Rosemount 3490 Series

Similar documents
Mobrey MCU900 Series Universal Control Unit

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Annubar Flowmeter Series

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2100 Series

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 4500 Hygienic Pressure Transmitter. Start

Emerson Wireless SmartPower Solutions

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 752 Fieldbus Remote Indicator

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 3051S Electronic Remote Sensors

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount High Density Temperature Measurement. Simplify Your Project

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 702 Wireless Discrete Transmitter

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Rosemount 2160 Wireless Vibrating Fork Level Switch

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 3051 Pressure Transmitter

Net Safety ST3 XChem Toxic Gas Sensor

High Pressure Conductivity Monitor

Rosemount 248 Temperature Transmitter

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Rosemount 2051G Pressure Transmitter

Rosemount 752 Remote Indicator

Rosemount 2088 Absolute and Gage Pressure Transmitter

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Rosemount 3051S MultiVariable Transmitter

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Rosemount 705 Wireless Totalizing Transmitter

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 8800D Series Vortex Flowmeter

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Sanitary Pressure Transmitter

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 1595 Conditioning Orifice Plate

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Rosemount 2130 Level Switch

Dräger Polytron 8310 Stationary gas detector (DSIR)

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

4) Intrinsic Safety Certification

Temperature Measurement Transmitters for field mounting

Enraf Servo Gauge 854 XTG

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Dräger QuadGard Control System

Rosemount 248 Temperature Transmitter

Rosemount 3051HT Hygienic Pressure Transmitter

Manual Power relay SR853

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Danfoss gas detection unit Type GD Heavy Duty

Rosemount 644H and 644R Smart Temperature Transmitters

Dräger Polytron 8200 Stationary gas detector (CatEx)

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

Rosemount 2088 Absolute and Gage Pressure Transmitter

Dependable Solutions for Gas Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Certification Supplement Manual

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Indoor/outdoor resistance thermometer Model TR60

Inductive slot sensor

Dräger Flame 5000 Flame Detection

Transcription:

Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall mount enclosure for internal or external mounting Accepts 4 20 ma and HART inputs Compatible with HART 7 transmitters Intrinsically Safe power supply to a transmitter Isolated 4 20mA output Five field adjustable alarm / control relays Pre-programmed with tank shapes, flow algorithms, and pump control routines to simplify configuration

Rosemount 3490 Series July 2014 Overview of the Rosemount 3490 Series The Rosemount 3490 Series of wall and panel mounting control units provide comprehensive control functionality for any 4 20 ma or HART compatible transmitter. A back-lit display gives clear visual indication of the measured value and status of all inputs and outputs. Features and benefits Tough weatherproof wall mount enclosure for internal and external mounting Wall mount, IP65 version of the Rosemount 3490 Series controller unit Accepts 4 20 ma or HART inputs. Compatible with HART 5, 6, and 7 Transmitters Five voltage-free SPDT relays for alarm and control duties Supports two voltage-free contact closure inputs 4 20 ma 12-bit isolated current output proportional to calculated value Bright local display of measured value and input/output status Pre-programmed tank shapes, flow algorithms, and control routines simplify configuration. A 20-point strapping table facility is provided for non-standard applications Real-time clock for energy saving routines, pump efficiency calculations, and date/time stamping of data logging Wall Mount, NEMA 4X version of the Rosemount 3490 Series controller unit The 3490 Series is mounted in a non-hazardous area, and provides a protected (intrinsically safe) 24 volts direct current supply to a transmitter in a hazardous area. Ideal for programming and control of Rosemount level and flow transmitters It is ideal for programming and control of Rosemount 3100 Series level and flow transmitters, and Rosemount 3300 Guided Wave Radar level and interface transmitters (non-explosion-proof only). Panel Mount version of the Rosemount 3490 Series controller unit Other HART transmitters can be connected. The 3490 Series recognizes the transmitters as an unknown instruments but allows access to programming of Universal and Common Practice HART commands. Contents Overview of the Rosemount 3490 Series........ page 2 Product Certifications.................. page 7 Rosemount 3490 Series Control Unit Ordering.. page 4 Dimensional Drawings................. page 8 Specification................................ page 5 2

