Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

Similar documents
Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

Automated Pressure Steam Sterilizer. Operating Instructions

Service Manual. FILE No.HMRSM

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-940/940F. Picture:

FOB NINGBO PORT PRICE: 29,000USD

LEVEL SENSORS & FLOAT SWITCHES

AIR CONDITIONER WITHOUT OUTDOOR UNIT

PolyBox TM. Edition II. Operation Manual

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

brass material mould. 500USD (2 pcs) Baby safety swab 500USD (2 pcs) Cosmetic swab brass material mould. 500USD (2 pcs) Cosmetic swab

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator

Prof. Dr. Li Ming. Refrigeration technology about solar adsorption, absorption and Photovoltaic

Hitachi Highly. Spezifikation Manual

HUMIDIFIER SERVICE MANUAL

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

Liebert DM Chilled Water Series User Manual. Precision Cooling For Business-Critical Continuity

GAO THERMAL CONTROL TECHNOLOGY CO.,LTD

RAS-DX18HDK/RAC-DX18HDK

WAT E R S O U R C E H E AT P U M P S

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

Air cooled screw chiller Technical service manual (LSBLGW***/C

Modular Air Cooled Chiller/Heat Pump

Adaptibility Analysis of nzeb and Passivhaus in Mixture Climates of China

Heater-Controller Package manual

SUNSTAR 单片机专用电路 TEL: FAX: Features 6 Digit 6 Function LCD Alarm Watch with RGB LE

Premium Desoldering station with Electric Pump Ref. DIS-D

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

PMAC202 Branch Circuit Power Meter User Manual V1.0

Hot Air Station without Extractor desk Ref. JTSE-QA

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

Shaking Peltier Device

Repair Station Manual. Ameco Components Repair Capability List. Ameco 部件修理能力清单. Document No.: QM 005/95 FAA FAA

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-68/68A/118/118A. Picture:

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

Kitchen Exhaust Duct (KED) Requirements

Deep Freezer-upright

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

Dehumidifier User Manual. (For the series of DP40~DP70)

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Rosemount 848T High Density Temperature Measurement Family

TOYOLAC PC//ABS Alloy PX10

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Application of Distributed Fiber Optic Sensing Technology in the Transportation Engineering Monitoring

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Flammable and Toxic Gas Detection

R-S32EPH R-S32EPHL

Compressor Built-in Model

Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr

compact Bagless Cyclonic Vacuum Cleaner IMPORTANT: Read carefully before assembly and use.

Service Manual FILE. No.HMRSM Lined. Ice

Manual Zhengzhou Winsen Electronics Technology Co., Ltd

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Indesit,CVTAA 55 NF UK, CVTAA 55 NF UK S( CE-BCD275W-S, ) 英文说明书 版本号 REV.NO. 重量 (g) WEIGHT

Prospects and challenges for sustainable urbanization in China

Gas Pipeline Locating Leak detection and Safety Assessment

PAC-10P PAC-15P. 移動座地式冷暖空調 Portable Reverse Cycle Air Conditioner 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

Contents TERI. Part I Background. Part II Introduction of Research on Flammability of Lower GWP Refrigerantds by TERI.

公司願景 業務項目 我們的願景是能為您帶來更加 健康 舒適 便利 的生活環境 水的控制專家 晴立實業 創立於 1993 年 十幾年來致力於排水器及週邊產品之研究與開發 多年來的創新及研發成果獲得多項產品專利, 深受各界的肯定, 於業界亦趨領導地位 為了服務客戶長久以來的支持,

Always there to help you

CONTENT. I. Product Description.2. II. Application Areas of Pain Spraying/Baking Booth.2. III. Equipment Constituents..2. V. Operating Principle.

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

Register your product and get support at 在以下网站注册并获得支持

Fire Protection with High Pressure Water Mist in the Tobacco Warehouse

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

AIR COOLER. Model: MAC-215F. Please read this manual carefully before running this air cooler and save it for reference.

