ExPolar Heating System

Similar documents
Fan Heaters Type VLEx

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Gas cylinder scale Model GCS-1

BSK-RPR Fire Damper. Additional operating instructions according to

Technical Data. Dimensions

Snifter ATEX22 VERSION. User Manual. Distributor

BKA-EN Fire Damper. Additional operating instructions according to

INSTRUCTION & SERVICE MANUAL

Flameproof Manual Call Points Series MCP

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. Dimensions

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Illumination unit For sight glass level indicator Model LGI

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTION MANUAL (ATEX / IECEx)

PEPPERL+FUCHS GmbH

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. Dimensions

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Manual Power relay SR853

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Flameproof Manual Call Points Series MCP

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Explosion-proof Immersion Heater Type D-8660

Switches compliant with ATEX directive

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Dräger Polytron 5700 IR Detection of flammable gases and vapours

TYPE APPROVAL CERTIFICATE

Earth-Rite II PLUS Static Earthing System

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Ex LED light fittings

standards: standards:

Hazardous Area Portable Fan Heater The Bulldog

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Finned Tube Air Heaters Type WD/GG (RVS)

DICTATOR Hold-Open Systems for Hazardous Areas

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Dual certification! Air handling units for potentially explosive atmospheres

EU DECLARATION OF CONFORMITY

Centurion Guided Radar HAWK CGR SERIES

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Sintrol Snifter A2 EX. Manual. Version 1.2.3

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

BOBINE ANTIDEFLAGANTI (ATEX) ISTRUZIONI EXPLOSION PROOF COILS (ATEX) - INSTRUCTIONS

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Electrical Installations Design, Selection, Erection and Inspection

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

UL HAZARDOUS LOCATIONS SERVICES

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Instructions for the fan motor control system, SILVER C

Inductive slot sensor

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Explosion Proof Combination Signal db (A) / 5 Joule

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Operating Instructions

Fan speed controller Type Saginomiya XGE

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Installation and Operating Instruction

INSTRUCTION MANUAL (ATEX / IECEx)

COMPACT FLAME CONTROLLER CFC 2000

ATM Lighting sp. z o.o

1592P01. for liquids in piping DN

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Temperature Measurement Transmitters for field mounting

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

Integrated Solutions Low Voltage Systems

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Performance Data. curus Component Recognized; File No. E IP 20

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Dräger Flame 2500 Flame Detection

Datasheet - AZM 161SK-12/12RK-024

Multipoint temperature sensor

Flameproof Manual Call Points

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Transcription:

ExPolar Heating System for use with Max actuators and Cos / Bin / Reg sensors in extreme temperatures to 50 C ATEX certified in acc. with directive 201 / / EU for use in zones 1, 2, 21 and 22 ExPolar -... - MS ExPolar -... - MM ExPolar -... - CBR ExPolar -... - CT Subject to change! Compact. Easy installation. Universal. Cost-effective. Safe. Type suitable for Operating temperature to Supply voltage ExPolar-... - MS...Max... size S 50 C 2 V AC / DC 8 V AC / DC 120 V AC 20 V AC ExPolar-... - MM...Max... size M 50 C 2 V AC / DC 8 V AC / DC 120 V AC 20 V AC ExPolar-... - CBR *...Cos...,...Bin...,...Reg..** 0 C 2 V AC / DC 8 V AC / DC 120 V AC 20 V AC Supply voltage ExPolar-... - CT Types as above in seawater resistant version, terminal boxes with seawater resistant coating (cable glands brass nickel-plated) * Please see information on ordering, commissioning and the operation of the -...-CBR with the Cos, Bin or Reg sensors! ** With aluminium housing. Product images and applications ExPolar-...-MS ExPolar-...-MM ExPolar-...-MS-CT ExPolar-...-MM-CT...Max size S...Max size M ExPolar-...-CBR ExPolar-...-CBR-CT...Cos......Bin......Reg... Fig.: ExCos-D Fig.: + ExPro-C... ExReg-V... Description The ExPolar supplementary heaters ensure that Schischek Max actuators can additionally be used at operating temperatures to 50 C and Cos / Bin / Reg sensors can be operated to 0 C in Ex-area zones 1 and 2 (gases) and 21 and 22 (dust particles). Compliance with the most stringent Ex classes and best quality materials, IP protection, small dimensions and low weight guarantee safe operation even under difficult environmental conditions. The provides for equilibrium between ambient temperature, temperature of the heating element and the ideal operating temperature of Schischek devices. The stainless steel housing ensures energy efficiency, storing heat and reducing heat loss to a minimum. This will lower your operating costs and make sure that equipment continues to function when you need it. The is fully assembled for easy, on-site installation. Highlights For all types of gases, mists, vapours and dusts in zones 1, 2, 21 and 22 Control thermostat monitors ambient temperatures and heat levels Robust heating including reversible temperature shutdown (thermostat) Easy to install and dismantle Stainless steel housing, IP66 protection High quality, UV-resistant insulation Can be retrofitted Electrical supply via prefitted terminal box All add-ons can continue to be used (note operating temperatures! ) 1 / 5

