MR SERIES CARD LOGGERS

Similar documents
AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

USER MANUAL USB Multi-Function Datalogger Model RHT35

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Refrigerator/Freezer Thermometer

THERMOMETERS Dataloggers/Refrigerator

Refrigerator/Freezer Thermometer

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

ECOLOG Data logger series we prove it.

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Compact Ultra Low Temperature Chamber

Infrared Temperature Sensor

JW SERIES. Three Phase Thyristor Regulator PSE-351

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Frequently asked questions: Intelligent Transmitter Series

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

HOBO U14 Data Logger User Manual

Mark 25 Ultrapure Water Conductivity Analyzer

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

SMS GSM Alarm Messenger

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

Remote Conditioners. RC-Series. ZPRC Series

OPUS20 LAN-Datalogger Future Inside

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Constant climate chambers

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

BIOMEDICAL REFRIGERATORS

COA-2010-F Electronic CO 2

REC-8R Environmental Control. Operation and Installation Manual

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Instruments. for hydroponics & horticulture 2016

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

Pioneer in HAST Technology HIRAYAMA MANUFACTURING CORPORATION

Infrared Moisture Balance (FD-800)

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Constant climate chamber with humidity

ISO New Product Catalog. Addendum 2014 TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS

EasyLog Data Logger Series

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Altitude Chambers.

Remote Conditioners. RC-Series. ZPRC Series

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

Liquid Helium Level Instruments

Environmental.

Multi-Lab REFRIGERATORS Frigidere medicale

Constant climate chambers

data logger DL200H DL200D DL200L

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Dräger X-am 7000 Multi-Gas Detection

onlinecomponents.com

iminiplus PDF User Guide Version 2.0

Variable Frequency Drive SERIES MP800 VFD

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

EasyLog Data Logger Series

EL-USB-1-LCD Temperature Data Logger with LCD

Constant climate chambers

Temperature/Humidity Monitor. User s Manual

Infrared Moisture Determination Balance FD-610. Operating Manual

Global Laboratory Catalog

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

Ultra low temperature freezers. -40 C and -86 C. Green Line

2014, TempSen Electronics Company

Stability Chambers & Rooms

BRIEFING OF U-CAN : Honesty Innovation Sharing - CHOOSE U-CAN ; MAKE YOU CAN- Certificated manufacturer of ISO and CE Conformity.

Do you know the three blind spots of traditional aspirating smoke detector system?

Digital, not analog: One manifold for all refrigeration systems.

Tinytag Ultra Data Logger Manual

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Wet Bulb Thermo-Hygrometer Datalogger

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

portable gas analyser

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

EL-USB-TC Thermocouple Data Logger with USB Interface

Controllers, Indicators & Set Point Programmers

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

FITOCLIMA 600 & 1200 PHARMA

Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

Personal ph, ph/orp, Conductivity Meters

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Transcription:

MR SERIES CARD LOGGERS SPLASH PROOF TYPE TEMPERATURE CARD LOGGER MODEL MR5300 Model MR5300 is a small size and lightweight card logger capable to store up to 6000 temperature data, and is washable (IP64 - splash proof). Various types of external mounting sensors including a built-in type are available. Recalling of data and programming of logging parameters can be executed with this card logger or through a personal computer. This card logger conforms to CE and IP-64. FEATURES A traceability or inspection certificate, which can be used for HACCP or ISO9000, is available. (Separate purchase required) IP 64 (dust tight and splash proof) enclosure CE conformance High accuracy ±0.5ºC (for 5 to 50ºC) Automatic stop or endless of data logging is selectable. Small/lightweight and easy-to-operate Built-in totalizing function Keeping of stored data for long term on low battery Stored data can be recalled during logging of data. Measurement interval of 10 to 50 seconds or 1 to 60 minutes Storing of about 730 thousand data in a 1.44MB floppy disk (by exclusive file format) APPLICATIONS Temperature monitoring in refrigerators/freezers Temperature monitoring in transportation Freshness monitoring of vegetables or fruits Temperature monitoring in show cases Transportation/storage temperature monitoring of pharmaceuticals Temperature monitoring in green/vinyl houses Temperature monitoring in chambers Temperature monitoring in refrigerated trucks/warehouses Temperature monitoring in cement curing 1 PSE-481