July 2014 Rosemount 3490 Series Special features Configured and interrogated using an integral six-button keypad Easy to navigate menu structure Wizard assisted programming, with password protection to prevent unauthorized access Many popular configurations are Wizard assisted, enabling fast and accurate programming. Typical applications include level, volume, distance measurement, and open channel flow measurement The HART digital or 4 20 ma analog signal from the transmitter may be offset, dampened, scaled, and linearized. A range of pre-programmed linearization algorithms are user-selectable IN1 IN2 Digital input status On-line status Digital communication Status 1. 572 m 12: 47 Measured variable Bar graph of 4 20 ma output Typical display of the Rosemount 3491 Relay status RL1 RL2 RL3 RL4 RL5 The 4 20 ma output signal may be scaled to re-transmit all or just part of the transmitter s input signal or calculated value Five relays are fully field programmable to perform a variety of control, fault indication, and alarm duties Two digital inputs can be individually set-up to perform various control actions (e.g. raise an alarm) whenever activated Choosing the right control unit Each control unit of the 3490 Series has been designed for a specific purpose: Table 1. Choosing the right control unit 1.572m 1 1.572m 12:47 1 SETUP Run? MONITOR MAIN MENU Easy to navigate menu structure Control Units Models Ordering information Control Unit 3491 See page 4 Differential Measurement Control Unit 3492 See page 4 Logging Measurement Control Unit 3493 See page 4 3490 3491 Model type: The Control Unit accepts input from one transmitter The Rosemount 3492 Differential Measurement Control Unit accepts input from two HART transmitters and performs sum or differential calculations, providing a single current output proportional to the answer The Rosemount 3493 Logging Measurement Control Unit provides on-board logging of the process/primary value (PV), and totalized open channel flow Level or volume measurement with a Rosemount 3490 Series Control Unit and Rosemount 3100 Series Level Transmitter 3

Rosemount 3490 Series July 2014 Rosemount 3490 Series Control Unit Ordering Rosemount 3490 Series control unit ordering information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 6 for more information on Material Selection. Table 2. Rosemount 3491, 3492, and 3492 ordering information The offering represents the most common models and options. These options should be selected for best delivery. The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time. Model Product Description 3491 Control Unit 3492 Differential Control Unit 3493 Logging Control Unit Signal Output L 4 20 ma Power Supply 1 115/230 Vac 2 24 Vdc Enclosure / Mounting P6 Wall mounting, IP65 P7 Panel mounting, IP40 P4 Wall mounting, NEMA 4X Product Certificates I1 ATEX Intrinsically Safe I3 NEPSI Intrinsically Safe I5 (1)(2) FM Intrinsically Safe I6 (3) CSA Intrinsically Safe I7 IECEx Intrinsically Safe IM (4) Technical Regulation Customs Union (EAC) Intrinsically Safe Typical Model Number: 3491 L 1 P4 I5 (1) Enclosure/Mounting code P4 is required for this option. (2) Power supply code 1 is required for this option. (3) Enclosure/Mounting codes P4 or P7 are required for this option. (4) Contact an Emerson Process Management representative for additional information. Accessory ordering information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 6 for more information on Material Selection. Table 3. Accessory ordering information The offering represents the most common models and options. These options should be selected for best delivery. The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time. Accessory 03490-7001-0001 IP65 hood kit for panel-mountable control unit (P7 option in Table 2) 4

