L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion

Similar documents
C554A Cadmium Sulfide Flame Detector

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4098A,B Deluxe Electric Heat Thermostats

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Inventory Management Guide

Single and Multi-Function Aquastat Controllers

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

T4398A,B High Performance Electric Heat Thermostats

C7232A,B Sensor and Controller

Custom Duct Heaters. Special Applications

T834C Heating-Cooling Thermostat

Standard Duct Heaters Open Coil

Installation, Operation, and Troubleshooting Instructions

The T6140A,B Remote Bulb Temperature Controller

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Installation Instructions

Custom Duct Heaters. Special Applications

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

THERMOSTATS THERMOSTATS HEATING AND COOLING

D896 Automatic Vent Damper

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Installation Instructions

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Installation & Operation Instructions

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Thermostat Catalog 2004

MJ35 Parts List. Accessories. Burner Components. Cabinetry. Thermostats. Filtration. Frypots. Basket Lift. Square Drain Components

Heating Maintenance and Repair

T6984F,G Electronic Floating Control Thermostats

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Peerless Boilers. Series MI. Residential Gas Boilers

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Zone Control Panels. ZoZ one Product Catalog Page 3 ED3 SMZ4SW SMZAC SMZ3SW JTZHP

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

X-593 SOLID FUEL HEATING QUESTIONNAIRE

Heatrix Electric Duct Heater HXOB Installation Instructions

CADDY CORPORATION. Utility Distribution Systems

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

C7004B Flame Rod Holder

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

Installation & Operation Instructions

PARTS MANUAL Model Numbers:

Installation Instructions

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

T7984 A,B,C Electronic Modulating Control Thermostats

CR Series Command Relays

T7079A,B Solid State Remote Temperature Controllers

INTELLI-VAC 14 INTELLI-VAC 18

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

FDF Foam Pump Controllers Features

CR7075 Two-Stage Lighting Controller

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Installation Instructions

LMR Electric Fire Pump Controllers Features

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

7800 SERIES EC7885A/RM7885A Relay Module

Drying Tumblers Stacked 30 Pound Capacity

LGB Gas fired boiler

C6097A,B Pressure Switches

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

Modular Heating & Ventilating Unit Model IGX-HV

59T, 66T Series Electric Water Heater Controls

FEATURES AND BENEFITS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

water to water heat pumps

HRV Vertical Unit Ventilators

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

24 VAC SYSTEM CONTROL KIT

LMR Electric Fire Pump Controllers Features

Thermostats. Thermostats

Powers Controls Low Temperature Detection Thermostat

Manual For Reznor Heater

SECTION WATER-SOURCE UNITARY HEAT PUMPS

INSTALLATION INSTRUCTIONS

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Installation Instructions

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Installation Supplement

Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Gas and Electric Convection Ovens

ECOVENT: IT S MORE THAN A VENT. It s a climate control mastermind

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Transcription:

HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House Air Quality HVAC Zoning Residential Combustion > Contactors > Defrost Controls > Electronic Timer Boards > Flue Dampers > Pilots, Thermocouples and Ignition > Gas Ignition Controls > Relays and Controls > L4064 L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion Locate Distributors Product Specifications Literature and Documents Overview For control of high limit and fan motor in all types of forced air heating systems. > Gas Valves for Residential > Hydronic Heating > Oil Heating Valves > Oil Primary Controls > Pressure Switches > Relays and Controls > Transformers EnviraCOM Communications Water Control Training Materials & Product Literature Features Three wiring terminal options available for easy installation: Push-in receptacles for stripped wire. Female receptacles for 1/4 in. male flag connectors. Field add-on screw terminals. Controls adapt to many competitive mounting holes in replacement applications. Available in a variety of fan and high limit setting ranges. L4064B,W models have manual fan switch that overrides fan control to keep fan running continuously. SUPER TRADELINE models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse. Product Accessories 129250AA - Double wing mounting flange assembly for Fan and Limit Control L4064 Tradeline Catalog Printed Version (114 MB) Tradeline Catalog CD-ROM version (50 MB) Product Specifications Back To Top Description Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion ACI Contractor Residential Contractor Distributor Application (in.) (mm) Fan-on Fan-on Fan-off Fan-off High Limit Stop (F) Fan-on Stop (F) Fan-off Stop (F) Forced warm air heating systems 100 F to 250 F 38 C to 121 C 11 1/2 in. 292 mm 65 F to 215 F 18 C to 102 C 50 F to 200 F 10 C to 93 C 200 F 125 F 100 F

Switching Action (F) (C) Temperature (F) Temperature (C) Mounting Dimensions (in.) Dimensions (mm) Approvals, Underwriters Laboratories Inc Approvals, Canadian Standards Association Comments Tradeline Value Fan switch makes and high limit switch breaks on temperature rise. 14 A @ 120 Vac 7 A @ 240 Vac 84 A @ 120 Vac 42 A @ 240 Vac 4 A @ 240 Vac 8 A @ 120 Vac 24 A @ 240 Vac 48 A @ 120 Vac 2 A @ 24 Vac 0.25 A @ 0.25 to 12 Vdc -40 F to +190 F -40 C to +88 C High limit 25 F High limit 14 C Switch: 190F; Sensing Element: 350 F Switch: 88 C; Sensing Element: 177 C Surface 4 9/32 in. high x 3 in. wide x 1 19/32 in. deep 109 mm high x 76 mm wide x 40 mm deep Listed File MP466, Guide MBPR Certified: File No. LR1622 Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop set at 200F (93 C). With manual fan switch. Small case and cover. Replaces L4064A,B,E. Tradeline

HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House Air Quality HVAC Zoning Residential Combustion > Contactors > Defrost Controls > Electronic Timer Boards > Flue Dampers > Pilots, Thermocouples and Ignition > Gas Ignition Controls > Relays and Controls > L4064 L4064B2228 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 5 in. insertion Locate Distributors Product Specifications Literature and Documents Overview For control of high limit and fan motor in all types of forced air heating systems. > Gas Valves for Residential > Hydronic Heating > Oil Heating Valves > Oil Primary Controls > Pressure Switches > Relays and Controls > Transformers EnviraCOM Communications Water Control Training Materials & Product Literature Features Three wiring terminal options available for easy installation: Push-in receptacles for stripped wire. Female receptacles for 1/4 in. male flag connectors. Field add-on screw terminals. Controls adapt to many competitive mounting holes in replacement applications. Available in a variety of fan and high limit setting ranges. L4064B,W models have manual fan switch that overrides fan control to keep fan running continuously. SUPER TRADELINE models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse. Product Accessories 129250AA - Double wing mounting flange assembly for Fan and Limit Control L4064 Tradeline Catalog Printed Version (114 MB) Tradeline Catalog CD-ROM version (50 MB) Product Specifications Back To Top Description Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 5 in. insertion ACI Contractor Residential Contractor Distributor Application (in.) (mm) Fan-on Fan-on Fan-off Fan-off High Limit Stop (F) Fan-on Stop (F) Fan-off Stop (F) Forced warm air heating systems 100 F to 250 F 38 C to 121 C 5 in. 127 mm 65 F to 215 F 18 C to 102 C 50 F to 200 F 10 C to 93 C 200 F 125 F 100 F

Switching Action (F) (C) Temperature (F) Temperature (C) Mounting Dimensions (in.) Dimensions (mm) Approvals, Underwriters Laboratories Inc Approvals, Canadian Standards Association Comments Tradeline Value Fan switch makes and high limit switch breaks on temperature rise. 14 A @ 120 Vac 7 A @ 240 Vac 84 A @ 120 Vac 42 A @ 240 Vac 4 A @ 240 Vac 8 A @ 120 Vac 24 A @ 240 Vac 48 A @ 120 Vac 2 A @ 24 Vac 0.25 A @ 0.25 to 12 Vdc -40 F to +190 F -40 C to +88 C High limit 25 F High limit 14 C Switch: 190F; Sensing Element: 350 F Switch: 88 C; Sensing Element: 177 C Surface 4 9/32 in. high x 3 in. wide x 1 19/32 in. deep 109 mm high x 76 mm wide x 40 mm deep Listed File MP466, Guide MBPR Certified: File No. LR1622 Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop set at 200F (93 C). With manual fan switch. Small case and cover. Replaces L4064A,B,E. Tradeline

HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House Air Quality HVAC Zoning Residential Combustion > Contactors > Defrost Controls > Electronic Timer Boards > Flue Dampers > Pilots, Thermocouples and Ignition > Gas Ignition Controls > Relays and Controls > L4064 L4064B2236 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 8 in. insertion Locate Distributors Product Specifications Literature and Documents Overview For control of high limit and fan motor in all types of forced air heating systems. > Gas Valves for Residential > Hydronic Heating > Oil Heating Valves > Oil Primary Controls > Pressure Switches > Relays and Controls > Transformers EnviraCOM Communications Water Control Training Materials & Product Literature Features Three wiring terminal options available for easy installation: Push-in receptacles for stripped wire. Female receptacles for 1/4 in. male flag connectors. Field add-on screw terminals. Controls adapt to many competitive mounting holes in replacement applications. Available in a variety of fan and high limit setting ranges. L4064B,W models have manual fan switch that overrides fan control to keep fan running continuously. SUPER TRADELINE models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse. Product Accessories 129250AA - Double wing mounting flange assembly for Fan and Limit Control L4064 Tradeline Catalog Printed Version (114 MB) Tradeline Catalog CD-ROM version (50 MB) Product Specifications Back To Top Description Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 8 in. insertion ACI Contractor Residential Contractor Distributor Application (in.) (mm) Fan-on Fan-on Fan-off Fan-off High Limit Stop (F) Fan-on Stop (F) Fan-off Stop (F) Forced warm air heating systems 100 F to 250 F 38 C to 121 C 8 in. 203 mm 65 F to 215 F 18 C to 102 C 50 F to 200 F 10 C to 93 C 200 F 125 F 100 F

Switching Action (F) (C) Temperature (F) Temperature (C) Mounting Dimensions (in.) Dimensions (mm) Approvals, Underwriters Laboratories Inc Approvals, Canadian Standards Association Comments Tradeline Value Fan switch makes and high limit switch breaks on temperature rise. 14 A @ 120 Vac 7 A @ 240 Vac 84 A @ 120 Vac 42 A @ 240 Vac 4 A @ 240 Vac 8 A @ 120 Vac 24 A @ 240 Vac 48 A @ 120 Vac 2 A @ 24 Vac 0.25 A @ 0.25 to 12 Vdc -40 F to +190 F -40 C to +88 C High limit 25 F High limit 14 C Switch: 190F; Sensing Element: 350 F Switch: 88 C; Sensing Element: 177 C Surface 4 9/32 in. high x 3 in. wide x 1 19/32 in. deep 109 mm high x 76 mm wide x 40 mm deep Listed File MP466, Guide MBPR Certified: File No. LR1622 Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop set at 200F (93 C). With manual fan switch. Small case and cover. Replaces L4064A,B,E. Tradeline