BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

Similar documents
Heating system service plans that provide total peace of mind.

ANNUAL HVAC SERVICE AGREEMENT

SERVICE & PAYMENT PLANS. Note from a valued customer LOOK INSIDE FOR OUR NEW BUDGET CHANGES ESTABLISHED 1919

Is a heating protection plan really worth it? Decide for yourself!

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Introducing Hart Air Conditioning

Boiler & Water Heater

Energy Conservation. Chapter 16

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

Peerless Boilers. Series MI. Residential Gas Boilers

Indiana WX Oil Furnace Inspection Guide

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

What is Included with a Seasonal Service?

Columbia Boiler Company

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

High efficiency, cast-iron gas boiler

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

G215 G315 Cast Iron Residential Boilers

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

SECTION HEATING BOILERS

Single stage operation oil burner

Glossary. Carbon Dioxide (CO 2

CHAPTER UTILITY SYSTEMS-HEATING & AIR CONDITIONING. Utility and General System Notes. Heating and Air Conditioning

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Heating Maintenance and Repair

Suggested Specifications Prestige Excellence 110

Intelligent Heating for Your Home

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

In accordance with the Department of Labor and Industry s statute , Subd. 11,

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

DOMESTIC WATER HEATER OIL FIRED

Revitalize Building Mechanical Systems (4619)

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Cast Iron Gas Boilers

DIVISION FINNED WATER-TUBE BOILERS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Cast Iron Oil Boilers

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

Single stage operation oil burner

Warmth, efficiency, and total peace of mind.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Model Universal Oil Primary Control

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

NJR Home Services General Terms and Conditions Basic Comfort Plans

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

TO DO IF YOU SMELL GAS

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

TABLE OF CONTENTS BRADFORD WHITE BOILERS

150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer

PARTS MANUAL Model Numbers:

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

G124X - G234X - G334X Atmospheric Gas Boilers

BuildingName The Description of the Project P DOCUMENTS

MAX. Installation, Operation and Maintenance Instructions. Residential Oil-Fired Boiler

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Better heating. Bigger Savings. SYSTEM

WATER-TUBE POOL HEATERS

Project Name: Location: Engineer: Contractor: I. GENERAL

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

DIVISION FINNED WATER-TUBE WATER HEATERS

OIL-FIRED CENTRAL FURNACE

Solutions to Pollution

New York State Division of Housing and Community Renewal

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Product Family Overview

Interrupted Ignition Series Oil Primary Control

DIVISION FINNED WATER-TUBE BOILERS

FUEL-FIRED VERTICAL TUBELESS BOILERS

Technician's Pricing Guide NORTH RESIDENTIAL. Collier Consulting Group

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

WATER-TUBE POOL HEATERS

Series 300 VTB. Installation Instructions

WHAT TO DO IF YOU SMELL GAS

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Audit Date: Auditor: Sarah Hayden Client Name: College of St Benedict Audit Phone:

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

OPERATING AND MAINTENANCE MANUAL

SERIES 19A. mith PRESSURIZED WET BASE

Transcription:

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home.

WE PROMISE SERVICE PLANS THAT PROVIDE PEACE OF MIND. AND THAT S EXACTLY WHAT WE DELIVER. Oil Heating System Service Plans Just like changing the oil in your car, your oil heating system should be tuned up annually to help reduce the amount of fuel that your system uses, which is good for your energy savings and the environment. Each of our service plans provide you with: There s no better way to heat your home and to provide your family with year-round hot water than with oil heat. And there s no better company you can turn to for all your heating needs than Hoffman Energy. As a local business, we ve been part of the community since 1897, providing heating and home services to customers in Connecticut and New York in ways that other suppliers cannot. We offer the most comprehensive package of service and support in the industry. We can anticipate peak periods of demand and provide trouble-free home comfort. As a full-service company, we re there when you need us most day or night, year-round. That s why we say, Nobody serves you better. Quality repairs by experienced technicians Expert customer service reps to take your calls 24/7 Convenient service hours Annual tune-ups to help you save money 15% discount on non-covered repairs

V The Value Plan Extensive coverage for the budget-minded homeowner. P The Premier Plan Comprehensive coverage for peace of mind. The Parts Fuel & Combustion 1 Air Tube 1 Burner Coupling 2 Burner Fan 2 Burner Motor 3 Cad Cell Eye 3 Cad Cell Relay 4 Combustion Chamber (wet-based, max 2.5 GPH) 5 Delayed Oil Valve 6 Draft Regulator (up to 9" diameter) 1 Electrodes 7 Emergency Switch 1 End Cone 8 Firomatic Valve 9 Fuel Pump 9 Fuel Pump Gasket 9 Fuel Pump Strainer 10 Flue Pipe (max 9" diameter) 11 Igniters 11 Ignition Transformer 1 Nozzle 1 Nozzle Adapter 1 Nozzle Line Oil Check Valve V P V P V P 12 Oil Filter Cartridge 12 Oil Filter Complete Oil Safety Valve 1 Porcelains Primary Control 14 Thermostat Standard 15 Thermostat Clock Type ($50 credit) Warm Air 16 Blower Complete (up to 3/4 HP) 17 Blower Motor (up to 3/4 HP) 18 Fan & Limit Control 18 Fan Control Hot Water and Steam Components Air Scoop 19 Aquastat (auto type only) 19 Aquastat Well Automatic Air Vent (boiler room only) Balancing Valve 20 Boiler Drain Valve Boiler Relief Valve (up to 1" diameter) 21 Circulator Complete (kitchen zone up to 1/12 HP) 21 Circulator Components (kitchen zone up to 1/12 HP) Circulator Relay (kitchen zone up to 1/12 HP) Zone Valve Complete (kitchen zone up to 1" diam.) Domestic Relief Valve Dual Valve Expansion Tank (max 24 gallons) Expansion Tank Valve Extrol Tank (max # 60) Feed Valve Feed Valve Washer Flow Check Valve 22 Gauge Glass & Washers Limit Control Low Voltage Transformer Manual Feed Valve Pop Safety Valve (up to 1" diameter) Pressure Gauge Pressuretrol (auto type only) 13 Pressure/Temperature Gauge Zone Valve Component (kitchen zone up to 1" diam.)