SPECIFICATIONS (Model MR5300) Measuring range: Accuracy rating: Sensor: Input point: Number of data stored: Storing mode: Communications function: Display: Display contents: Totalization: Alarm: Battery: Working environment: Storage environment: Housing structure: -40 to 60ºC, 0 to 100ºC, 50 to 150ºC (0 to 50ºC is available. For display only) (Ranges are automatically switched by judging a sensor to be used.) ±1.0ºC ± 1 digit (±0.5ºC ± 1 digit for 5 to 50ºC) Built-in/External switching (Automatically switched to External when an external mounting sensor is inserted, Measuring range of the built-in sensor: 40 to 60ºC) One 6000 data (About 8-month data storage at the 60-minute measurement interval) Automatic stop mode under specified conditions or endless mode by a PC Built-in (Connection to a PC through a data readout unit) Reflection type liquid crystal display Current data: Month, day, hour, minute, temperature (ºC) Recalling data: Data being stored per month, day, hour, minute or the following data in the stored data Totalized data (ºCH) of lower (L) or higher (H) temperature than a reference temperature Number of activated alarms for higher or lower limit, and month, day, hour, minute and its temperature of activated alarm Maximum, minimum and average temperatures Parameters: Clock: Year, month, day, hour, and minute (Corresponding to leap years) Start time: Month, day, hour, and minute Measurement interval: 1 to 60 minutes (1-minute increments) or 10 to 50 seconds (10-second increments) Reference temperature: Reference temperature for totalization Low battery: Display will blink when the batteries are low. High or low totalization High or low alarm AAA (UM-4), 2 pieces Battery life: About 1 year (At 25ºC and 10-minute interval) -20 to 55 ºC; 10 to 80%RH (No condensation) -20 to 55ºC; under 90%RH (No condensation) IP64 (Splashing proof) Material/color: ABS Resin, PANTONE color (equivalent to 552C) Outside dimensions/weight: 54 (W) x 110 (H) x 20.5 (D) mm, 95g (Including batteries) CE-marking: EN-61326, Emission: Class B, Immunity: Requirement for portable test and measurement equipment DIMENSIONS Convenience totalizing function H totalized value (ºCH) = (Measured Temperature - Reference Temperature) x Hours L totalized value (ºCH) = (Reference Temperature - Measured Temperature) x Hours * The totalizing function only executes when the value in ( ) is over than 0ºC. The range of the totalizing temperature is from 0 to 99990ºCH. (Example) Reference temperature: 2.0ºC Measured temperature of 25.5ºC for 100 hours and 5.5ºC for 50 hours The H totalized value becomes 2525 (ºCH). (25.5-2.0) x 100 + (5.5-2.0) x 50 =2525 2

For simultaneous data logging of temperature in 2 places SPLASH PROOF TYPE TWO-CHANNEL CARD LOGGER MODEL MR5320 Model MR5320 is a small size and lightweight 2-channel card logger capable to monitor temperature in two places and store up to 6000 data per channel, and is washable (IP64 - splash proof). By connecting this unit to a personal computer through the data readout unit MR9503, all data can be displayed or printed out in a table format or a trend graph format, and also the data stored can be treated by worksheet applications commercially available. This card logger conforms to CE and IP-64. FEATURES Storing of 6000 data per channel Measurement interval of 10 to 50 seconds or 1 to 60 minutes High accuracy ±0.5ºC (for 5 to 50ºC) Automatic stop or endless of data logging is selectable. Keeping of stored data for long term on low battery Storing of about 730 thousand data in a 1.44MB floppy disk (by exclusive file format) Reliable infrared communications between the card logger and the data readout unit without any physical contact IP 64 (dust tight and splash proof) enclosure CE conformance Various kinds of sensors including a general type, a water-proof type, a surface type and a needle type A traceability or inspection certificate, which can be used for HACCP or ISO9000, is available. (Separate purchase required) APPLICATIONS Temperature monitoring in research and laboratories Monitoring of temperature difference Monitoring of multiple temperature in various kinds of applications Temperature monitoring in green/vinyl houses 3

