SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Similar documents
SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

System Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

EVO192 v3.0 Fire and Burglary What s New

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

INSTALLATION MANUAL PC56O. Version 1.OA

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

636 and 646 Keypads. User s Manual

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Digiplex Control Panel (DGP-848) - V4.0

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL

All-In-One Wireless Security System V1.0. Model #: MG-6060

ESPRIT. 616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT

TABLE OF CONTENTS TABLE OF CONTENTS 1

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

GEM-P800 Programming Instructions

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

INSTALLATION MANUAL PC15OO

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

INSTALLATION MANUAL PC25OO

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Light " " = TRBL MODEL 633 KEYPAD TROUBLE DISPLAY. [7] Communicator fail to report. Fire trouble. Tamper or zone wiring fail. Telephone line monitor

Property of Monitronics Inc

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTALLATION MANUAL & PROGRAM RECORD SHEET

Installation Manual Premier 412/816/832. Issue 10

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

4-PGM Expansion Module

System Introduction. 1.1 Specifications

8-zone Expansion Module

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

System Introduction. 1.1 Specifications S E C T I O N 1

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

10-Zone Spectra LED Keypads

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

642 LCD Keypad. User Manual

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Digiplex LED Keypads User s Manual

INSTALLATION MANUAL. PC3OOO Version 7.6W

AXI LED USER MANUAL (REV. 1.0)

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

Property of Monitronics Inc

System Manual W A R N I N G. PC6O1O Software Version 2.1

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Control/Communicator Installation Manual

Programming Worksheets

INSTALLATION MANUAL DV8OOO. Software Version 1.0

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions

CC488. Quick Reference Guide Solution Ultima 880

Version 1.03 January-2002 USER S MANUAL

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

NetworX Series NX-4V2 Control Panel Installation and Startup

Radionics D4112 Program Sheet

LCD and 16-Zone LED Keypads. User s Manual

CC408. Quick Reference Guide Solution 880

Quick Programmer s Manual

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

CA60Plus. Installation manual

MR-2602 Two Zone Fire Alarm Control Panel

Digiplex LED Keypads. User s Manual

Installation Instructions

2000 Series. Program Entry Guide. Control Panels

Training Manual Multi-Language with Wireless

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

NX-4V2 Control Panel Installation Instructions

First Alert 1200C Installer Notes M. Leuck

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

PROGRAMMING WORKSHEETS

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

PowerSeries. PC1616/PC1832/PC1864 version 4.1. Installation Guide

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

Independent Zone Control (I.Z.C.)

CHEAT SHEET: SPECTRA V2.1

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

Transcription:

-961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3 seconds. (2) Connect a jumper between "reset jumper" pins. (5) Remove jumper. (3) Connect AC and/or battery. Factory default installer and master codes will be reinstated. Values entered at addresses 059-243, as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change. PANEL ANSWER OPTIS: ADDRESS 000: (factory default [2ND], [8]) Answering machine override 2nd call time: [2ND] or [1] answering machine override disabled. [2] = 16 sec. [3] = 24 sec. [4] = 32 sec. answer. [5] = 40 sec. [6] = 48 sec. [7] = 56 sec. [8] to [F] = 60 sec. Entering [2ND] [2ND] - Panel will not answer. PANEL IDENTIFIER: 001: 002: PC PASSWORD: 003: 004: Number of rings before answer: Value entered determines number of rings before INSTALLER CODE: (reset code 282828) Full access to programming, except access codes. (addresses 008-058) No access to arming/disarming. Can be used to modify installer code. Use only numeric keys from [1] to [10]. (key [10] = 0) 005: 006: 007: INTELLIZE DELAY: ADDRESS 059: First digit: (factory default [3]) [1] = 16 sec. [5] = 80 sec. [9] = 144 sec. [BYP] = 208 sec. [2] = 32 sec. [6] = 96 sec. [10] = 160 sec. [MEM] = 224 sec. [3] = 48 sec. [7] = 112 sec. [11] = 176 sec. [TRBL] = 240 sec. [4] = 64 sec. [8] = 128 sec. [12] = 192 sec. [2ND] = 256 sec. STREAMLINED SECTI PROGRAMMING Can be used to program s 00 to 34. (addresses 060 to 199) Press [ENTER] installer code [2] [7]. ([2ND] [ENTER] flashes alternately.) Enter a 2-digit number, followed by 8 digits to program that (confirmation beep). Data will be saved automatically and the software advances to the next programming. To exit programming mode press [CLEAR]. TELEPHE AND ACCOUNT NUMBERS: (reset empty) Press [TRBL] at the end of a phone number if less than 16 digits are programmed. If only one central station phone number is used, program the same number for telephone number 1 and 2. [10] = the number "0" [BYP] = switch from pulse to tone while dialing [11] = [MEM] = pause 4 seconds [12] = # [TRBL] = end of number - 1 - HEXA DISPLAY If key is lit = 8 = 4 = 2 = 1 If key is lit = 8 = 4 = 2 = 1 Value of 2 ND digit = 10 ( 8 2 = 10) Value of 1 ST digit = 3 ( 2 1 = 3) VALUE = "3A" No display = SKIP (empty) No light = 0 10 = [0] = [A]

