Temporary wireless battery operated fire system from Channel Safety Systems

Similar documents
setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Temporary wireless battery operated fire system from Channel Safety Systems

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

SECURIT 703 USER MANUAL

Radio fire warning panel SRC 3000

External Wireless Sounder

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

9000P Wireless Alarm Owner s Manual

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

HILLS Series LED Code Pad User Manual

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

Analogue addressable devices

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

Fire Alarm Control Panel. System Maintenance and Log Book

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

ZSC100 Gas Detection and Alarm System Controller

New Silent Alert Fire Safe System

9 100% Recycled Paper

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

External Wireless Sounder

Operating Instructions Version 1.2

5000 INSTALLATION GUIDE

Installation and user manual for the BiWire / Conventional Repeater Panel

Silent Alert Fire Safe System

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Premium 8 Zone Wireless Alarm Kit

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Total Connect Box. User manual

Datasheet CALYPSO II R. Interlinkable smoke alarm device

Control Panel User Guide

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Q3200 Smart Home Alarm. Kit Content and Installation Guide

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

636 and 646 Keypads. User s Manual

EXTINGUISHING AGENT RELEASE MODULE

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

RadioLINK Alarm Base. Instructions. Model: Ei168RC

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Conventional Fire Alarm System 2014 V1.2

Wireless Keypads LKP(E)S8M Series

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

SMOKE User Manual. NE v2.0

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

Alarm Controller Fire and CO

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Model: Ei450. Instruction Manual

QUICK CONSUMER REFERENCE GUIDE

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

NetworX NX-8V2. LED Keypad User Manual

Control Panel User Guide (TO BE RETAINED BY THE USER)

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Watchguard WGAP864 User Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

ZITON RADIO LOOP MODULE

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

NETWORX TM. User manual NX-4

Zigbee Smoke Sensor PSG03

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Installation and ZONES: Operation Manual. Model: ON STI-34108

WIRELESS COLOR WEATHER STATION

Wireless Keypad GKP-S8M

Deaf & Hearing Impaired RadioLINK Alarm System

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

QA16 Addressable System

Fire / CO Alarm Interface

CW9000 Wireless Fire System. Installation Manual

Tomorrow s technology for today s security needs.

Wireless Weather Station. Table of Contents

G4S SMARTalarm User Guide

Installer Guide smart connect

status AW1 Plus WiFi Alarm System User Manual

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

R9968 ROBERTS. Analogue World Radio. Sound for Generations. Please read this manual before use

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Transcription:

Temporary wireless battery operated fire system from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: 0845 884 7000 Petersfield Business Park f: 0845 884 6000 Bedford Road Petersfield Hampshire e: sales@channelsafety.co.uk GU32 3QA w: www.channelsafety.co.uk INSTRUCTION MANUAL - Issue 1-02/2014 1 INSTRUCTION MANUAL

INTERFACE PRESENTATION & FEATURES The Rapidfire Temporary wireless battery operated fire system can combine up to 10 units, consisting of 1 master unit and 9 other break glass or smoke detector units. The Rapidfire system is powered by batteries and requires no mains voltage supply. Master unit Manual call point mounted in a white ABS box with integral sounder. Master unit power supply Radio module: 3Vcc lithium 1300mAh battery. Break glass and sounder: 6 LR 61 Alkaline 9 volts battery Dimensions: 242 mm(h) x 126 mm(w) x 75 mm(d) Weight: 0.8Kg Average power consumption in standby: 2μA Sounder Loudspeaker: 90 decibels @ 2 meters Visual alarm: Operates in conjunction with the sounder) 0,6 Hertz (1 flash every 1.5 seconds) Manual call point (MCP) Manual call point power supply Radio module:3vcc lithium 1300mAh battery Average power consumption in standby: 0.60μA Maximum range between the MCP and the master unit is 100 meters in free air condition. This distance will be reduced within buildings. It is essential that full testing is carried out. Battery life According to the number of units linked to the master unit, the life of the batteries will be:- NUMBER OF UNITS 1 2 3 4 5 6 7 8 9 EXPECTED BATTERY LIFE (IN YEARS) 12 10 9 8 7 6 6 5 5 Test and operation key The key has three functions: 1. Testing 2. Resetting the MCP 3. Opening the master unit INSTRUCTION MANUAL - Issue 1-02/2014 2

