setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Similar documents
Temporary wireless battery operated fire system from Channel Safety Systems

Temporary wireless battery operated fire system from Channel Safety Systems

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

External Wireless Sounder

SECURIT 703 USER MANUAL

Datasheet CALYPSO II R. Interlinkable smoke alarm device

SMOKE User Manual. NE v2.0

CPVan Home Alarm Starter Kit

ZITON RADIO LOOP MODULE

Silent Alert Fire Safe System

External Wireless Sounder

1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

9000P Wireless Alarm Owner s Manual

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Operation - the PIR internal movement sensor. Operation - the tilt sensor. Operation - awning light. Operation - marker / tail lights

Consultant Specification AGILE Wireless Fire Detection System

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Control Panel User Guide

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

New Silent Alert Fire Safe System

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Watchguard WGAP864 User Manual

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

5 Sounds and Indications

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

status AW1 Plus WiFi Alarm System User Manual

Operating Instructions Version 1.2

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Intruder alarm system Operating Instructions

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

ZSC100 Gas Detection and Alarm System Controller

CR2003 ROBERTS. 3 band Auto set PLL Synthesised Clock Radio. Sound for Generations. Please read this manual before use

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Radio fire warning panel SRC 3000

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

5000 INSTALLATION GUIDE

Mobeye CM2410 GSM fire alarm communicator

ThermoPlus AS2-RF & ASR-RF Installation Instructions

R9968 ROBERTS. Analogue World Radio. Sound for Generations. Please read this manual before use

Control Panel User Guide (TO BE RETAINED BY THE USER)

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

HILLS Series LED Code Pad User Manual

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Smoke Detector and Siren. Manual

Fire / CO Alarm Interface

Alarm Controller Fire and CO

irad Wireless Controller

RF Modules for Battery Powered Smoke & Heat Alarms Ei600 Series

Sidekick II Receiver Model # SK2-SS 418MHz

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

Total Connect Box. User manual

evohome Sundial pack Thermostat

RadioLINK Alarm Base. Instructions. Model: Ei168RC

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Wireless Keypads LKP(E)S8M Series

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

C-Stat 17-ZW User Instructions

1126 Series Ceiling Mount PIR Motion Detector

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES


3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

>WIRELESS> ALARM SYSTEM CR200

Smoke Vent Control Panel PCB4 V4 Installation Manual

Wireless Alarm system s manual

PTE0705 Electric Fence Monitor

U ser's Guide PC6010

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

EXTINGUISHING AGENT RELEASE MODULE

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers


PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Home Doorway Alert Kit

CR9986. Please read this manual before use. Dual Alarm CD Clock Radio 5/19/2005, 8:28 AM. Sound for Generations ROBERTS. CR9986 Rev 1.

Contents. Glossary

Premium 8 Zone Wireless Alarm Kit

Installation and user manual for the BiWire / Conventional Repeater Panel

QUICK CONSUMER REFERENCE GUIDE

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Installation, Operating and Maintenance Manual

User s guide Personal radio trigger Erik 9100

Transcription:

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS 61 936 NFS 32001 EN 54-11

Megalarm wireless system General points The Megalarm mini wireless fire alarm system is designed for small offices, shops, workshops and temporary buildings. It can combine up to 10 units consisting of 1 master unit and 9 slave units, either manual call points or smoke detectors. The system is powered by batteries and requires no mains voltage supply. The master P300W can be combined with several C300W radio manual call points (MCP) and radio smoke detectors D300W the instructions in this manual will enable you to commission all elements together, which when activated will register an alarm sound from the P300W master and D300W detector. Also you will find instructions of how to attach a radio link alarm interface module to connect to an existing fire alarm system. Instructions for decommissioning can be found on the last page should you encounter any difficulties. Technical Data P300W master unit Power Lithium 3V battery capacity: 1300mAh, IEC standard: CR17345 for the radio module & 6LR 61 Alkaline 9 volts battery for sounder/beacon Installation Method Surface mounted Sounder Integral 90db within 2 meters Strobe Lights Integral high power LEDs Dimensions 126(W)x242(H)x75(D)mm Colour White ABS Manual Call Point Integral/wireless complete with 3V lithium battery C300W manual call point Power Integral lithium 3V battery, capacity: 1400mAh, IEC standard: CR17345 Range Maximum range between manual call point and base = 100m in open area conditions Installation Mounting Surface mounted Resetting Key Included D300W wireless smoke detector Power Lithium sealed in battery (non-replaceable) Sounder Integral 85db Test Button Integral Operating Temperature 0 ºC - 55 ºC Radio Linking Frequency 868 Mhz Range 100m range in open area conditions Wireless interface Power 12V via fire alarm panel Operating Temperature 0 ºC - 55 ºC Dimensions 83(W)x83(H)x46(D)mm Interconnection Capacity Smoke detectors unlimited Range 100m range in open area conditions Testing Battery to be tested annually