Controller for Constant Temp. and Humidity Unit

Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

CW-5000/5200 Series Industrial Chiller maintenance manual

DEHUMIDIFYING DRYER DMZ 2-40~120U. Instruction Manual

Personal Care Appliances in Sweden

KMART Corrective Action Plan

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Dehumidifier User Manual

Parts introduction FRONT BACK

Personal Care Appliances in Thailand

Combined Refrigerator and Freezer Operation Manual

USER MANUAL KBU-50 /120 /170 TWO-TEMP ZONES MODELS

LATEST HEAT PUMP TECHNOLOGIES IN JAPAN. Waseda University Kiyoshi Saito

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Medical Refrigerator

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator

MAC-D R410A Series Air-cooled Modular Chiller/Heat Pump

SC8130S /SC8136S /SC8130W /SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW SC8130S /SC8136S /SC8130W/SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW

Miele Service Certificate

Transcription:

Internal training document for Haier service providers. External disclosure is forbidden Service Manual Solar Direct Drive Vaccine Refrigerator / Freezer Model :HTC-40/110; HTCD-90 Pictures : HTC-40/110 HTCD-90

Contents After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator I. Product model coding explanation... 3 II. Product appearance and components... 3 III. Unit description... 5 IV. Electric parts and wiring diagram... 5 V. Parameter of refrigerating system and spare parts... 7 VI. Parts layout... 9 VII. Operation guide... 16 VIII. Indications and alarm functions... 20 IX. Precautions for installation and commissioning... 21 X. Replacement guide for key components... 22 XI. Transportation conditions, installation environment and package disassembly... 25 XII. Test curve... 26 2

I. Product model coding explanation H(Haier)T(solar)C(refrigerator)D(freezer)-90(volume: about 90L) II. Product appearance and components HTC-40/110: Handle Door Water tank cover Inner door Basket Lifting handle Grilling Temperature displayer Hinge Electric cabinet Power switch Fan Compressor Temperature controller Condenser 3

HTCD-90 Inner door for refrigerator Door handle Refrigerating chamber Water tank cover Door Inner door for freezer Basket Grilling Freezing chamber Lifting handle Temperature displayer Hinge Fan Electric cabinet temperature controller Compressor for freezer Condenser for refrigerator Compressor refrigerator for Condenser for freezer 4

III. Unit description After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator Parameter HTC-40 HTC-110 HTCD-90 Ambient temperature ( ) +5~+43 +5~+43 +5~+43 Temperature range of refrigerator ( ) +2~+8 +2~+8 +2~+8 Temperature range of freezer ( ) - <-5 <-5 Gross volume(l) 40 110 Effective volume of vaccine (L) 22.5 75 75 (without basket) 59 59 (with basket) Freezing volume for ice pack (L) - - 32 Freezing capacity for ice pack (kg/24h) 58 - - 2.43 Storage volume for ice pack (kg) - - 12.52 Refrigerant R600a(g) 45 45 2x45 Voltage(DCV) 24 24 24 Rated power(w) 115 105 160 Auxiliary (Available/Unavailable) battery Exterior dimension(w D H)( mm ) Unavailable Unavailable Unavailable 788*654*875 1128*654*875 1128*654*875 Weight(kg) 55 69 83 Power of solar panel(w) 2*180 2*180 4*180 IV. Electric parts and wiring diagram HTC-40/110,HTCD-90: No. 1 2 3 Material number 0274000351 Description Quantity Main technical parameter Remark Condensation fan 0270400367 Heater wire 0274000352 Electric temperature controller 1 DC 10V~DC 56V, DC power supply DC 10V~DC 56V, rated Power: 2.6W, revolving speed 2200 1 Rated working voltage:30v, power :28W Working voltage range: DC 10V-DC 45V Working power range:3.1w-63.3w 1 Working voltage: DC 8V-DC 60V 4 0274000354 Switch 1 AC 240V/DC 60V,50/60HZ,20A Rated specification: AC 240V/DC 60V, 50/60HZ, 20A 5

