Electromagnetic Locking Devices Performance Requirements

Similar documents
Electromagnetic Locking Devices

Mechanically operated locks and locking plates

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Panic and Emergency Exit Devices

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Hardware for Sliding Doors & Folding Doors

Controlled Door Closing Devices

dhf General Information Automated Gates Guidance for enforcement bodies

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

GUIDELINIE ECB S R10. March European Certification Body GmbH

Specifying Security Hardware for Doors

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

ISO INTERNATIONAL STANDARD

Procedure for the Approval of New Fire Detection and Alarm Technologies

Contents EN :2006+A2:2016 (E)

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Conformity assessment procedures for the Alarm Components Scheme

INTERNATIONAL STANDARD

Domestic Garage Doors

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

INTERNATIONAL STANDARD

Technical Bulletin CE marking: from 1st July 2013

ISO INTERNATIONAL STANDARD

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

DHF Introduction DHF 2

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

INTERNATIONAL STANDARD

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SOUTH AFRICAN NATIONAL STANDARD

Guide to interpreting Markings for Single Axis Fire Doors Hinges

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

ISO INTERNATIONAL STANDARD

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Guidance Note No 19/1. CE Marking windows and doorsets

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

AS/NZS IEC :2015

CNBOP-PIB Standard Fire Protection

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Electromagnetic Compatibility of Alarm Systems

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Loss Prevention Standard

ISO INTERNATIONAL STANDARD

a guide to the interpretation of

Specification for testing to be conducted at periodic surveillance of products and systems

25 th November Title:

Gas meters - Conversion devices - Part 1: Volume conversion

PQS Independent type-testing protocol

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

AUGUST 2016 CONTENTS:

INTERNATIONAL STANDARD

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

SOUND RECEPTION SYSTEM

Microgeneration Certification Scheme: MCS 008

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Standards in Security Shutters & Fire Shutters (UK & USA)

Loss Prevention Standard

INTERNATIONAL STANDARD

This document is a preview generated by EVS

Review Fire Test Report

TECHNICAL SPECIFICATION

Water Heating UK 14 th May 2016

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Guide to gate safety legislation and standards

INTERNATIONAL STANDARD

Code of Practice: Hardware for Fire and Escape Doors

INTERNATIONAL STANDARD

This document is a preview generated by EVS

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

INTERNATIONAL STANDARD

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Centexbel. General certification regulations. Construction products

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Audible warning devices for external alarm

Transcription:

Technical Specification Electromagnetic Locking Devices Performance Requirements DHF TS 010:2016 Technical specification produced by dhf www.dhfonline.org.uk

Contents Foreword 1. Scope 2 ANNEX A Bodies ratifying this schedule 9 2. References 2 3. Terms and definitions 2 4. General requirements 3 5. Classification 4 6. Test requirements and procedures 6 7. Factory production control 8 8. Marking and labelling 8 9. Audit requirements 9 10. Installation instructions 9 Foreword This performance specification does not replace any existing performance specification. This specification defines the type of products, the technical and performance requirements for electromagnetic locking devices, including internalface fixed, internal morticed, internal shear magnets and external magnets. This specification does not provide for certification against European standards; it is designed to provide dhf approval for electromagnetic locking devices. Approval against the requirements of this performance specification is possible from February 2016. The aim of this specification is to provide approval for electromagnetic locking devices from dhf. The technical provisions of this specification have been adopted as a common basis for the approval of electromagnetic locking devices. This Technical Schedule does not cover the requirements for use on panic or emergency escape doors. 01 dhf Technical Specification

