CABINET RANGES FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

Similar documents
PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

A-MIP 100 Installation and Operating Manual

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

A-MIP 210 Installation and user guide

600 Range Dialer Installation Manual. Version 1.0

A-MIP 200 Installation and Operating Manual

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

IntesisBox BACnet/IP Server - Notifier ID3000 series

Cold chain monitoring technologies. Facility monitoring

The future of security, secured IP by security professionals, for the professional security industry

Smart Wireless Sensor

Smart Wireless Sensor

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Patriot Systems Limited

IP & SMS Alarm Communicator

PR / MP I Laboratory / Medicine

Danfoss gas detection units

Medical Refrigerators

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Patriot Systems Limited

idware Idware Remote Site Monitoring Solution

Multi-Gas-Controller MGC2

Monitoring solutions

YOUR SCHOOL STAFF NEEDS PROTECTION

English. Doro CareIP Mobile. User Guide

Сontrol panel Contact GSM-9N

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

2G & 3G GSM Wireless Beam Alarm

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1


Delivering reliable power for patient safety

Fire control panels FC360

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

THX-DL Data Logger USER & INSTALLATION MANUAL V

Table of Contents 1. INTRODUCTION 1 2. PANEL INFORMATION 2 3. GETTING STARTED 5 4. CONNECTION TO PANEL WEBPAGE 9 5. DEVICE MANAGEMENT 11

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

LR range (solid door) LR 750 G / GG

For Complete Fire and Gas Solutions

Call stations and extensions

University. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

Memcom Emergency Telephone

Remotely programmable and controllable alarm system

GLOBAL. InstallatIon & operation manual

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

IRIS Touch Firmware Enhancements and Additions from Version to Version

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

AUTOMATION. Presents. Smart Hotels Technical

CAN unit for Analog Sensors

2G & 3G GSM Door Contact Alarm

S3b Sim Secual / S3b Sim Vid Secual GSM Alarm System

Security Alarm Systems

Upgrade of PSTN network Alarm System

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

MONECA SMART Smart card hydrant

SMS GSM Alarm Messenger

Manual & Technical Documentation V1.1

ACTIVE INFRARED BARRIER

NC 100. Vertical Steam Sterilizer

2G & 3G GSM Portable PIR Alarm

Outdoor Temperature Sensor

Contents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

COMMUNICATOR ET08 / ET081

Elemec3. Networked Public Address and General Alarm System (PA/GA)

GasGard 100 Control System

Architectural and Engineering Specification for a Real-Time Locating System Flare

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

OPTIMUM APPLIED SYSTEMS,

Danfoss gas detection units

ProCom The App for Alarm Systems in the Protect Series Operating Manual

1. Functions of GPS locator ETLOC-30S 3

Combined CAN Sensor Unit Temperature, Humidity and Smoke

TELECOMMUNICATION. Telecommunication. Wireless Phone

HRX3000. Technical Manual

Panel Mounted Fault Annunciator Series

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

PERMACONN PM1030 Includes DI300. Installation Manual

HRX Technical Manual. Version 1.2

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

GSM RFID VOICE Alarm System

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

NC SERIES. Bench Top Steam Sterilizers

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Vehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns

Fratech Multipath-IP STU

Avigilon Control Center 5 System Integration Guide

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

DSE ELECTRONIC SIRENS Advantages & Functions

Transcription:

CABINET RANGES FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

AEDs are medical equipment that can be used by the general public Each one has an indicator light that shows the operational status. They must be installed under conditions that are in conformance with the recommendations. AIVIA solutions complete AEDs, make them available, and ensure their operability. CRA (Cardio respiratory Arrest), more commonly known as "sudden death", is the primary cause of mortality in developed countries. Making AEDs available for public access is a solution encouraged by medical authorities to increase survival rates. AIVIA is a solution designed and created by PYRESCOM SAS SAS (a French company, ISO 9001 and 14001 certified), which meets all the EC requirements and standards. AIVIA cabinets adapt to the various installation environments and combine advanced functions related to the defibrillator so that it is available under optimum conditions of use. 388mm 201mm 423mm AED acces programme survival curve (%) To be suitable for all situations in the PAD (public access defibrillator) programme, a complete range of 10 cabinet models for the protection and monitoring of AEDs provides many options and possible configurations according to the needs: Open or secured AED access Built-in hands-free telephony with automatic door release to communicate with a configured emergency number (PSTN, GSM) Heating, ventilation and external temperature control Automated remote control of installations via the Internet Camera monitoring of openings and AED entries, etc. Setting up DAE in Public Access... Operative thanks to AIVIA Survival rate in function of elapsed time 12 time elapsed (Min)

AIVIA This complete range ensures the protection of AED contents. S AED wall cabinet. Protective indoor cabinet with alarm. AIVIA monitoring protects the AED it contains in the same way as protective models, except that this feature includes an optical sensor that automatically handles visual monitoring of the AED standby light. EN 301 489-3 V1.4.1: 2002 EN 302 291-2 V1.1.1: 2005 EN 50364: 2001 EN 60950-1: 2006 +A11 : 2009 Power consumption Minimun: 200 ma. Maximum: 2 500 ma (With active heating) Ingress protection code: IP44 Humidity index: 95% % without condensation Protective outdoor cabinet. Protective cabinet with secured opening. Monitoring cabinet. Monitoring cabinet with secured opening. Protective cabinet with built-in telephony. Protective cabinet with built-in telephony and secured opening. Monitoring cabinet with built-in telephony. Monitoring cabinet with secured opening and built-in telephony. EN 55022: 2006 EN 55024: 1998/ A1: 2001/ A2 : 2003 EN 60950-1: 2006 Electromagnetic compatibility 2004/108/CE Low voltage directive 2006/95/CE Power consumption Minimum: 55 ma. Maximum: 2 400 ma (With active heating) Ingress protection code: IP44 Humidity index: 95% without condensation