5 0274000355 Fuse holder 1 DC 32V/40A Rated voltage/current: DC 32V/40A DC 8V~DC 45V Working voltage range: DC 8V-DC 45V 7 0274000357 Temperature displayer 1 Temperature range:-50.0 to 70.0, resolution: 0.1 and electric current: less than 0.2A HTCD-90 Two for HTCD-90 HTC-40 HTC-110: Temperature sensor Refrigerating sensor Ice layer sensor Refrigerating compressor Heating Fan Electronic double-way temperature controller Fuse Capacitor Power module Heater strip Double-thro w switch PV input (+) PV output (-) HTCD-90: 6

Temperature sensor Freezing sensor Refrigerating sensor Ice layer sensor Freezing compressor Heating Electronic double-way temperature controller Refrigerating compressor Fuse Capacitor Fan Power module Double-thr ow switch PV input (+) PV output (-) Heater strip V. Parameter of refrigerating system and spare parts HTC-40: No. 1 2 3 Material number 0274000118 Compressor 0270700427 Evaporator 0270700425 Description Quantity Main technical parameter Wire and tube condenser 1 BD-35K (accessories: 101N0400, 10-45Vdc) 1 Blow-up type, flow rate of capillary: 5L/min 1 +Φ1.5 electrophoresis and rust-resistance steel wire of Φ6 0.71 steel tube 4 0074180006 Dry filter 1 10g 5 0070301474 Refrigerant 45g R600a Remark 6 0270700429 Heat pipe 2*18g R134a refrigerant 18g Upper layer 7 0270700429A Heat pipe 2*18g R134a refrigerant 18g Lower layer 7

HTC-110: After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator No. 1 2 3 Material number 0274000118 Compressor 0270700427 Evaporator 0270700421 Description Quantity Main technical parameter Remark Wire and tube condenser 1 BD-35K ( accessories: 101N0400, 10-45Vdc) 1 Blow-up type, flow rate of capillary: 5L/min 1 +Φ1.5 electrophoresis and rust-resistance steel wire of Φ6 0.71 steel tube 4 0074180006 Dry filter 1 10g 5 0070301474 Refrigerant 45g R600a 6 7 8 9 HTCD-90: No. 1 2 3 4 5 0270700430 0270700431 0270700428A 0270700428 Material number Heat pipe Heat pipe Heat pipe Heat pipe 0274000118 Compressor 0270700427 Evaporator Ⅰ 0270700422 Evaporator Ⅱ 0270700425 0270700425A 1 R134a refrigerant 20g Left center 1 R134a refrigerant 20g Right center 2 R134a refrigerant 20g Lower layer 2 R134a refrigerant 20g Upper layer Description Quantity Main technical parameter Remark Wire and tube condenser Wire and tube condenser 2 BD-35K ( accessories: 101N0400, 10-45Vdc) 1 Blow-up type, flow rate of capillary: 5L/min 1 Φ6 0.75TP2M 10500mm, 5L/min 6 0074180006 Dry filter 2 10g 1 +Φ1.5 electrophoresis and rust-resistance steel wire of Φ6 0.71 steel tube 1 +Φ1.5 electrophoresis and rust-resistance steel wire of Φ6 0.71 steel tube 7 0070301474 Refrigerant 45g R600a Refrigerator Freezer 8 0270700429 Heat pipe 2 R134a refrigerant 18g Upper layer 9 0270700429A Heat pipe 2 R134a refrigerant 18g Lower layer 8

Refrigerating schematic diagram After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator Evaporator 蒸发器 Condenser 冷凝器 Dry 干燥过滤器 filter Capillary 毛细管 Muffler 回气管 Compre 压缩机 ssor Compre 压机油 ssor oil Exhaust pipe 排气管 VI. Parts layout 1. HTC-40 explosive view: 9

Refrigerator sensor Ice layer sensor Including the refrigerating control sensor and the display sensor Details of explosive view: 序号 专用号 名称 备注 No. Material number Description Remark 1 0274000357 太阳能显示屏 Solar screen 2 0070814623 把手总成 Handle assembly 3 0270102485B 冷藏内门 Inner door of refrigerator 4 0270700424 蒸发器 Evaporator 5 0070816334 铰链组装 - 组件 Hinge assembly-component 6 0270700425 后背冷凝器 Back condenser 7 0274000355 保险丝座 Fuse holder 8 0274000206C 太阳能输入线 Solar energy input wire 10

