Constant climate chambers

Similar documents
Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Constant climate chamber with humidity

Constant climate chambers

Constant climate chambers

Constant climate chambers

Plant growth chambers

KMF Environmental test chamber for constant climate

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

New Generation KBF 240 series

Environmental simulation chamber for complex alternating climate profiles

VD 53 - Vacuum drying oven for non-flammable solvents

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model KBWF 240 Growth chambers with light and humidity

Model KBF 240 Constant climate chambers with large temperature / humidity range

Model KBWF 720 Growth chambers with light and humidity

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Safety vacuum drying oven for flammable solvents

Vacuum drying oven for non-flammable solvents

Model KBF 1020 Constant climate chambers with large temperature / humidity range

BINDER Industrial. Product Catalog

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Constant climate chambers

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Vacuum drying VD VDL series

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

ULTRA.GUARD ultra low temperature freezer

Model C 170 CO 2 incubators with hot air sterilization

BINDER Scientific Product Catalog

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Drying and heating chambers

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

BINDER Product catalog

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

Environmental Chambers

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

ICH750L. Climate Chamber. Product specification

Photo Stability Chamber

Stability Testing according to GMP & FDA

Environmental Chambers

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Vacuum drying chambers. VD VDL series

ICH110. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification

Drying and heating chambers. Series ED FD FED FP M

PHOTOSTABILITY CHAMBERS

CO₂ incubators. C CB series

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Protect your research

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Laboratory Refrigerator/Deep Freezer TC 802

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

ENVAIR lab CO2 Tri-Gas Incubator

CO₂ incubators. C CB series

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

CO 2 Incubators INCO 2

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Chromatographic Air circulated Refrigerator, two-door TC 603

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Constant climate chambers HPP Humidity chambers HCP

Sunrise the beginning of a brand new day

NEW GENERATION. Efficient use of valuable space INCUBATORS

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Humidity Chambers HCP

SDR Dry Room. Outstanding performance

PHOTO STABILITY TEST CHAMBERS

Reproducible Climate...

Key benefits. Why Condair CP3?

Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

PHOTOSTABILITY CHAMBERS

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

incubator, the best in its class

Long Term Storage Cabinet

Digital, not analog: One manifold for all refrigeration systems.

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

EC 160 CO 2. Incubator

StableClimate Stability Chambers

Thermo Scientific Heraeus Heating and Drying Ovens

VACUUM HEATING AND DRYING OVENS Gentle and safe

Refrigerated Incubators / Environmental Testing Chambers

STABILITY TEST CHAMBERS

Stability Testing GMP- and FDA-Compliant Reliable Solutions for the Pharmaceutical Industry

Transcription:

Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the additional heat from the light and thus provides unambiguous, meaningful test results in compliance with guideline ICH Q1B, ption 2. The two sources for visible and UV light can be controlled separately, which provides higher accuracy for analysis. Performance features and equipment : Electronically controlled APT.line preheating chamber and refrigerating system assuring temperature accuracy and reproducible results ICH compliant illumination integrated into the doors, for photo-stability testing in accordance with ICH guideline Q1B, option 2 Temperature range -10 C (14 F) up to 100 C (212 F) - without humitiy Temperature range 20 C (68 F) up to 90 C (194 F) - with humitiy Humidity range 10 % RH to 90 % RH MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments Features: User friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real time clock Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A (R2) Inner glass door Independent adjustable temperature safety device class 3.1 (DIN 12880), with visual and audible temperature alarm Access port with silicone plug Ø 30 mm (1.18 inch), left side Safety connection kit for water supply and drainage, including water hose, total length 6 m (19.7 ft.) RS 422 interface for GLP/GMP and the FDA guideline 21 CFR Part 11 compliant APT-CM DataControlSystem software 2 stainless steel racks included BINDER test certificate

