Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Similar documents
NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

V.I.P. Series -86 C Ultra Temperature Freezers. The Ideal 86 C, Preservation Environment in Capacities from 12 cu.ft. to 26 cu.ft.

Thermo Scientific HERAfreeze Freezers Solutions for safe sample storage

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

V.I.P. Series -86 C Ultra Low Freezers

Serie V.I.P. Congelatori -86 C F

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Laboratory & Pharmacy Refrigerators

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers. -40 C and -86 C. Green Line

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Thermo Scientific Revco Laboratory Refrigerators and Freezers

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Biomedical Freezer 37 38

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

ULTRA.GUARD ultra low temperature freezer

Thermo Scientific Harris Freezers. > Total sample protection, complete peace of mind

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Protection, safety, reliability. And more.

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Stability & Shelf Life

Refrigerators. Upright Blood Bank. i.series Horizon Series

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

Installation and Operation Manual. Thermo Scientific Revco Chest and Upright Ultra-Low Temperature Freezers

ULTRA LOW TEMPERATURE FREEZER. User Manual

-86 C Ultra-Low Freezers. How It s Made. Matters

more than M A N U FA C T U R I N G F R E E Z E R S U LT

TSX Series High-Performance Refrigerators and Freezers

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Freezers. Laboratory & Plasma. i.series Horizon Series

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Keeping your samples safe

Cardinal Health Refrigerators and Freezers. Keeping your samples safe

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

Full Adjustable Shelves

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

REFRIGERATOR M E D I C A L.

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

Ultra-Low and Cryogenic Solution

Upright Chromatography Refrigerators

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

-86 C Ultra-Low Freezers

Setting the Benchmark

DOUBLE DOOR FREEZER.

Ultra-Low Temperature Chest Freezers

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER

Platelet Storage. i.series Horizon Series

TSX Series High-Performance Refrigerators and Freezers

TEMPERATURE FREEZERS -90

-86ºC-Freezers. Ultra-low temperature upright freezer -86ºC MDF-U5086W MDF-U6086S MDF-U5186S MDF-U4086S MDF-U3086S MDF-U2086S MDF-U5086W

Platelet Storage. i.series Horizon Series

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

-1050C FREEZER NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Freeze Dry Systems and Accessories

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

-86 Ultra Low Temperature Freezer

Freeze Dry Systems and Accessories

Ultra-Low and Cryogenic Solutions

VWR Laboratory Refrigerators and Freezers

Undercounter Refrigerator Operation Manual

REVCO MECHANICAL CRYOGENIC FREEZER

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ULT Freezer Model 5700 Series Chest Freezer Manual Number Rev. 15

Ultra-Low Freezer Operation Manual

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

our obsession your samples Thermo Scientific Revco High-Performance Laboratory Refrigerators and Freezers

Thermo Fisher Scientific ULT Clinic. Peter Diebold Cold Storage Specialist

NEW Cold Storage Offers that deliver the right cold storage solutions at the right time. That s smart

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

CLIMATRON GROWTH CABINETS

Refrigerators and freezers Research and laboratory 2018

Ultra-Low Temperature Freezer powered by Smart-Lab TM System

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

Model 900 Series -86C Ultra Low Temperature Freezer Operating and Maintenance Manual Rev. 6

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Laboratory refrigerators and freezers

FreeZone 2.5 Liter Benchtop Freeze Dryers

Model 700 Series Forma ULT Chest Freezer Operating and Maintenance Manual Rev. 4

Plant Growth Chamber MPGR14

Reach-In. PLanT GROWTh. Reach-In

Controlled Environment Equipment Solutions for the Lab

Transcription:

Ultra-Low Temperature Freezers Series Microprocessor Control Basic Series Solid-State Electronic Control