9 0274000354 电源开关 Power switch 10 11 12 13 0274000352 0274000356 0074180006 0274000118A 温控器 Temperature controller 电解电容 Electrolytic capacitor 干燥过滤器 Dry filter 压缩机 Compressor 14 0274000351 风机 Fan 15 0270200838 风机罩 Fan shield 16 0270102688D 筐 Basket 17 0270700429 上层热管 Upper heat pipe 18 0270700429A 下层热管 Lower heat pipe 19 0270200780 蓄热水盒 Hot water tank 0270400367 加热丝 Heater strip 20 0274000358 冷藏室传感器 Refrigerator sensor 21 0274000353 冰层传感器 Ice layer sensor 2 HTC-110 explosive view: 11

Refrigerator sensor Including the refrigerating control sensor and the display sensor Ice layer sensor Details of explosive view: 序号 专用号 名称 备注 No. Material number Description Remark 1 0274000357 太阳能显示屏 Solar screen 12

2 3 4 5 6 0070814623 0070816334 0270102485A 0270700424 0270700421 把手总成 Handle assembly 铰链组装 - 组件 Hinge assembly-component 冷藏区内门 Inner door of refrigerator 蒸发器 Evaporator 冷凝器 Condenser 7 0274000355 保险丝座 Fuse holder 8 9 10 11 0274000206C 0274000354 0274000352 0074180006 太阳能输入线 Solar energy input wire 电源开关 Power switch 温控器 Temperature controller 干燥过滤器 Dry filter 12 0274000356 电解电容 13 14 15 16 17 18 0274000118A 0274000351 0270200838 0270700430 0270700431 0270700428A 0270700428 压缩机 Compressor 风机 Fan 风机罩 Fan shield 热管 Heat pipe 热管 Heat pipe 热管 Heat pipe 热管 Heat pipe 左侧中间 Left center 右侧中间 Right center 下层 Lower layer 上层 Upper layer 19 0270200780 蓄热水盒 Hot water tank 20 0270400367 0270102688C 加热丝 Heater strip 大筐 Large basket 13

21 0274000358 冷藏室传感器 Refrigerator sensor 22 0274000353 冰层传感器 Ice layer sensor 3. HTCD-90 explosive view: Refrigerator sensor Freezing chamber sensor Ice layer sensor Including the refrigerating control sensor and the display sensor Including the freezing control sensor and the display sensor Details of explosive view: 序号 专用号 名称 备注 No. Material number Description Remark 14

1 0274000357 太阳能显示屏 Solar screen 2 0070814623 把手总成 Handle assembly 3 0270102484 冷冻内门组装 Inner door of freezer 4 0270102485 冷藏内门组装 Inner door of refrigerator 5 0070816334 铰链组装 - 组件 Hinge assembly-component 6 0270700425A 冷凝器 Condenser 7 0270700425 冷凝器 Condenser 远压机 Far-end compressor 近压机 Near-end compressor 8 0270700424 蒸发器 Evaporator 9 0274000206C 太阳能输入线 Solar energy input wire 10 0274000354 电源开关 Power switch 11 0274000352 温控器 Temperature controller 12 0274000355 保险丝座 Fuse holder 13 0074180006 干燥过滤器 Dry filter 14 0274000356 电解电容 Electrolytic capacitor 15 0274000118A 压缩机 Compressor 16 0274000351 风机 Fan 17 0270200838 风机罩 Fan shield 18 0270700429 热管 Heat pipe 19 0270700429A 热管 Heat pipe 上层 Upper layer 下层 Lower layer 20 0270102688C 筐 Basket 15