Technical specification KBF P 240 (E2) Temperature-humidity chart Exterior dimensions KBF P 240 (E2) Width 1034 / 40.7 Height (inclusive feet) 1142 / 45.0 Depth 746 / 29.4 Plus door handle, I - panel, connection Wall clearance rear (minimum) Wall clearance side (minimum) 100 / 3.9 100 / 3.9 160 / 6.3 Steam space volume (l/cu.ft.) 308 / 10.9 Height of water connections (± 3 mm / 0.12 inch) Number of doors 2 Number of inner glass doors 2 Interior dimensions 84 / 3.3 Width 800 / 31.5 Height 600 / 23.6 Depth 500 / 19.7 Interior volume (l/cu.ft.) 240 / 8.5 Racks, chrome - plated (number standard/max.) 2 / 7 Load per rack (kg/lbs.) 30 / 66 Permitted total load (kg/lbs.) 70 / 155 Weight of the unit (empty) (kg/lbs.) 184 / 405.7 The light area indicates the control range of temperature and relative humidity. The hatched area indicates the control range of temperature and relative humidity without condensation. Temperature data (without humidity) Permissible ambient temperature range 5) without humidity / without illumination without humidity / with illumination with humidity / without illumination 18-32 / 64.4-89.6-5 - 100 / 23-212 5-100 / 41-212 20-90 / 68-194 with humidity / with illumination 20-90 / 68-194 Temperature variation without humidity at 10 C (50 F) (± C) 0.4 at 37 C (98.6 F) (± C) 0.4 Temperature variation with humidity 2) (± C) Temperature fluctuation from 5 C (9 F) above ambient temperature 2) (± C) Temperature fluctuation when refrigeration system is in operation (± C) Heating up time 1), 2) at 37 C (98.6 F) (Min.) 30 Cooling down time from room temp. 1), 2) at 10 C (50 F) (Min.) 10 Recovery time after doors were open for 30 sec. 1), 2) at 37 C (98.6 F) (Min.) 5 at 50 C (122 F) (Min.) 4 1 0.1 0.5 Humidity fluctuation 2), 4) (± % RH) 1.5 Electrical data Housing protection acc. to EN 60529 IP 20 Nominal voltage (±10 %) 50 / 60 Hz (V) 230 Nominal power (kw) 2.42 Energy consumption 5) at 37 C (W) 730 Illumination data ICH compliant illumination in the doors in acc. Lux 4000

Technical specification KBF P 240 (E2) with ICH guideline Q1B ption 2 UVA (W/m²) 5) ICH compliant illumination underneath the ceiling in acc. Lux with ICH guideline Q1B ption 2 UVA (W/m²) 5) 1.7 4000 1.7 1) up to 98 % of the set value 2) value without illumin. 3) Upon door opening or water exchange in humidity cylinder: > ± 1.5 % RH, recovery time approx. 20 min 4) These energy consumption values can be used upon calculation of air conditioning systems. 5) Maximal value, measured in center of usable volume By bringing in a humidity source to the inner chamber the minimal humidity range is affected. A water tap (1 6 bar) with normal tap water (approx. 200 500 µs/tolerance +300 150 µs, total hardness appr.4-8 dh) is necessary for the installation of the humidifying and dehumidifying system. Furthermore, a 40 mm water drain with descending gradient is required. All technical data are specified for units with standard equipment at an ambient temperature of 20 C and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber.all indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.

ptions and accessories KBF P series Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50 and 100 mm diameter. APT-CM DataControlSystem GLP Edition Software for GLP compliant control, programming, and documentation. Permits networks of up to 30 units and/or controllers. Meets the requirements of FDA 21 CFR Part 11. BINDER Data Logger kits The new BINDER Data Logger kits for temperature and humidity can record temperature and humidity data of BINDER equipment. This finely tuned product solution also contains useful accessories for mounting the Logger on the BINDER unit, including cable bushings and a sensor mounting bracket. Calibration certificates and validation BINDER can significantly reduce the time and effort needed for equipment qualification and validation. We draw on unparalleled knowledge of our equipment applications and years of experience in certification.

ptions and accessories KBF P series Access port with silicone plugs, 10 mm (0.39), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) Keyboard lock Certificate Light Measurement with ICH - compliant illumination. Radiometric measurements in the visible and UV - A spectral ranges with definition and documentation at 25 positions in 3 measurement levels Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 25 C (77 F) / 60% RH or at specified values Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 C (77 F) / 60% RH or at specified values Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values Temperature safety device, Class 3.3 (DIN 12880) with visual alarm 4-20 ma analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6 - pin DIN socket. utputs are adjusted automatically as the controller is adjusted Zero-voltage relay alarm outputs for temperature (±2 C) and humidity (±5 % RH), accessible via 6 - pin DIN socket, with acoustic signal that can be switched off (maximum power rating 24 V AC/DC, 2.5 A) Switchable waterproof interior socket 230 V AC (max. 500 W), IP 65 protected, with corresponding plug. Max. allowed operating temperature 50 C (122 F) Securing elements for additional fastening of racks (1 set of 4 pieces) Door lock Interior lighting (30 W) External chart recorder for temperature and humidity Data Logger Kit TH 70: For the continuous temperature and humidity recording of -40 C (-40 F) to 70 C (158 F) / 0% to 100 % RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit Data Logger Kit TH 70/70: With two attachable combined sensors. ne for the continuous temperature and humidity recording of -40 C (-40 F) to 70 C (158 F) / 0% to 100 % RH. Second one at the data logger for recording the environmental conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors with 2 m extension cable and 1 fixture for the connection at the BINDER unit Data Logger Kit T 220: For the continuous temperature recording of -90 C (-130 F) to 220 C (428 F). Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable Rack, stainless steel Shelf, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces) max. load 70 kg (154 lbs.) KBF P 240 (E2)