2 Ultra-Low Freezers Queue Advantage ultra-low temperature freezers create stable -86 C, -50 C and -40 C storage conditions for long-term preservation of biologicals and other critical materials. All models built to meet or exceed UL, CUL, and CE criteria for safety and performance. Each model is designed with special features to provide a high level of performance and dependability such as: Tamper-resistant microprocessor controls with touchpad function to resist tampering. Extra-large multiple function digital displays that are easy to read. Alarm/monitor systems for protection. Powerful, quiet-running refrigeration systems. A wide selection of chest and upright cabinets feature interior volumes ranging from 90 to 691 liters. Feature Summary -86 C chest or upright Advantage Air-cooled cascade refrigeration system 1 HP compressors (2) Key-operated on/off switch Microprocessor controller Alarm/monitoring system Silent witness alert Low voltage alert Automatic voltage boost Built-in surge suppressor RS-232 data port Stainless steel interior -40 C chest Air-cooled cascade refrigeration system 1 HP compressor (1) Key-operated on/off switch Microprocessor controller Alarm/monitoring system Silent witness alert Low voltage alert Automatic voltage boost Built-in surge suppressor RS-232 data port Stainless steel interior -40 C upright Air-cooled cascade refrigeration system 1 HP compressor (1) Key-operated on/off switch Microprocessor controller Alarm/monitoring system Silent witness alert Low voltage alert Automatic voltage boost Built-in surge suppressor RS-232 data port Stainless steel interior Integrated door handle and latch assembly allows for easy one-hand operation. Door latch includes key lock and provision for padlock. Standard on all Advantage and Basic upright models. Advantage upright freezers are available in four sizes. Shown with chart recorder. Pressure Equalization Port Advantage chest freezers feature low profile designs for easy access. Shown with chart recorder. Pressure equalization port controls amount of atmospheric air allowed into the storage chamber after door openings. Standard on all Advantage and Basic upright freezers. Combats vacuum created by pressure differential upon door closing. Allows cabinet re-entry within 30 seconds of door closing. Microprocessor Controls The Advantage microprocessor controller delivers information on available line voltage, battery reserve and charging capacity, setpoints, airflow across the filter and more. Internal probes and sensors accumulate and compare numbers on temperatures, pressures, voltage and amperage. An RS-232 data port includes software to log information onto a PC.

The Q main power and alarm system are controlled by a single, Touchpad alarm test verifies readiness; the alarm test three-position key switch for setpoint security. Parameters simulates cabinet warm-up. cannot be changed without key access. Low battery indicator with digital display advises when Extra large digital temperature display with readout in 1 C to replace battery. increments; the display indicates both setpoint and actual A low voltage indicator warns of insufficient line voltage temperature. to the freezer. Clean filter indicator advises when to clean condenser Remote alarm contacts for connection to an exterior intake filter. monitoring system. Silent witness alert supervises freezer operation, scans data points from internal and ambient sources, and warns of both current problems and problems which have occurred and self-corrected while the freezer was unattended. Alarm Function Touchpad controls are tamper-resistant. A SELECT mode allows easy programming of setpoint. Built-in voltage boost system helps protect refrigeration components by automatically compensating for insufficient line voltage. Alarm/Monitor System The built-in safety alarm system has an automatic, continuous charging battery backup to provide full function performance in case of a power failure. Tamper-proof key switch locks alarm in ON or OFF mode. Independent high and low alarm setpoints are adjustable in 1 C increments. Alarm activates an audible and visual warning on power failure or temperature deviation. If the freezer is in alarm (warm, cold, low voltage, power failure) If the problem has corrected itself In a temperature deviation When the alarm reset button is pressed the warning light flashes quickly; temperature display also flashes during a power failure. the warning light flashes slowly. A self-corrected temperature alarm alternates flashing between the temperature failure alarm and warm or cold alarm. the silent witness alert holds the warmest temperature in memory, ready for recall by simultaneously pressing the cabinet temperature and warm alarm setpoint buttons. the slow flash is stopped and the memory is cleared for continuous monitoring. Touchpad controls are tamper-proof. Large-scale,easy-to-read LED display provides direct readout of operating temperature, setpoint, high and low alarm parameters, plus line voltage and % battery capacity. Indicator lights show status of all operating systems. Clean filter indicator light reminds you to wash filter to protect condenser from dust buildup; no tools required. Single key switch controls main power and alarm ON/OFF functions. Push-button alarm test physically warms probe to simulate an actual alarm condition; no door or lid opening is required. Data entry pads for operating temperature, overtemperature and undertemperature parameters. Low battery indicator advises when to replace long-life, self-charging alarm system battery. Push-button displays % battery capacity on digital readout. Low voltage alert warns of low voltage; push-button displays line voltage on digital readout. A voltage booster will protect refrigeration system during brown-out periods. 3