21 0270200780 蓄热水盒 Hot water tank 0270400367 加热丝 Heater strip 22 0274000358 冷藏室传感器 Refrigerator sensor 23 0274000357A 冷冻室传感器 Freezer sensor 24 0274000353 冰层传感器 Ice layer sensor VII. Operation guide Temperature controller (in the electric cabinet of the product) 1. Ice layer sensor: control the startup and shutdown of refrigerator compressor. The parameter setting is SP1, which can be automatically adjusted as per the environment and cannot be manually adjusted. 2. Refrigerator sensor: control the heating, startup and shutdown of the heat storage module. The parameter setting is SP2, which can be manually adjusted. 3. Freezing sensor: control the startup and shutdown of freezing compressor. The parameter setting is SP3, which can be manually adjusted. 4. Ambient temperature sensor: have no display or control function 5. Sensor of refrigerator temperature displayer: have the display function rather than the control function 6. Sensor of freezer temperature displayer: have the display function rather than the control function 参数 描述 最小值 最大值 单位 默认值 Parameter Description Minimum value Maximum value Unit Default SP1 控制温度 1 r1 r0 o C 0 Control temperature 1 SP2 控制温度 2 Control temperature 2 r1 r0 o C 4 SP3 控制温度 3 Control temperature 3 r3 r2 o C -12 r0 SP1/SP2 可设置温度最大值 r1 85.0 o C 8.0 16

r1 r2 r3 After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator SP1/SP2: able to set the maximum temperature SP1/SP2 可设置温度最小值 SP1/SP2: able to set the minimum temperature SP3 可设置温度最大值 SP3: able to set the maximum temperature SP3 可设置温度最小值 SP3: able to set the minimum temperature -45.0 r0 r3 85.0-45.0 r2 o C 2.0 o C 0.0 o C -20.0 The controller will be locked automatically and the buzzer will be run for about 0.5s when the temperature controller setting is made and no operation is made via any key within 3min. Please press the and the key for 5 seconds to unlock or lock the controller. At the same time, the buzzer will be run for about 0.5s. When the controller is locked, no operation is allowed. The operation can only initialize when unlocking the controller. Press and hold the key for 5s in the unlocking state. Then, the ice layer display window will flash and display SP1 and the freezer display window will flash and display the target value of ice layer (corresponding value +CA0 can be worked out according to the ambient temperature table). Such target value cannot be set, but can be modified via CA0. Press and hold the key for 5s in the unlocking state. Then, the ice layer display window will flash and display SP3 and the freezer display window will flash and display the freezer target value. The parameter value can be adjusted via the or the. Press and hold the for 5s to save the data once the parameter value is set. Press and hold the key for 3s in the unlocking state. Then, the ice layer display window will flash and display SP3 and the freezer display window will flash and display the refrigerator target value. The parameter value can be adjusted via the or the. Press and hold the for 5s to save the data once the parameter value is set. Note: the buzzer of this product model is turned off by default when being delivered and only the alarm code is displayed! II. Parameter setting of general menu 1. Press the key for more than 5S to display the parameter code PS (password) on the screen; 2. Roll the parameters (PS, AH1,AL1,AH2,AL2,AH3,AL3) with the and the key; 3. Press the key to confirm the parameter and display the parameter value; 4. Increase or decrease the parameter value with the or the key; 5. Press the key to store the modified parameter value temporarily and to return to displayed parameter; 6. Repeat the step 3 to 5 to modify other parameters; 7. Press the key for more than 5s to save the modified parameter and return to the normal condition. The controller parameters are covered in the general menu and the management menu. General menu 17