ExPolar heating system 1 Heater with integrated temperature limiters 2 Thermostat Ex-e Terminal box Insulation system with stainless steel enclosure 5 Stainless steel safety tubing (protects supply cables) 1 Heater -...-MS right -...-MM left -...-CBR left 2 Fig.: ExPolar-...-MS on an ExMax... size S 1 5 Information -CBR Ordering Please implicitly specify the type of sensor with which you will be using the heating system. We adapt the housing of the Polar-CBR for the additional output elements of the following sensors. Cos with additional analogue outputs:...cos-p-...-a,...cos-d-a,...cos-a-a Bin with two and more channels:...bin-a2,...bin-a5 Types of Cos, Bin, Reg sensors The Polar-CBR ist suitable for Cos, Bin and Reg sensors with aluminium housing. Please note that equipment with external elements and add-ons that are not heated by the... may only be operated and stored at the corresponding specified ambient temperatures! If you require more information on the operation of equipment with external elements and add-ons, please contact us here at Schischek or get in touch with your local Rotork dealer. Technical data ExPolar...-MS...-MM...-CBR Supply voltage / Frequency 2 V AC /DC, 8 V AC /DC, 120 V AC or 20 V AC 50 /60 Hz with AC Power consumption at 2 V: 2.5 A Protection class III (grounded) at 8 V: 1. A Protection class I (grounded) at 120 V: 0.5 A Protection class I (grounded) at 20 V: 0. A Protection class I (grounded) Output (nominal) 60 W ± 5 % Electrical connection Ex-e terminal box with terminals 0.5... mm², equipotential bonding mm² Cable gland M20 1.5 mm, cable bushing Ø 6...1 mm Material Enclosure Stainless steel 1.0 / UNS -S160 / AISI 16L Heater / Thermostat Aluminium, seawater resistant galvanised, NBR gasket Terminal box Aluminium, powder-coated, EPDM gasket Insulation Armacell / HT Dimensions see section Installation Weigth ~ 1.9 kg ~ 2.2 kg ~ 1.8 kg Ambient temperatures Storage temperature 50...+60 C, ambient temperature during operation 50...+60 C Humidity 0...90 % RH, non condensing Preheat time ~ 1 h Thermostat Heating function ON / OFF: T R = 10 C / 0 C Heizung monitoring: ON / OFF: T1 lim = +60 C / +15 C, T2 lim = +70 C / +5 C Operating mode 100 % ED (= duty cycle) Scope of delivery Heating system with insulation, including heating element, control thermostat, terminal box and securing elements Status on delivery Prefitted terminal box right left left Compliance and certifications ATEX directive 201 / / EU EC type-approved EPS 1 ATEX 1 560 X IECEx certified IECEx EPS 1.0017X Approval for gas II 2 G Ex eb mb IIC T6 Approval for dust II 2 D Ex tb mb IIIC T80 C CE identification CE 0158 EMC directive 201 / 0 / EU Low voltage directive 201 / 5 / EU Enclosure protection IP66 per EN 60529 EAC TC RU C-DE.ГБ08.В.01186 2 / 5