Basic Ultra-Low Freezers Queue Basic ultra-low freezers are designed for-86 C storage, processing and testing. The Basic solid-state electronic control system allows simple, accurate control with a pre-set alarm. Basic Solid-State Electronic Control System The Basic control panel is designed primarily for temperature setpoint and display with the added advantage of a pre-set alarm. Overtemperature alarm with audible warning is factory pre-set at 90% of selected operating temperature setpoint. Key-operated on/off switch controls main power; the freezer cannot be turned off unless the key is inserted. Temperature control adjustment is recessed to prevent tampering. Large, easy-to-read digital display indicates both setpoint and actual temperature at the push of a button. Built-in voltage boost system helps protect refrigeration components by automatically compensating for insufficient line voltage. Simplified controls include a key-operated on/off switch and bright LED temperature display. Cascade Refrigeration System Air-cooled refrigeration systems feature CFC-free refrigerants and are engineered to maintain design temperatures in 32 C ambient setting. The -86 C refrigeration system includes two 1 HP compressors; -50 C and -40 C models use a single compressor. A washable condenser intake filter maintains peak operating efficiency. The filter is easy to clean; no tools are required for removal. A noise suppression design minimizes normal operating sound. Chest Models The low profile chest design provides easier access to the inventory system. The fully insulated, counterbalanced lid with keyed lid lock improves security (key lock not available on 90 liter model, padlock provision provided). Independent, double-seal gaskets with sub-lids reduce frost buildup and provide additional protection. A full length lid handle is. Model QBF-1385, Basic -86 C Upright Freezer, 379 liter capacity Model QBF-1490, -86 C Chest Freezer, 388 liter capacity General Cabinet Design, and Basic Series Upright Models Space-saving upright cabinets are available in four sizes for most efficient use of floor space. Low height cabinets (197 cm including casters) allow for easy installation and movement of freezer through doors, hallways and lifts. The insulated outer door with keyed lock forms a positive seal for added inventory security (2 keys provided). Integrated door and latch assembly allows for easy right-or left-hand operation. Padlock provision is on all upright models. Five insulated inner doors minimize cold air loss during door openings. Four stainless steel interior shelves make efficient use of interior space (three are adjustable, one is fixed). Cabinet Construction Chest and upright cabinets are insulated with a minimum of 12.5 cm foamed-in-place urethane insulation to protect the stored product from high ambient temperatures. The 100% steel cabinet includes a high-impact epoxy finish for easy cleaning. A 25 mm diameter access port is pre-positioned in each cabinet. High-strength casters are included for easy installation. 4

Ultra-Low Temperature Freezers, Microprocessor Control Model No. Capacity Amps/ Interior Dimensions Exterior Dimensions* Ship Weight Electrical, 1Ø Liters Breaker W x F-B x H (cm) W x F-B x H (cm) kg Advantage -86 C Chest Models, Temperature Range -40 C to -86 C QLT-385V 90 230V, 50Hz 7.2/15 42 x 42 x 47 74 x 69 x 116 193 QLT-785V 195 230V, 50Hz 7.2/15 60x 49 x 68 124 x 74 x 104 277 QLT-1085V 292 230V, 50Hz 10.7/15 90 x 49 x 68 154 x 74 x 104 303 QLT-1485V 388 230V, 50Hz 10.7/15 120 x 49 x 68 183 x 74 x 104 335 QLT-1785V 484 230V, 50Hz 10.7/15 150 x 49 x 68 213 x 74 x 104 378 QLT-2085V 581 230V, 50Hz 10.7/15 179 x 49 x 68 243 x 74 x 104 420 Advantage -86 C Upright Models, Temperature Range -50 C to -86 C QLT-1385V 379 230V, 50Hz 10.7/15 60 x 50 x 129 86 x 76 x 197 261 QLT-1885V 487 230V, 50Hz 10.7/15 60 x 64 x 129 86 x 90 x 197 277 QLT-2185V 572 230V, 50Hz 10.7/15 73 x 62 x 129 98 x 88 x 197 295 QLT-2585V 691 230V, 50Hz 10.7/15 88 x 62 x 129 113 x 88 x 197 313 Advantage -40 C Chest Models, Temperature Range -10 C to -40 C QLT-350V 90 230V, 50Hz 7.2/15 42 x 42 x 47 74 x 69 x 116 193 QLT-750V 195 230V, 50Hz 7.2/15 60 x 49 x 68 124 x 74 x 104 277 QLT-1050V 292 230V, 50Hz 10.7/15 90 x 49 x 68 154 x 74 x 104 303 QLT-1450V 388 230V, 50Hz 10.7/15 120 x 49 x 68 183 x 74 x 104 335 QLT-1750V 484 230V, 50Hz 10.7/15 150 x 49 x 68 213 x 74 x 104 378 QLT-2050V 581 230V, 50Hz 10.7/15 179 x 49 x 68 243 x 74 x 104 420 Advantage -40 C Upright Models, Temperature Range -10 C to -40 C QLT-1340V 379 230V, 50Hz 10.7/15 60 x 50 x 129 86 x 76 x 197 261 QLT-1740V 487 230V, 50Hz 10.7/15 60 x 64 x 129 86 x 90 x 197 277 QLT-2140V 572 230V, 50Hz 10.7/15 73 x 62 x 129 98 x 88 x 197 295 QLT-2540V 691 230V, 50Hz 10.7/15 88 x 62 x 129 113 x 88 x 197 313 Basic Ultra-Low Temperature Freezers, Solid State Electronic Contol System Basic -86 C Chest Models, Temperature Range -40 C to -86 C QBF-390V 90 230V, 50Hz 7.2/15 42 x 42 x 47 74 x 69 x 116 193 QBF-790V 195 230V, 50Hz 7.2/15 60 x 49 x 68 124 x 74 x 104 277 QBF-1090V 292 230V, 50Hz 10.7/15 90 x 49 x 68 154 x 74 x 104 303 QBF-1490V 388 230V, 50Hz 10.7/15 120 x 49 x 68 183 x 74 x 104 335 QBF-1790V 484 230V, 50Hz 10.7/15 150 x 49 x 68 213 x 74 x 104 378 QBF-2090V 581 230V, 50Hz 10.7/15 179 x 49 x 68 243 x 74 x 104 420 Basic -86 C Upright Models, Temperature Range -50 C to -86 C QBF-1385V 379 230V, 50Hz 10.7/15 60 x 50 x 129 86 x 76 x 197 261 QBF-1785V 487 230V, 50Hz 10.7/15 60 x 64 x 129 86 x 90 x 197 277 QBF-2185V 572 230V, 50Hz 10.7/15 73 x 62 x 129 98 x 88 x 197 295 QBF-2585V 691 230V, 50Hz 10.7/15 88 x 62 x 129 113 x 88 x 197 313 *Exterior dimensions do not include latch assembly and hinges. Allow approximately 8 cm for width. Queue ultra-low freezers feature the latest refrigeration technology, including specially designed (1) HP Copeland compressors and Suva 95 CFC-free refrigerants, scientifically matched and life-tested for operation in rugged laboratory environments. Performance Data and Validation Contact Queue for detailed performance information such as pull-down, warm-up, heat rejection, power consumption, sound levels and model-specific performance characteristics. Queue can also provide validation testing of product in advance of shipment to accelerate inhouse IQ and OQ programs. 5