参数 Parameter PS AH1 AL1 AH2 AL2 AH3 AL3 描述 Description 访问管理菜单的密码 Access password of management menu 冰层高温报警温度 High temperature alarm of ice layer 冰层低温报警温度 Low temperature alarm of ice layer 冷藏室高温报警温度 High temperature alarm of refrigerator 冷藏室低温报警温度 Low temperature alarm of refrigerator -45.0 冷冻室高温报警温度 High temperature alarm of freezer 冷冻室低温报警温度 Low temperature alarm of freezer 最小值 Minimum value 最大值 Maximum value 单位 Unit 默认值 Default -50 100 -- -15 AL1+0.1 80.0 oc 80.0-45.0 AH1-0.1 oc -45.0 AL2+0.1 80.0 oc 8.0-45.0 AH2-0.1 oc 2.0 AL3+0.1 80.0 oc 80.0-45.0 AH3-0.1 oc -45.0 III. Alarm description 显示符号 Displayed symbol Er1 Er2 Er3 Er4 AH1 AL1 AH2 AL2 AH3 符号说明 Symbol description 蓄冰传感器故障 Ice storage sensor failure 冷藏传感器故障 Refrigerating sensor failure 冷冻传感器故障 Freezing sensor failure 环温传感器故障 Ambient temperature sensor failure 冰层高温报警 High temperature alarm of ice layer 冰层低温报警 Low temperature alarm of ice layer 冷藏高温报警 High temperature refrigerating alarm 冷藏低温报警 Low temperature refrigerating alarm 冷冻高温报警 18

AL3 IV. After-sales service manual of HTC-40/110 and HTCD-90 solar refrigerator High temperature freezing alarm 冷冻低温报警 Low temperature freezing alarm Schematic diagram for connection Ice layer Refrigeratin g Freezing Heater strip Power supply Ice layer Refrigera Freezing Ambient ting temperatur e 1. Please confirm if the voltage of the power supply can meet the power supply requirements for controller. Otherwise, the instrument may fail to be run normally or be burned. 2. Color of sensor terminal: Ice layer sensor: blue Refrigerating sensor: red Freezing sensor: yellow Ambient temperature sensor: white Introduction to temperature displayer (on the product door): 温度显示区 Temperature display area 太阳能接收区 solar energy receiving area 温度显示区 temperature display area 太阳能接收区 solar energy receiving area Note: one temperature displayer is shared by HTC-40 and HTC-110; Two temperature displayers are applicable to HTCD-90. REFRIGERATOR---display the temperature of the refrigerator. FREEZER---display the temperature of the freezer. This displayer has the solar energy power supply function that the additional circuit connection is not required. This displayer only indicates the internal temperature and is unable to control any refrigerating system and others of the product. In the operation process, do not shield the solar energy receiving area. Otherwise, the temperature display area may fail to run. 19

VIII. Indications and alarm functions Alarm function of temperature controller: The parameters have been set before the delivery, which cannot be changed by the user. Displayed symbol Symbol description Alarm mode Alarm reset mode Er1 续冰传感器故障 Ice storage sensor failure 代码闪烁 Blinking codes 检修蓄冰传感器 Maintenance of ice storage sensor Er2 冷藏传感器故障 Refrigerating sensor failure 代码闪烁 Blinking codes 检修冷藏传感器 Maintenance of refrigerating sensor Er3 冷冻传感器故障 Freezing failure sensor 代码闪烁 Blinking codes 检修冷冻传感器 Maintenance of freezing sensor Er4 环温传感器故障 Ambient temperature sensor failure 代码闪烁 Blinking codes 检修环温传感器 Maintenance of ambient temperature sensor AH1 冰层高温报警 High temperature alarm of ice layer 代码闪烁 Blinking codes 温高降温后自动解除或者检修传感器 Automatic recover when the high temperature is dropped or maintenance of sensor AL1 冰层低温报警 Low temperature alarm of ice layer 代码闪烁 Blinking codes 环温过低导致水箱过冷冻 Over-freezing of water tank due to excessively-low ambient temperature AH2 冷藏高温报警 High temperature refrigerating alarm 代码闪烁 Blinking codes 温高降温后自动解除或者检修传感器 Automatic recover when the high temperature is dropped or maintenance of sensor AL2 冷藏低温报警 Low temperature refrigerating alarm 代码闪烁 Blinking codes 检查加热功能, 检修传感器 Check of sensor heating function and maintenance of AH3 冷冻高温报警 High temperature freezing alarm 代码闪烁 Blinking codes 温高降温后自动解除或者检修传感器 Automatic recover when the high temperature is dropped or maintenance of sensor AL3 冷冻低温报警 Low temperature freezing alarm 代码闪烁 Blinking codes 检查环温是否过低, 导致箱内温度过低, 或检修传感器 Check if the low inner temperature is caused by the ambient temperature or maintain the sensor. 20