1. Scope This performance specification gives the requirements and test methods for the security, durability, fire and environment for electromagnetic locking devices when used on hinged, pivoted or sliding internal, external doors or gates. This specification does not detail the requirements for a certified ISO 9001 quality management system BUT will require compliance with the Clause 7 which relates to the requirements of Factory Production Control. The main purpose of the test is to prove the performance of the product when it is tested and passes to this specification. In addition to the requirements of this technical document TS 010, if additional fire characteristics are needed, then these shall be performed to EN 1634-1 or EN 1634-2. It is expected that the products to be tested have been EMC tested for low voltage devices to EN 61000. This performance specification does not cover those locks and strikes that are covered by EN 14846 or products covered by pren 13637 electromechanical exit systems. 2. References Normative References EN 1634-1 EN 1634-2 EN 1670 EN 13637 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 60529 Fire resistance and smoke control tests for doors, shutters and openable window assemblies and elements of building hardware. Part 1: Fire resistance tests for doors, shutters and openable windows Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware. Part 2: Fire resistance characterisation test for elements of building hardware Building hardware corrosion resistance requirements and test methods Electromechanical exit systems for use on escape routes requirements and test methods Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency electromagnetic field immunity test Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test Degrees of protection provided by enclosures (IP code) 3. Terms and definitions 3.1 Internal electromagnetic shear lock The electromagnetic shear lock which is designed to lock the door in the shear position. 3.2 Internal face to face fixed electromagnetic locks The face fixed electromagnetic locks are mounted under the top header rail or side frame, with the armature plate fixed to the door face. 3.3 Internal mortice face to face electromagnetic locks The mortice face to face electromagnetic locks are either morticed into a frame or a housing. 3.4 External electromagnetic magnets The electromagnetic external magnets are suitable for external applications such as vehicle and pedestrian entrance gates, barriers and doors. dhf Technical Specification 02

Technical Specification 3.5 Z & L brackets The Z & L brackets are used with face to face electromagnetic locks so that they can be fitted to inward opening doors. 3.6 L bracket A bracket used for fixing a face to face electromagnetic or outward opening doors which have a shallow frame depth. 3.7 Single action Doors that can only open in one direction and close against a fixed stop. 3.8 Double action Doors that are operable in both directions. 3.9 Safety bolts A secondary fixing which prevents the magnet fixing bolts from becoming loose or completely free whilst providing anti-tamper. 3.10 Safety straps Safety straps are a secured method of fixing the electromagnetic lock s armature plate to prevent the armature from failing from its fixed position if the fixings work loose. 3.11 Test specimen Complete full working electromagnetic lock supplied by the manufacturer ready for test. 4. General requirements 4.1 Before the commencement of any testing, the applicant shall supply detailed information about the product to be tested including the following. a) Name and address of all relevant manufacturing facilities, if different to the applicant b) All configurations for which classification is required c) Detailed drawings of all configurations d) Manufacturer s installation instructions 4.1.1 The electromagnetic lock sample shall be supplied for testing fully functioning, complete with all hardware, accessories/brackets/fixings and instructions. 4.1.2 All tests shall be conducted in accordance with the appropriate grades detailed in Clause 6 of this technical specification 4.1.3 Minimum level of IP54 is required for all magnets used for box 8 grade D in the classification code 4.2 The test requirements cover the following characteristics: 4.2.1 Category of use 4.2.2 Durability 4.2.3 Suitable for use on fire / smoke doors 4.2.4 Safety 4.2.5 Corrosion resistance 4.2.6 Security 4.2.7 Security electrical function 4.2.8 Security electrical manipulation 4.2.9 Type of device. NOTE: dhf recommend that test evidence be generated at an independent test facility with third-party accreditation. 03 dhf Technical Specification