setting up your wireless system step 1 your master unit Commissioning your system requires that you make a P300W unit the master and all other components slaves (C300W or D300W) stage one, opening and closing your master P300W unit Open your master unit using the black key supplied. Using the 2 pins of the key press in the 2 slots on the underside of the unit. To close the unit simply click the lid back into place and return key to the holding slot on top of the unit stage two, mounting your P300W to the wall Fix the box at maximum 1.30 meters high using the integrated spirit level. Dimensions can be found on the drawing below

stage three, activating the batteries Caution: Please ensure the batteries are correctly installed, observe the correct polarity as the PCB may be damaged if this is not carried out. 1. Connect the 9 volts 6 LR 61 Alcaline battery to the corresponding terminals in the box, on the right of the loudspeaker. 2. remove the paper insulater from the lithium 3Vcc battery in the part reserved for the MCP ( lowest part of the box). step 2 adding a manual call point C300W into the system stage one, opening your manual call point (MCP) Simply unscrew the holding screw in the front of the box, then lift off the front face. stage two, mounting the MCP Fix the box at maximum 1.30 meters high. Dimensions can be found on the drawing below Note: Avoid placing the units on or near metal objects, electrical equipment or cabling. Note: Do not install the unit nearer than 1 meter to electrical switchboard or cabling, metal objects or radio disturbance sources.

stage three, activating the batteries Caution: Please ensure the batteries are correctly installed, observe the correct polarity as the PCB may be damaged if this is not carried out. Remove the paper insulator from the lithium 3Vcc battery. stage four, configuring your MCP into the system Note: Do one configuration at a time 1. Open the master unit and the first MCP. 2. Place the MCP next to the master unit. 3. Press the CONFIG button in the MCP for 5 seconds, the unit will beep to indicate each second. 4. Once the unit has sent the configuration signal the buzzer will pulse and the amber LED will illuminate. Release the CONFIG button. The MCP now sends a request to be combined to an existing group. This is indicated by 1 beep every 3 seconds 5. Press the VALID button in the master until you hear a long beep 6. The MCP is now linked to the master unit and will now enter the signal strength mode. 7. Take the MCP to the preferred location and ensure the signal strength is adequate, the unit will beep indicating the signal strength. You should try to achieve at least a signal strength of 3 Number of Beeps 1 2 3 4 5 Signal Strength Very weak Weak Medium Good Very good

8. Once positioned in its final setting press the VALID key on the MCP it will beep 4 times to enter normal service. 9. the master will also beep 4 times as it enters normal service. The system is now operational. Note: to add further call points or stand alone P300W units (as a slave to the master) repeat previous steps 1 to 9 Note: maximum extra components as slaves is 9 step 3 adding a D300W radio smoke detector Note: Do one configuration at a time 1. To link the smoke detector to the master, open the master P300W box. 2. Place the unit you wish to link next to the master unit and remove the battery isolation tag from the underside of the smoke detector. Put the key away in the location space provided (see below on the right). 3. Within 20 seconds of removing the tag, press the clear button on the side of the smoke detector and the unit will beep, release the button and the LED will flash Blue. 4. Press the VALID button in the master unit until you hear a long beep. 5. The smoke detector is now linked to the master unit and will now enter the signal strength mode. 6. Take the detector to the required location for installation, the detector will regularly beep up to 5 times to indicate signal strength. Number of Beeps 1 2 3 4 5 Signal Strength Very weak Weak Medium Good Very good 6. if the signal strength is acceptable press the button on the side of the smoke detector and it is now paired with the master. The system is now operational. Note: to add further smoke detectors repeat previous steps 1 to 6