IX. Precautions for installation and commissioning Precautions for product installation: 1. The equipment shall be installed in a sunny day with sufficient daylight. Please carefully go through this instruction before the installation. 2. Before installing the solar panel, please carefully learn the accompanying installation video. 3. Confirm if the solar panel is installed on the solid ground. The open space which is not easily to be shielded and is easy to be scrubbed is recommended. 4. Select the installation angle matching with the local lighting conditions. 1) The solar panel shall face to the equator. Namely, it shall face toward the south direction in the Northern Hemisphere and toward the north in the Southern Hemisphere. 2) The dip angle of the solar panel is subject to the terrestrial latitude of the installation location. The general dip angle of the solar panel is as shown in the figure below. 3) For the user near the equator, the installation angle of the solar panel shall not be too small, to ensure that the rainwater can smoothly flow down. 5. The ground rod shall be inserted into the ground at the depth of 1.5m and be spaced to those of other products by 2m at least. The ground lead shall be firmly fixed. 6. The refrigerator shall be placed in the cool and well-ventilated location and be kept away from the direct solar radiation. The ground shall be flat. The refrigerator shall be installed in such a way that each side shall be distanced by 15cm from the wall at least, to guarantee the good radiation. The ground shall be kept clean, to avoid the blockage of the front and rear cabin. 7. Precautions for water feeding of water tank: 1) Please go through the stickers on the water tank before feeding water. 2) Pour the corrosion inhibitor into the water tank first and then add the purified water until reaching the water level. 3) Install the water injection plug in place again after feeding the water. 4) Please keep the corrosion inhibitor away from the children and appropriately dispose the empty bottle. 8. This product is supplied without the truckle. Please lift the box body via the lifting handle on both sides in the process of transferring. Do not drag the product by force. Introduce the usage to the user: when the solar panel and the refrigerator are installed in place, please correctly connect the connecting line of the solar panel system as per the requirements. Test the solar connecting line with a multimeter to confirm the anode and the cathode. 21

9. Connect the solar power supply line to the plug of the refrigerator. 10. Open the front shield of the refrigerator cabin, correctly connect the wire, power on the temperature controller and display the current temperature. If no display is given, please immediately cut off the power supply and check the power supply polarity. The water tank temperature is displayed on the upper display, while the freezer temperature is displayed on the lower display. The water tank temperature is displayed on the upper display, while the freezer temperature is displayed on the lower display. Note: for HTC-40 and HTC-110, only the upper screen is applicable. For HTCD-90, the two screens are applicable. X. Replacement guide for key components 10.1 Precautions for disassembly and installation Be sure to disconnect the power plug in the disassembly and installation process; Please install the product in reverse order. Any component must be assembled in its specified locations in the process of installation. 10.2 Disassembly and installation guide for key components Replacement of compressor E-box Fixing bolt x4 Muffler of compressor Exhaust pipe of compressor Process pipe 22

When the compressor fails and the replacement is required, please follow the steps below: 1. Disconnect the plug on the compressor accessories (E-box); 2. Discharge the refrigerant from the refrigerating system via the process pipe (be sure to stay away from the fire); 3. Burn off the exhaust pipe of return-gas box after emptying the refrigerant from the system (rinse the system with nitrogen and burn the pipeline with the welding gun, if possible); 4. Remove the compressor fixing screws (4) with a 10mm open spanner; 5. Replace the compressor with a new one, fix and connect the pipeline as per the original; 6. Replace the process pipe with a new one, pump off the system (until the pressure is below 3p) and re-fill 45g of 600a refrigerant (±1g). 7. Seal the process pipe. Precaution: 1. As the moisture requirement for the system is very strict, the machine pipeline shall be immediately sealed after being opened, to avoid the moisture invade from the air. It is required that each opened pipelined shall be welded within 10min. 2. Before welding the pipeline, be sure to empty the refrigerant in the system. Especially, when spraying the oil mist, the open air shall be avoided, to avoid the fire disaster and the fire blast. As the inflammable and explosive R600a refrigerant is used by the product, be sure to provide the good ventilation in the working environment. Replacement of 15A fuse (in the electric cabinet) The rated current of this fuse is 15A. The fuse is located in the electric cabinet of the refrigerator, which shall be replaced according to the steps below: Fuse size Appearance of fuse 1. Open the rear cover of electric control box; 2. Take out the protective shell of fuse holder; Replacement of fan: When the fan fails and the compressor fails and the replacement is required, please follow the steps below: 1. Disconnect the fan connecting plug on the compressor accessories (E-box); 2. Carefully spread the plastic claws (4 pcs) for clamping the fan and take out the fan. 3. Install a new fan and mind the wind direction of the fan (by blowing to the compressor). 4. Connect the fan connection terminal and mind the cathode and the anode (the red wire is the cathode). 23