COMPUTER TELEPHE NUMBER: (View at addresses 060 to 067.) 00 / / / / / / / 01 / / / / / / / CENTRAL STATI TELEPHE NUMBER 1: (View at addresses 068 to 075.) 02 / / / / / / / 03 / / / / / / / CENTRAL STATI TELEPHE NUMBER 2: (View at addresses 076 to 083.) 04 / / / / / / / 05 / / / / / / / Press [TRBL] to end phone number if less than 16 digits are programmed. Press [TRBL] to end phone number if less than 16 digits are programmed. Press [TRBL] to end phone number if less than 16 digits are programmed. ACCOUNT "A" AND "B": (View at addresses 084 to 087.) 06 / / / / / / 1 2 3 4 5 6 7 8 A B If only one account number is required, the same number must be entered for both account "A" and "B". REPORTING CODES: (reset code = empty" [2ND] [2ND]) All digits from [1] to [F] are valid. Enter [2ND] (skip) = digit will not be reported. For 3 digit account numbers, enter "skip" ([2ND]) as first digit. If CTACT I.D. format (all codes) is selected, s 07 to 32 are preprogrammed and do not have to be programmed. (Select Contact I.D for both central station numbers at 33 - address 194 - key [10].) - 2 -

REPORTING CODES: (reset code "empty") ALARM CODES ZE 1 TO 10: Data Data 15 Zone 1 Zone 2 Zone 3 (fire) Zone 4 120 121 122 (See add. 220) 123 17 [ 2ND ] [ 2ND] [ 2ND ] [ 2ND ] Zone 9 Zone 10 128 129 130 131 16 Zone 5 Zone 6 Zone 7 Zone 8 124 125 126 127 Sections 18 to 20 are not available. software advances automatically from 17 to 21. RESTORE CODES ZE 1 TO 10: Data Data 21 Zone 1 Zone 2 Zone 3 Zone 4 144 145 146 147 23 [ 2ND ] [ 2ND] [ 2ND ] [ 2ND ] Zone 9 Zone 10 152 153 154 155 22 Zone 5 Zone 6 Zone 7 Zone 8 148 149 150 151 Sections 24 to 26 are not available. software advances automatically from 23 to 27. TROUBLE CODES: Data Data 27 Max. auxiliary current Bell disconnect/ max. bell current Battery disconnected/ low voltage Power failure 168 169 170 171 28 Program change Timer loss Fire loop trouble Test report 172 173 174 175 TROUBLE RESTORE CODES: Data 29 Max. auxiliary current Bell disconnect Battery disconnected/ low voltage Power failure 176 177 178 179 For single digit reporting enter "skip" ([2 ND] ) as first digit. - 3-30 Data Tamper/wiring fault Timer programmed Fire loop trouble TLM trouble restore 180 181 182 183