step 4 radio link alarm interface module stage one, Wall fastening To open / and closing the box: remove the 4 screws from the lid. Dimensions : H 83 mm x L 83 mm x D 46 mm Hole pitch for wall fixing: 40 mm. Avoid installing the radio link alarm interface module in a metallic cupboard or cabinet or fixing it on a metallic wall, as they could screen against radio waves. Use the integrated radio link quality checking feature to determine the best location. stage two, Wiring Suitable wire : 8/10th, max. length : 100 meters. Pass the wires through one or several cable glands. stage three, configuring your interface into the system Follow the steps to connect the radio link interface module to a smoke detector or a stand alone alarm 1. Power up the radio link interface module (slave). 2. Press the configuration key for 5 seconds, you will hear 3 beeps, The interface sends a message to be associated to the existing group. 4. Press the test key of a smoke detector or the validation key of a stand alone alarm. You will hear one long beep 5. The interface is now linked to the master unit and will now enter the signal strength mode. 6. Take the interface to the required location and ensure the signal strength is adequate, the unit will beep indicating the signal strength. You should try to achieve at least a signal strength of 3 (see previous tables - 5 good 1 bad) 7. Mount the slave element on the chosen location. 8. Press the configuration key of the interface you will hear 4 beeps as it exits optimisation mode and a further 4 beeps as it exits configuration mode. 9. The system is now operational To Cancel the connection with a smoke detector or a stand alone alarm While in step 2, press the configuration key for 10 seconds (instead of 5 seconds) (see stage three step 2. above). 4 long beeps will be heard indicating that the connection is cancelled.

Maintenance notes We advise you to keep the equipment clean and to ensure the installation is in a dry and ventilated area. Checking that components are connected and their signal strength in Diagnostic Mode To activate the diagnostic mode, press the transparent switch on the master unit for 5 seconds. The diagnostic mode is activated when the green LED of the master unit blinks. Each connected unit beeps, the beeps correspond to the quality of the signal strength. Faults Master unit Faults A fault is identified by a flashing orange light on the master unit and a number of beeps on the master and/or the MCP. Number of beeps Faulty Unit Fault Explanation 1 Master Battery The master unit battery is faulty 2 Master MCP Battery The master unit MCP battery is faulty 3 MCP Battery An MCP has a faulty battery 4 MCP Communication An MCP has a communication fault Manual call point (MCP) faults Number of beeps Faulty Unit Fault Explanation 1 MCP Battery The manual call point battery is faulty 2 MCP Communication No signal has been recieved Battery Fault Replace the defective Lithium 3Vcc CR 17 345 for the MCP including the One installed in the master unit. Replace the 9V 6 LR 61 battery inside the master unit. Communication Fault Go in to the diagnostic mode described earlier to check the quality and strengh of the signal, relocate if required or investigate if there is a new obstruction or interference causing the fault. Clearing Configuration / Decommissioning If at any point you are unsure of the number of MCP s paired with the system, or are having problems commissioning, or wish to relocate the wireless system or reduce the number of paired units, then you will need to decommission the slaves one at a time. Both the P300W and D300W can not be decommissioned, however, the D300W can be moved and re-commissioned, using the normal procedureas set out in the step 3 to a different master To decommission the a C300W, you will need to: Press and hold the CONFIG button, then whilst holding down the CONFIG button also press and hold the VALID button, until you here 3 short beeps, 4 long beeps followed by 1 short beep and then release the buttons, the C300W is now decommissioned from the system and can be added back using the normal procedure as set out in step 2.