Connect the fan terminal on the compressor accessory. The 3rd and 4th terminals are the fan connection terminals. Fig.1 Disassembly of rear cabin grilling 卡爪 Claws Fig.2 Carefully spread claws (4 PCS) Replacement of electric temperature controller: When the electric temperature controller fails and the compressor fails to be started normally, please replace the electric temperature controller according to the steps below: 1. Open the electric cabinet on the back; 2. Take out the connection wire of the temperature controller to be replaced; 3. Replace the failed temperature controller with a new one. 4. Connect to the power supply and select the temperature controller as per the equipment model. Fig.1 Removing electric cabinet cover Fig.2 Taking out and replacing temperature controller Note: please connect the temperature controller to the power supply after the replacement and 24

adjust the PCH value according to the aforesaid adjustment method. PCH product model options 1:HTCD-160 2:HTC-60H- 3:HTC-40 4:HTCD-90 5:HTC-110 6:HTD-60 7:HTC-200 XI. Transportation conditions, installation environment and package disassembly 1. Transportation and transferring conditions (1) The inclination angle of refrigerating shall not be greater than 45 in the process of transferring. (2) Please note that the refrigerator must be transferred with a dedicated dumper or a forklift. It is forbidden to slide or throw the refrigerator from the high place. (3) To avoid the personal injury or the refrigerator damage, mind you step when transferring the refrigerator. (4) Do not try to lift or transfer the equipment via the door handle, to avoid refrigerator damage or personal injury. 2. Installation environment (1) The ambient temperature: is 5 to 43 and the optimal temperature is18 to 32. Use the air conditioning system in the extreme weather. (2) Ambient humidity: less than 85%Rh (3) Do not install the refrigerator (freezer) in the dusty condition. (4) Take measures to avoid the rock or vibration. (5) Altitude of refrigerator: less than 2000m (6) Please locate the refrigerator in the bright location without direct solar radiation. 3. Package disassembly (1) Open the package by lifting the carton box with several hands. (2) Open the package by lifting the carton box with several hands. (3) Take down the cork base. Note: the inclination angle of the refrigeration shall not be greater than 45 in the above process. Please attach importance to the safety in this process, to avoid unnecessary personal injury. 25

XII. Test curve HTC-40 curves: Description 1. This test curve is made at the ambient temperature of 43 ; 2. When the product is normally connected to the power supply by the user, the inner temperature of the box can reach 2-8 for about 4 days when the light is sufficient. HTC-110 curves: Description 1. This test curve is made at the ambient temperature of 43 ; 2. When the product is normally connected to the power supply by the user, the inner temperature of the box can reach 2-8 for about 4 days when the light is sufficient. HTCD-90 curves: 26

Description: 1. This test curve is made at the ambient temperature of 43 ; 2. When the product is normally connected to the power supply by the user, the inner temperature of the box can reach 2-8 for about 4 days when the light is sufficient; 3. The freezer is applicable only when the inner temperature is below-5. 27

Inspired living Haier Medical & Laboratory Products Co., Ltd. Room 403D, Brand Building, Haier Industrial Park, No.1 Haier Road Qingdao China Website: www.haiermedical.com 28