IVIA OT AIVIA IOT uses LRWA (Long Range Wild Area) technology to transmit monitoring data. This innovative technology guarantees long-distance communications at a very low level of energy consumption. AIVIA M enables functional monitoring (statuses and conditions) of the AED with which it is associated. It can be placed either in the AED carry bag or in a wall cabinet. The AIVIA W models protect and monitor the AED they contain and give an alert for all events (opening of the AIVIA system, removal of the AED, condition of the AED, etc.). 9,7 cm 42,3 cm AIVIA NET The AIVIAnet server is an application that enables remote monitoring of cabinet/ AED sets. It makes it possible to provide users with information on the condition of the AED, its environment and associated incidents. Accessible from any terminal connected to the Internet User and password-protected access Multilingual Client terminal population control panel Colour code alert display AIVIA geolocalisation Individualised signals for actions to prepare Events record (traceability) Associated alert function configuration (e-mail, text message) Configuration of users, groups of users (badge no.) Display of pictures obtained when the AED is opened or removed Statistical data recovery (extraction in Excel) EN 60950-1: 2006 + A11 + A1 + A12 + A2 EN 301 489-3: 2013 V1.6.1 EN 300 220-2 V2.4.1 Autonomy: More than 3 years (AIVIA M and 100W). Humidity index: 95% without condensation.

AIVIA Configuration software with an online diagnostics capacity for AIVIA Protection Range (2XX) and Supervision Range (3XX): Digicodes for restricted access for both remote and manual opening. Three possible telephone settings (pressing a call button, upon opening, upon removal of AED unit). The possibility of programming telephone numbers into the unit. Configured thresholds for activating the heating and fanning systems and alert functions. Volume and duration settings for the alarm. Record keeping of past events. Specific configuration for the AIVIA supervision and monitoring range is available : The type of network (LAN, 3G). LAN configuration : IP or DHCP addressing, if necessary proxy parameters. 3G configuration : APN code, PIN number. AED, serial numbers, pads, battery, batch numbers, expiry dates. Location and geolocation data. Calibration of the optical sensor used for monitoring units. Designed for indoor or outdoor placement of AIVIAs, BORNAVIE and COLAVIE stands comply with current regulations applicable to street furniture. BORNAVIE and COLAVIE stands are delivered painted in green epoxy paint, RAL 6024 (established colour for Standard ISO 3864 safety signs). A choice of other colours is available. Basic stands have a surface finishing with the ERC and ILCOR standard heart as well as the mentions AED and DAE. Any other surface finishing is optional. COLAVIE 20/10th round and square section AG3 5754H111 aluminium tube frame with an 80/10th base and 50 and 30/10th reinforcements H: 2,425 cm - L: 820 cm - D: 260 cm Weight: 46 kg BORNAVIE 20/10th AG3 5754H111 aluminium with an 80/10th base H: 1,639 cm - L: 395 cm - D: 218cm Weight: 13kg

Lighting and alarm Sensor lighting. Local visual alarms that report anomalies. Automatic telephone door Analog handsfree telephony. Aivia 100 battery Power supplied by 4 LR20 batteries provided for lighting and alarm functions. Audible alarm Triggered on opening (from 70 to 50 db at 1m according to the model). Mains power 24V DC SELV (Safety Extra-Low Voltage). Secured opening The lid is opened by digicode or by swiping the RFID badge. Regulated heating and Ventilation Maintenance of a positive temperature of the AED efficient up to -20 C. Emergency battery Rechargeable to ensure vital functions (opening, telephony). GSM telephony The SIM card and a subscription with an operator are required at the client's expense. RFID badge reader Traceability of maintenance operations. Control picture Infra-red objective, picture taken when the AED is opened and removed, pictures transmitted and stored on AIVIAnet. In addition to the options available for each AIVIA model, customisation is also possible to suit the client's needs. The sticker on the front has the chain of survival and the symbols related to the use of the AIVIA. It enables the inclusion of logos and texts directly related to the desired visual message. your text and logo here Operation Continuous monitoring of the AED standby light. Transmission of AIVIA alerts and alarms. 3G Enables the AIVIA to communicate with the AIVIAnet server instead of an Ethernet connection. Internet of Things RLRWA (Long Range Wild Area) network. Tempered glass Polycarbonate door with surface treatment that provides the greenhouse effect. Lifespan 36 months of autonomy. Aivia net Enables remote monitoring of the cabinet and the AED in real time. Aivia M 3.6V battery

Distributed by: PYRESCOM Mas des Tilleuls 66680 Canohès. France aivia@pyres.com www.aivia.eu www.pyres.com Do not throw on public roads subject to typographical error A-WEB-DCAVD-EN20171102 Tel : +33 (0)4 68 68 39 68 Fax : +33 (0)4 68 68 39 69