July 2014 Rosemount 3490 Series Specification General Product Rosemount 3490 Series Universal Control Unit: 3491 Control Unit 3492 Differential Control Unit 3493 Logging Control Unit Mounting styles Wall or panel mount Power options AC mains or DC Display Type Dot matrix LCD, 32 x 122 pixels, back lit Location Integrated into enclosure Indicators Red LED for health status Electrical AC mains power supply input 115 or 230 Vac ±10% (switch selectable) Power consumption: 10 VA nominal, 18 VA maximum Fuse: 200 ma(t), 5 x 20 mm, 250 V DC power supply input 15 to 30 Vdc, 30 Vdc maximum Power consumption: 9 W maximum Current input 4 20mA (Earth referenced in control unit) or HART digital communications (Rev. 5, 6, and 7) One HART transmitter on the Rosemount 3491 and 3493, and two HART transmitters on the Rosemount 3492 Supplies 23 volts from 400 Ohm source resistance Trigger inputs 2 voltage-free contact closures Relays 5 x SPDT, 5 A at 240 Vac Current output Signal range (nominal): 4 20 ma Output range (linear): 3.8 to 20.5 ma (user-selectable alarm current of 3.6 ma, 21 ma, or 22.5 ma) or 3.9 to 20.8 ma (user-selectable alarm current of 3.75 ma, or 21.75mA) Load: Rmax is 1 K Ohm Resolution: 12-bit Regulation: < 0.1% over load change from 0 to 600 Ohms Isolation: Isolated from other terminals to 500 Vdc Update rate (software): 5 times per second Cable entry IP-rated wall mount enclosure: 5 positions pre-drilled, 2 glands and 3 blanking plugs supplied NEMA-4X-rated wall mount enclosure: Positions require drilling by user, glands/conduits and blanking plugs are not supplied Panel enclosure: Direct wiring to terminal blocks at rear Cable connection Wall mount enclosure: Cage clamp terminal blocks in separate terminal compartment Panel mount enclosure: 2-part cage clamp terminal blocks at rear 5

Rosemount 3490 Series July 2014 Mechanical Material selection Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected. Materials of construction (wall mount) Polycarbonate enclosure and cover IP-rated wall mount: 304SST cover fixing screws NEMA-4X-rated wall mount: Polyester and Alloy 400 fastening UV resistant Polycarbonate membrane keypad Nylon cable glands and blanking plugs (IP-rated wall mount version only) Materials of construction (panel mount) Noryl PPO enclosure and cover Carbon Steel / Zinc plated fascia fixing screws UV resistant Noryl PPO membrane keypad Nylon + PBT terminal blocks with plated fittings Dimensions See Dimensional Drawings on pages 8 to 10 Weight IP-rated wall mount: 1.4 kg (mains unit) or 1.0 kg (DC unit) NEMA-4X-rated wall mount: 3.5 kg (mains unit) or 3.1 kg (DC unit) Panel mount: 1.2 kg (mains unit) or 0.8 kg (DC unit) Environment Ambient temperature 40 to 55 C ( 40 to 131 F) See Product Certifications on page 7 for approval temperatures ranges Relative humidity Wall mount: 100% Panel mount: 90% non-condensing Electrical safety EN61010-1 Ingress protection IP-rated wall mount: IP65 indoor/outdoor NEMA-4X-rated wall mount: NEMA 4X indoor/outdoor Panel mount: IP40 indoor mount (or IP65 if with optional hood) Vibration Control Room: 0.1 to 9 Hz 1.5 mm displacement peak amplitude / 9 to 200 Hz 0.5 g Installation category Category III: Supply voltage < 127Vac (IEC60664) Category II: Supply voltage < 254Vac (IEC60664) Pollution degree 2 (IEC60664) Maximum altitude 2000 m Electromagnetic compatibility Emissions and immunity (for IP-rated wall mount and panel mount): EN61326-1:2006 Certifications Intrinsically Safe associated apparatus See Product Certifications on page 7 6