SPECIFICATIONS (Model MR5320) Measuring range: -40 to 60ºC, 0 to 100ºC, 50 to 150ºC (Ranges are automatically switched by judging a sensor to be used.) * With the built-in sensor (Channel 1 only): -40 to 60ºC Accuracy rating: Sensor: Input point: Number of data stored: ±0.5ºC ± 1 digit (for 5 to 50ºC) * Except above: ±1.0ºC ± 1 digit Built-in (Channel 1 only)/external switching * Various types of sensors (separate purchase required) including general type, water-proof type, needle type and surface type are available. Two points 6000 data/each channel Display contents: Current data: (Each channel) Month, day, hour, minute, measured temperature in Channel 1 and Channel 2 Recalling data: Maximum temperature, minimum temperature and average temperature in stored data in Channel 1 and 2 Parameters: High alarm setpoint and low alarm setpoint of Channel 1 and 2 Operation by logger: Communications function: Display start-up (With auto-off function: Display goes out after one minute.) Display content selection (clock setting, logging start/stop, key lock/release) * Three function keys of DISP, SEL and REC Infrared communications to the exclusive data readout unit (separate purchase required) Settings of parameters and recalling of stored data/logging parameters by the exclusive analytical software package Settings by PC: Clock, logging start time/stop time (in case of the measurement interval of 1 to 60 (Exclusive analytical software) minutes), measurement/logging interval (10 to 50 seconds or 1 to 60 minutes), high/low alarm temperatures, key locking of logger, logging mode (automatic stop/endless) Battery: Battery life: AAA (UM-4), 2 pieces About 1 year (At 25ºC and 1-minute interval) Outside dimensions/weight: 54 (W) x 110 (H) x 20.5 (D) mm, 95g (Including batteries) CE-marking: EN-61326, Emission: Class B, Immunity: Requirement for portable test and measurement equipment DIMENSIONS MOUNTING HOLDER (common to MR5300 and MR5320) This is used to fix the card logger to equipment, iron poles or wall. Model: MR9013 Mounting: By screws Material: SUS304 4

EXTERNAL MOUNTING TEMPERATURE SENSORS (common to MR5300 and MR5320) General type MR9301 (-40 to 60ºC) MR9302 (0 to 100ºC) MR9303 (50 to 150ºC) With long lead wire MR9301M05 (-40 to 60ºC/5m) MR9302M05 (0 to 100ºC/5m)) MR9303M05 (50 to 150ºC/5m) MR9301M10 (-40 to 60ºC/10m) MR9302M10 (0 to 100ºC/10m)) MR9303M10 (50 to 150ºC/10m) MR9301M15 (-40 to 60ºC/15m) MR9302M15 (0 to 100ºC/15m)) MR9303M15 (50 to 150ºC/15m) With water-proof tube MR9301S30 (-40 to 60ºC) MR9302S30 (0 to 100ºC) With metal tube MR9301A30 (-40 to 60ºC) MR9302A30 (0 to 100ºC) MR9303A30 (50 to 150ºC) With metal tube (sanitary) MR9301B30 (-40 to 60ºC) MR9302B30 (0 to 100ºC) MR9303B30 (50 to 150ºC) Surface temperature MR9301B30 (-40 to 60ºC) MR9302B30 (0 to 100ºC) MR9303B30 (50 to 150ºC) Needle type (with grip holder) MR9301C05 (-40 to 60ºC/sensor 50mm) MR9302C05 (0 to 100ºC/ sensor 50mm) MR9301C10 (-40 to 60ºC/sensor 100mm) MR9302C10 (0 to 100ºC/ sensor 100mm) MR9301C20 (-40 to 60ºC/sensor 200mm) MR9302C20 (0 to 100ºC/ sensor 200mm) Needle type (with finger holder) MR9301D05 (-40 to 60ºC/sensor 50mm) MR9302D05 (0 to 100ºC/ sensor 50mm) MR9301D10 (-40 to 60ºC/sensor 100mm) MR9302D10 (0 to 100ºC/ sensor 100mm) MR9301D20 (-40 to 60ºC/sensor 200mm) MR9302D20 (0 to 100ºC/ sensor 200mm) Remarks: For CE conformance, the external mounting sensors of Models 9301, 9302 and 9303 only are applicable to MR5300 or MR5320. 5