REPORTING CODES: (continued) (reset code "empty") SPECIAL CODES - FORMATS - PGM: 31 32 Data [ 2ND] Panic 1 Panic 2 Panic 3 Partial arming 184 185 186 187 33 Auto / Espload arm 188 Arm with master code 189 No Movement / 190 late to close Tamper on input 1-4 191 2nd digit: value must be entered i.e. [2 ND] 34 Data [ 2ND] [ 2ND ] [ 2ND] [ 2ND ] [ 2ND ] Disarm with Espload Disarm with master code 1st digit: telephone 1 format 2nd digit: telephone 2 format 1st digit: PGM 1 TYPE 2nd digit: any value must be entered i.e. [2 ND] PGM 1 (1st, 2nd digit) PGM 1 (3rd, 4th digit) 192 193 194 195 196 197 198 199 No movement for specified time/panel not armed at specified hour - see addresses 245, 246, 253. 1st digit of zone tamper is reported with 2nd digit on input 1-4 alarm codes - see addresses 120-123. COMMUNICATOR FORMATS [2 ND ] = ADEMCO slow (1400Hz, 1900Hz, 10bps) [6] [1] [2] [3] [4] [5] = (1400Hz, 1800Hz, 10bps) = SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps) = SESCOA (2300Hz, 1800Hz, 20bps) = RADIICS (40bps with 1400Hz handshake) = RADIICS (40bps with 2300Hz handshake) [7] [8] [9] [10] [ TRBL] = RADIICS with PARITY (1400Hz, 40bps) = RADIICS with PARITY (2300Hz, 40bps) = ADEMCO express = ADEMCO contact ID (selected codes) = ADEMCO contact ID (all codes) = DTMF - no handshake (personal dialing) FEATURE SELECT PROGRAMMING es 200 to 242. ""/"OFF" status of the key lights determines feature selection. In programming mode, enter 3 digit memory address ( 200 to 242). To save entries, press [ ENTER]. To exit programming mode press [ CLEAR]. Reset = "OFF" for addresses 200 to 242 200: CODE PRIORITY SELECT: [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [ BYP ] [ MEM ] [ TRBL ] [2 ND] SYSTEM "A" / STAY 202: SYSTEM "B" / AWAY 204: Codes with bypass access - 4 -

FEATURE SELECT PROGRAMMING (continued) (On/off status of key lights determines which feature is selected.) 206: Telephone line monitor PS1/Keyswitch = regular arm / (A B) PS1/keyswitch arming Call back Auto arm on time Auto arm on no movement Pulse dialing Partitioning Silent zone/panic generates a silent alarm (1:2) PULSE EUROPE Reporting options Bell squawk on arm/disarm Auto zone shut down 208: OFF / Automatic event buffer transmission Panic 1 (keys [1] & [3], PS1) Panic 2 (keys [4] & [6]) Panic 3 (keys [7] & [9]) Panic 1 silent (PS1) [2 ND] [1] [2] [3] [4] Panic 2 silent [5] Panic 3 silent Key [10] regular arm / (A B) Key [11] stay or system A arm 6 digit access codes Tamper Recognition [6] [7] [8] [9] [10] [11] Beep on exit delay Report zone restore on bell cut-off Zones with EOL (1K Ω ) Always report disarm [12] [ BYP] [ MEM] [ TRBL] 210: Exclude power failure from trouble display Zone 4 Auto arm = regular arm / (A B) No tamper bypass Zone doubling (ATZ) Audible trouble warning 20 sec. delay before alarm transmission Keypad 1 zone supervision Keypad 2 zone supervision OFF / [2 ND] 206, Key [2 ND] [1] [1] [2] stay arm / System A [2 ND ] [1] [3] OFF OFF OFF [4] OFF [5] [6] [7] Tone dialing (DTMF) [8] [9] generates only a report [10] (1:1.5) PULSE USA [11] 206, Key [11] [12] [12] TYPE [ BYP] [11] [12] [ MEM] [ TRBL] OFF OFF Reporting disabled Regular reporting OFF / [2 ND] audible audible fire 4 digit on zone closure no EOL only after alarm TELEPHE LINE MITOR OFF OFF TLM disabled TLM generates trouble only generates an alarm if armed silent alarm becomes audible (address 206, key [9] has to be OFF) REPORTING OPTIS Split reporting: Alarms System report Double reporting DIALING SEQUENCE (tel. No.) 1,2,1,2,1,2,1,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm. 2,2,2,2,2,2,2,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm., 2,2,2,2,2,2,2,2, fail to comm. On alarm, all reports are made to Tel. #1 until system is disarmed. (Once disarmed system reports are made to Tel. #2) TAMPER / WIRE FAULT DEFINITIS 208, Key [10] [11] SYSTEM ARMED [10] [11] Alarm as per individual zone definitions Always generate trouble and alarm, audible or silent as per individual zone definitions OFF OFF OFF SYSTEM DISARMED Tamper supervision disabled No alarm, trouble code reported Silent alarm. Trouble and alarm codes reported Audible alarm. Trouble and alarm codes reported Exception: for 24 hour zones the tamper definition will follow the audible/silent alarm definition of the 24 hour zone. Silent zones will generate a silent alarm. [1] disabled (if zone 3 is defined "fire" zone and ATZ is ) [2] stay arm / System A [3] [4] [5] [6] tamper follows zone bypass definition [7] [8] [9] [10] PS1 software version 1.1 [11] Keypad software versions prior to 4.0} Keypad supervision must be OFF [12] PS1 software versions 2.0 onward Keypad software versions 4.0 onward} Keypad supervision must be (See Wiring Diagram) OFF - 5 -