Important information on installation, operation and maintenance All national and international standards, rules and regulations for hazardous Ex-areas must be complied with. For electrical installations design, selection and erection, EN / IEC 60079-1 can be used. For electrical installations inspection and maintenance, EN / IEC 60079-17 can be used. All exposed metal elements, even if these are not live, must be grounded by the protective earthing system irrespective of their rated operational voltage. An at least mm² cable must be used for grounding / earthing (potential bonding); this must be in contact with the operating element. An annual function test is recommended. See section Function of the heating system. The ambient temperatures for devices, including all non-heated elements and add-ons, may not exceed or fall short of specified ranges. If devices, elements and add-ons are operated or stored at ambient temperatures outside specified ranges, these can be damaged and their functioning and safety may be impaired. Devices must be inspected by manufacturers prior to use. Close all openings to ensure enclosure protection. Clean using a moist cloth only. Remove any accumulated dust. Ex area zone 1, 2, 21, 22...Box Safe area Supply voltage terminal box Supply voltage device If the device is installed outdoors, it must be ensured that it is protected against the weather; including direct sunlight (heat and UV!), rain and snow. Electrical connection The supply cable must be securely installed and protected against damage. The operator must ensure that the cable is not exposed to excessive strain. An appropriate fuse must be provided for the power supply. Before opening the terminal box, ensure the device is not live. Connect power cable to terminal box connectors 1 and 2. Connect equipotential bonding cable. Operate the... only in connection with an actuator or sensor. See section Commissioning. Thermostat 1 Heater 2 Function of the heating system Heating The thermostat T R controls the ON / OFF switching of the heater during operation. If the temperature of the actuator or sensor falls below the lower set threshold of the thermostat, the T R is activated by closure of the internal contact. The heater is switched ON. If the temperature of the actuator or sensor reaches the upper set threshold of the thermostat T R, the thermostat is automatically deactivated by opening of the internal contact. The heater is switched OFF. monitoring The heater of the ExPolar is protected against overheating by two integrated temperature limiters T1 lim and T2 lim. 1. If the internal temperature of the heater reaches the upper set threshold of the temperature limiter T1 lim, the heater is switched OFF. Once the heater has cooled to the lower set threshold temperature of temperature limiter T1 lim, the heater is again ready for operation. 2. If the internal temperature of the heater reaches the upper set threshold of the temperature limiter T2 lim, the heater is switched OFF. Once the heater has cooled to the lower set threshold temperature of temperature limiter T2 lim, the heater is again ready for operation. Switching processes controlled by the temperature monitors Contact Preinstalled by manufacturer Customer connections bl br 1 2 1 2 bl br Terminal box bl = blue br = brown Thermostat Heater controller T R limiter T1 lim ~ + ~ limiter T2 2 V AC / DC, 8 V AC / DC lim 120 V AC, 20 V AC 60 50 0 0 20 10 0 10 20 0 0 50 60 70 80 C / 5

Installation -...-M... The terminal box of the -...-M... can be attached to either side of the housing. Heater and thermostat are covered by foil to protect them during transport. Please ensure that this foil is removed carefully prior to operation! The housings of actuators are symmetrical along their axis. You can determine the required direction of rotation during installation. By means of rotation through 180, the direction of rotation can be adjusted to left or right (left / right installation). ExPolar-...-MS with...max actuator size S ExPolar-...-MM with...max actuator size M Upper side Lower side Upper side Lower side The -...-MS can be attached to the actuator prior to or after its mounting on the armature. The extended brackets on the upper side of the. housing are used to fix the actuator to the heating system. 1. Mount the terminal box if necessary to the opposite side of the housing. 2. Determine the direction of rotation required for your application.. Remove the protective foils carefully from the thermal pads of the heater and. Pull the sides of the housing of the slightly apart and place the over the actuator. 5. Close the spring lock of the housing and secure this with a safety splint. You can also fix the to the actuator using securing screws on the lock side. First attach the actuator to your application so that it provides the required direction of rotation. Then fix the -...-MM to the actuator. The upper side of the housing holds the actuator in contact with the heater. 1. Mount the terminal box if necessary to the opposite side of the housing. 2. Determine the direction of rotation required for your application.. Attach the actuator to your application.. Remove the protective foils carefully from the thermal pads of the heater and 5. Pull the sides of the housing of the slightly apart and place the over the actuator. 6. Close the spring locks of the housing and secure these with safety splints. You can also fix the to the actuator using securing screws on the lock side. 27 217 ~ 20 229 ~ 20 11 82 160 16 216 Dimensions in mm Illustrations similar / 5

Installation -...-CBR Upper side (front side) Commissioning Operate the... only in connection with an actuator or sensor. The operating voltage must be applied to the device permanently! Preheat time The power supply to the must be switched on immediately after attachment to the actuator or sensor. Do not switch on the device during the heat-up phase. Fig.: ExCos-D + ExPro-C... 1. Attach the sensor to your application. 2. Remove the protective foils carefully from the thermal pads of the heater and. Pull the sides of the housing of the slightly apart and place the over the sensor.. Close the spring lock of the housing and secure this with a safety splint. ~ 286 17 26 179 12 8 12 189 70 78 80 5,5 Dimensions in mm Troubleshooting / Error messages Problem Possible causes Solution 01 Device does not heat up There is a problem with the power supply. The... must be supplied with power at the specified voltage. The protective foils on heater and / or thermostat have not been removed prior to installation. Thermal pads have become detached from the heater and / or The temperature has exceeded 0 C during transport, storage or operation; the heater has been deactivated. Remove protective foils carefully. The thermal pads must cover the entire surfaces of the heater and Allow thermostat to cool to below 10 C. This will reset the temperature controller. 02 Operation without attached device The internal temperature of the heater has exceeded +60 C during operation; the heater has been deactivated. The internal temperature of the heater has exceeded +70 C during operation; the heater has been deactivated. The heating system overheats and the protective mechanisms deactivate the heating system. Allow thermostat to cool to below +15 C. Allow the heater to cool to below +5 C. Allow the heater to cool to below +5 C. 5 / 5