NYC Department of Education

Similar documents
NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education Building Condition Assessment Survey :49AM :00PM

PLATTEVILLE MIDDLE SCHOOL

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

Electrical Inspection Special Electrical

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

DIVISION 16 - ELECTRICAL

Florence High School / Middle School Page 1 of 3 Florence, WI

Transcription:

NYC Department of Education Building Assessment Survey 2017-2018 Asset: TERS PREP HS(OL REDIRECTION)-K, 226 BRISTOL STREET, New York, 11212 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-01-05 9:00 AM 2018-01-19 2:44 PM Asset Data Type of Service Does Interactive Whiteboard (IWB) Exist? Water Penetration in Electrical Room? Have any Systems/Major Building Components been upgraded? DEDICATED INTERCOMS IN FIRE RESCUE AREAS Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms in your building? Are dedicated intercoms available in all of these spaces for use during a fire? Are all dedicated intercoms operational? Answer Below Ground Years: Years: 2017 Years: 2016 Years: 2015 Years: 2012 Fire Alarm System, Public Address System, Local Sound System (Gymnasium, Cafeteria), Auxiliary Signal/Bell System Under construction Telephone System Interior Fluorescent (Except Library, Science Lab - Room 406, Science Prep Room 408), Exit Light (Battery Pack), Emergency (n Battery Pack), LED Computer Lab - Room 202 (Raceway With Receptacles) IPDVS/CCTV System Science Lab - Room 406, Science Prep Room 408 Years: 2011 Years: 2009 Library, Exit/Emergency Light LAN Years: 2007 Years: 2000 Years: 1998 Intrusion Alarm System All Other Electrical Systems and Components Switchboard Years: 1992, 1998 Priority Priority Priority Exist Category Last Year? Description Component Affected Location Description Person(s) tified Person(s) Title Status PhotoImage Water Leaks onto Electrical N/A Fixture Girls Locker Room, Toilet Room inside Girls Locker Room David Feliciano Custodian Sent to DSF Inspection Electrical PB/A&W Page 1 of 13

Building Assessment Survey 2017-2018 AUDITORIUM CAFETERIA Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Local Sound System Projection System Theater System CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Does a Chandelier exist? Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED COMPUTER LAB PB/A&W Page 2 of 13

COMPUTER LAB Power Panel Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles GYMNASIUM Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 3 of 13

GYMNASIUM Fixture - LED Local Sound System Projection System Scoreboard Theater System Dimming System Theater KITCHEN Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED LIBRARY NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 4 of 13

Building Assessment Survey 2017-2018 LIBRARY Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles Projection System LOCKER ROOM Alternative use Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED MULTIPURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB PB/A&W Page 5 of 13

SCIENCE LAB Power Panel Alternative use Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Emergency Gas Shut-Off Valve Emergency Shut-Off Power Power Supply Projection System SCIENCE PREP ROOM Power Panel Alternative use Fixture - Fluorescent NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 6 of 13

SCIENCE PREP ROOM Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Emergency Gas Shut-Off Valve Emergency Shut-Off Power Power Supply SWIMMING POOL TOILET ROOM - STAFF Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED TOILET ROOM - STUDENT Fixture - Fluorescent NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 7 of 13

Building Assessment Survey 2017-2018 TOILET ROOM - STUDENT Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED AUXILIARY SIGNAL/BELL SYSTEM EMERGENCY DC STANDBY BATTERY POWER EMERGENCY GENERATOR SET Automatic Transfer Switch (ATS) Manufacturer Kohler Power Systems N/A Capacity/Size Quantity 400 Amps Manufacturer Kohler Power Systems N/A Capacity/Size Quantity 70 Amps Battery Charger Manufacturer Kohler Power Systems Battery Charger Capacity/Size Quantity 10 AmpsDC PB/A&W Page 8 of 13