ZE DEFINITI: (reset = " OFF ") SELECT: [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] 212 1 2 3 4 5 6 7 8 9 10 216 1 2 3 4 5 6 7 8 9 10 Intellizone = Silent = 220 24 Hr. /Fire = 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 When zone 3 is defined "24 Hour" it becomes a fire zone 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 228 Follow = 236 Bypass = 240 Stay / system A 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 System B 224 Instant = Delay 2 = Zones that are not selected at addresses 220 to 232 become "Delay 1" zones. 232 242 DECIMAL PROGRAMMING Values entered at addresses "244-255" contain 3 digits between "000" and "255". ([10] = 0) 244: 245: 246: 247: 248: 249: 250: 251: 252: 253: 254: 255: / (days) Auto test report every? days (between "001" and "255") (000=disabled) / (hours) Auto test report / Auto arm time (between "000" and "023") / (minutes) Auto test report / Auto arm time (between "000" and "059") / (seconds) Exit delay (factory default 60 seconds) / (seconds) Entry delay 1 (factory default 45 seconds) / (seconds) Entry delay 2 (factory default 45 seconds) / (minutes) Bell cut-off time / ( x 15 msec.) Zone speed (factory default 600 msec.) / (minutes) Power failure report delay (factory default 30 minutes) (000=disabled) / ( x 15 minutes) Time for "No Movement" Report ( 000=disabled) (factory default 8 hours) / (factory default 5 minutes) PGM timer setting: 001 to 127 for seconds and 129 to 255 for minutes (factory default 5 seconds). Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 128 = 133) / Installer lock ( 147 = locked, 000 = unlocked) (factory default unlocked) DECIMAL VALUE DISPLAY If key is lit = 8 = 4 = 2 = 1 Total value ( 57) ( 8 1 32 16 = 57) If key is lit = 128 = 64 = 32 = 16 No light = 0-6 -

ACCESS PROGRAMMING Programs features quickly, without entering addresses or numbers. To activate key access programming, press [ENTER], followed by installer, master or user code 1. (Code required depends on the feature you wish to access - see below.) Then press the key corresponding to the desired feature. Press [ENTER] or [CLEAR] to exit. key [9] "Auto arming" time program (accessible to master and user 1 only) Key [9] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [MEM] "Panel time" and clear "trouble 8" (all 3 codes) Key [MEM] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [BYP] Test report (all 3 codes) Reporting is at address 206 keys [11], [12]. A value must be entered at address 175, and both telephone and account numbers must be programmed. [TRBL] Call Espload via telephone (all 3 codes) Panel identifier and PC password (addresses 001-004) and computer telephone number (addresses 060-067) must be programmed. [AWAY] Answer Espload (all 3 codes) This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem setup", and panel phone number programmed (works also without ADP-1). PG728 [STAY] Cancel communication attempts Until next reportable event (master code and user 1 can only stop calls from/to Espload) (installer code - all communications) [2],[6] Installer test mode (installer code only) In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long) indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones. [2],[9] Auto arming time program (accessible to installer code only) (Same as key [9] above) When communicating with Espload, it is impossible to enter programming mode. CNECTI DIAGRAMS The system hardware will recognize the following zone conditions: ZE connection without EOL resistor (N.C. contacts) address 208, key [MEM] = "on" key [10] = "off" (reset) key [11] = "off" (reset) N.C. contacts see Figure 1 Keypad zones always use (1K OHM) EOL ZE connection with EOL resistor (N.C. and N.O. contacts) address 208, key [MEM] = "off" (reset) key [10] = "off" (reset) key [11] = "off" (reset) N.C. and/or N.O. contacts, see Figure 2-7 -