July 2014 Rosemount 3490 Series Product Certifications European directive information The EC declaration of conformity for all applicable European directives for this product can be found in the Rosemount 3490 Series Product Certifications document 00825-0200-4841 and on the Rosemount website at. ATEX directive (94/9/EC) Emerson Process Management complies with the ATEX directive Low voltage directive (2006/95/EC) The Rosemount 3490 Series control unit complies with EN61010 Part 1 Pressure equipment directive (PED) (97/23/EC) The Rosemount 3490 Series control unit is outside the scope of PED Electro magnetic compatibility (EMC) directive (2004/108/EC) The Rosemount 3490 Series control unit complies with EN61326-1: 2006 Restriction of hazardous substances (RoHS) The Rosemount 3490 Series control unit is exempt Hazardous locations certifications The 3490 Series is mounted in a non-hazardous area, and provides a protected (intrinsically safe) 24 volts direct current supply to a transmitter in a hazardous area North American and Canadian approvals Factory Mutual (FM) intrinsically safe approvals I5 Contact an Emerson Process Management representative for additional information Canadian s Association (CSA) intrinsically safe approvals European approvals ATEX intrinsically safe approvals I1 Certificate numbers: SIRA 06ATEX7128 (Wall Mount), SIRA 06ATEX7129X (Panel Mount) Intrinsically safe for II(1) G D, [Ex ia] IIC, [Ex ia Da] IIIC Ambient temperature: 40 C to +55 C Uo = +27.3 V, lo = 96.9 ma, Po = 0.66 W, La = 2.26 mh, Ca = 70 nf Special conditions for safe use (SIRA 06ATEX7129X): Terminal 30 must be connected to a high integrity earth/ground point in a non-hazardous area Rest of the world approvals National Supervision and Inspection Centre for Explosion Protection and Safety Instrumentation (NEPSI) intrinsically safe approval I3 Certificate number: GYJ11.1710X Intrinsic safety: [Ex ia Ga] IIC IECEx intrinsically safe approvals I7 Certificate number: IECEx SIR 06.0104X Intrinsically safe for: [Ex ia] IIC, [Ex ia Da] IIIC Ambient temperature: 40 C to +55 C Uo = 27.3 V, lo = 96.9 ma, Po = 0.66 W, La = 2.26 mh, Ca = 70 nf Conditions of certification (panel mount): Terminal 30 must be connected to a high integrity earth/ground point in a non-hazardous area Technical Regulation Customs Union (EAC) IM Contact an Emerson Process Management representative for additional information I6 Project ID: 1830310 Intrinsically safe for: Class I, Division 1, Groups A, B, C, and D Intrinsically safe for: Class 1, Zone 0, Group IIC [Ex ia] Ambient temperature: 40 C to +55 C Control drawing: 71097/1201 Uo = 27.3 V, lo = 96.9 ma, Po = 0.66 W, La = 2.26 mh, Ca = 70 nf 7

Rosemount 3490 Series July 2014 Dimensional Drawings IP-rated wall mount unit 8.4 (212) (213) 4.9 (125) Lid Note: Dimensions are in inches (mm). Terminal Cover 3.3 (84) 3 (77) 2.3 (59) 0.8 (19.5) Body 7.3 (185) 1.4 (36) 1.1 (28) 2.2 (56) 3.3 (84) 5.5 (141) 5 holes Ø0.8 (Ø20.5) 0.6 (14.5) 0.96 (24.5) 5.8 (147.5) 7.8 (198) 8

July 2014 Rosemount 3490 Series NEMA-4X-rated wall mount unit 12.9 (328) Note: Dimensions are in inches (mm). 11.8 (300) 11 (280) 11.8 (300) 11 (280) 4 mounting holes Ø0.3 (Ø8) 5.5 (138.4) 9

Rosemount 3490 Series July 2014 Panel mount unit 5.7(144.8) Note: Dimensions are in inches (mm). 2.9 (74.7) 6.8 (173) 6.1 (156) 5.7(144.8) 2.6 (65.7) 2.9 (72.4) 0.1 (2) 5.43 (138) 0.3 (8) Panel cut-out (control unit) 2.68 (68) For safety, the panel should be strong enough to support the 1.2 kg (mains power) or 0.8 kg (DC power) mass of the unit. 0.13 (3.2) Ø0.81 (Ø20.5) 0.47 (11.85) Panel cut-out (RS232 data down-load socket on 3493 only) 10

July 2014 Rosemount 3490 Series 11

Rosemount 3490 Series 00813-0100-4841, Rev DA Product Data Sheet July 2014 Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (USA) 1 800 999 9307 T (International) +1 952 906 8888 F +1 952 906 8889 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE T +971 4 811 8100 F +971 4 886 5465 Emerson Process Management Latin America 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 USA T + 1 954 846 5030 Emerson Process Management Neuhofstrasse 19a CH 6341 Baar Switzerland T +41 (0) 41 768 61 11 F +41 (0) 41 76 1 87 40 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Signapore 128461 T +65 6777 8211 F +65 6777 0947 Service Support Hotline: +65 6770 8711 Email: Enquiries@AP.EmersonProcess.com Emerson Beijing Instrument Co No. 6 North Street, Hepingli Dongcheng District, Beijing 100013 China T +8610 6428 2233 F +8610 64287640 Terms and Conditions of Sale can be found at \terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART and WirelessHART are registered trademarks of the HART Communication Foundation All other marks are the property of their respective owners. 2014 Rosemount Inc. All rights reserved.