Building Assessment Survey 2017-2018 EMERGENCY GENERATOR SET Battery Charger Capacity/Size2 Quantity 13 Capacity/Size2 UOM VDC Diesel Inaccessible Natural Gas EMERGENCY LIGHT/EXIT LIGHT PANEL EMERGENCY LIGHTING Battery Pack n Battery Pack EXIT LIGHT Battery Pack n Battery Pack FIXTURE NOT OPERATIONAL Location/ Corridor by Room 102 Quantity 1 Quantity Uom Potential Action REPLACE Urgency of Action PRIORITY 5 Purpose of Action LEVEL 2 Photo1 photo recorded Violations violations recorded. EXIT/EMERGENCY LIGHT CITY FIRE ALARM SYSTEM FIRE ALARM SYSTEM GROUNDING SYSTEM INTERCOM SYSTEM Elevator Holding Area LAN PB/A&W Page 9 of 13

Building Assessment Survey 2017-2018 LAN Local Distribution Frame (I/LDF) Main Rack (MDF) LIGHTNING PROTECTION MOTOR CONTROL CENTER MOTOR STARTER/CONTACTOR PANEL BOARD Fused Disconnect Switch Type Fused Knife Switch Type Fused Toggle Switch Type Molded Case Circuit Breaker Type NO SPARE Location/, Corridor by Rooms (205, 356) Quantity 3 Quantity Uom Potential Action INSTALL NEW PANEL BOARD Urgency of Action PRIORITY 3 Purpose of Action LEVEL 2 Photo1 photo recorded Violations violations recorded. PUBLIC ADDRESS SYSTEM SECURITY IPDVS/CCTV System Replacement Quantity 89,000 Replacement Uom Installation Year 2012 Intrusion Alarm System S.F. Custodial Staff Replacement Quantity 89,000 Replacement Uom Central Control Panel Model S.F. Custodian's Office Installation Year 2000 Vista - 128B Custodial Staff PB/A&W Page 10 of 13

Building Assessment Survey 2017-2018 SECURITY Intrusion Alarm System Central Control Panel PANEL NOT CONNECTED TO DOE CENTRAL STATION Quantity 1 Quantity Uom Potential Action INSTALL CONNECTION Urgency of Action PRIORITY 4 Purpose of Action LEVEL 3 Photo1 photo recorded Violations violations recorded. Infrared Sensor Panic Switch Remote Annunciator Siren/Strobe Ultrasonic Sensor - Security Replacement Quantity 23 Replacement Uom LIGHTING FIXTURE NOT OPERATIONAL Location/ Upper Roof Quantity 4 Quantity Uom Potential Action REPAIR Urgency of Action PRIORITY 2 Purpose of Action LEVEL 3 Photo1 photo recorded Violations violations recorded. SERVICE SWITCH Manufacturer General Electric Main SRVC DISC Capacity/Size Quantity 2,000 Amps PB/A&W Page 11 of 13

Building Assessment Survey 2017-2018 SERVICE SWITCH Manufacturer General Electric EMDP Capacity/Size Quantity 400 Amps Manufacturer General Electric Kitchen Capacity/Size Quantity 200 Amps SWITCHBOARD Number of Spares 3 Air Circuit Breaker Type Fused Disconnect Switch Type Electrical Room B8 Manufacturer General Electric N/A Capacity/Size Quantity 2,000 Amps Total Capacity/Size2 Quantity 2 Capacity/Size2 UOM Section(S) Manufacturer General Electric PB/A&W Page 12 of 13

Building Assessment Survey 2017-2018 SWITCHBOARD Fused Disconnect Switch Type EMDP (Emergency Generator Switchboard) Capacity/Size Quantity 400 Amps Total Capacity/Size2 Quantity 1 Capacity/Size2 UOM Section(S) Fused Knife Switch Type Molded Case Circuit Breaker Type TELEPHONE SYSTEM PBX/Intercom TELEPHONE NOT OPERATIONAL Location/ Rooms 406, 501 Quantity 2 Quantity Uom Potential Action REPLACE TELEPHONE Urgency of Action PRIORITY 3 Purpose of Action LEVEL 2 Photo1 photo recorded Violations violations recorded. Standard TRANSFORMER TV SYSTEM Cable System Exist? Operational? Main Rack PB/A&W Page 13 of 13