ESPRIT 728 CNECTI DIAGRAMS The system hardware will recognize the following conditions: ZE connection with EOL resistor and tamper recognition (N.C. contacts) address 208, key [MEM] = "off" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" Tamper fault transmits separate code, see Figure 3 ADVANCED TECHNOLOGY ZE connection, 2 zones with zone resistors, 1 EOL resistor (1KOHM) tamper (open) recognition, wire fault (short circuit) recognition (N.C. contacts) address 208, key [MEM] = "off" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" address 210, key [8] = "on" Each zone transmits a separate alarm code. Tamper/wire fault transmits a separate alarm code, indicated by fast flashing zone light on keypad and is annunciated in Espload, see figure 4. - 8 -

ESPRIT 728 CNECTI DIAGRAMS ADVANCED TECHNOLOGY ZE connection, 2 zones resistor (without EOL), tamper recognition (N.C. contacts) address 208, key [MEM] = "on" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" address 210, key [8] = "on" Tamper fault transmits separate code Each zone transmits separate alarm code, see Figure 5-9 -

BATT 5AMP GRN RED BRN GRY ESPRIT 728 WIRING DIAGRAM Charging and battery test LED (every 60 seconds) "TLM" LED: Short flash = OK Long flash = Fault OFF = Disabled Constant = On Line Caution: Disconnect battery before replacing fuse. BLACK UL: K12 model T16 V4O ULC: Frost model FTC 1637 - RECHARGEABLE BATTERY UL/ULC 12VDC / 7AH RED TRANSFO 16.5VAC 40VA A.C. POWER BELL OUTPUT will shut down if current exceeds 3A. BELL SIREN UL/ULC Wheelock 46T-12 PS1 software version 1.1 Keypad software versions prior to 4.0 Keypad supervision must be OFF PS1 software versions 2.0 onward Keypad software versions 4.0 onward FIRE RESET } } To program PGM1 to conduct 4 second smoke detector reset when [ CLEAR] and [ ENTER] are pressed simultaneously: 195 = [ BYP] (first digit) 198 = [2 ND] [6] 196 = [5] [10] 254 = [10] [10] [4] - - N.O. contacts Smoke and heat detectors YEL GRN BLK RED 1K Ω EOL To cabinet and grounding rod 220 Zone 3 = Fire zone if zone definition is "24 hour". For zone connections see diagrams below AUX POWER 400mA max. 250mA max. for 24 hr. standby. To connect additional wiring to auxiliary power, use the red () and black (-) keypad connectors. Aux power will shut down if current exceeds 1A. Keypad supervision must be (See 210, key [11] [12]) N.O. Keypad 1or2 1KΩ EOL N.C. Keyswitch can be used in parallel with keypad (or PS1). P R RMED RE DY DOX MAX 5 per system PS1 1KΩ EOL PAD 639/640 MAX 5 per system N.C. Warning: Disconnect telephone line before servicing. Keypad 1or2 PAD 616/626/633 MAX 5 per system SWITCH CNECTI SWITCH RJ31X CA 38A 220Ω N.C. Keypad 1 Keypad 2 KYPD GRN KYPD BLK N.O. 1KΩ EOL N.C. For resistor values, refer to 639/640 installation manuals. FIRE ALARM ZE CNECTIS PGM maximum 50mA GROUND START CIRCUIT PGM AUX Smoke detector - Z3 COM WHT BLK PGM RED AUX Smoke detector - Service Keypad ESPRIT SERIAL OUTPUT AUX - GRN YEL Four pin connector can be used for quick installation of an Esprit keypad. Warning: Improper connection may result in damage to the system. BATT RESET JUMPER SERVICE PAD Z3 COM DIALER AC AC BELL- PGM AUX - GRN YEL 1 COM 2 3 COM 4 R-1 T-1 RING TIP ESPRIT 728 PARADOX SECURITY SYSTEMS PGM OUTPUT RELAY WHT BLK PGM RED AUX MR3-UL MR3-UL Smoke detector power supervision relay, 12VDC 1KΩ EOL Smoke detector must be 4 wire latching - UL Falcon model 5454, ULC BRK 2412. Power supervision relay model MR3-UL. RNG YEL COM BRN N.C. N.O. YEL SECURITY SYSTEMS 780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313 http://www.paradox.ca Paradox Security Systems Graphic Dept PRINTED IN CANADA