Mode (DB_1.Bit_3) When the actuator receives the status message Summer mode ON from the external radio master, then the valve opens and the transmit/receive interval is increased from 10 minutes to 8 hours. It is possible to wake up the itrv through 1 x pressing the push button. Then the itrv receives the new setting from the room controller. 6.2.4 Recognition of valve position The valve actuator recognizes during the teach in the closing position of the valve. During operation the valve actuator does a full stroke (self calibration) after every 30 movements, to avoid malfunction of the valve. It is not intended to trigger the recognition of the valve position via room controller. 6.3 Example of a radio protocol Radio protocol of valve actuator MVA 003 to server /controller /gateway Example in HEX "0x32 0x60 0x89 0x08" DB.3 = 0x32 = 50: valve position is 50% DB.2 = 0x60: DB2.Bit_5 = 1 (Energy storage charged) / DB2.Bit_6 = 1 (Harvesting active) DB.1 = 0x89 = 137: Internal temperature = 40*DB.1/255 = 40*137/255 = 21,5 C DB.0 = 0x08: Data telegram Radio protocol from server /controller /gateway to valve actuator Example in HEX "0x05 0x81 0x00 0x08" DB.3 = 0x05 = 5: new valve position is 5% DB.2 = 0x81 = 129: room temperature = 40*DB.2/255 = 40*129/255 = 20,2 C DB.1 = 0x00: DB_1.Bit_3 = 0: regular radio cycle 10 Minutes (no summer mode) DB.0 = 0x08: Data telegram Example in HEX "0x80 0x81 0x04 0x08" DB.3 = 0x80 = 128: New target temperature is 20,1 C DB.2 = 0x89 = 129: Room temperature = 40*DB.2/255 = 40*129/255 = 20,2 C DB.1 = 0x04: DB_1.Bit_3 = 0: Internal Temp. controller with 10min Duty Cycle (Summer bit not active) DB.0 = 0x08: Data telegram User Guide_MVA-003_V1_0517 Page 11

7 Technical data Maximum inlet temperature 70 C Valve type Linear travel of pin / max. calibration range Operating range (0 100%) Positioning time / positioning speed Step width M30 x 1.5 / others via adapters >3.8 mm 2.5 mm 0.2 mm/s < 0.1 mm Safety position Valve open > 50% Noise, normal operation Force of pin, normal operation Self calibration < 30dBa 100 N typical automatically Anti freeze safety position 95% valve open when T ambient < 5 C Normal operation when T ambient > 5 C Radio protocol EnOcean EEP A5 20 01, valve position in % (not temperature!) Carrier frequency 868 MHz Radio range Feedback approx. 30 m, depending on room situation State of charge, thermoharvester activity, valve position Radio interval, normal operation Every 10 minutes; 10 seconds for the first 10 minutes following its activation Indicator LED (for teach in of valve actuator) Control and temperature measurement Internal IP protection class IP4X according to DIN EN / IEC 60529 Ambient temperature during operation 0 50 C Shipping and storage conditions 0 70 C Weight 260 g Dimensions 59 x 64 x 83 mm (l x h x d) Class 3 appliance (SELV) Subject to change without notice! User Guide_MVA-003_V1_0517 Page 12

8 Help and troubleshooting Issue/indication Cause Remedy The motor makes a distinct sound during operation The gear has not yet finished acoustic optimization. None No response after pressing the button or Radiator stays hot, does not cool down Energy storage device is discharged Wait (if necessary overnight) until the energy storage device is recharged again by the heat of the valve. Radiator does not cool down Radiator does not heat up Unexpected response after pressing the button. Valve does not close all the way Air in the radiator Is the boiler water temperature okay? Is the heating pump on? The valve won't open. Is it calcified? Malfunction of the internal microcontroller Check mounting. Repeat calibration cycle. Test the valve with a standard thermostat head. If defective, contact your heating service or your property manager. Inappropriate valve adapter to M30 x 1.5. In this case please contact EH4. Vent the radiator and, if necessary, check the water pressure in the heating system. Correct the boiler water temperature/turn on the heating pump. Remove the actuator, press in the valve pin on the radiator several times with your hand or a tool. Reset the valve actuator: Press and hold the pushbutton for 10 seconds, then wait 3 minutes for the actuator to recover User Guide_MVA-003_V1_0517 Page 13

9 Care and maintenance Use a dry or slightly damp cloth for cleaning the actuator. Never use harsh cleansers or chemical solutions. 10 Disposal Do not discard the device with your household waste. Instead, drop it at an authorized collection center for scrap electronic equipment, in compliance with the Waste Electrical and Electronic Equipment Directive. User Guide_MVA-003_V1_0517 Page 14