Accessories Upright Freezer Extra Shelves For 379 liter models...catalog No. 6667 For 487 liter models...catalog No. 6668 For 572 liter models...catalog No. 6669 For 691 liter models...catalog No. 6670 Inventory Boxes and Grid Dividers Fiberboard boxes and dividers are ordered separately and packaged in lots of twelve. Boxes include covers. Fiberboard Boxes 5 cm high...catalog No. 5954 7.5 cm high...catalog No. 5956 Grid Dividers 100 cell...catalog No. 5958 49 cell...catalog No. 5959 64 cell...catalog No. 5960 81 cell...catalog No. 6212 Temperature Recorders and Chart Paper For a permanent record of chamber operating temperature. Choose from built-in (specify when ordering freezer) or free-standing. The free-standing recorder is mounted in a self-contained housing. Built-in, 15 cm chart, range -40 C to -90 C, factory installed, specify when ordering freezer....catalog No. 6183-6 Free-standing, 15 cm chart, range -40 C to -90 C, customer installed...catalog No. 6383-6 Replacement Chart Paper, 7-day scale, range -115 C to +50 C, package of 50 charts...catalog No. 6185 Backup System Automatically injects liquid nitrogen or liquid CO 2 when cabinet temperature rises above pre-selected temperature. Includes solenoid valve, injection tube and control assembly. Requires liquid nitrogen or liquid CO 2 supply to cabinet (by customer). Specify freezer model number and voltage when ordering. CO 2 backup, free-standing, customer installed...catalog No. 6593 LN 2 backup, free-standing, customer installed....catalog No. 6214 Inventory Rack Capacity Chart, Chest and Upright Models Volume (Liters) 90 195 292 388 484 581 379 487 572 691 Catalog No. and Description chest chest chest chest chest chest upright upright upright upright Cabinet Capacity 5972, full rack, (7) 5 cm boxes 9 5973, full rack, (5) 7.5 cm boxes 9 5978, full rack, (11) 5 cm boxes 12 18 24 30 36 6096, full rack, (8) 7.5 cm boxes 12 18 24 30 36 6230, half rack, (6) 5 cm boxes 24 36 48 60 72 6231, half rack, (4) 7.5 cm boxes 24 36 48 60 72 6112-1, (12) 5 cm or (9) 7.5 cm boxes 20 6113-1, (12) 5 cm or (9) 7.5 cm boxes 20 25 30 6733, microtiter plate rack (66) 20 25 30 6734, microtiter plate rack (44) 20 Queue Laboratory Systems International G.R. Instruments B.V. Voswijk 7 3961 NH Wijk Bij Duurstede, The Netherlands Tel. 31-343-520284 Fax 31-343-512134 Queue 275 Aiken Road, Asheville, NC 28804 USA Toll-Free USA 800-221-4201 Fax 828-658-0363 www.harrisphq.com e-mail sales@harrisphq.com Q302REV1 (QUE31245) 8/01 5M 2001 Specifications subject to change. All brand and product names are trademarks or registered trademarks of their respective holders.