INTERFACE PRESENTATION & FEATURES CONTINUED... Opening and closing master unit 1. To open the master unit Use the black key fixed on the top of the box 2. Press the two slots on the underside the box with the two pins of the key 3. The front face can now be removed by hinging upwards 4. To close the box, engage the top front face in the slots on top of the box. Clip the lower part of the front face to the back box Master Unit - Mounting Fix the box at maximum 1.30 meters high using the integrated spirit level. 1. Open the front face of the box 2. Mark the location of the holes 3. Drill the holes in the wall 4. Place the base of the box on the wall (using the integrated spirit level) 5. Insert & tighten the four screws. 6. Replace the facia Fix the manual call point between 1.2 & 1.6m high. Follow the same procedure as the master unit mounting. INSTRUCTION MANUAL - Issue 1-02/2014 3

BATTERIES Batteries insertion CAUTION: please ensure the batteries are correctly installed. Observe the correct battery polarity. The PCB may be damaged if this is not carried out. Master unit - Connect the 9 volts 6 LR 61 Alcaline battery to the corresponding terminals in the box, to the right of the loudspeaker. Insert the lithium 3Vcc battery in to the radio module behind the MCP (lowest part of the box). MCP - Insert the lithium 3Vcc battery in the base of the box. INSTRUCTION MANUAL - Issue 1-02/2014 4

CONNECTION Link manual call points & slave MCP/Sounder units to the master unit Each unit should be linked to the master unit one at a time. 1. To link the MCP to the master unit, open the MCP or slave MCP/Sounder unit. Open the Master unit 2. Place the unit you wish to link next to the master unit 3. Press the CONFIGURATION button in the MCP or slave unit for 5 seconds (the unit will bleep to indicate each second) 4. Once the unit sent the configuration signal the buzzer will pulse and the amber LED will illuminate 5. Release the CONFIGURATION button 6. Press the VALIDATION button in the master unit until you hear a long bleep 7. The MCP/Slave unit is now linked to the master unit and will now enter the Signal strength mode 8. Take the MCP or slave unit to the required location and ensure the signal strength is adequate. The MCP/Slave unit will regularly bleep up to 5 times to indicate signal strength 9. If the signal strength is adequate, install the unit. (or relocate & check signal strength) 10. Press the VALIDATION button in the MCP/Slave unit The unit is now operational To add another MCP or master unit (slave) to the existing group: repeat the steps 1 to 10. Maximum number of MCP, smoke detectors or slave units is 9 per master unit. INSTRUCTION MANUAL - Issue 1-02/2014 5

CONNECTION CONTINUED... Link Smoke Detector to the Master unit. Each unit should be linked to the master unit one at a time. 1. To link the smoke detector to the master unit, open the Master unit 2. Place the unit you wish to link next to the master unit 3. Remove the battery isolation tag (unit bleeps rapidly) 4. Within 20 seconds press the clear button/indicator on the side of the detector. Unit bleeps. Release button. LED flashes blue 5. Press the VALIDATION button in the master unit until you hear a long bleep 6. The detector is now linked to the master unit and will now enter the Signal strength mode 7. Take the detector to the required location and ensure the signal strength is adequate. The detector unit will regularly bleep up to 5 times to indicate signal strength (see page 5 for signal strength). If the signal strength is adequate press the clear button on the side of the detector. Detector will bleep. 8. If the signal strength is adequate, install the unit. (or relocate & check signal strength) Checking radio signal strength When the MCP, smoke detector or slave unit is in signal strength mode it bleeps from 1 to 5 times within ba few seconds. These bleeps indicate the quality of the radio reception (from very poor to very good). Ensure the location for each device gives at least 3 bleeps. If it does not then another location should be chosen If the radio reception is poor, ensure that there are no obstructions in the radio path. NUMBER OF BLEEPS 1 2 3 4 5 SIGNAL STRENGTH Very Poor + Poor ++ Signal Strength not adequate Medium +++ Good ++++ Adequate Signal Strength Very Good +++++ Setting up of the MCP, detectors and slave units Place the unit at the required location. Place the unit more than one meter from: Electrical switchboard or cables. Any metal object, Radio disturbance sources. Avoid placing the unit on/near metal objects, electrical equipment or cabling. INSTRUCTION MANUAL - Issue 1-02/2014 6

