Temporary wireless battery operated fire system from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: 0845 884 7000 Petersfield Business Park f: 0845 884 6000 Bedford Road Petersfield Hampshire e: sales@channelsafety.co.uk GU32 3QA w: www.channelsafety.co.uk INSTRUCTI MANUAL - Issue 1-02/2014 1 INSTRUCTI MANUAL
INTERFACE PRESENTATI & FEATURES The radio link alarm interface module allows to transmit a fire alarm from radio linked alarm devices (MCP, stand alone alarm and smoke detector) to an anti-intrusion control panel, a remote transmitter, a sounder, a beacon, etc. Operating principle When a radio linked device (MCP, stand alone alarm or smoke detector) is in alarm, it sends the information to the radio link alarm interface module which changes its state (change-over contact), thus transmitting the alarm information to the intrusion control panel (or else). lid fastening screws Alarm LED Radio LED switch Features lid BR1 BR2 BR3 - + - + C R T External supply : 12 V (supplied by a control panel for example) Standby consumption: 0.1 ma @ 12 V Alarm consumption : 25 ma @ 12 V Indoor environment Operating temperature : -10 C to +50 C Housing Dimensions : H 83 mm x l 83 mm x D 46 mm Hole pitch : 40 mm Colour : red Interconnection Capacity Number of smoke detectors and stand alone alarm per radio link alarm Interface module : non restrictive Up to 10 radio link alarm interface module within a system Radio range in free-field condition : 100 meters radio link interface module fastening screws radio electronic board housing white plastic cap cable gland Radio relay card Wiring BR1 BR2 BR3 - + - + C R T Supply 12Vdc Local Alarm input (contact No) Relay contact INSTRUCTI MANUAL - Issue 1-02/2014 2
CNECTI Follow the steps to connect the radio link interface module to a smoke detector or a stand alone alarm STEPS ACTIS SOUND SIGNALS DESCRIPTIS 1 Power up the radio link interface module (slave). 2 Press for 5 seconds the configuration key on the slave element. 3 beeps The configuration is taken into account. The slave element sends a message to be associated to the existing group. 3 Press the test key of a smoke detector or the validation key of a stand alone alarm. Long beep The radio link interface module is now connected to the system. It sets to setting optimization mode. 4 Move away to the place chosen for the radio link interface module and check the radio link quality. > See the table «checking the radio link quality» below. 5 Mount the slave element on the chosen location. 1 to 5 beeps sequences in steps of few seconds. Checking the radio link quality. 6 Press the configuration key of the slave element. 4 beeps Exit configuration mode. 4 beeps Exit setting optimization mode. The system is now operational. Cancel the connection with a smoke detector or a stand alone alarm While in step 2, press for 10 seconds the configuration key (instead of 5 seconds) (see step 2 above). 4 long beeps will be heard indicating that the connection is cancelled. Checking radio link quality When the slave element is in setting optimization mode, 1 to 5 beeps can be heard in steps of few seconds. Check the radio link quality according to the number of beeps. Number of beeps 1 2 3 4 5 Radio link quality NOT RECOMMENDED Risk of system failure Recommended installation INSTRUCTI MANUAL - Issue 1-02/2014 3
SWITCH CFIGURATI Default setting: 1 2 3 4 Switch 1 1 Auxiliary input closing 1 Auxiliary input opening Switch 2 2 2 «Type 4» alarm > sound on the stand alone alarms, no alarm on the smoke detector «smoke detector» alarm > intermittent sound on the stand alone alarms and activated smoke detector Switch 3 3 No activation of the alarm relay when receiving a smoke detector alarm. 3 Activation of the alarm relay when receveing smoke detector alarm messages. Switch 4 4 4 No activation of the alarm relay when receiving a stand alone or manual call point alarm. Activation of the alarm relay when receveing stand alone alarm or manual call point alarm messages. INSTRUCTI MANUAL - Issue 1-02/2014 4
USE Test Regularly perform this test on all the connected smoke detectors. This test can t be carried out on the connected manual call points or stand alone alarms. 1. One smoke detector test The one smoke detector TEST function allows to check at any time the radio link quality between one smoke detector and the radio link alarm interface module. Press the TEST key of a connected smoke detector. The TEST signal is sent to the interface module (for 5 minutes). Test Signal Note For 1 minute Beeps + red blinking indicator The number of beeps and blinking correspond to the radio link quality of the last received signal. Then for 4 minutes Red blinking indicator To stop the TEST signal before the end of the test, press the interface module key. 2. All smoke detectors test The all smoke detectors TEST function allows to check at any time the radio link quality between all the connected smoke detectors and the radio link alarm interface module. Press the interface module key (short press). Test is activated for all the connected smoke detectors. A sound signal indicates that the radio signal is being sent. Note : this function is inhibited in case of alarm. Alarm signal The interface module receives alarm information from connected smoke detectors, manual call points and stand alone alarms. When an alarm information is sent, the interface module red indicator is steady on. 20 seconds after the original alarm has disappeared, the interface module is automatically reset. INSTRUCTI MANUAL - Issue 1-02/2014 5
VISUAL AND SOUND IDENTIFICATI Visual identification Meaning Note Blue indicator radio activity - Red indicator steady on alarm signal received - blinking test signal received the number of blinking correspond to the radio link quality of the last received signal. Sound identification Meaning Note 1 to 5 beeps sequences for 1 minute test signal received the number of beeps correspond to the radio link quality of the last received signal Sequences from 1 to 5 beeps every few seconds connection in process INSTRUCTI MANUAL - Issue 1-02/2014 6
ENVIRMENTAL PROTECTI 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted munici pal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. This product complies to the RoHS 202/95/EC relating to the restriction of the use of certain hazardous substances in electrical and electronical equipment since July 1st, 2006 INSTRUCTI MANUAL - Issue 1-02/2014 7