5. Classification 5.1 Category of use Grade 3 for doors used by the public and others with little incentive to exercise care and with a chance of misuse to the door 5.2 Durability Grade 5: 50,000 cycles Grade 6: 100,000 cycles Grade 7: 200,000 cycles Grade 8: 500,000 cycles 5.3 Suitable for use on fire / smoke doors Grade 0: Not intended for use on fire doors Grade A: Suitable for use on smoke door assembly only Grade B: Suitable for use on smoke / fire door assemblies 5.4 Safety bolts & straps Grade 0: Not supplied Grade 1: Safety bolts supplied Grade 2: Straps supplied Grade 3: Safety bolts and straps supplied 5.5 Corrosion resistance Grade 1: Up to 24 hours mild resistance Grade 2: Up to 48 hours moderate resistance Grade 3: Up to 96 hours high resistance Grade 4: Up to 240 hours very high resistance 5.6 Security Holding force without additional brackets Grade 1: Holding force above 1000N (225 lbf) Grade 2: Holding force above 2000N (450 lbf) Grade 3: Holding force above 3000N (675 lbf) Grade 4: Holding force above 5000N (1125 lbf) Grade 5: Holding force above 7000N (1570 lbf) Grade 6: Holding force above 10000N (2250 lbf) 5.7 Security electrical function Grade 0: No status indication Grade 1: Status indication of the position of the electromagnetic lock either audio or visual indicator of the element Grade 2: Status indication of the position of the electromagnetic lock either audio or visual indicator of the element with additional output signal 5.8 Type of device Grade A: Internal face to face fixed electromagnetic locks Grade B: Internal mortice electromagnetic locks Grade C: Internal electromagnetic shear locks Grade D: External electromagnetic locks Cat of use Durability Fire Safety bolts & straps Corrosion Security Electro function Type of devices 3 2 B 1 3 3 1 A dhf Technical Specification 04

Technical Specification 05 dhf Technical Specification

Technical Specification 6. Test requirements and procedures 6.1 Minimum of three samples will be required for durability, holding force and corrosion testing. Locks shall be tested at the lowest nominal rated voltage. Locks shall be installed to the manufacturer s instructions. Security testing can be performed on either the durability or corrosion samples prior to these tests. 6.2 Category of use Grade 3 6.3 Durability The durability test is to identify the correct function of the electromagnetic lock, the electromagnetic lock is to be assembled in accordance with the manufacturer s fitting instructions excluding any brackets such as Z&L bracket. The durability testing is carried out on a test rig. It is performed on an apparatus that allows the armature to be moved in isolation to the magnet for example spring loaded. Test method Energize the magnet to the correct voltage (+or 10%) Attached the armature so it is secured correctly on to the face of the magnet Leave energized for a minimum of 5 seconds For type A, B and D electromagnetic locks, de-energize the magnet and remove the armature making sure there is a gap of 10mm (+ or 1mm) between magnet and armature For type C electromagnetic shear locks, de-energize the magnet and remove the armature making sure that the distance of separation is in accordance with the manufacturer s instructions Leave for a minimum of 5 seconds Re-energize the magnet and repeat the cycle 6.4 Suitable for use on fire / smoke doors The electromagnet shall be included in a full scale fire test to EN 1634-1; pass and fail criteria are given in the fire test standard. Following the full scale fire test, it could be possible to cover other designs/family members by having a fire assessment or using small scale testing to EN 1634-2. 6.5 Safety bolts and straps Safety bolts and straps shall be declared by the supplier of the electro magnet as per grading in clause 5.4. 6.6 Corrosion resistance The corrosion test shall be performed to EN 1670 for the required exposure time. Prior to the corrosion test, the security holding force shall be performed in accordance with clause 6.1.6 and the figures recorded. Whilst in the chamber, the magnet face shall be covered by the armature plate for the required duration, by securing using the specified voltage in 6.1.2. After the required exposure time, the security holding force shall be repeated and should still be within the security holding force grade previously tested. There is no visual inspection required. Electromagnetic locks that are to be corrosion tested shall have the external wiring and locating position protected for the duration of the test. dhf Technical Specification 06