DIAGNOSTICS Diagnostic mode The diagnostic mode allow you to check the quality of the signal strength between the master unit (master) and the MCP and slave units. To activate the diagnostic mode, press the transparent switch on the master unit for at least 5 seconds. The diagnostic mode is activated when The green LED of the master unit blinks Every unit linked to the master unit emits a bleeping sequence which corresponds to the quality of the signal strength. To exit the diagnostic mode, press the transparent switch on the master unit (automatic exit after 15 minutes). Faults FAULTY UNIT INDICATED BY... AND BY... Master Unit Slave Unit MCP Flashing orange LED on the master unit One or several bleeps (every 30 seconds) depending on the fault. Identify the fault The master unit sounds 1 to 4 bleeps depending on the fault: NUMBER OF BLEEPS FAULTY UNIT FAULT 1 Master Unit Battery 2 MCP integrated in the master unit Battery 3 MCP or slave unit Battery 4 At least 1 MCP or slave unit Communication fault The MCP or slave unit which has a fault is indicated by: 1 bleep every 30 seconds: battery fault 2 bleeps every 30 seconds: communication fault (no signal received from the master unit master in 24 hours) Repair the fault by replacing the battery Replace the defective battery by: Lithium 3Vcc CR 17 345 battery for the MCP (including the one installed in the master unit. 9V 6 LR 61 battery for the master unit. INSTRUCTION MANUAL - Issue 1-02/2014 7

CONNECTION CONTINUED... Communication Go on to the diagnostic mode to check the quality of the signal strength. Relocate if required. Clear configuration Should you wish to clear the configuration data to allow the units to be reused or relocated: Master unit, MCP or Slave unit Open the MCP/Slave unit Press & hold the CONFIG button, the unit will bleep. Press & hold the VALID button. The unit will give a series of long bleeps followed by a series of short bleeps followed by one long bleep. The unit is now decommissioned. Smoke Detector The smoke detectors do not need to be de programmed, simply de powering them using the battery isolate tag and then logging them on to a new system carries out this function. Operation Manual Alarm The general alarm is activated when one of the MCP s is activated. Resetting Insert the black key in the MCP and turn 1/4 counter-clockwise to restore the normal position. Testing Insert the key in the hole on the front face of the MCP. The MCP activates the alarm mode. Reset the MCP by turning 1/4 counter-clockwise Do not turn the key more than 1/4. Remove the key by turning clockwise. Manual call point Resetting Once one of the MCP has been activated, reset it with the black key, turn the key 1/4 clockwise (remove key by turning clockwise) The alarm will silence in about 15 seconds. Internal LEDs Amber LED: sends the alarm signal to the combined master unit Red LED: the alarm is accepted by the master unit Maintenance We advise you to keep the equipment clean and to ensure that the installation is in a dry and ventilated area. 9V 6 LR 61 battery test The system will automatically test the batteries every 12 hours. Manual test Press the transparent switch on the master unit The indicators illuminate and will indicate the battery voltage The master unit emits a beep at the same time as the indicators turns on to check that the loudspeaker works Indication The colour mode indicates the battery voltage: COLOUR VOLTAGE Green Orange Red 9-8 V 8-7.5 V 7.5-7 V As a precautionary measure, change the battery when the indicator is red. Always replace the batteries with the same type as originally supplied. INSTRUCTION MANUAL - Issue 1-02/2014 8

INSTRUCTION MANUAL - Issue 1-02/2014 9