How your oil-fired heating system works. Heat distribution Oil-fired heating systems distribute heat in one of three ways: warm air through vents, hot water through baseboards, or steam through radiators. Your thermostat senses that room temperature has fallen below your thermostat setting and sends a signal to your heating system to provide heat for your home. When your oil burner is engaged, heating oil travels from the tank to the burner by way of a pump where it becomes a fine mist mixed with air. The fuel/air mixture is then injected into the burner where it is ignited in the combustion chamber. Heating system types Depending on the type of system you have, waterbased or warm air, the system works differently to disperse heat throughout your home. There are two main types of water-based systems: hot water systems and steam systems. Water is heated in either a cast iron or steel boiler before it is dispersed throughout your home. In a hot water system, the heated water is circulated through radiators or baseboards. Typical Hydronic System Hot water or steam Flue Pipe Thermostat Radiator Hot Water Oil Tank Typical Warm Air System Return Duct Thermostat Baseboard In a steam system, water turns to steam and rises through pipes to the radiators. In a warm air system, your furnace heats air. A blower then sends the heated air up through ducts and out of vents in your floors or walls. The air gets drawn back to the furnace through a return duct, and the cycle repeats. Finally, emissions from the combustion of fuel and air exit the system through a flue pipe that runs out of your home through the chimney. Flue Pipe Vent Feed Duct Oil Tank

Still need more coverage? We have other enhancements and agreements that are available at an additional cost to your existing plan and these are priced separately. They allow you to extend your coverage with more comprehensive protection and help you prepare for unexpected repair costs by allowing you to customize your protection to suit your needs. You must currently have a Hoffman Energy Value or Premier Service Plan to add any enhancement coverage. Optional enhancements Direct and Indirect Water Heater Repair and Part Replacement* This enhancement covers repairs and replacement of the parts listed below: Air tube Aquastat (auto type only) Burner coupling Burner fan Burner motor Cad cell complete Circulator (bronze type, up to 1/16 HP) Delayed oil valve Draft regulator (up to 9" diameter) Drain valve Drip tube Electrodes Electrode wire & clips Emergency switch End cone Firomatic valve Flue pipe (up to 9" diameter) Fuel pump Fuel pump gasket Fuel pump strainer Igniters Ignition transformer Nozzle Nozzle adapter Nozzle line Oil check valve Oil filter cartridge Oil filter complete Oil safety valve Porcelains Preference relay Primary control Relief valve Additional agreements CARE Environmental Protection Fortunately, oil leaks don t happen too often. But when they do, they can damage the environment and cost thousands of dollars to clean up. And worse, most homeowners insurance doesn t cover oil leaks. The CARE program protects your investment in your home by providing clean-up coverage in case your tank, connected piping or oil lines leak. The CARE program is available for above-ground fuel tanks and provides: Up to $100,000 for clean-up*** Clean-up of releases from entire fuel oil system, including piping and lines Limited cost share Transferable if you sell your home Experienced professionals to handle the work A separate program is available for underground fuel oil storage tanks. Underground oil tanks require a one-time testing fee in addition to the cost of the program. ***Does not include tank replacement. *Covers residential, oil-fired water heaters up to a maximum firing rate of 1.25 gallons per hour. Excludes coverage of the water heater tank, recirculation lines and components, and anode rods. Repair and/or replacement must be performed by Hoffman Energy. Optional Zone Coverage** This enhancement covers repair and replacement of the parts listed below: Automatic air vents (boiler room only) Circulator complete (up to 1/12 HP) Circulator coupling (up to 1/12 HP) Circulator flanges and gaskets (up to 1-1/2" diameter) Circulator impeller (up to 1/12 HP) Circulator motor (up to 1/12 HP) Circulator mounts (up to 1/12 HP) Circulator relay Flow check valve (up to 1-1/2" diam.) Isolation valves (up to 1-1/2" diam.) Thermostat (standard) Thermostat (clock type $50 credit) Zone valve (up to 1" diameter) Zone valve motor (up to 1" diameter) **Not available on steam systems and excludes air handlers. Repair and/or replacement must be performed by Hoffman Energy.

Nobody serves you better. 1.800.637.2239 hoffmanfuel.com The service plans described in this brochure are subject to Hoffman Energy s terms and conditions of service which are provided and incorporated by reference into this brochure. DCP-HOD.366 or HOD.99. CT. Lic. 390819-S1, #P1-0286802. 2018 Hoffman Energy. CH_18027