6.7 Security holding force The security holding force test shall be tested on a rigid test apparatus. The electromagnetic lock is fixed by the supplied fixings to a steel section 100 mm x 50 mm x 4 mm NS RHS. If the supplied fixings are not suitable for attaching the electromagnetic lock to steel, then they may be replaced by the same number of suitable fixings of a similar or greater size. The steel section is fixed rigidly to the test bed; if necessary, the steel section may be reinforced to prevent distortion. The armature plate shall be connected to a load-cell for applying the correct holding force. The armature bracket shall be free to move whilst under load. The armature plate shall be fitted correctly (square) to the face of the magnet prior to the load being applied. Apply rated voltage to the magnet. The load is applied to the desired grade to ensure the armature, fixings and magnet housing remain secure. Repeat twice on two electromagnetic locks. Typical sample mounting methods 6.8 Security electrical function Three grades are identified as the following and are for identification only and therefore do not have a pass or fail criteria: Grade 0 No status indication Grade 1 Status indication of the position of the electromagnetic lock in the energised or non-energised state either audio or visual indicator of the element Grade 2 Status indication of the position of the electromagnetic lock in the energised or non-energised state either audio or visual indicator of the element with additional output signal 6.9 Type of device: This shall be declared by the supplier. 07 dhf Technical Specification

Technical Specification 7. Factory production control 7.1 General Factory production control (FPC) system is the permanent internal control of production exercised by the manufacturer. The aim of the FPC system is to ensure that the product characteristics are maintained within specified limits during production. The manufacturer shall set up a systematic FPC system in the form of written policies and procedures taking into account the following aspects: Product types and range of application Manufacturing processes (e.g. assembly of components purchased from external suppliers) Batch quantity The manufacturer shall appoint a person to be responsible for the FPC system in each factory. The production control requirements shall be decided by the manufacturer and shall include the following operations appropriate to the manufacturing processes: Specification and verification of raw materials and constituents Controls and tests, if any, to be carried out during manufacture in accordance with a frequency specified by the manufacturer Verifications and tests, if any, to be carried out on finished products in accordance with a frequency specified by the manufacturer Description of actions to be taken in case of non-conformity. An FPC system according to EN ISO 9001 or to similar international standards and made specific to the product is deemed to meet the FPC requirements of this Specification and verified by the manufacturer s declaration of performance. 8. Marking and labelling Example of label for packaging: 8.1 TS 010: 2016 Classification 3 8 B 0 4 6 1 B Company Name: Electromagnets - R - US Company Address: Electric Avenue, Birmingham, B1 Example of label for the product: TS 010:2016 Classification 3 8 B 0 4 6 1 B dhf Technical Specification 08

8.2 The classified electromagnetic lock shall be provided with a label fixed to the item. 8.3 The label or means of identification should be fitted so it is visible before installation. The fitting instructions will detail the characteristics of the product to which it is tested or means of identification. 9. Audit requirements 9.1 Audit tests will be performed every year and fire testing will be reviewed every 5 years. 9.2 If any part of the audit test fails, the client will be notified and discussion on possible modifications and / or further samples to be taken and tested will be agreed. 10. Installation instructions 10.1 Each electromagnet shall be supplied with full installation instructions containing information such as: maintenance, correct fixing positions, voltage requirements and correct labelling. ANNEX A A.1 Audit tests will be performed every year and fire testing will be reviewed every 5 years. Organisations ratifying this schedule dhf Alpro Door Hardware ASSA ABLOY Exova Warrington Fire Securefast Secured by Design (SBD) Permission to copy this document for internal use and promotional purposes only is automatically granted to companies holding dhf certification. Such copies are uncontrolled and this status should be identified on each copy. 09 dhf Technical Specification

dhf Technical Specification 10

Technical Specification Contact us for more information Email: info@dhfonline.org.uk Telephone: (0)1827 52337 Address: dhf 42 Heath Street, Tamworth, Staffordshire B79 7JH Copyright dhf (Door & Hardware Federation) 2017 No part of this publication may be reproduced in any form without prior permission in writing from dhf. E&OE dhf 1109 TS 010/03:16 www.dhfonline.org.uk