TEMPERATURE HUMIDITY CARD LOGGER MODEL MR6661 The MR6000 series small size and lightweight card loggers are for simultaneous logging of temperature and humidity and are capable to store up to each 3000 data of temperature and humidity. For accurate and reliable humidity measurement, an interchangeable element (capacitance type high polymer film) is used. Recalling of stored data and settings of logging parameters can be executed by this logger or through a personal computer. This card logger conforms to CE. FEATURES Simultaneous measurement and logging of temperature and humidity Up to 3000 data storage of temperature and humidity Interchangeable humidity element (capacitance type high polymer film) Programmable measurement interval from 1 to 60 minutes (At the measurement interval of 10 minutes, data are stored up to about 20 days.) Small/lightweight and easy-to-operate Recalling of stored data and settings of logging parameters by this logger or through a personal computer Keeping of stored data by backup function on low battery A traceability or inspection certificate, which can be used for HACCP or ISO9000, is available. (Separate purchase required) CE conformance APPLICATIONS Temperature and humidity control in computer rooms, Temperature and humidity control in plants of electronic equipment Inspected data recording of housing-related instruments Temperature and humidity control in museums Freshness control of vegetables, flowers, etc. Temperature and humidity control in constant temperature warehouses and containers Environmental control of electronic and communication equipment Measurement of temperature and humidity in green houses Environmental measurement of temperature and humidity For teaching tools in schools 6

SPECIFICATIONS (Model MR6661) Measuring range: Temperature -40 to 60ºC Humidity 0 to 100% (no dew condensation) Accuracy rating: Temperature ±0.5ºC (for 5 to 50ºC) (Except above: ±1.0ºC) Humidity ±3%RH (at 25ºC ± 2ºC/0 to 90%RH) Input point: Number of data stored: Display contents: Alarm: Temperature 1 point, humidity 1 point Temperature/humidity each 3000 data (Data storing for about 20 days at the measurement interval of 10 minutes) Current data: Month, day, hour, minute, temperature (ºC), humidity (%RH) Recalling data: Data being stored per month, day, hour or minute Maximum temperature/humidity, minimum temperature/humidity and average temperature/humidity Parameters: Clock Year, month, day, hour, minute (corresponding to leap years) Start time - Year, month, day, hour, minute Logging interval 1 to 60 minutes (1-minute increments) High/low alarm setpoints ALARM appears on alarm activation. Working environment: Logger - -20 to 50ºC Temperature/humidity sensor - -30 to 60ºC (no dew condensation) Outside dimensions/weight: Logger - 54 (W) x 105 (H) x 14 (D) mm Sensor - 18 (W) x 53 (H) x 11 (D) mm Weight: 120g (Logger about 80g) Battery: Battery life: CE-marking: AAA (UM-4), 2 pieces About 1 year (At 25ºC and 10-minute interval) EN-55011, Group 1, Class B, EN-50082-1 DIMENSIONS MOUNTING HOLDER This is used to fix the card logger to equipment, iron poles or wall. Model: MR9011 7

DATA READOUT UNIT (applicable to all card loggers) MODEL MR9503 Card loggers can display or printed out data in a table format or a trend graph format by connecting to a personal computer through this data readout unit. The data stored can be managed by a file and treated by worksheet applications commercially available. The card loggers can connect to this data readout unit through reliable infrared communications without any physical contact. SPECIFICATIONS (With analytical software package) Model MR9503 PC DOS/V D-sub 9-pin RS232C connector With a cable of 1.5m attached with a noise filter Environment Windows 3.1/95/98 Hard disk: 1MB free space or more Communications Between a card logger and this data readout unit: Non-contact infrared type Between this data readout unit and a PC: RS-232C (communications at a serial port) Weight About 180g ANALYTICAL SOFTWARE PACKAGE Model MR5300 MR5320 MR6661 Clock, start time, measuring interval, totalizing direction, card No., test No., Key lock/release (MR5320 only) Settings Logging type, number of data Logging type, number of data at Logging type, reference value at logging end, high/low alarm logging end, high/low alarm setpoints setpoints, reference value Recalling Parameters, stored data, number of stored data, number of errors Computation Maximum value, minimum value, average value Totalized value ---- Totalized value All data (measured data per year, month, day, hour, or minute) Display Trend graph ---- High/low alarms (alarm mark attached to the data) Data storage Storage in file format or text format by this software package Printout List printing, parameter printing, trend graph DIMENSIONS Specifications subject to change without notice. Printed in Japan (I) 2002.1 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jp Website: http://www.chino.co.jp 8